Utility of quantitative ultrasound in community screening for hepatic steatosis.

Abstract:

:Nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease. Quantitative ultrasound facilitates clinical grading of hepatic steatosis (the early stage of NAFLD). However, the utility of quantitative ultrasound as a first-line method for community screening of hepatic steatosis remains unclear. Therefore, this study aimed to investigate the utility of quantitative ultrasound to screen for hepatic steatosis and for metabolic evaluation at the community level. In total, 278 participants enrolled from a community satisfied the study criteria. Each subject underwent anthropometric and biochemical examinations, and abdominal ultrasound imaging was performed to measure the controlled attenuation (CAP), integrated backscatter (IB), and information Shannon entropy (ISE). The assessment outcomes were compared with the fatty liver index (FLI), hepatic steatosis index (HSI), metabolic syndrome (MetS), and insulin resistance to evaluate the screening performance through the area under the receiver operating characteristic curve (AUROC) and Delong's test. Ultrasound ISE, CAP, and IB were effective in screening hepatic steatosis, MetS, and insulin resistance. In screening for hepatic steatosis, the AUROCs of ISE, CAP, and IB were 0.85, 0.83, and 0.80 (the cutoff FLI = 60), respectively, and 0.84, 0.75, 0.77 (the cutoff HSI = 36), respectively, and those for the evaluation of MetS and insulin resistance were 0.79, 0.75, 0.79, respectively, and 0.83, 0.76, 0.78, respectively. Delong's test revealed that ISE outperformed CAP and IB for the detection of hepatic steatosis and insulin resistance (P < .05). Based on the present results, ultrasound ISE is a potential imaging biomarker during first-line community screening of hepatic steatosis and insulin resistance.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Chang TY,Chang SH,Lin YH,Ho WC,Wang CY,Jeng WJ,Wan YL,Tsui PH

doi

10.1016/j.ultras.2020.106329

subject

Has Abstract

pub_date

2021-03-01 00:00:00

pages

106329

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(20)30261-4

journal_volume

111

pub_type

杂志文章
  • Solder joint failure localization of welded joint based on acoustic emission beamforming.

    abstract::A localization approach of welded joint damage is proposed based on acoustic emission (AE) beamforming. In this method, a uniform line array is introduced to detect the AE signal of welded joints in specified area. In order to investigate the influence of fillet and crimping commonly existing in a welded plate structu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.002

    authors: Liu X,Xiao D,Shan Y,Pan Q,He T,Gao Y

    更新日期:2017-02-01 00:00:00

  • Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system.

    abstract::In this paper, the development of modified beamforming methods, Filtered Delay Weight Multiply and Sum (F-DwMAS) and Filtered Delay Euclidian-Weighted Multiply and Sum (F-DewMAS), are reported. These methods were investigated on a minimum-redundancy synthetic aperture technique, called as 2 element Receive Synthetic A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106293

    authors: Vayyeti A,Thittai AK

    更新日期:2021-02-01 00:00:00

  • Experiment and numerical simulation for laser ultrasonic measurement of residual stress.

    abstract::Laser ultrasonic is a most promising method for non-destructive evaluation of residual stress. The residual stress of thin steel plate is measured by laser ultrasonic technique. The pre-stress loading device is designed which can easily realize the condition of the specimen being laser ultrasonic tested at the same ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.013

    authors: Zhan Y,Liu C,Kong X,Lin Z

    更新日期:2017-01-01 00:00:00

  • Quantification of elasticity changes in the myometrium during labor using Supersonic Shear Imaging: a feasibility study.

    abstract::Very little is known about the myometrium's physiology in terms of its elasticity but shear wave elastography could be an efficient tool to better understand it. This could considerably help the prevention of difficult births, the consequences of which are tremendous for neonate morbidity and pathologies. The purpose ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.07.013

    authors: Gennisson JL,Muller M,Gabor P,Frydman R,Musset D,Tanter M,Ami O

    更新日期:2015-02-01 00:00:00

  • Influence of bubble clustering on multibubble sonoluminescence.

    abstract::Influence of clustering of cavitation bubbles on multibubble sonoluminescence (MBSL) in standing wave fields is studied through measurement of MBSL intensity with a photomultiplier tube and observation of corresponding bubble behavior with a high-speed video camera and an intensified charge-coupled device one. It is c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00193-2

    authors: Hatanaka S,Yasui K,Kozuka T,Tuziuti T,Mitome H

    更新日期:2002-05-01 00:00:00

  • Ultrasonic digital interferometer for investigation of blood clotting.

