The performance and design of ultrasonic vibration system for flexural mode.

Abstract:

:The matrix method for analyzing flexural vibration system is outlined. The displacement, stress and velocity gain of ultrasonic flexural vibration systems are investigated by transfer matrix method. A design method is given for flexural transducer and vibration system.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Zhou G

doi

10.1016/s0041-624x(00)00034-2

subject

Has Abstract

pub_date

2000-11-01 00:00:00

pages

979-84

issue

10

eissn

0041-624X

issn

1874-9968

pii

S0041624X00000342

journal_volume

38

pub_type

杂志文章
  • Dynamic modeling and experimental verification of a piezoelectric part feeder in a structure with parallel bimorph beams.

    abstract::The study is aimed to perform dynamic modeling of a part feeder powered by piezoelectric actuation. This part feeder consists mainly of a horizontal platform vibrated by a pair of parallel piezoelectric bimorph beams. Owing to intermittent impacts with the platform, the transported part on the platform is able to marc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.02.002

    authors: Chao PC,Shen CY

    更新日期:2007-06-01 00:00:00

  • Generation of microbubbles from hollow cylindrical ultrasonic horn.

    abstract::In this study, we found that microbubbles with diameters of less than 100μm can be easily generated by using a hollow cylindrical ultrasonic horn. Consecutive images of bubbles obtained by using high-speed and high-resolution cameras reveal that a capillary wave is formed on the gas-liquid interface under weak ultraso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.010

    authors: Makuta T,Suzuki R,Nakao T

    更新日期:2013-01-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • Development of a portable 3D ultrasound imaging system for musculoskeletal tissues.

    abstract::3D ultrasound is a promising imaging modality for clinical diagnosis and treatment monitoring. Its cost is relatively low in comparison with CT and MRI, no intensive training and radiation protection is required for its operation, and its hardware is movable and can potentially be portable. In this study, we developed...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.05.003

    authors: Huang QH,Zheng YP,Lu MH,Chi ZR

    更新日期:2005-01-01 00:00:00

  • A new analytic expression for fast calculation of the transient near and far field of a rectangular baffled piston.

    abstract::Essential to (cardiac) 3D ultrasound are 2D matrix array transducer technology and the associated (two-stage) beam forming. Given the large number of degrees of freedom and the complexity of this problem, simulation tools play an important role. Hereto, the impulse response (IR) method is commonly used. Unfortunately,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.12.014

    authors: Ortega A,Tong L,D'hooge J

    更新日期:2014-04-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • Some studies on evaluation of degradation in composite adhesive joints using ultrasonic techniques.

    abstract::Experimental and theoretical studies on degradation of composite-epoxy adhesive joints were carried out on samples having different interfacial and cohesive properties. Oblique incidence ultrasonic inspection of bonded joints revealed that degradation in the adhesive can be measured by significant variation in reflect...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.01.014

    authors: Vijaya Kumar RL,Bhat MR,Murthy CR

    更新日期:2013-08-01 00:00:00

  • Two approaches to multiple specular echo detection using split spectrum processing: moving bandwidth minimization and mathematical morphology.

    abstract::A split spectrum processing technique using a novel moving bandwidth minimization (MBM) method was developed to detect multiple specular targets having different spectral characteristics. Mathematical morphology (MM) algorithms were also implemented in order to compare the results. An experimental approach to optimal ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00024-4

    authors: Grevillot M,Cudel C,Meyer JJ,Jacquey S

    更新日期:1999-09-01 00:00:00

  • Optimum bubble temperature for the sonochemical production of oxidants.

    abstract::Numerical simulations of bubble oscillations in liquid water irradiated by an ultrasonic wave are performed for various acoustic amplitudes and various ambient pressures. In the numerical simulations, effect of non-equilibrium evaporation and condensation of water vapor at the bubble wall and that of chemical reaction...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.005

    authors: Yasui K,Tuziuti T,Iida Y

    更新日期:2004-04-01 00:00:00

  • Transverse (lateral) instantaneous force of an acoustical first-order Bessel vortex beam centered on a rigid sphere.

