SH ultrasonic guided waves for the evaluation of interfacial adhesion.

Abstract:

:Shear-Horizontally (SH) polarized, ultrasonic, guided wave modes are considered in order to infer changes in the adhesive properties at several interfaces located within an adhesive bond joining two metallic plates. Specific aluminium lap-joint samples were produced, with different adhesive properties at up to four interfaces when a glass-epoxy film is inserted into the adhesive bond. EMAT transducers were used to generate and detect the fundamental SH0 mode. This is launched from one plate and detected at the other plate, past the lap joint. Signals are picked up for different propagation paths along each sample, in order to check measurement reproducibility as well as the uniformity of the adhesively bonded zones. Signals measured for four samples are then compared, showing very good sensitivity of the SH0 mode to changes in the interfacial adhesive properties. In addition, a Finite Element-based model is used to simulate the experimental measurements. The model includes adhesive viscoelasticity, as well as spatial distributions of shear springs (with shear stiffness KT) at both metal-adhesive interfaces, and also at the adhesive-film interfaces when these are present. This model is solved in the frequency domain, but temporal excitation and inverse FFT procedure are implemented in order to simulate the measured time traces. Values of the interfacial adhesive parameters, KT, are determined by an optimization process so that best fit is obtained between both sets of measured and numerically predicted waveforms. Such agreement was also possible by adjusting the shear modulus of the adhesive component. This work suggests a promising use of SH-like guided modes for quantifying shear properties at adhesive interfaces, and shows that such waves can be used for inferring adhesive and cohesive properties of bonds separately. Finally, the paper considers improvements that could be made to the process, and its potential for testing the interfacial adhesion of adhesively bonded composite components.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Castaings M

doi

10.1016/j.ultras.2014.03.002

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

1760-75

issue

7

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(14)00057-2

journal_volume

54

pub_type

杂志文章
  • A theoretical analysis of a piezoelectric ultrasound device with an active matching layer.

    abstract::This paper investigates the use of magnetically active materials in the matching layer of a piezoelectric transducer. This then allows the performance of the device to be dynamically altered by applying an external field. The effect that this new matching layer has on the performance of a typical device is theoretical...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.08.002

    authors: Mulholland AJ,O'Leary RL,Ramadas N,Parr A,Troge A,Pethrick RA,Hayward G

    更新日期:2007-12-01 00:00:00

  • A study of the noncollinear ultrasonic-wave-mixing technique under imperfect resonance conditions.

    abstract::Geometrical and material property changes cause deviations in the resonant conditions used for noncollinear wave mixing. These deviations are predicted and observed using the SV(ω1)+L(ω2)→L(ω1+ω2) interaction, where SV and L are the shear vertical and longitudinal waves, respectively, and ω1, ω2 are their frequencies....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.11.009

    authors: Demčenko A,Mainini L,Korneev VA

    更新日期:2015-03-01 00:00:00

  • Generation of transversal envelope soliton in polymeric and wooden rods.

    abstract::This paper is concerned with the probing of the transversal envelope solitons propagation in circular waveguides when a set of requirements (non-linearity and dispersion) are fulfilled in the waveguide and balanced. The basic idea is to analyze the shape of an acoustic pulse after it has traveled one or few trips thro...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.016

    authors: de Billy M,Hladky-Hennion AC

    更新日期:2014-07-01 00:00:00

  • Research on adaptive temperature control in sound field induced by self-focused concave spherical transducer.

    abstract::Temperature control of hyperthermia treatments is generally implemented with multipoint feedback system comprised of phased-array transducer, which is complicated and high cost. Our simulations to the acoustic field induced by a self-focused concave spherical transducer (0.5MHz, 9cm aperture width, 8.0cm focal length)...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2010.01.006

    authors: Hu J,Qian S,Ding Y

    更新日期:2010-05-01 00:00:00

  • Aperture and element minimization in linear sparse arrays with desired beam patterns

    abstract::In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is proposed that is based on the stochastic optimization methodology called simulated annealing. Such a method optimizes the positions and the weight coefficients of each element of a linear array in order to obtain a beam pattern ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00089-x

    authors: Trucco A

    更新日期:2000-03-01 00:00:00

  • Effect of the microstructure on the propagation velocity of ultrasound in magnetic powders.

