Optimum bubble temperature for the sonochemical production of oxidants.

Abstract:

:Numerical simulations of bubble oscillations in liquid water irradiated by an ultrasonic wave are performed for various acoustic amplitudes and various ambient pressures. In the numerical simulations, effect of non-equilibrium evaporation and condensation of water vapor at the bubble wall and that of chemical reactions of gases and vapor inside a bubble are taken into account. The oxidants such as OH radicals, O radicals, H(2)O(2) molecules, and O(3) molecules are created from water vapor inside a heated bubble when a bubble collapses strongly. They are dispersed into the liquid and solutes are oxidized by the oxidants, which is called sonochemical reactions. The computer simulations have revealed that there exists the optimum bubble temperature, which is about 5500 K, for the production of the oxidants inside an air bubble because at higher bubble temperature the oxidants are strongly consumed inside a bubble by oxidizing nitrogen. Correspondingly, there exists an optimum acoustic amplitude for the production of the oxidants, which is about 2.2 atm when the ultrasonic frequency is 140 kHz and the ambient pressure is 1 atm. For an oxygen bubble, on the other hand, the amount of the oxidants created inside a bubble becomes nearly independent of the bubble temperature at the collapse above about 6000 K because nitrogen is absent.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Yasui K,Tuziuti T,Iida Y

doi

10.1016/j.ultras.2003.12.005

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

579-84

issue

1-9

eissn

0041-624X

issn

1874-9968

pii

S0041624X03002269

journal_volume

42

pub_type

杂志文章
  • Investigating the absolute phase information in acoustic wave resonance scattering.

    abstract::The aim of this work is to investigate the absolute phase information in resonance acoustic scattering by spheres and cylinders and place this work in the broader context of scattering in which the properties of the magnitude and (processed) phase have been examined in a more general way than in the classical resonanc...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.01.002

    authors: Mitri FG,Greenleaf JF,Fellah ZE,Fatemi M

    更新日期:2008-07-01 00:00:00

  • Speckle tracking for multi-dimensional flow estimation.

    abstract::Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages and limitations of two-dimensional algorithms that use a singl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00182-1

    authors: Bohs LN,Geiman BJ,Anderson ME,Gebhart SC,Trahey GE

    更新日期:2000-03-01 00:00:00

  • Non-linear actuation of cantilevers using giant magnetostrictive thin films

    abstract::In the present paper, we report the first results concerning a centimetre cantilever driven through non-linear effects in thin magnetostrictive films. Bimorph centimetre beams (24 mm x 5 mm) were designed using 160 microns thick glass and 0.4 micron thick multilayer TbFe/Fe films deposited via RF sputtering, using sev...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00061-x

    authors: Tiercelin N,Pernod P,Preobrazhensky V V,Le Gall H,Ben Youssef J

    更新日期:2000-03-01 00:00:00

  • SH ultrasonic guided waves for the evaluation of interfacial adhesion.

    abstract::Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.03.002

    authors: Castaings M

    更新日期:2014-09-01 00:00:00

  • Optimizing graphene production in ultrasonic devices.

    abstract::In this work, we investigate the efficiency of graphene production from graphite by ultrasonic-induced exfoliation under different operational conditions. An ultrasonic bath and an ultrasonic horn tip were used, to show how the graphene production efficiency depends on the acoustic intensity and cavitation mechanism u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105989

    authors: Silva LI,Mirabella DA,Pablo Tomba J,Riccardi CC

    更新日期:2020-01-01 00:00:00

  • Axial vibration characteristics of a cylindrical, radially polarized piezoelectric transducer with different electrode patterns.

    abstract::A circular cylindrical piezoelectric transducer with radial polarization is proposed. The axial vibration characteristics of the transducer are studied by three different methods: analytical calculation, FEM simulation and experiment. The symmetric and asymmetric excitation conditions are discussed in the Haskins and ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.008

    authors: Sun D,Wang S,Hata S,Shimokohbe A

    更新日期:2010-03-01 00:00:00

  • Design and dynamic evaluation for a linear ultrasonic stage using the thin-disc structure actuator.

    abstract::The design of a novel, single-axis ultrasonic actuating stage has been proposed. It consists of a movable plate, an edge-driving ultrasonic actuator as an actuating device, and a magnetic Magi encoder as a position sensor. The stage is impelled using a friction-contact mechanism by the ultrasonic actuator with long di...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.005

    authors: Wen F,Yen CY

    更新日期:2007-12-01 00:00:00

  • Peculiarities of energy trapping of the UHF elastic waves in diamond-based piezoelectric layered structure. II. Lateral energy flow.

    abstract::Features of an acoustic energy trapping and outflow in a High-overtone Bulk Acoustic Resonator (HBAR) were considered. On the example of a specified resonator based on a piezoelectric layered structure (PLS) as "Al/AlN/Mo/(100) diamond", the simulation of the propagation of microwave acoustic waves in the range of 10-...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106311

    authors: Kvashnin GM,Sorokin BP

    更新日期:2021-03-01 00:00:00

  • A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound.