    abstract::In a recent report [F.G. Mitri, Z.E.A. Fellah, Ultrasonics 51 (2011) 719-724], it has been found that the instantaneous axial force (i.e. acting along the axis of wave propagation) of a Bessel acoustic beam centered on a sphere is only determined for the fundamental order (i.e. m=0) but vanishes when the beam is of vo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.07.009

    authors: Mitri FG,Fellah ZE

    更新日期:2012-01-01 00:00:00

  • Piezoelectric linear motor concepts based on coupling of longitudinal vibrations.

    abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.056

    authors: Hemsel T,Mracek M,Twiefel J,Vasiljev P

    更新日期:2006-12-22 00:00:00

  • In vivo characterization of the aortic wall stress-strain relationship.

    abstract::Arterial stiffness has been shown to be a good indicator of arterial wall disease. However, a single parameter is insufficient to describe the complex stress-strain relationship of a multi-component, non-linear tissue such as the aorta. We therefore propose a new approach to measure the stress-strain relationship loca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.003

    authors: Danpinid A,Luo J,Vappou J,Terdtoon P,Konofagou EE

    更新日期:2010-06-01 00:00:00

  • Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications.

    abstract::This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acousti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.04.001

    authors: Kim KB,Hsu DK,Ahn B,Kim YG,Barnard DJ

    更新日期:2010-08-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • Polymeric contrast agent with targeting potential.

    abstract::The Arg-Gly-Asp (RGD) peptide sequence was conjugated to poly (lactid acid), (PLA), microcapsules. These hollow, biodegradable PLGA microcapsules were developed in our laboratory for use as ultrasound contrast agents. By modifying the surface of the agent with a targeting ligand, it can be targeted to a specific addre...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.018

    authors: Lathia JD,Leodore L,Wheatley MA

    更新日期:2004-04-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • Applications of a nanocomposite-inspired in-situ broadband ultrasonic sensor to acousto-ultrasonics-based passive and active structural health monitoring.

    abstract::A novel nanocomposite-inspired in-situ broadband ultrasonic sensor previously developed, with carbon black as the nanofiller and polyvinylidene fluoride as the matrix, was networked for acousto-ultrasonic wave-based passive and active structural health monitoring (SHM). Being lightweight and small, this kind of sensor...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.007

    authors: Liu M,Zeng Z,Xu H,Liao Y,Zhou L,Zhang Z,Su Z

    更新日期:2017-07-01 00:00:00

  • Low- and high-frequency nonlinear acoustic phenomena in a magnesite.

    abstract::The results of experimental and theoretical studies of nonlinear acoustic phenomena (amplitude-dependent losses, resonant frequency shifts, damping of weak ultrasonic pulses and their carrier frequency phase delay under action of a powerful low-frequency pumping wave as well as amplitude-phase self-action of the finit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.07.008

    authors: Nazarov VE,Kolpakov AB

    更新日期:2014-02-01 00:00:00

  • An improved approximation for the Rayleigh wave equation.

    abstract::We derive a simple expression, which gives an approximate value of the Rayleigh wave velocity in an isotropic solid. This approximation is five times better than that given by Viktorov. The velocity equation can be easily inverted in order to obtain an accurate determination of the elastic constants. This procedure ca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.006

    authors: Royer D,Clorennec D

    更新日期:2007-03-01 00:00:00

  • Nitric oxide delivery by ultrasonic cracking: some limitations.

    abstract::Nitric oxide (NO) has been implicated in smooth muscle relaxation. Its use has been widespread in cardiology. Due to the effective scavenging of NO by hemoglobin, however, the drug has to be applied locally or in large quantities, to have the effect desired. We propose the use of encapsulated microbubbles that act as ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.003

    authors: Postema M,Bouakaz A,ten Cate FJ,Schmitz G,de Jong N,van Wamel A

    更新日期:2006-12-22 00:00:00

  • Potential of ultrasonic pulse velocity for evaluating the dimensional stability of oak and chestnut wood.

