Mapping the human brain white matter tracts relative to cortical and deep gray matter using diffusion tensor imaging at high spatial resolution.

Abstract:

:The mapping of the human brain white matter fiber networks relative to deep subcortical and cortical gray matter requires high spatial resolution which is challenged by the low signal-to-noise ratio. The purpose of this short report was to introduce a whole brain high spatial resolution diffusion tensor imaging (DTI) protocol that enabled for the first time the mapping of corticopontocerebellar, frontostriatal and thalamofrontal fiber pathways in addition to other limbic, commissural, association and projection white matter pathways relative to the segmented deep gray (e.g., caudate nuclei) and the cortical lobes. Our DTI acquisition protocol and analysis strategy provide important template for brain-behavior research and for teaching brain mapping and are clinically affordable for patient comfort.

journal_name

Magn Reson Imaging

authors

Hasan KM,Kamali A,Kramer LA

doi

10.1016/j.mri.2008.10.007

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

631-6

issue

5

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(08)00338-X

journal_volume

27

pub_type

杂志文章
  • Data-driven curvilinear reconstructions of 3D MR images: application to cryptogenic extratemporal epilepsy.

    abstract::This paper presents a data-driven method for the reconstruction and visualisation of curvilinear slices from three-dimensional (3D) magnetic resonance (MR) scans of the head. Visualisation of curvilinear slices, rather than standard planar slices, produces symmetrical views of the cortex and allows small abnormalities...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00132-5

    authors: Musse O,Armspach JP,Namer IJ,Heitz F,Hennel F,Grucker D

    更新日期:1998-12-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Recreational runners with patellofemoral pain exhibit elevated patella water content.

    abstract::Increased bone water content resulting from repetitive patellofemoral joint overloading has been suggested to be a possible mechanism underlying patellofemoral pain (PFP). To date, it remains unknown whether persons with PFP exhibit elevated bone water content. The purpose of this study was to determine whether recrea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.018

    authors: Ho KY,Hu HH,Colletti PM,Powers CM

    更新日期:2014-09-01 00:00:00

  • Determination of blood circulation times of superparamagnetic iron oxide nanoparticles by T2* relaxometry using ultrashort echo time (UTE) MRI.

    abstract::Blood circulation is an important determinant of the biodistribution of superparamagnetic iron oxide nanoparticles. Here we present a magnetic resonance imaging (MRI) technique based on the use of ultrafast echo times (UTE) for the noninvasive determination of blood half-lives at high particle concentrations, when con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.017

    authors: Scharlach C,Warmuth C,Schellenberger E

    更新日期:2015-11-01 00:00:00

  • Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

    abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.013

    authors: Hargreaves BA,Bangerter NK,Shimakawa A,Vasanawala SS,Brittain JH,Nishimura DG

    更新日期:2006-02-01 00:00:00

  • A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain.

    abstract::In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliabl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.002

    authors: Zhang XY,Wang F,Afzal A,Xu J,Gore JC,Gochberg DF,Zu Z

    更新日期:2016-10-01 00:00:00

  • Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.002

    authors: Salvati R,Hitti E,Bellanger JJ,Saint-Jalmes H,Gambarota G

    更新日期:2016-06-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • A method for MR quantification of flow velocities in blood and CSF using interleaved gradient-echo pulse sequences.

    abstract::The aim of this study was to establish a rapid method for in vivo quantification of a large range of flow velocities using phase information. A basic gradient-echo sequence was constructed, in which flow was encoded along the slice selection direction by variation of the amplitude of a bipolar gradient without changes...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90535-3

    authors: Ståhlberg F,Mogelvang J,Thomsen C,Nordell B,Stubgaard M,Ericsson A,Sperber G,Greitz D,Larsson H,Henriksen O

    更新日期:1989-11-01 00:00:00

  • 3D MR image denoising using rough set and kernel PCA method.

    abstract::In this paper, we have presented a two stage method, using kernel principal component analysis (KPCA) and rough set theory (RST), for denoising volumetric MRI data. A rough set theory (RST) based clustering technique has been used for voxel based processing. The method groups similar voxels (3D cubes) using class and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.010

    authors: Phophalia A,Mitra SK

    更新日期:2017-02-01 00:00:00

  • Spectral pattern of total creatine and trimethyl ammonium in multiple sclerosis.

    abstract::Fatigue and impairment mobility are frequent problems in multiple sclerosis (MS). Despite its enormous potential, in vivo (1)H MRS of skeletal muscles for MS patients is a largely unexplored field. One fundamental question remains unanswered: whether MS can cause observable proton metabolite changes. High quality two-...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.005

    authors: Hu J,Xu Y,Jiang Q,Sehgal V,Shen Y,Xuan Y,Xia Y

    更新日期:2004-04-01 00:00:00

  • Preparation, physico-chemical characterization, and relaxometry studies of various gadolinium(III)-DTPA-bis(amide) derivatives as potential magnetic resonance contrast agents.