    abstract::We analyze experimentally and theoretically the sound propagation velocity of P-waves in granular media made of micrometer-size magnetite particles under an external magnetic field. The sound velocity is measured in a coherent (long-wavelength) regime of propagation after a controlled sample preparation consisting of ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.021

    authors: Botello FR,Quintanilla MAS,Castellanos A,Grekova EF,Tournat V

    更新日期:2018-01-01 00:00:00

  • The nonlinear S0 Lamb mode in a plate with a linearly-varying thickness.

    abstract::The aim of this paper is to investigate propagation characteristics and the generation mechanism of the nonlinear lowest-order symmetric Lamb mode (S0) which propagates downslope in free elastic plates with slowly linearly varying-thickness. From theoretical analyses, in a low frequency-thickness product (fd) range, t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.11.013

    authors: Hu Z,An Z,Kong Y,Lian G,Wang X

    更新日期:2019-04-01 00:00:00

  • Effect of carrier and particle concentration on ultrasound properties of magnetic nanofluids.

    abstract::Ultrasound wave propagation in nanofluids and its rheological behavior has been studied as a function of solid volume fraction, temperature and magnetic field for magnetic nanofluids synthesized in kerosene and transformer oil. Ultrasonic velocity decreases while viscosity increases with increasing volume fraction. Th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.08.017

    authors: Patel JK,Parekh K

    更新日期:2015-01-01 00:00:00

  • Inversion of synthetic and experimental acoustical scattering data for the comparison of two reconstruction methods employing the Born approximation.

    abstract::This work is concerned with the reconstruction, from measured (synthetic or real) data, of a 2D penetrable fluid-like object of arbitrary cross-section embedded in a fluid of infinite extent and insonified by a plane acoustic wave. Green's theorem is used to provide a domain integral representation of the scattered fi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00054-8

    authors: Guillermin R,Lasaygues P,Sessarego JP,Wirgin A

    更新日期:2001-03-01 00:00:00

  • Generation of a torsion wave and measuring its propagation velocity in the circumferential direction of arterial wall.

    abstract::Increased stiffness of the arteries has recently gained acceptance as a potential risk for cardiovascular and many other diseases. Pulse wave velocity (PWV) is widely used for estimating the stiffness of an artery. However, PWV is an indicator of average artery stiffness between two measuring points. In addition to me...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.054

    authors: Zhang X,Greenleaf JF

    更新日期:2006-12-22 00:00:00

  • Ultrasonic drawing of tungsten wire for incandescent lamps production.

    abstract::An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.02.002

    authors: Mordyuk BN,Mordyuk VS,Buryak VV

    更新日期:2004-04-01 00:00:00

  • Numerical and experimental analysis of strongly nonlinear standing acoustic waves in axisymmetric cavities.

    abstract::In this paper the behaviour of strongly nonlinear waves in axisymmetric resonators is experimentally and numerically studied. Experiments are carried out in a cylindrical cavity, which transversal dimension is bigger than the longitudinal one, excited by a narrow band transducer. The quality factor and displacement am...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.02.001

    authors: Vanhille C,Campos-Pozuelo C

    更新日期:2005-08-01 00:00:00

  • A general model of the axle vibration in piezoelectric motors.

    abstract::In the present work a general model of the vibrational behavior of the axle of a piezoelectric motor is proposed. In this motor, a cylinder-shaped permanent magnet, which act as a rotor, is pressed in contact with an end of a steel axle by means of the magnetic forces. The other end of the axle is fitted at the center...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.01.080

    authors: Iula A,Pappalardo M

    更新日期:2004-04-01 00:00:00

  • Design and dynamic evaluation for a linear ultrasonic stage using the thin-disc structure actuator.