    abstract::Elasticity assessment based on bulk wave velocity (BWV) measurements is the most popular technique to characterize the anisotropic stiffness tensor in cortical bone. Typically, a cuboid bone specimen is cut with its sides along the different anatomical directions. Then, the velocity of shear and longitudinal waves pro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.009

    authors: Peralta L,Cai X,Laugier P,Grimal Q

    更新日期:2017-09-01 00:00:00

  • Tissue characterization of arteries with 4 MHz ultrasound.

    abstract::Reflections of 4 MHz ultrasound pulses from 60 sites on 15 human aorta specimens were analysed using the plane-wave Born approximation (PWBA) inverse scattering method. The recovered high-resolution acoustic impedance profile for each site was correlated with an analysis (by microscope) of sections taken from that sit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(95)00025-x

    authors: Tobocman W,Santosh K,Carter JR,Haacke EM

    更新日期:1995-07-01 00:00:00

  • Ultrasonic evaluation of microwave-induced thermal lesions based on wavelet analysis of mean scatterer spacing.

    abstract::The microwave ablation has become an important manner for tumor treatment. In this paper, we proposed a new method for evaluation of microwave-induced thermal lesions using the wavelet analysis of the mean scatterer spacing (MSS). First, the ultrasonic radiofrequency (RF) data of normal and coagulated porcine liver ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.03.018

    authors: Zhou Z,Sheng L,Wu S,Yang C,Zeng Y

    更新日期:2013-09-01 00:00:00

  • Arbitrary scattering of an acoustical high-order Bessel trigonometric (non-vortex) beam by a compressible soft fluid sphere.

    abstract::The present analysis extends the previous work on the axial acoustic scattering of a high-order Bessel trigonometric beam (HOBTB) from a fluid sphere [F.G. Mitri, J. Appl. Phys. 109 (2011) 014916] to the generalized case of arbitrary scattering from a fluid sphere placed off-axially. The scattered pressure is expresse...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.008

    authors: Mitri FG

    更新日期:2013-07-01 00:00:00

  • Guided wave mode selection for inhomogeneous elastic waveguides using frequency domain finite element approach.

    abstract::This article describes the use of the frequency domain finite element (FDFE) technique for guided wave mode selection in inhomogeneous waveguides. Problems with Rayleigh-Lamb and Shear-Horizontal mode excitation in isotropic homogeneous plates are first studied to demonstrate the application of the approach. Then, two...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.12.007

    authors: Chillara VK,Ren B,Lissenden CJ

    更新日期:2016-04-01 00:00:00

  • Attenuation estimation by repeatedly solving the forward scattering problem.

    abstract::Estimation of the attenuation is important in medical ultrasound not only for correct time-gain compensation but also for tissue characterization. In this paper, the feasibility of a new method for attenuation estimation is tested. The proposed method estimates the attenuation by repeatedly solving the forward wave pr...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.10.008

    authors: Ilyina N,Hermans J,Verboven E,Van Den Abeele K,D'Agostino E,D'hooge J

    更新日期:2018-03-01 00:00:00

  • How many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols.

    abstract::The purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 3...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.005

    authors: Choi SH,Jeong WK,Kim Y,Lim S,Kwon JW,Kim TY,Kim MY,Sohn JH

    更新日期:2016-12-01 00:00:00

  • Dynamic interrogator for elastic wave sensing using Fabry Perot filters based on fiber Bragg gratings.

    abstract::Use of in-fiber Fabry-Perot (FP) filters based on fiber Bragg gratings as both sensor as well as an interrogator for enhancing the detection limit of elastic wave sensing is investigated in this paper. The sensitivity of such a demodulation scheme depends on the spectral discrimination of the sensor and interrogator g...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.02.018

    authors: Harish AV,Varghese B,Rao B,Balasubramaniam K,Srinivasan B

    更新日期:2015-07-01 00:00:00

  • The wavelet response as a multiscale characterization of scattering processes at granular interfaces.

    abstract::We perform a multiscale analysis of the backscattering properties of a complex interface between water and a layer of randomly arranged glass beads with diameter D=1 mm. An acoustical experiment is done to record the wavelet response of the interface in a large frequency range from lambda/D=0.3 to lambda/D=15. The wav...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.212

    authors: Le Gonidec Y,Gibert D

    更新日期:2006-11-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • Imaging microbubbles and tissues using a linear focussed scanner operating at 20 MHz: possible implications for the detection of cavitation thresholds.

    abstract::B-Scan images have been used as a means of detecting the onset of cavitation in tissues. New echoes appearing during simultaneous sonication with therapeutic ultrasound have often been attributed to bubble formation. In this study temperature rises up to 15 degrees C W-1 cm2 in guinea pig leg (post-mortem) were found,...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(91)90028-7

    authors: Watmough DJ,Davies HM,Quan KM,Wytch R,Williams AR

    更新日期:1991-07-01 00:00:00

  • Impact of localized inhomogeneity on the surface-wave velocity and bulk-wave reflection in solids.