    abstract::The objective of this study was to examine the potential of ultrasonic velocity as a rapid and nondestructive method to predict the dimensional stability of oak (Quercus petraea (Mattuschka) Lieblein) and chestnut (Castanea sativa Mill.) that are commonly used in flooring industry. Ultrasonic velocity, specific gravit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.11.007

    authors: Dündar T,Wang X,As N,Avcı E

    更新日期:2016-03-01 00:00:00

  • SH ultrasonic guided waves for the evaluation of interfacial adhesion.

    abstract::Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.002

    authors: Castaings M

    更新日期:2014-09-01 00:00:00

  • Improving accuracy of acoustic source localization in anisotropic plates.

    abstract::The acoustic source localization technique for anisotropic plates proposed by the authors in an earlier publication ([1] Kundu et al., 2012) is improved in this paper by adopting some modifications. The improvements are experimentally verified on anisotropic flat and curved composite plates. Difficulties associated wi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.001

    authors: Nakatani H,Kundu T,Takeda N

    更新日期:2014-09-01 00:00:00

  • Experimental estimation of the viscous component of ultrasound attenuation in suspensions of bovine skeletal muscle myofibrils.

    abstract::It has been suggested that viscous losses, caused by the motion of myofibrils relative to their environmental fluid, could be the major cause of ultrasound attenuation in muscle. This Paper presents theoretical and experimental estimates of the viscous component of attenuation in suspensions of myofibrils. Experimenta...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(88)90046-7

    authors: Shore D,Miles CA

    更新日期:1988-01-01 00:00:00

  • A novel ultrasonic micro-dissection technique for biomedicine.

    abstract::Molecular techniques are transforming our understanding of cellular function and disease. However, accurate molecular analysis methods will be limited if the input DNA, RNA, or protein is not derived from pure population of cells or is contaminated by the wrong cells. A novel Ultrasonic Vibration Micro-dissection (UVM...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.010

    authors: Sun L,Wang H,Chen L,Liu Y

    更新日期:2006-12-22 00:00:00

  • Microbubble-enhanced hemorrhage control using high intensity focused ultrasound.

    abstract::Our objective was to investigate whether hemorrhage control can be achieved faster when high-intensity focused ultrasound (HIFU) is applied in the presence of ultrasound contrast agents (UCA) as compared to HIFU only application. Incisions (3 cm long and 0.5 cm deep) were produced in the livers of anesthetized rabbits...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.018

    authors: Zderic V,Brayman AA,Sharar SR,Crum LA,Vaezy S

    更新日期:2006-12-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Temperature prediction of ultrasonic vibration-assisted milling.

    abstract::Machining temperature is a key factor in ultrasonic vibration-assisted milling as it can significantly influence tool wear rate and residual thermal stresses. In current study, a physics-based analytical predictive model on machining temperature in ultrasonic vibration-assisted milling is proposed, without resorting t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106212

    authors: Feng Y,Hsu FC,Lu YT,Lin YF,Lin CT,Lin CF,Lu YC,Liang SY

    更新日期:2020-12-01 00:00:00

  • Design and dynamic evaluation for a linear ultrasonic stage using the thin-disc structure actuator.

    abstract::The design of a novel, single-axis ultrasonic actuating stage has been proposed. It consists of a movable plate, an edge-driving ultrasonic actuator as an actuating device, and a magnetic Magi encoder as a position sensor. The stage is impelled using a friction-contact mechanism by the ultrasonic actuator with long di...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.005

    authors: Wen F,Yen CY

    更新日期:2007-12-01 00:00:00

  • Bonding and impedance matching of acoustic transducers using silver epoxy.

    abstract::Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input im...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2011.11.010

    authors: Son KT,Lee CC

    更新日期:2012-04-01 00:00:00