Waveguides in medical ultrasonics: an experimental study of mode propagation.

Abstract:

:Experimental results of ultrasound of varying frequency (0.8-5.0 MHz) propagating in cold drawn wires of stainless steel and aluminium ranging in diameter from 0.25 to 1.21 mm are in close agreement with theoretical predictions. This agreement is maintained when the coupling medium between the wire and the ultrasound source is a short distance of water. Similar measurements for brass and copper wires are in less close agreement with theory due, probably, to the effect of greater anisotropy.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Nicholson NC,McDicken WN,Anderson T

doi

10.1016/0041-624x(89)90021-8

subject

Has Abstract

pub_date

1989-03-01 00:00:00

pages

101-6

issue

2

eissn

0041-624X

issn

1874-9968

pii

0041-624X(89)90021-8

journal_volume

27

pub_type

杂志文章
  • Ultrasonic flaw detection using threshold modified S-transform.

    abstract::Interference noising originating from the ultrasonic testing defect signal seriously influences the accuracy of the signal extraction and defect location. Time-frequency analysis methods are mainly used to improve the defects detection resolution. In fact, the S-transform, a hybrid of the Short time Fourier transform ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.004

    authors: Benammar A,Drai R,Guessoum A

    更新日期:2014-02-01 00:00:00

  • Application of low intensity ultrasonics to cheese manufacturing processes.

    abstract::Ultrasound has been used to non-destructively assess the quality of many foods such as meat, fish, vegetables and dairy products. This paper addresses the applications of low intensity ultrasonics in the cheese manufacturing processes and highlights the areas where ultrasonics could be successfully implemented in the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00085-9

    authors: Benedito J,Carcel JA,Gonzalez R,Mulet A

    更新日期:2002-05-01 00:00:00

  • Numerical predictions and experiments on the free-plate edge mode.

    abstract::In this paper, te edge mode variation is studied with three different methods: the reciprocal work method, already used by Torvik [J. Acoust. Soc. Am. 41 (1967) 346] to model this phenomenon, the S-parameter method and a finite element model that are applied for the first time to the study of the edge resonance. Moreo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00391-8

    authors: Le Clezio E,Predoi MV,Castaings M,Hosten B,Rousseau M

    更新日期:2003-01-01 00:00:00

  • Visualization of surface acoustic wave scattering by dislocations.

    abstract::Stroboscopic X-ray topography at the synchrotron beam line was used to visualize the propagation of a 580 MHz surface acoustic waves (SAW) in LiNbO3 crystals. For this purpose, the X-ray bursts coming from the synchrotron storage ring with periodicity of 5.68 MHz were synchronized with the SAW frequency in a phase-loc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00232-9

    authors: Shilo D,Zolotoyabko E

    更新日期:2002-05-01 00:00:00

  • State-of-the-art surface acoustic wave linear motor and its future applications

    abstract::Two merits of the surface acoustic wave (SAW) device are its high energy density and small size. However, the driving frequency is around 10 MHz or higher. In spite of the difficulties involved with high frequency, the high energy density is attractive for actuator applications. The SAW linear motor's no load speed an...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00087-6

    authors: Kurosawa MK

    更新日期:2000-03-01 00:00:00

  • Nonlinear surface acoustic waves: realization of solitary pulses and fracture.

    abstract::A laser-based technique for the contact-free generation and detection of strongly nonlinear surface acoustic wave (SAW) pulses with amplitudes limited by the materials strength has been developed. The effects of nonlinear propagation of short elastic surface pulses with finite strength in isotropic solids, such as fus...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.06.002

    authors: Lomonosov AM,Hess P

    更新日期:2008-11-01 00:00:00

  • Temperature prediction of ultrasonic vibration-assisted milling.

    abstract::Machining temperature is a key factor in ultrasonic vibration-assisted milling as it can significantly influence tool wear rate and residual thermal stresses. In current study, a physics-based analytical predictive model on machining temperature in ultrasonic vibration-assisted milling is proposed, without resorting t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106212

    authors: Feng Y,Hsu FC,Lu YT,Lin YF,Lin CT,Lin CF,Lu YC,Liang SY

    更新日期:2020-12-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • Development of disposable membrane hydrophones for a frequency range from 1MHz to 10MHz.

