New nonlinear ultrasonic method for material characterization: Codirectional shear horizontal guided wave mixing in plate.

Abstract:

:A nonlinear ultrasonic method is proposed based on a group of newly discovered wave triplets where two primary codirectional shear-horizontal SH0 waves mix in a weakly nonlinear plate and generate a cumulative S0 Lamb wave at the sum frequency. Theoretical analyses show that any combination of two primary SH0 waves whose frequencies sum to the frequency at which the SH0 mode intersects the S0 Lamb wave mode results in an internally resonant secondary S0 Lamb wave. Moreover, the relationship between the frequency combination and the nonlinear Lamb wave generation efficiency is revealed, which guides further engineering applications. Finite element validations are carried out with the aid of a subtraction method for the nonlinear feature extraction. The cumulative effect of the generated S0 Lamb wave at the sum frequency as well as the influence of the frequency combinations on the nonlinear Lamb wave generation efficiency is confirmed. Experiments are performed to validate the proposed method as well as demonstrate its use for material characterization. The experiments require a gel filter to mitigate the influence of the undesired nonlinear sources. With the gel filter, the cumulative effect of the secondary S0 Lamb wave is verified and the corresponding slope is extracted and further used to characterize the material status of the fatigue samples. Results demonstrate the proposed method provides high sensitivity to early fatigue damage, which makes it promising for the further early damage detection applications.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Shan S,Hasanian M,Cho H,Lissenden CJ,Cheng L

doi

10.1016/j.ultras.2019.04.001

subject

Has Abstract

pub_date

2019-07-01 00:00:00

pages

64-74

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(18)30714-5

journal_volume

96

pub_type

杂志文章
  • A general model of the axle vibration in piezoelectric motors.

    abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.080

    authors: Iula A,Pappalardo M

    更新日期:2004-04-01 00:00:00

  • Acoustically assisted removal of nitrogen oxide from high temperature flue gas.

    abstract::The present study focuses on a possibility for improving NO removal efficiency from flue gas by application of powerful sound waves. The sound waves (frequency 6.9-17.2kHz, intensity 144-160dB) are propagated from Hartmann sound generators to a preheated graphite disk inside a vertical reaction tube (height 1.8m, I.D....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.010

    authors: Komarov SV,Nemeth S,Hirasawa M

    更新日期:2005-02-01 00:00:00

  • Sensitivity to point-spread function parameters in medical ultrasound image deconvolution.

    abstract::Clinical ultrasound images are often perceived as difficult to interpret due to image blurring and speckle inherent in the ultrasound imaging. But the image quality can be improved by deconvolution using an estimate of the point-spread function. However, it is difficult to obtain a sufficiently accurate estimate of th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.005

    authors: Shin HC,Prager R,Ng J,Gomersall H,Kingsbury N,Treece G,Gee A

    更新日期:2009-03-01 00:00:00

  • Lamb wave propagation in a plate with a grooved surface with several spatial periodicities.

    abstract::In order to investigate non-destructively the bonding between rough plates, the problem of Lamb waves propagating on a rough plate is addressed in this paper. Numerical analysis is performed on periodical gratings made of identical triangular grooves. If the surface profile is made up of grooves with one periodicity, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.052

    authors: Leduc D,Morvan B,Hladky AC,Pareige P,Izbicki JL

    更新日期:2006-12-22 00:00:00

  • Extended optical theorem for scalar monochromatic acoustical beams of arbitrary wavefront in cylindrical coordinates.

    abstract::One of the fundamental theorems in (optical, acoustical, quantum, gravitational) wave scattering is the optical theorem for plane waves, which relates the extinction cross-section to the forward scattering complex amplitude function. In this analysis, the optical theorem is extended for the case of 3D-beams of arbitra...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.006

    authors: Mitri FG

    更新日期:2016-04-01 00:00:00

  • Acousto-optic interaction with leaky surface acoustic waves in Y-cut LiTaO3 crystals.

    abstract::The acousto-optic interaction with leaky surface acoustic wave radiation into the bulk of YX-cut LiTaO(3) crystals has been investigated. The light incidence and diffraction angles corresponding to the strongest acousto-optic interaction were calculated and measured as functions of the acoustic wave frequency. The dep...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.12.004

    authors: Belovickis J,Rimeika R,Ciplys D

    更新日期:2012-07-01 00:00:00

  • Optimization of electrode size for aluminum-nitride matrix ultrasonic transducers in the frequency range above 200 MHz.