    abstract::The effect of a weak surface, near-surface and interfacial inhomogeneity on the frequency dependence of the surface wave velocity and of the SH (shear horizontal) wave reflectivity in isotropic elastic media is studied analytically and numerically. The inhomogeneity is modeled as an infinite planar layer with continuo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.001

    authors: Baron C,Shuvalov AL,Poncelet O

    更新日期:2007-03-01 00:00:00

  • Sparsity-based beamforming to enhance two-dimensional linear-array photoacoustic tomography.

    abstract::In linear-array photoacoustic imaging (PAI), beamforming methods can be used to reconstruct the images. Delay-and-sum (DAS) beamformer is extensively used due to its simple implementation. However, this algorithm results in high level of sidelobes and low resolution. In this paper, it is proposed to form the photoacou...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.03.010

    authors: Paridar R,Mozaffarzadeh M,Periyasamy V,Pramanik M,Mehrmohammadi M,Orooji M

    更新日期:2019-07-01 00:00:00

  • Sparse representation for Lamb-wave-based damage detection using a dictionary algorithm.

    abstract::Lamb waves are being investigated extensively for structural health monitoring (SHM) because of their characteristics of traveling long distances with little attenuation and sensitivity to minor local damage in structures. However, Lamb waves are dispersive, which results in the complex overlap of waveforms in the dam...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.02.011

    authors: Wang W,Bao Y,Zhou W,Li H

    更新日期:2018-07-01 00:00:00

  • Guided wave propagation in a honeycomb composite sandwich structure in presence of a high density core.

    abstract::A coordinated theoretical, numerical and experimental study is carried out in an effort to interpret the characteristics of propagating guided Lamb wave modes in presence of a high-density (HD) core region in a honeycomb composite sandwich structure (HCSS). Initially, a two-dimensional (2D) semi-analytical model based...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.05.025

    authors: Sikdar S,Banerjee S

    更新日期:2016-09-01 00:00:00

  • High-intensity ultrasound irradiation promotes the release of extracellular vesicles from C2C12 myotubes.

    abstract::Skeletal muscle is an important secretory organ in mammals, producing myriad chemical mediators ("myokines") with distinct biological action in different tissues, including anti-inflammatory activity. Extracellular vesicles (EVs) have recently been identified as a mode of myokine transport from muscle, facilitating su...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106243

    authors: Maeshige N,Langston PK,Yuan ZM,Kondo H,Fujino H

    更新日期:2021-02-01 00:00:00

  • Identification of material properties of orthotropic elastic cylinders immersed in fluid using vibroacoustic techniques.

    abstract::A numerical study is presented to show the potential for using vibroacoustic-based experiments to identify elastic material properties of orthotropic cylindrical vessels immersed in fluids. Sensitivity analyses and a simulated inverse problem are shown to quantify the potential for material characterization through th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.07.004

    authors: Rosario DE,Brigham JC,Aquino W

    更新日期:2008-11-01 00:00:00

  • Bolt axial stress measurement based on a mode-converted ultrasound method using an electromagnetic acoustic transducer.

    abstract::A method is proposed to measure the stress on a tightened bolt using an electromagnetic acoustic transducer (EMAT). A shear wave is generated by the EMAT, and a longitudinal wave is obtained from the reflection of the shear wave due to the mode conversion. The ray paths of the longitudinal and the shear wave are analy...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.11.003

    authors: Ding X,Wu X,Wang Y

    更新日期:2014-03-01 00:00:00

  • Sonothrombolysis with magnetic microbubbles under a rotational magnetic field.

    abstract::Thrombosis is an extremely critical clinical condition where a clot forms inside a blood vessel which blocks the blood flow through the cardiovascular system. Previous sonothrombolysis methods using ultrasound and microbubbles (MBs) often have a relatively low lysis rate due to the low microbubbles concentration at cl...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.06.004

    authors: Zhang B,Kim H,Wu H,Gao Y,Jiang X

    更新日期:2019-09-01 00:00:00

  • On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent.

    abstract::The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(97)00137-6

    authors: Bouakaz A,de Jong N,Cachard C,Jouini K

    更新日期:1998-02-01 00:00:00

  • Three-dimensional modelling of micromachined-ultrasonic-transducer arrays operating in water.

    abstract::We report on the 3-D modelling of periodic arrays of capacitive micromachined ultrasonic transducers (cMUTs) operating in fluid. Specific developments have been performed to model biperiodic transducer arrays and to take into account radiation into any stratified media at the front-side as well as the back-side of the...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.09.006

    authors: Wilm M,Reinhardt A,Laude V,Armati R,Daniau W,Ballandras S

    更新日期:2005-05-01 00:00:00

  • Piezoelectric linear motor concepts based on coupling of longitudinal vibrations.

    abstract::Classically, rotary motors with gears and spindle mechanisms are used to achieve translatory motion. In means of miniaturization and weight reduction piezoelectric linear motors are of interest. Several ultrasonic linear motors found in literature base on the use of two different vibration modes. Most often flexural a...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.056

    authors: Hemsel T,Mracek M,Twiefel J,Vasiljev P

    更新日期:2006-12-22 00:00:00