Abstract:
MOTIVATION:Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. OBJECTIVES:Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. METHODS:The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. RESULTS AND DISCUSSION:The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. CONCLUSIONS:The developed research interface can aid researchers in the rapid testing and clinical evaluation of new ultrasound algorithms and applications. Additionally, we believe that our approach would be applicable to designing research interfaces on other ultrasound machines.
journal_name
Ultrasonicsjournal_title
Ultrasonicsauthors
Shamdasani V,Bae U,Sikdar S,Yoo YM,Karadayi K,Managuli R,Kim Ydoi
10.1016/j.ultras.2007.11.009subject
Has Abstractpub_date
2008-07-01 00:00:00pages
159-68issue
3eissn
0041-624Xissn
1874-9968pii
S0041-624X(07)00123-0journal_volume
48pub_type
杂志文章相关文献
ULTRASONICS文献大全abstract::Ultrasonic non-destructive testing of polycrystalline structures can be disturbed by scattering at grain boundaries. Understanding and modeling this so-called "structural noise" is crucial for characterization as well as detection purposes. Structural noise can be considered as a fingerprint of the material under inve...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.06.012
更新日期:2014-01-01 00:00:00
abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105968
更新日期:2019-11-01 00:00:00
abstract::Elasticity assessment based on bulk wave velocity (BWV) measurements is the most popular technique to characterize the anisotropic stiffness tensor in cortical bone. Typically, a cuboid bone specimen is cut with its sides along the different anatomical directions. Then, the velocity of shear and longitudinal waves pro...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.05.009
更新日期:2017-09-01 00:00:00
abstract::Arterial stiffness has been shown to be a good indicator of arterial wall disease. However, a single parameter is insufficient to describe the complex stress-strain relationship of a multi-component, non-linear tissue such as the aorta. We therefore propose a new approach to measure the stress-strain relationship loca...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2010.01.003
更新日期:2010-06-01 00:00:00
abstract::The properties of optical to acoustic transduction of semiconductor superlattices have been explored for several years in the sub terahertz frequency range. Using femtosecond laser pulses focused on these structures, acoustic modes are excited with a frequency related to the periodicity of the structure stacking. We h...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.07.009
更新日期:2015-02-01 00:00:00
abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.05.003
更新日期:2005-01-01 00:00:00
abstract::Since the identification of micro-cracks in engineering materials is very valuable in understanding the initial and slight changes in mechanical properties of materials under complex working environments, numerical simulations on the propagation of the low frequency S0 Lamb wave in thin plates with randomly distribute...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.04.004
更新日期:2017-08-01 00:00:00
abstract::The objective of this paper is to present recent investigations in characteristics of the sound field generated by neurosurgical endoscopic ultrasonic probes (NEUPs) for minimally invasive surgery. The importance of this information has been investigated and discussed taking into account following facts: 1. According ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00217-2
更新日期:2002-05-01 00:00:00
abstract::Measurements of elastic constants of the austenite phase when approaching the phase transformation either upon cooling or stressing is of the crucial interest for the shape memory alloy field. Acoustic properties (wave velocity and also attenuation changes) of the Cu-Al-Ni single crystal were investigated in situ duri...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.029
更新日期:2004-04-01 00:00:00
abstract::The electromagnetic acoustic transducers (EMATs) with a meander-line coil possess the capability of generating Lamb waves carrying multiple wavelengths, and the characteristics of multiple wavelengths is analyzed by developing a spatial transversal filter model for the EMAT. It is shown that the characteristics is due...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2013.09.003
更新日期:2014-02-01 00:00:00
abstract::The paper investigates the existence of interfacial (Stoneley-type) acoustic waves localised at the internal boundary between two semi-infinite superlattices which are adjoined with each other to form one-dimensional phononic bicrystal. Each superlattice is a periodic sequence of perfectly bonded homogeneous and/or fu...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2020.106237
更新日期:2021-01-01 00:00:00
abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.105975
更新日期:2019-11-01 00:00:00
abstract::The paper deals with the study of the resonances of 1D periodic media composed of N elementary cells formed with two perfectly bonded layers which exhibit a high acoustic impedance contrast. In the case of a periodic bilayer structure constituted of a fluid layer and an elastic plate, it was shown in previous theoreti...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2012.11.011
更新日期:2013-03-01 00:00:00