    abstract::A method for fabricating disposable membrane hydrophones is presented. The disposable hydrophones are intended for onetime use in such damaging environments as chemically contaminating fluids and high-amplitude (peak amplitude ∼100MPa) shock wave fields, where the use of commercial membrane hydrophones is not recommen...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.016

    authors: Lee JW,Ohm WS,Kim YT

    更新日期:2017-11-01 00:00:00

  • Adaptive filtering for reduction of speckle in ultrasonic pulse-echo images.

    abstract::Current medical ultrasonic scanning instrumentation permits the display of fine image detail (speckle) which does not transfer useful information but degrades the apparent low contrast resolution in the image. An adaptive two-dimensional filter has been developed which uses local features of image texture to recognize...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(86)90072-7

    authors: Bamber JC,Daft C

    更新日期:1986-01-01 00:00:00

  • Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy.

    abstract::In order to guide the needle to the correct location in 3D US-guided brachytherapy, the needle is continuously tracked as it is being inserted. A pre-scan before the needle insertion and a post-scan after the needle insertion are subtracted to obtain a difference image containing the needle. The image is projected alo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.003

    authors: Ding M,Wei Z,Gardi L,Downey DB,Fenster A

    更新日期:2006-12-22 00:00:00

  • Effect of wood properties on within-tree variation in ultrasonic wave velocity in softwood.

    abstract::The radial variations in the velocity of longitudinal waves propagating through Japanese cedar and Japanese cypress were experimentally investigated. In addition, the tracheid length (TL), microfibril angle (MFA), air-dried density (AD), and moisture content (MC) were measured in order to determine the effect of wood ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.10.001

    authors: Hasegawa M,Takata M,Matsumura J,Oda K

    更新日期:2011-04-01 00:00:00

  • Induction of stress fibres and intercellular gaps in human vascular endothelium by shock-waves.

    abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(94)90111-2

    authors: Seidl M,Steinbach P,Wörle K,Hofstädter F

    更新日期:1994-09-01 00:00:00

  • Experimental and numerical study of evanescent waves in the mini stopband of a 1D phononic crystal.

    abstract::This paper deals with the analysis of the guided evanescent waves in stopbands of a 1D phononic crystal (PC). A new numerical implementation is shown in order to get the complex values of the wavenumbers in a frequency range where a gap occurs. The considered phononic system is an aluminum plate with a one-dimensional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.09.009

    authors: Bavencoffe M,Morvan B,Hladky-Hennion AC,Izbicki JL

    更新日期:2013-02-01 00:00:00

  • A reverse time migration-based multistep angular spectrum approach for ultrasonic imaging of specimens with irregular surfaces.

    abstract::We develop a new ultrasonic imaging framework for non-destructive testing of an immersed specimen featuring an irregular top surface and demonstrate its capability of accurately depicting the lower surfaces of multiple damages hidden in the specimen. Central to the framework is a multistep angular spectrum approach (A...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106233

    authors: Yang X,Wang K,Xu Y,Xu L,Hu W,Wang H,Su Z

    更新日期:2020-12-01 00:00:00

  • Miniaturization of surface acoustic waves rotary motor.

    abstract::This paper presents the experimental study of a miniaturized surface acoustic waves (SAWs) rotary motor and the theoretical calculation. After the first success in SAW rotary motor operating at 9.85 MHz, a smaller rotary motor is designed. With the operating frequency of 30 MHz and the driving voltage of 120 V(p-p), t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00264-0

    authors: Cheng LP,Zhang GM,Zhang SY,Yu J,Shui XJ

    更新日期:2002-06-01 00:00:00

  • A new optical method for the detection of in-plane motion of ultrasound propagating in metals.

    abstract::This paper describes a laser optical technique for the detection of in-plane (IP) motion of ultrasonic waves propagating in solids. This interference-based laser optical technique includes a tiny square indentation with a width of about 30 microm on the sample surface and a relatively simple optical arrangement. The c...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.076

    authors: Yang CH,Tsai YC

    更新日期:2006-12-22 00:00:00

  • Comparison of two methods of treatment for intraluminal thermal ablation using an ultrasound cylindrical phased array.