    abstract::This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-n...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.10.018

    authors: Wei Y,Herzog T,Heuer H

    更新日期:2013-03-01 00:00:00

  • 1-60 MHz measurements in focused acoustic fields using spatial averaging corrections.

    abstract::The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00166-x

    authors: Radulescu EG,Lewin PA,Nowicki A

    更新日期:2002-05-01 00:00:00

  • Microparticle manipulation in millimetre scale ultrasonic standing wave chambers.

    abstract::Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 microns diameter latex microparticles and 5 microns diameter yeast in the chambers has been elucidated. One (flow) chamber had a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(98)00019-5

    authors: Hawkes JJ,Barrow D,Coakley WT

    更新日期:1998-08-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • Automatic dynamic range adjustment for ultrasound B-mode imaging.

    abstract::In medical ultrasound imaging, dynamic range (DR) is defined as the difference between the maximum and minimum values of the displayed signal to display and it is one of the most essential parameters that determine its image quality. Typically, DR is given with a fixed value and adjusted manually by operators, which l...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.09.012

    authors: Lee Y,Kang J,Yoo Y

    更新日期:2015-02-01 00:00:00

  • Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.04.001

    authors: Kim KB,Hsu DK,Ahn B,Kim YG,Barnard DJ

    更新日期:2010-08-01 00:00:00

  • In vivo characterization of the aortic wall stress-strain relationship.

    abstract::Arterial stiffness has been shown to be a good indicator of arterial wall disease. However, a single parameter is insufficient to describe the complex stress-strain relationship of a multi-component, non-linear tissue such as the aorta. We therefore propose a new approach to measure the stress-strain relationship loca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.003

    authors: Danpinid A,Luo J,Vappou J,Terdtoon P,Konofagou EE

    更新日期:2010-06-01 00:00:00

  • Piezoelectric linear motor concepts based on coupling of longitudinal vibrations.

    abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.056

    authors: Hemsel T,Mracek M,Twiefel J,Vasiljev P

    更新日期:2006-12-22 00:00:00

  • Two approaches to multiple specular echo detection using split spectrum processing: moving bandwidth minimization and mathematical morphology.

    abstract::A split spectrum processing technique using a novel moving bandwidth minimization (MBM) method was developed to detect multiple specular targets having different spectral characteristics. Mathematical morphology (MM) algorithms were also implemented in order to compare the results. An experimental approach to optimal ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00024-4

    authors: Grevillot M,Cudel C,Meyer JJ,Jacquey S

    更新日期:1999-09-01 00:00:00

  • An improved approximation for the Rayleigh wave equation.

    abstract::We derive a simple expression, which gives an approximate value of the Rayleigh wave velocity in an isotropic solid. This approximation is five times better than that given by Viktorov. The velocity equation can be easily inverted in order to obtain an accurate determination of the elastic constants. This procedure ca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.006

    authors: Royer D,Clorennec D

    更新日期:2007-03-01 00:00:00

  • A novel ultrasonic micro-dissection technique for biomedicine.

    abstract::Molecular techniques are transforming our understanding of cellular function and disease. However, accurate molecular analysis methods will be limited if the input DNA, RNA, or protein is not derived from pure population of cells or is contaminated by the wrong cells. A novel Ultrasonic Vibration Micro-dissection (UVM...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.010

    authors: Sun L,Wang H,Chen L,Liu Y

    更新日期:2006-12-22 00:00:00

  • Time-varying prediction filter for structural noise reduction in ultrasonic NDE.

    abstract::Predominant physical phenomenon in highly scattering materials is the attenuation due to dispersion. Therefore, received echo has high frequencies more severely attenuated than low frequencies and the structural noise can be modeled as a non-stationary random process. Most of the proposed techniques for enhancing the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.174

    authors: Izquierdo MA,Hernández MG,Anaya JJ

    更新日期:2006-12-22 00:00:00

  • Numerical simulation of electromagnetic acoustic transducers using distributed point source method.

    abstract::In spite of many advances in analytical and numerical modeling techniques for solving different engineering problems, an efficient solution technique for wave propagation modeling of an electromagnetic acoustic transducer (EMAT) system is still missing. Distributed point source method (DPSM) is a newly developed semi-...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.12.003

    authors: Eskandarzade M,Kundu T,Liebeaux N,Placko D,Mobadersani F

    更新日期:2010-05-01 00:00:00

  • Coating thickness affects surface stress measurement of brush electro-plating nickel coating using Rayleigh wave approach.

