Abstract:
:The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) technique, in which a single element in turn transmits and all the array elements receive the ultrasound wave, with the Filtered-Delay Multiply and Sum (F-DMAS) non-linear beamforming algorithm that we presented in a previous paper. We show that using F-DMAS, which is based on a measure of backscattered signal spatial correlation, B-mode images have a higher contrast resolution but suffer from a loss of brightness away from the transmit focus, when a classical scan with receive-only dynamic focusing is performed. On the other hand, when synthetic transmit focusing is achieved by implementing STA, such a loss is compensated for and a higher depth of field is obtained, as signal coherence improves. A drawback of SAF/STA however is the reduced signal-to-noise ratio, due to single-element transmission; in the paper we also analyze how this influences F-DMAS images. Finally, a preliminary investigation on the use of the classical monostatic SAF technique with F-DMAS beamforming is also carried out to evaluate its potential performances.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Matrone G,Savoia AS,Caliano G,Magenes Gdoi
10.1016/j.ultras.2016.11.022subject
Has Abstractpub_date
2017-03-01 00:00:00pages
216-225eissn
0041-624Xissn
1874-9968pii
S0041-624X(16)30335-3journal_volume
75pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on th...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2003.12.035
更新日期:2004-04-01 00:00:00
abstract::Nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease. Quantitative ultrasound facilitates clinical grading of hepatic steatosis (the early stage of NAFLD). However, the utility of quantitative ultrasound as a first-line method for community screening of hepatic steatosis remains unclear. T...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106329
更新日期:2021-03-01 00:00:00
abstract::This article proposes to estimate slow blood flow with high frequency ultrasound imaging. The proposed technique combines 2 methods. First, a statistical method, called Speckle Flow Imaging (SFI) based on the analysis of changes in the speckle pattern along time, gives an index directly related to the total velocity v...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.06.025
更新日期:2006-12-22 00:00:00
abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(00)00054-8
更新日期:2001-03-01 00:00:00
abstract::In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according t...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.09.007
更新日期:2016-02-01 00:00:00
abstract::This paper provides a derivation of the Christoffel eigenvalue equation for acoustic wave propagation in an acoustically damped piezoelectric medium. The damping tensor is shown to couple into both the stress and displacement constitutive equations. Application of the quasi-static approximation leads to an additional ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.09.005
更新日期:2006-12-01 00:00:00
abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2008.10.007
更新日期:2009-05-01 00:00:00
abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(94)90111-2
更新日期:1994-09-01 00:00:00
abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(03)00096-9
更新日期:2003-05-01 00:00:00
abstract::In this paper, the development of modified beamforming methods, Filtered Delay Weight Multiply and Sum (F-DwMAS) and Filtered Delay Euclidian-Weighted Multiply and Sum (F-DewMAS), are reported. These methods were investigated on a minimum-redundancy synthetic aperture technique, called as 2 element Receive Synthetic A...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106293
更新日期:2021-02-01 00:00:00
abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.10.018
更新日期:2013-03-01 00:00:00
abstract::It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimenta...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(88)90046-7
更新日期:1988-01-01 00:00:00
abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.06.007
更新日期:2006-12-22 00:00:00
abstract::Ultrasound evaluation permits the state of rocks to be determined quickly and cheaply, satisfying the demands faced by today's producers of ornamental stone, such as environmental sustainability, durability and safety of use. The basic objective of the present work is to analyse and develop the usefulness of ultrasoun...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.06.006
更新日期:2014-01-01 00:00:00
abstract::In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.008
更新日期:2017-03-01 00:00:00
abstract::Ultrasonic techniques have been used to measure the elastic properties of bone. Eight human tibiae were used to determine and map the elastic properties of cortical and cancellous bone. The present study shows cortical bone to be at least orthotropic in its material symmetry. The mechanical properties of cortical bone...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(96)00078-9
更新日期:1996-12-01 00:00:00
abstract::The main component of every device used for investigating internal object structure by Ultrasound Transmission Tomography (UTT) is a special ultrasonic probe. This paper presents the structure of model multielement ring probe for examining objects using this method in divergent ray projection geometry. The probe is ma...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.126
更新日期:2006-12-22 00:00:00
abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.07.018
更新日期:2006-12-01 00:00:00
abstract::This investigation deals with various new aspects of the sensitivity improvement of a pump-probe laser based acoustic method. A short laser pulse is used to excite a mechanical pulse thermo-elastically. Echoes of these mechanical pulses reaching the surface are causing a slight change of the optical reflectivity. The ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00207-x
更新日期:2002-05-01 00:00:00
abstract::As known, anomalous resisto-acoustic effect is a fundamental property for weakly inhomogeneous piezoactive waves (Bleustein-Gulyaev, Love, and some leaky waves). It consists in that the velocity of aforementioned waves first increases, achieves its maximum, and only then decreases with increasing conductance of a laye...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.01.007
更新日期:2015-05-01 00:00:00
abstract::We present a method to generate sub-microsecond quasi-unipolar pressure pulses. Our approach is based on the laser irradiation of a thin copper wire submerged in water. The acoustic waveforms were recorded using two different, well characterized, wideband detection techniques: piezoelectric and optical interferometry....
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.05.002
更新日期:2019-09-01 00:00:00
abstract::Transducer is the necessary and most important part in the maxonics. New applications demand for new transducer, and the renovation of the transducer will open a new field for the application of the maxonics. The important method to develop new transducer is to find and develop new material. The rare earth giant magne...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.128
更新日期:2006-12-22 00:00:00
abstract::The paper presents the characteristics of vertically polarized surface waves generated in silicon substrate by acoustic coupling of bulk waves excited in a periodically patterned ZnO film on silicon. The finite element simulations are performed on the proposed patterned-ZnO/Si structure and vertically polarized modes ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.01.008
更新日期:2015-05-01 00:00:00
abstract::The dispersion and attenuation features of the multi-physical fields coupled waves propagating in an infinite piezoelectric semiconductor and the reflection problem at a boundary which is mechanically free, electrically insulation and the dielectrically open circuit are studied in this paper. Different from the classi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2018.09.009
更新日期:2019-02-01 00:00:00
abstract::Lithium niobate, LiNbO(3), is a piezoelectric material well known for its high Curie temperature. However, it has often been neglected for use in ultrasonic transducers because of its low electro-mechanical coupling coefficients. Recent advances in signal processing have made this disadvantage less significant and we ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2007.06.001
更新日期:2007-12-01 00:00:00
abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.11.010
更新日期:2012-04-01 00:00:00
abstract::The importance of the analysis of the radiofrequency signal is by now recognized in the field of tissue characterization via ultrasound. The RF signal contains a wealth of information and structural details that are usually lost in the B-Mode representation. The HyperSPACE (Hyper SPectral Analysis for Characterization...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.02.010
更新日期:2016-05-01 00:00:00
abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.02.018
更新日期:2015-07-01 00:00:00
abstract::Targeted mechanical cell stimulation has been extensively studied for a better understanding of its effect on cellular mechanotransduction signaling pathways and structures by utilizing a variety of mechanical sources. In this work, an ultrasound-driven single cell stimulation method is thus proposed, and a preliminar...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.03.002
更新日期:2012-09-01 00:00:00
abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.05.003
更新日期:2005-01-01 00:00:00