    abstract::The design of a novel, single-axis ultrasonic actuating stage has been proposed. It consists of a movable plate, an edge-driving ultrasonic actuator as an actuating device, and a magnetic Magi encoder as a position sensor. The stage is impelled using a friction-contact mechanism by the ultrasonic actuator with long di...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.005

    authors: Wen F,Yen CY

    更新日期:2007-12-01 00:00:00

  • Convolutional neural network for ultrasonic weldment flaw classification in noisy conditions.

    abstract::Ultrasonic flaw classification in weldment is an active area of research and many artificial intelligence approaches have been applied to automate this process. However, in the industrial applications, the ultrasonic flaw signals are not noise free and automatic intelligent defect classification algorithms show relati...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.12.001

    authors: Munir N,Kim HJ,Park J,Song SJ,Kang SS

    更新日期:2019-04-01 00:00:00

  • The effect of the conductivity of a film located near a piezoelectric resonator with a lateral electric field based on the PZT ceramics on its characteristics.

    abstract::In this paper, we investigated theoretically and experimentally the effect of the conductivity of the film located in the immediate vicinity of the free side of a piezoelectric resonator based on the PZT ceramics on its characteristics. It is shown that with increasing the conductivity of the film at first the paralle...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2018.09.016

    authors: Zaitsev BD,Semyonov AP,Teplykh AA,Borodina IA

    更新日期:2019-04-01 00:00:00

  • Modal analysis and moving performance of a single-mode linear ultrasonic motor.

    abstract::A single-mode linear ultrasonic motor was developed in this study. On the stator, a group of four pieces of piezoelectric ceramics PZT8 were utilized to generate the ultrasonic vibration. A specially designed modal conversion horn with an oblique beam was applied to transfer the longitudinal vibration to an additional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106216

    authors: Yin Z,Dai C,Cao Z,Li W,Chen Z,Li C

    更新日期:2020-12-01 00:00:00

  • How many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols.

    abstract::The purpose of this study is to evaluate whether a 5-repetition liver stiffness (LS) measurement as the standard protocol of shear wave elastography (SWE) is comparable to a conventional 10-repetition measurement protocol and to identify factors that influence the reliability of the 5-repetition protocol. A total of 3...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.08.005

    authors: Choi SH,Jeong WK,Kim Y,Lim S,Kwon JW,Kim TY,Kim MY,Sohn JH

    更新日期:2016-12-01 00:00:00

  • Ultrasonic monitoring of film condensation for applications in reduced gravity

    abstract::The film condensation of vapor on a cooled, downward-facing surface is a complex dynamic fluid phenomenon. This paper will describe the theoretical basis, instrumentation approach, and experimental results for a method for ultrasonic monitoring of film condensation. The ultrasound measurement system utilizes a 10 MHz ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00214-0

    authors: Pedersen PC,Cakareski Z,Hermanson JC

    更新日期:2000-03-01 00:00:00

  • Nonlinear Coda Wave Interferometry: Sensitivity to wave-induced material property changes analyzed via numerical simulations in 2D.

    abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105968

    authors: Chen G,Pageot D,Abraham O,Zhang Y,Chekroun M,Tournat V

    更新日期:2019-11-01 00:00:00

  • A novel method for Estimating Time of Flight of ultrasonic echoes through short-time Fourier transforms.

    abstract::The accurate estimation of time of flight (TOF) of an ultrasonic signal is essential in ultrasonic non-destructive testing (NDT). A novel method for TOF estimation based on the short-time Fourier transform (STFT) is proposed in this paper. Firstly, the time and frequency components of ultrasonic echoes are represented...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106104

    authors: Lu Z,Ma F,Yang C,Chang M

    更新日期:2020-04-01 00:00:00

  • Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results.

    abstract::An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mech...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.024

    authors: Vannacci E,Granchi S,Belsito L,Roncaglia A,Biagi E

    更新日期:2017-03-01 00:00:00

  • A novel ultrasonic micro-dissection technique for biomedicine.