    abstract::Macroscopic protonation constants were measured for a series of DTPA mono- and bis-amide ligands using potentiometric titrations. Proton NMR pH titrations yielded protonation populations of the various nitrogen and oxygen basic sites of the ligands for the different protonation stages. Amide formation decreased the ba...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00117-l

    authors: Geraldes CF,Urbano AM,Alpoim MC,Sherry AD,Kuan KT,Rajagopalan R,Maton F,Muller RN

    更新日期:1995-01-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • Deep neural network inspired by iterative shrinkage-thresholding algorithm with data consistency (NISTAD) for fast Undersampled MRI reconstruction.

    abstract::With the aim of developing a fast algorithm for high-quality MRI reconstruction from undersampled k-space data, we propose a novel deep neural Network, which is inspired by Iterative Shrinkage Thresholding Algorithm with Data consistency (NISTAD). NISTAD consists of three consecutive blocks: an encoding block, which m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.016

    authors: Qiu W,Li D,Jin X,Liu F,Sun B

    更新日期:2020-07-01 00:00:00

  • Quantification of venous blood signal contribution to BOLD functional activation in the auditory cortex at 3 T.

    abstract::Most modern techniques for functional magnetic resonance imaging (fMRI) rely on blood-oxygen-level-dependent (BOLD) contrast as the basic principle for detecting neuronal activation. However, the measured BOLD effect depends on a transfer function related to neurophysiological changes accompanying electrical neural ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.006

    authors: Casciaro S,Bianco R,Distante A

    更新日期:2008-11-01 00:00:00

  • Study on the variations of the apparent diffusion coefficient in areas of solid tumor in high grade gliomas.

    abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00594-5

    authors: Muti M,Aprile I,Principi M,Italiani M,Guiducci A,Giulianelli G,Ottaviano P

    更新日期:2002-11-01 00:00:00

  • Noncontrast MRI with diffusion-weighted imaging as the sole imaging modality for detecting liver malignancy in patients with high risk for hepatocellular carcinoma.

    abstract:PURPOSE:To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease. MATERIALS AND METHODS:We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.021

    authors: Kim YK,Kim YK,Park HJ,Park MJ,Lee WJ,Choi D

    更新日期:2014-07-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • Voxel- and atlas-based analysis of diffusion tensor imaging may reveal focal axonal injuries in mild traumatic brain injury -- comparison with diffuse axonal injury.

    abstract:BACKGROUND:The diagnosis and management of mild traumatic brain injury (MTBI) continue to be subjects of debate, with varying opinions regarding the extent to which tissue-based impairments versus the impacts of other stressors cause ongoing disability. Detecting areas of the brain with abnormalities that can explain s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.018

    authors: Kasahara K,Hashimoto K,Abo M,Senoo A

    更新日期:2012-05-01 00:00:00

  • A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7T.

    abstract::Atherosclerotic plaques in the bifurcation of the carotid arteries can pose a significant health risk due to possible plaque rupture and subsequent stroke. The assessment of plaques, and evaluation of the risk they pose, can be performed with Black-Blood (BB) vessel wall magnetic resonance imaging. However, resolution...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.04.011

    authors: Papoutsis K,Li L,Near J,Payne S,Jezzard P

    更新日期:2017-07-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling.

    abstract:PURPOSE:To implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps. MATERIALS AND METHODS:3D EPI non-segmented acquisition with a pCASL ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.011

    authors: Gai ND,Chou YY,Pham D,Butman JA

    更新日期:2017-12-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • Dependence of BOLD signal change on tactile stimulus intensity in SI of primates.

    abstract::Recently, we have demonstrated that the fine-digit topography (millimeter sized) previously identified in the primary somatosensory cortex (SI), using electrophysiology and intrinsic signal optical imaging, can also be mapped with submillimeter resolution using blood-oxygenation-level-dependent (BOLD) functional magne...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.05.002

    authors: Zhang N,Gore JC,Chen LM,Avison MJ

    更新日期:2007-07-01 00:00:00

  • In vivo animal tests of an artifact-free contrast agent for gastrointestinal MRI.

    abstract::A variety of shortcomings are associated with most currently used gastrointestinal contrast agents for magnetic resonance imaging (MRI). Artifacts resulting from peristalsis and other motions in the abdominal region are produced by many positive contrast agents (which increase signal intensity). Although this is not a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00020-9

    authors: Briggs RW,Wu Z,Mladinich CR,Stoupis C,Gauger J,Liebig T,Ros PR,Ballinger JR,Kubilis P

    更新日期:1997-01-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Assessing image artifacts from radiotherapy electromagnetic transponders with metal-artifact reduction imaging.

    abstract::Image artifacts due to 14 gauge radiotherapy electromagnetic (EM) transponders were assessed on conventional spin echo images, and corrected using metal artifact reduction techniques: high bandwidth, view angle tilting (VAT), and slice encoding for metal artifact correction (SEMAC). Large areas of signal loss and/or p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.02.005

    authors: Bergen RV,Ryner L

    更新日期:2019-06-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00