Depth-of-field enhancement in Filtered-Delay Multiply and Sum beamformed images using Synthetic Aperture Focusing.

Abstract:

:The Synthetic Aperture Focusing (SAF) technique makes it possible to achieve a higher and more uniform quality of ultrasound images throughout depth, as if both transmit and receive dynamic focusing were applied. In this work we combine a particular implementation of SAF, called Synthetic Transmit Aperture (STA) technique, in which a single element in turn transmits and all the array elements receive the ultrasound wave, with the Filtered-Delay Multiply and Sum (F-DMAS) non-linear beamforming algorithm that we presented in a previous paper. We show that using F-DMAS, which is based on a measure of backscattered signal spatial correlation, B-mode images have a higher contrast resolution but suffer from a loss of brightness away from the transmit focus, when a classical scan with receive-only dynamic focusing is performed. On the other hand, when synthetic transmit focusing is achieved by implementing STA, such a loss is compensated for and a higher depth of field is obtained, as signal coherence improves. A drawback of SAF/STA however is the reduced signal-to-noise ratio, due to single-element transmission; in the paper we also analyze how this influences F-DMAS images. Finally, a preliminary investigation on the use of the classical monostatic SAF technique with F-DMAS beamforming is also carried out to evaluate its potential performances.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Matrone G,Savoia AS,Caliano G,Magenes G

doi

10.1016/j.ultras.2016.11.022

subject

Has Abstract

pub_date

2017-03-01 00:00:00

pages

216-225

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(16)30335-3

journal_volume

75

pub_type

杂志文章
  • Influence of acousto-optic interactions on the determination of the diffracted field by an array obtained from displacement measurements.

    abstract::This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.035

    authors: Certon D,Ferin G,Bou Matar O,Guyonvarch J,Remenieras JP,Patat F

    更新日期:2004-04-01 00:00:00

  • Utility of quantitative ultrasound in community screening for hepatic steatosis.

    abstract::Nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease. Quantitative ultrasound facilitates clinical grading of hepatic steatosis (the early stage of NAFLD). However, the utility of quantitative ultrasound as a first-line method for community screening of hepatic steatosis remains unclear. T...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106329

    authors: Chang TY,Chang SH,Lin YH,Ho WC,Wang CY,Jeng WJ,Wan YL,Tsui PH

    更新日期:2021-03-01 00:00:00

  • Estimation methods for flow imaging with high frequency ultrasound.

    abstract::This article proposes to estimate slow blood flow with high frequency ultrasound imaging. The proposed technique combines 2 methods. First, a statistical method, called Speckle Flow Imaging (SFI) based on the analysis of changes in the speckle pattern along time, gives an index directly related to the total velocity v...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.025

    authors: Aoudi W,Liebgott H,Needles A,Yang V,Foster FS,Vray D

    更新日期:2006-12-22 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • Optimized ultrasonic attenuation measures for non-homogeneous materials.

    abstract::In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.09.007

    authors: Genovés V,Gosálbez J,Carrión A,Miralles R,Payá J

    更新日期:2016-02-01 00:00:00

  • A derivation of the Christoffel equation with damping.

    abstract::This paper provides a derivation of the Christoffel eigenvalue equation for acoustic wave propagation in an acoustically damped piezoelectric medium. The damping tensor is shown to couple into both the stress and displacement constitutive equations. Application of the quasi-static approximation leads to an additional ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.005

    authors: Shane Fazzio R

    更新日期:2006-12-01 00:00:00

  • An adaptive threshold filter for ultrasound signal rejection.

    abstract::The threshold filter is a frequently used technique in ultrasound B-scan to reject the small echoes contributed from backscattering that blur the tissue interface and reduce the image contrast. Note that using the threshold based on one value would simultaneously destroy local waveform features of the reflection echoe...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.007

    authors: Tsui PH,Chang CC,Chang CC,Huang NE,Ho MC

    更新日期:2009-05-01 00:00:00

  • Induction of stress fibres and intercellular gaps in human vascular endothelium by shock-waves.

    abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(94)90111-2

    authors: Seidl M,Steinbach P,Wörle K,Hofstädter F

    更新日期:1994-09-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system.

    abstract::In this paper, the development of modified beamforming methods, Filtered Delay Weight Multiply and Sum (F-DwMAS) and Filtered Delay Euclidian-Weighted Multiply and Sum (F-DewMAS), are reported. These methods were investigated on a minimum-redundancy synthetic aperture technique, called as 2 element Receive Synthetic A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106293

    authors: Vayyeti A,Thittai AK

    更新日期:2021-02-01 00:00:00

  • Optimization of electrode size for aluminum-nitride matrix ultrasonic transducers in the frequency range above 200 MHz.

    abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.10.018

    authors: Wei Y,Herzog T,Heuer H

    更新日期:2013-03-01 00:00:00

  • Experimental estimation of the viscous component of ultrasound attenuation in suspensions of bovine skeletal muscle myofibrils.

    abstract::It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimenta...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(88)90046-7

    authors: Shore D,Miles CA

    更新日期:1988-01-01 00:00:00

  • Ultrasonic strain imaging and reconstructive elastography for biological tissue.

    abstract::Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.007

    authors: Khaled W,Reichling S,Bruhns OT,Ermert H

    更新日期:2006-12-22 00:00:00

  • New contributions to granite characterization by ultrasonic testing.

    abstract::Ultrasound evaluation permits the state of rocks to be determined quickly and cheaply, satisfying the demands faced by today's producers of ornamental stone, such as environmental sustainability, durability and safety of use. The basic objective of the present work is to analyse and develop the usefulness of ultrasoun...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.06.006

    authors: Cerrillo C,Jiménez A,Rufo M,Paniagua J,Pachón FT

    更新日期:2014-01-01 00:00:00

  • A new topological structure for the Langevin-type ultrasonic transducer.

    abstract::In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.008

    authors: Lu X,Hu J,Peng H,Wang Y

    更新日期:2017-03-01 00:00:00

  • An ultrasonic method for measuring the elastic properties of human tibial cortical and cancellous bone.

    abstract::Ultrasonic techniques have been used to measure the elastic properties of bone. Eight human tibiae were used to determine and map the elastic properties of cortical and cancellous bone. The present study shows cortical bone to be at least orthotropic in its material symmetry. The mechanical properties of cortical bone...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(96)00078-9

    authors: Rho JY

    更新日期:1996-12-01 00:00:00

  • The ultrasonic probe for the investigating of internal object structure by ultrasound transmission tomography.

    abstract::The main component of every device used for investigating internal object structure by Ultrasound Transmission Tomography (UTT) is a special ultrasonic probe. This paper presents the structure of model multielement ring probe for examining objects using this method in divergent ray projection geometry. The probe is ma...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.126

    authors: Gudra T,Opielinski KJ

    更新日期:2006-12-22 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Sensitivity improvement of a pump-probe set-up for thin film and microstructure metrology.

    abstract::This investigation deals with various new aspects of the sensitivity improvement of a pump-probe laser based acoustic method. A short laser pulse is used to excite a mechanical pulse thermo-elastically. Echoes of these mechanical pulses reaching the surface are causing a slight change of the optical reflectivity. The ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00207-x

    authors: Vollmann J,Profunser DM,Dual J

    更新日期:2002-05-01 00:00:00

  • The peculiarities of the Bleustein-Gulyaev wave propagation in structures containing conductive layer.

    abstract::As known, anomalous resisto-acoustic effect is a fundamental property for weakly inhomogeneous piezoactive waves (Bleustein-Gulyaev, Love, and some leaky waves). It consists in that the velocity of aforementioned waves first increases, achieves its maximum, and only then decreases with increasing conductance of a laye...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.007

    authors: Kuznetsova IЕ,Zaitsev BD

    更新日期:2015-05-01 00:00:00

  • Generation of sub-microsecond quasi-unipolar pressure pulses.