    abstract::Intraluminal (within the alimentary tract) thermal surgery has been shown to be a useful therapeutic option when extracorporeal focused ultrasound applicators cannot be used since their beam may not reach the target site. If plane transducers are used for the treatment of alimentary tract tumours, the applicator must ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.088

    authors: Melodelima D,Prat F,Birer A,Theillère Y,Cathignol D

    更新日期:2004-04-01 00:00:00

  • Nondestructive evaluation of steel-concrete composite structure using high-frequency ultrasonic guided wave.

    abstract::Steel-concrete modular construction is increasingly used in nuclear structure construction. Conventional nondestructive testing methods are not able to detect internal concrete defects because the thick concrete wall is covered by steel plates. An ultrasonic guided method is proposed to detect honeycombs and voids aro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106096

    authors: Sun H,Zhu J

    更新日期:2020-04-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Directivity pattern of neurosurgical endoscopic ultrasonic probes.

    abstract::The objective of this paper is to present recent investigations in characteristics of the sound field generated by neurosurgical endoscopic ultrasonic probes (NEUPs) for minimally invasive surgery. The importance of this information has been investigated and discussed taking into account following facts: 1. According ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00217-2

    authors: Stimac A,Ivancević B,Jambrosić K

    更新日期:2002-05-01 00:00:00

  • Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.

    abstract::Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.04.005

    authors: Zhai K,He Q,Li L,Ren Y

    更新日期:2017-09-01 00:00:00

  • 2D array design based on Fermat spiral for ultrasound imaging.

    abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.010

    authors: Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

    更新日期:2010-02-01 00:00:00

  • Microparticle manipulation in millimetre scale ultrasonic standing wave chambers.

    abstract::Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 microns diameter latex microparticles and 5 microns diameter yeast in the chambers has been elucidated. One (flow) chamber had a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(98)00019-5

    authors: Hawkes JJ,Barrow D,Coakley WT

    更新日期:1998-08-01 00:00:00

  • Fundamental wave amplitude difference imaging for detection and characterization of embedded cracks.

    abstract::An ultrasonic technique for imaging nonlinear scatterers, such as partially-closed cracks, buried in a medium has been recently proposed. The method called fundamental wave amplitude difference (FAD) consists of a sequence of acquisitions with different subsets of elements for each line of the image. An image revealin...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.02.003

    authors: Haupert S,Ohara Y,Carcreff E,Renaud G

    更新日期:2019-07-01 00:00:00

  • Acoustic scattering from complex elastic shells: visualization of S0, A0 and A waves

    abstract::Acoustic scattering phenomena from complex immersed elastic shells are studied by high-speed Schlieren visualization for spark-generated spherical quasi-Dirac excitations. The situations considered are air-filled cylindrical shells under normal insonification and air-filled cylindrical shells soldered at one end with ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00165-1

    authors: Derbesse L,Pernod P,Latard V V,Merlen A,Decultot D,Touraine N,Maze G

    更新日期:2000-03-01 00:00:00

  • Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.

    abstract::The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) memb...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00128-8

    authors: Wen FL,Yen CY,Ouyang M

    更新日期:2003-08-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • In vitro estimation of mean sound speed based on minimum average phase variance in medical ultrasound imaging.

    abstract::Effective receive beamforming in medical ultrasound imaging is important for enhancing spatial and contrast resolution. In current ultrasound receive beamforming, a constant sound speed (e.g., 1540m/s) is assumed. However, the variations of sound speed in soft tissues could introduce phase distortions, leading to degr...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.03.007

    authors: Yoon C,Lee Y,Chang JH,Song TK,Yoo Y

    更新日期:2011-10-01 00:00:00

  • Quantification of guided mode propagation in fractured long bones.

    abstract::Guided modes propagation in intact, fractured and healing long bone has drawn significant research interests. However, mode quantifications for the direct comparison are still necessary to address. The aim of the study is to analyze the mode interaction with a notch-fracture in the long bone and find quantitative ultr...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.015

    authors: Xu K,Liu D,Ta D,Hu B,Wang W

    更新日期:2014-07-01 00:00:00