    abstract::A surface ultrasonic wave approach was presented for measuring surface stress of brush electro-plating nickel coating specimen, and the influence of coating thickness on surface stress measurement was discussed. In this research, two Rayleigh wave transducers with 5MHz frequency were employed to collect Rayleigh wave ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.02.003

    authors: Liu B,Dong S,Xu B,He P

    更新日期:2012-09-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Ultrasonic measurements on poroelastic slabs: determination of reflection and transmission coefficients and processing for Biot input parameters.

    abstract::Ultrasonic reflection and transmission measurements on saturated, plane-parallel, poroelastic slabs are presented. A data processing technique is proposed to obtain poroelastic parameters from transmission measurements. A special experimental data acquisition and processing technique is applied to minimize the finite ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.10.006

    authors: Jocker J,Smeulders D

    更新日期:2009-03-01 00:00:00

  • Development of disposable membrane hydrophones for a frequency range from 1MHz to 10MHz.

    abstract::A method for fabricating disposable membrane hydrophones is presented. The disposable hydrophones are intended for onetime use in such damaging environments as chemically contaminating fluids and high-amplitude (peak amplitude ∼100MPa) shock wave fields, where the use of commercial membrane hydrophones is not recommen...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.016

    authors: Lee JW,Ohm WS,Kim YT

    更新日期:2017-11-01 00:00:00

  • A new optical method for the detection of in-plane motion of ultrasound propagating in metals.

    abstract::This paper describes a laser optical technique for the detection of in-plane (IP) motion of ultrasonic waves propagating in solids. This interference-based laser optical technique includes a tiny square indentation with a width of about 30 microm on the sample surface and a relatively simple optical arrangement. The c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.076

    authors: Yang CH,Tsai YC

    更新日期:2006-12-22 00:00:00

  • Solder joint failure localization of welded joint based on acoustic emission beamforming.

    abstract::A localization approach of welded joint damage is proposed based on acoustic emission (AE) beamforming. In this method, a uniform line array is introduced to detect the AE signal of welded joints in specified area. In order to investigate the influence of fillet and crimping commonly existing in a welded plate structu...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.002

    authors: Liu X,Xiao D,Shan Y,Pan Q,He T,Gao Y

    更新日期:2017-02-01 00:00:00

  • Surface and friction characterization by thermoelectric measurements during ultrasonic friction processes

    abstract::Even though friction is one of the oldest problems in physics many aspects of friction processes are not clear today. We present an experimental setup, which permits the study of tribological systems by measuring the dissipated heat at the interface of two surfaces during a friction process with a time resolution of 1...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00062-1

    authors: Schwaller P,Groning P,Schneuwly A,Boschung P,Muller E,Blanc M,Schlapbach L

    更新日期:2000-03-01 00:00:00

  • Comparison of two methods of treatment for intraluminal thermal ablation using an ultrasound cylindrical phased array.

    abstract::Intraluminal (within the alimentary tract) thermal surgery has been shown to be a useful therapeutic option when extracorporeal focused ultrasound applicators cannot be used since their beam may not reach the target site. If plane transducers are used for the treatment of alimentary tract tumours, the applicator must ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.088

    authors: Melodelima D,Prat F,Birer A,Theillère Y,Cathignol D

    更新日期:2004-04-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • Architectures for ultrasonic planetary sample retrieval tools.

    abstract::Traditional rotary corers and sample retrieval mechanisms for planetary drilling suffer from a variety of technical difficulties. A heavy and rigid drillstring must be assembled on-site and deployed with considerable applied preload and torque, and these mechanical loadings are difficult to react in a low gravity envi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.06.001

    authors: Harkness P,Lucas M,Cardoni A

    更新日期:2011-12-01 00:00:00

  • Surface vibrational modes in disk-shaped resonators.

    abstract::The natural frequencies and distributions of displacement components for the surface vibrational modes in thin isotropic elastic disks are calculated. In particular, the research is focused on even solutions for low-lying resonant vibrations with large angular wave numbers. Several families of modes are found which ar...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.11.002

    authors: Dmitriev AV,Gritsenko DS,Mitrofanov VP

    更新日期:2014-03-01 00:00:00