    abstract::The digital ultrasonic fixed path interferometer designed for testing small amounts of sample was used for the investigation of whole blood coagulation, retraction and clot melting processes. The ultrasound velocity and absorption are determined from the characteristics of an acoustic resonator consisting of an emitte...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(78)90007-0

    authors: Grybauskas P,Kundrotas K,Sukackas V,Yaronis E

    更新日期:1978-01-01 00:00:00

  • The sensitivity of surface guided modes to the bond quality between a concrete block and a composite plate.

    abstract::Ultrasonic modes guided along the surface of a concrete block covered by a composite plate are investigated. First of all, the propagation phenomenon is studied by predicting the dispersion curves for various modes supposed to exist in this structure. Then, focus is made on a specific mode expected to be sensitive to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.074

    authors: Castaings M,Hosten B,François D

    更新日期:2004-04-01 00:00:00

  • Guided wave propagation in a honeycomb composite sandwich structure in presence of a high density core.

    abstract::A coordinated theoretical, numerical and experimental study is carried out in an effort to interpret the characteristics of propagating guided Lamb wave modes in presence of a high-density (HD) core region in a honeycomb composite sandwich structure (HCSS). Initially, a two-dimensional (2D) semi-analytical model based...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.05.025

    authors: Sikdar S,Banerjee S

    更新日期:2016-09-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • Development of an optical fiber hydrophone with fiber Bragg grating

    abstract::A new type of optical fiber hydrophone is constructed with a fiber Bragg grating (FBG) based on the intensity modulation of laser light in an FBG under the influence of sound pressure. The FBG hydrophone shows linearity, with dynamic range about 70 dB. It can measure amplitude and phase of an acoustic field in real ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00105-5

    authors: Takahashi N,Yoshimura K,Takahashi S,Imamura K

    更新日期:2000-03-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • The applicability of a material-treatment laser pulse in non-destructive evaluations.

    abstract::A practical optodynamic study was performed to determine the usability of different lengths of laser pulses for the generation of ultrasonic transients in a solid material. The aim of the study was to evaluate the possibility of a dual use for a laser pulse-for laser material processing, on the one hand, and for the u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.071

    authors: Hrovatin R,Petkovsek R,Diaci J,Mozina J

    更新日期:2006-12-22 00:00:00

  • In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach.

    abstract::Although, high resolution, real-time ultrasonic (US) imaging is routinely available, image interpretation is based on grey-level and texture and quantitative evaluation is limited. Other potentially useful diagnostic information from US echoes may include modifications in tissue acoustic parameters (speed, attenuation...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.002

    authors: Meziri M,Pereira WC,Abdelwahab A,Degott C,Laugier P

    更新日期:2005-03-01 00:00:00

  • Theoretical and experimental investigation of fluid rheology effects on modulated ultrasound propagation.

    abstract::A mathematical model is developed and presented to capture the effect of viscoelastic nature of a material on modulated ultrasound (US) pulses. The model is established by considering perturbation of material elements subject to modulated US pulses and by introducing the exponential relaxation of the perturbed fluid e...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.05.014

    authors: Özkök O,Uludag Y

    更新日期:2014-09-01 00:00:00

  • Ultrasonic geometrical characterization of periodically corrugated surfaces.

    abstract::Accurate characterization of the characteristic dimensions of a periodically corrugated surface using ultrasonic imaging technique is investigated both theoretically and experimentally. The possibility of accurately characterizing the characteristic dimensions is discussed. The condition for accurate characterization ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.006

    authors: Liu J,Declercq NF

    更新日期:2013-04-01 00:00:00

  • Effects of maximum aggregate size on UPV of brick aggregate concrete.

    abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.006

    authors: Mohammed TU,Mahmood AH

    更新日期:2016-07-01 00:00:00

  • The echocardiophone: a new means for observing spatial movement of the heart.

    abstract::The paper describes a new pocket size instrument called the "Cardiophone" for the diagnosis of cardiac dysfunction. It is a continuous wave swept frequency ultrasonic echo-location system which produces dynamic auditory signals corresponding to the positional change of internal structures of the heart. The four valves...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90031-2

    authors: Kay L,Boys J,Clark G,Mason J

    更新日期:1977-05-01 00:00:00

  • Ultrasonic spectroscopy of pure cyclic compounds.

    abstract::Ultrasonic studies of the group of halogens of benzene and particularly dependence of acoustic parameters on the structure of organic liquids, demonstrate some interesting regularities in the group of these compounds in gas and liquid states. In this paper results for five cyclic liquids: bromo-, chloro-, fluoro- and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.146

    authors: Linde BB,Lezhnev NB

    更新日期:2006-12-22 00:00:00

  • Thickness-shear and thickness-twist modes in an AT-cut quartz acoustic wave filter.