    abstract::Molecular techniques are transforming our understanding of cellular function and disease. However, accurate molecular analysis methods will be limited if the input DNA, RNA, or protein is not derived from pure population of cells or is contaminated by the wrong cells. A novel Ultrasonic Vibration Micro-dissection (UVM...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.06.010

    authors: Sun L,Wang H,Chen L,Liu Y

    更新日期:2006-12-22 00:00:00

  • Guided wave propagation in a honeycomb composite sandwich structure in presence of a high density core.

    abstract::A coordinated theoretical, numerical and experimental study is carried out in an effort to interpret the characteristics of propagating guided Lamb wave modes in presence of a high-density (HD) core region in a honeycomb composite sandwich structure (HCSS). Initially, a two-dimensional (2D) semi-analytical model based...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.05.025

    authors: Sikdar S,Banerjee S

    更新日期:2016-09-01 00:00:00

  • The echocardiophone: a new means for observing spatial movement of the heart.

    abstract::The paper describes a new pocket size instrument called the "Cardiophone" for the diagnosis of cardiac dysfunction. It is a continuous wave swept frequency ultrasonic echo-location system which produces dynamic auditory signals corresponding to the positional change of internal structures of the heart. The four valves...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(77)90031-2

    authors: Kay L,Boys J,Clark G,Mason J

    更新日期:1977-05-01 00:00:00

  • Induction of stress fibres and intercellular gaps in human vascular endothelium by shock-waves.

    abstract::Human umbilical cords were exposed to high amplitude focussed ultrasonic pulses with focal energy densities 0.6 and 0.4 mJ mm-2. The endothelium of the exposed vessel (vein) was examined by means of confocal laser scanning microscopy and scanning electron microscopy. The degree of tissue change ranged from the inducti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(94)90111-2

    authors: Seidl M,Steinbach P,Wörle K,Hofstädter F

    更新日期:1994-09-01 00:00:00

  • Simulation study of a chaotic cavity transducer based virtual phased array used for focusing in the bulk of a solid material.

    abstract::In acoustic and ultrasonic non-destructive testing techniques, it is sometimes beneficial to concentrate sound energy at a chosen location in space and at a specific instance in time, for example to improve the signal-to-noise ratio or activate the nonlinearity of damage features. Time Reversal (TR) techniques, taking...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.010

    authors: Delrue S,Van Den Abeele K,Bou Matar O

    更新日期:2016-04-01 00:00:00

  • Elastic constants of solids and fluids with initial pressure via a unified approach based on equations-of-state.

    abstract::The second and third-order Brugger elastic constants are obtained for liquids and ideal gases having an initial hydrostatic pressure p1. For liquids the second-order elastic constants are C₁₁=A+p₁, C₁₂=A-p₁, and the third-order constants are C₁₁₁=-(B+5A+3p₁), C₁₁₂=-(B+A-p₁), and C₁₂₃=A-B-p₁, where A and B are the Beye...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2014.01.012

    authors: Cantrell JH

    更新日期:2014-07-01 00:00:00

  • The computations of reflection coefficients of multilayer structure based on the reformulation of Thomson-Haskell method.

    abstract::A reformulation of the Thomson-Haskell method is presented for calculating the reflection coefficients of multilayer structure immersing in the coupling fluid. Instead of directly multiplying the layer propagator matrix, the new method splits the layer propagator matrix and excursively determines the interface stiffne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.08.004

    authors: Chen J,Bai X,Yang K,Ju BF

    更新日期:2012-12-01 00:00:00

  • Waveguides in medical ultrasonics: an experimental study of mode propagation.

    abstract::Experimental results of ultrasound of varying frequency (0.8-5.0 MHz) propagating in cold drawn wires of stainless steel and aluminium ranging in diameter from 0.25 to 1.21 mm are in close agreement with theoretical predictions. This agreement is maintained when the coupling medium between the wire and the ultrasound ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(89)90021-8

    authors: Nicholson NC,McDicken WN,Anderson T

    更新日期:1989-03-01 00:00:00