abstract::A coordinated theoretical, numerical and experimental study is carried out in an effort to interpret the characteristics of propagating guided Lamb wave modes in presence of a high-density (HD) core region in a honeycomb composite sandwich structure (HCSS). Initially, a two-dimensional (2D) semi-analytical model based...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.05.025
更新日期:2016-09-01 00:00:00
abstract::A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predomina...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2014.05.001
更新日期:2014-09-01 00:00:00
abstract::A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.12.008
更新日期:2017-04-01 00:00:00
abstract::An ultrasonic technique for imaging nonlinear scatterers, such as partially-closed cracks, buried in a medium has been recently proposed. The method called fundamental wave amplitude difference (FAD) consists of a sequence of acquisitions with different subsets of elements for each line of the image. An image revealin...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.02.003
更新日期:2019-07-01 00:00:00
abstract::In many ultrasound applications-especially in the area of medical diagnostics-conventional sensors and particularly piezoelectric hydrophones do not comply with the requirements for "point detectors". It therefore suggests itself to develop methods, which allow ultrasonic fields to be reconstructed from the spatially ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/s0041-624x(02)00346-3
更新日期:2002-08-01 00:00:00
abstract::A nonlinear ultrasonic method is proposed based on a group of newly discovered wave triplets where two primary codirectional shear-horizontal SH0 waves mix in a weakly nonlinear plate and generate a cumulative S0 Lamb wave at the sum frequency. Theoretical analyses show that any combination of two primary SH0 waves wh...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2019.04.001
更新日期:2019-07-01 00:00:00
abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.056
更新日期:2006-12-22 00:00:00
abstract::In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2011.12.006
更新日期:2012-07-01 00:00:00
abstract::Experimental results of ultrasound of varying frequency (0.8-5.0 MHz) propagating in cold drawn wires of stainless steel and aluminium ranging in diameter from 0.25 to 1.21 mm are in close agreement with theoretical predictions. This agreement is maintained when the coupling medium between the wire and the ultrasound ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/0041-624x(89)90021-8
更新日期:1989-03-01 00:00:00
abstract::In this study, we present a model study of guided wave dispersion and resonance behavior of an array of piezoelectric plates with arbitrary cross-sections. The objective of this work is to analyze the influence of the geometry of an element of a 1D-array ultrasound transducer on generating multi-resonance frequency so...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.08.006
更新日期:2010-03-01 00:00:00
abstract::In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2016.11.008
更新日期:2017-03-01 00:00:00
abstract::The paper presents the characteristics of vertically polarized surface waves generated in silicon substrate by acoustic coupling of bulk waves excited in a periodically patterned ZnO film on silicon. The finite element simulations are performed on the proposed patterned-ZnO/Si structure and vertically polarized modes ...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2015.01.008
更新日期:2015-05-01 00:00:00
abstract::Electromagnetic-acoustic transducers (EMATs) consist of a magnet and a coil. They are advantageous in some non-destructive evaluation (NDE) applications because no direct contact with the specimen is needed to send and receive ultrasonic waves. However, EMATs commonly require excitation peak powers greater than 1kW an...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2017.02.009
更新日期:2017-07-01 00:00:00
abstract::The remote inspection for defects in large metallic elements such as pipes, tubes and plates is a field where guided waves are being applied with success. There are a number of situations where a surface coating is added for corrosion protection or insulation purposes. Since the coating materials are usually viscoelas...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.01.072
更新日期:2004-04-01 00:00:00
abstract::The Lamb waves are used for the ultrasonic characterization of welds because of their relative long-range propagation. In this paper, a simplified model of a weld-strip between two identical semi-infinite elastic layers is investigated. The reflected and transmitted ultrasonic fields are expressed by modal series whos...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2004.11.004
更新日期:2005-06-01 00:00:00
abstract::An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. Thi...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2006.05.107
更新日期:2006-12-22 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Acoustic scattering properties of ultrasound contrast agents are useful in extending existing or developing new techniques for biomedical imaging applications. A useful first step in this direction is to investigate the acoustic scattering of a new class of acoustic beams, known as helicoidal h...
journal_title:Ultrasonics
pub_type: 杂志文章
doi:10.1016/j.ultras.2009.09.003
更新日期:2010-03-01 00:00:00