    abstract::We studied thickness-shear and thickness-twist vibrations of a monolithic, two-pole crystal filter made from a plate of AT-cut quartz. The scalar differential equations derived by Tiersten and Smythe for electroded and unelectroded quartz plates were employed which are valid for both the fundamental and the overtone m...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.003

    authors: Zhao Z,Qian Z,Wang B,Yang J

    更新日期:2015-04-01 00:00:00

  • Microparticle manipulation in millimetre scale ultrasonic standing wave chambers.

    abstract::Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 microns diameter latex microparticles and 5 microns diameter yeast in the chambers has been elucidated. One (flow) chamber had a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(98)00019-5

    authors: Hawkes JJ,Barrow D,Coakley WT

    更新日期:1998-08-01 00:00:00

  • Phase-space topography characterization of nonlinear ultrasound waveforms.

    abstract::Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinea...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.12.007

    authors: Dehghan-Niri E,Al-Beer H

    更新日期:2018-03-01 00:00:00

  • Nonlinear surface acoustic waves: realization of solitary pulses and fracture.

    abstract::A laser-based technique for the contact-free generation and detection of strongly nonlinear surface acoustic wave (SAW) pulses with amplitudes limited by the materials strength has been developed. The effects of nonlinear propagation of short elastic surface pulses with finite strength in isotropic solids, such as fus...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.06.002

    authors: Lomonosov AM,Hess P

    更新日期:2008-11-01 00:00:00

  • Lamb wave propagation in a plate with a grooved surface with several spatial periodicities.

    abstract::In order to investigate non-destructively the bonding between rough plates, the problem of Lamb waves propagating on a rough plate is addressed in this paper. Numerical analysis is performed on periodical gratings made of identical triangular grooves. If the surface profile is made up of grooves with one periodicity, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.052

    authors: Leduc D,Morvan B,Hladky AC,Pareige P,Izbicki JL

    更新日期:2006-12-22 00:00:00

  • Transient displacement induced in shear wave elastography: comparison between analytical results and ultrasound measurements.

    abstract::It is now accepted that an effective way to investigate the elastic properties of soft tissues is to generate a localized transient acoustic radiation force and to follow the associated displacements in the time/space domain. Shear waves induced by this stress field are particularly interesting in this kind of medium ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.022

    authors: Elkateb Hachemi M,Callé S,Remenieras JP

    更新日期:2006-12-22 00:00:00

  • A multiscale poromicromechanical approach to wave propagation and attenuation in bone.

    abstract::Ultrasonics is an important diagnostic tool for bone diseases, as it allows for non-invasive assessment of bone tissue quality through mass density-elasticity relationships. The latter are, however, quite complex for fluid-filled porous media, which motivates us to develop a rigorous multiscale poromicrodynamics appro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.12.005

    authors: Morin C,Hellmich C

    更新日期:2014-07-01 00:00:00

  • Spatiotemporal mapping of surface acoustic waves in isotropic and anisotropic materials.

    abstract::We demonstrate a new method for a real-time imaging of surface acoustic waves at frequencies up to 1 GHz with picosecond temporal and micron spatial resolutions using an ultrafast optical pump and probe technique combined with a common path interferometer. Using samples with isotropic or anisotropic substrates coated ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00090-2

    authors: Sugawara Y,Wright OB,Matsuda O,Gusev VE

    更新日期:2002-05-01 00:00:00

  • Eight-channel ultrasonic device for non-invasive quality evaluation in packed milk.

    abstract::An eight-channel ultrasonic detecting device for microbiological quality evaluation of packed liquid foods is presented in this paper. This device makes possible a non-invasive detection of the microbial growth in liquid foods with no need to open the carton-based packages where they are contained. Thermal and humidit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.011

    authors: Elvira L,Sampedro L,Montero de Espinosa F,Matesanz J,Gómez-Ullate Y,Resa P,Echevarría FJ,Iglesias JR

    更新日期:2006-12-01 00:00:00

  • Design of ultrasonic wedge transducer.

    abstract::Cones and wedges inserted between an ultrasonic transducer and the specimen provide the transducer (circular or rectangular shape) with enhanced capability for point or line contact with the specimen. Such an arrangement is useful in that the transducer can be used for transmitting to and receiving from a point (or li...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.10.002

    authors: Rus G,Wooh SC,Gallego R

    更新日期:2005-03-01 00:00:00

  • Application of low intensity ultrasonics to cheese manufacturing processes.

    abstract::Ultrasound has been used to non-destructively assess the quality of many foods such as meat, fish, vegetables and dairy products. This paper addresses the applications of low intensity ultrasonics in the cheese manufacturing processes and highlights the areas where ultrasonics could be successfully implemented in the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00085-9

    authors: Benedito J,Carcel JA,Gonzalez R,Mulet A

    更新日期:2002-05-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00