    abstract::We present a method to generate sub-microsecond quasi-unipolar pressure pulses. Our approach is based on the laser irradiation of a thin copper wire submerged in water. The acoustic waveforms were recorded using two different, well characterized, wideband detection techniques: piezoelectric and optical interferometry....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.05.002

    authors: González MG,Riobó LM,Ciocci Brazzano L,Veiras FE,Sorichetti PA,Santiago GD

    更新日期:2019-09-01 00:00:00

  • Rare earth ultrasonic transducer technique research.

    abstract::Transducer is the necessary and most important part in the maxonics. New applications demand for new transducer, and the renovation of the transducer will open a new field for the application of the maxonics. The important method to develop new transducer is to find and develop new material. The rare earth giant magne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.128

    authors: Liu W,Zhou L,Xia T,Yu H

    更新日期:2006-12-22 00:00:00

  • Investigation of properties of surface acoustic waves generated by periodically patterned ZnO on silicon substrate.

    abstract::The paper presents the characteristics of vertically polarized surface waves generated in silicon substrate by acoustic coupling of bulk waves excited in a periodically patterned ZnO film on silicon. The finite element simulations are performed on the proposed patterned-ZnO/Si structure and vertically polarized modes ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.008

    authors: Santosh GS,Nemade HB

    更新日期:2015-05-01 00:00:00

  • The dispersion and attenuation of the multi-physical fields coupled waves in a piezoelectric semiconductor.

    abstract::The dispersion and attenuation features of the multi-physical fields coupled waves propagating in an infinite piezoelectric semiconductor and the reflection problem at a boundary which is mechanically free, electrically insulation and the dielectrically open circuit are studied in this paper. Different from the classi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.09.009

    authors: Jiao F,Wei P,Zhou X,Zhou Y

    更新日期:2019-02-01 00:00:00

  • 1-3 connectivity lithium niobate composites for high temperature operation.

    abstract::Lithium niobate, LiNbO(3), is a piezoelectric material well known for its high Curie temperature. However, it has often been neglected for use in ultrasonic transducers because of its low electro-mechanical coupling coefficients. Recent advances in signal processing have made this disadvantage less significant and we ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.001

    authors: Schmarje N,Kirk KJ,Cochran S

    更新日期:2007-12-01 00:00:00

  • Bonding and impedance matching of acoustic transducers using silver epoxy.

    abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.11.010

    authors: Son KT,Lee CC

    更新日期:2012-04-01 00:00:00

  • Multidimensional spectral analysis of the ultrasonic radiofrequency signal for characterization of media.

    abstract::The importance of the analysis of the radiofrequency signal is by now recognized in the field of tissue characterization via ultrasound. The RF signal contains a wealth of information and structural details that are usually lost in the B-Mode representation. The HyperSPACE (Hyper SPectral Analysis for Characterization...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.02.010

    authors: Granchi S,Vannacci E,Biagi E,Masotti L

    更新日期:2016-05-01 00:00:00

  • Dynamic interrogator for elastic wave sensing using Fabry Perot filters based on fiber Bragg gratings.

    abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.02.018

    authors: Harish AV,Varghese B,Rao B,Balasubramaniam K,Srinivasan B

    更新日期:2015-07-01 00:00:00

  • Fluorescence response of human HER2+ cancer- and MCF-12F normal cells to 200MHz ultrasound microbeam stimulation: a preliminary study of membrane permeability variation.

    abstract::Targeted mechanical cell stimulation has been extensively studied for a better understanding of its effect on cellular mechanotransduction signaling pathways and structures by utilizing a variety of mechanical sources. In this work, an ultrasound-driven single cell stimulation method is thus proposed, and a preliminar...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.03.002

    authors: Hwang JY,Lee J,Lee C,Jakob A,Lemor R,Medina-Kauwe LK,Shung KK

    更新日期:2012-09-01 00:00:00

  • Development of a portable 3D ultrasound imaging system for musculoskeletal tissues.

    abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.05.003

    authors: Huang QH,Zheng YP,Lu MH,Chi ZR

    更新日期:2005-01-01 00:00:00