Diffusion-weighted imaging or dynamic contrast-enhanced curve: a retrospective analysis of contrast-enhanced magnetic resonance imaging-based differential diagnoses of benign and malignant breast lesions.

Abstract:

OBJECTIVE:To compare the diagnostic performance of models based on a combination of contrast-enhanced (CE) magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) or time-intensity curves (TIC) in diagnosing malignancies of breast lesions. METHODS:A double-blind retrospective study was conducted in 328 patients (254 for training and the following 74 for validation) who underwent dynamic contrast-enhanced MRI (DCE-MRI) of the breast with pathological results. Two score models, the DWI model (apparent diffusion coefficient (ADC) + morphology + enhanced information) and the TIC model (TIC + morphology + enhanced information), were established with binary logistic regression for mass and non-mass enhancements (NMEs) in the training set. The sensitivity, specificity, and area under the curve (AUC) were compared between the two models (DWI model vs. TIC model); p < 0.05 was considered as statistically different. External validation was used. RESULTS:In the training set, the sensitivities, specificities, and AUCs of the DWI/TIC model were 95.2%/95.8%, 70.8%/47.9%, and 0.932/0.891 for masses, and 94.2%/90.4%, 47.4%/47.4%, and 0.798 (95% CI, 0.686-0.884)/0.802 (95% CI, 0.691-0.887) for NMEs, respectively. The AUC of the DWI model was significantly higher than that of the TIC model (p < 0.05) for masses. In the validation set, the AUCs of the DWI/TIC model were 0.896/0.861 for masses (p < 0.05) and 0.936/0.836 for NMEs (p > 0.05). CONCLUSIONS:Combined with CE MRI, the DWI model was superior or equal to the TIC model in differentiating benign and malignant breast lesions. KEY POINTS:• Diffusion magnetic resonance imaging played an important role in the diagnosis of breast neoplasms. • On the basis of contrast-enhanced MRI, the DWI model had significantly higher diagnostic ability than the TIC model in distinguishing benign and malignant masses. • It would be reasonable to replace the time-consuming TIC with DWI for less scan time and similar diagnostic efficiency.

journal_name

Eur Radiol

journal_title

European radiology

authors

Yang X,Dong M,Li S,Chai R,Zhang Z,Li N,Zhang L

doi

10.1007/s00330-020-06883-w

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

4795-4805

issue

9

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-06883-w

journal_volume

30

pub_type

杂志文章
  • Evaluation of iopentol (Imagopaque 350) in CT enhancement. A multi-centre monitoring trial assessing adverse events and diagnostic information--results from 1,823 patients in France.

    abstract:OBJECTIVES:To evaluate the safety and efficacy of iopentol 350 mg I/ml (Imagopaque/Ivépaque, Nycomed Imaging AS, Oslo, Norway), a monomeric non-ionic contrast medium for computed tomography, in a large population. To identify predictive factors for patient safety. MATERIALS AND METHODS:One thousand eight hundred and t...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/pl00006874

    authors: Oxaal M,Lambrechts M,Bunouf P,Menuet JF

    更新日期:1997-01-01 00:00:00

  • CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial.

    abstract::To assess both sensitivity and specificity of digital chest radiography alone and in conjunction with dual-exposure dual-energy chest radiography for the detection and classification of pulmonary nodules. One hundred patients with a total of 149 lung nodules (3-45 mm; median, 11 mm) confirmed by CT were included in th...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-008-0945-6

    authors: Rühl R,Wozniak MM,Werk M,Laurent F,Mager G,Montaudon M,Pattermann A,Scherrer A,Tasu JP,Pech M,Ricke J

    更新日期:2008-09-01 00:00:00

  • Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography.

    abstract::This was a radiologists' preference study to compare a digital chest radiography system that utilizes a large-area silicon flat-panel detector with conventional radiography for visualizing anatomic regions of the chest. Conventional and digital posteroanterior (PA) and lateral chest radiographs were obtained in 115 pa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000795

    authors: Hennigs SP,Garmer M,Jaeger HJ,Classen R,Jacobs A,Gissler HM,Christmann A,Mathias K

    更新日期:2001-01-01 00:00:00

  • Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes.

    abstract:OBJECTIVE:To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). METHODS:Thirty-eight patients with non-ST segment elevation myocardial in...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-010-1725-7

    authors: Schepis T,Achenbach S,Marwan M,Muschiol G,Ropers D,Daniel WG,Pflederer T

    更新日期:2010-07-01 00:00:00

  • The value of time-intensity curves obtained after microbubble contrast agent injection to discriminate responders from non-responders to anti-inflammatory medication among patients with Crohn's disease.

    abstract:OBJECTIVE:To assess the value of time-intensity curves obtained after sulphur hefluoride-filled microbubble contrast agent injection to discriminate responders from non-responders among patients with Crohn's disease (CD). METHODS:Forty-three patients (29 male and 14 female; mean age ± SD, 48.5 ± 17.17 years) with init...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2754-1

    authors: Quaia E,Cabibbo B,De Paoli L,Toscano W,Poillucci G,Cova MA

    更新日期:2013-06-01 00:00:00

  • Comparing dual energy CT and subtraction CT on a phantom: which one provides the best contrast in iodine maps for sub-centimetre details?

    abstract:OBJECTIVES:To compare contrast-to-noise ratios (CNRs) and iodine discrimination thresholds on iodine maps derived from dual energy CT (DECT) and subtraction CT (SCT). METHODS:A contrast-detail phantom experiment was performed with 2 to 15 mm diameter tubes containing water or iodinated contrast concentrations ranging ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5496-x

    authors: Baerends E,Oostveen LJ,Smit CT,Das M,Sechopoulos I,Brink M,de Lange F,Prokop M

    更新日期:2018-12-01 00:00:00

  • Hepatic cysts treated with percutaneous ethanol sclerotherapy: time to extend the indications to haemorrhagic cysts and polycystic liver disease.

    abstract:OBJECTIVES:To describe the long-term clinical and morphological outcome of symptomatic hepatic cysts treated with percutaneous ethanol sclerotherapy (PES). METHODS:From December 2003 to September 2011, all patients with hepatic cysts undergoing PES with a follow-up after 12 months were included. Evolution of the volum...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3117-x

    authors: Benzimra J,Ronot M,Fuks D,Abdel-Rehim M,Sibert A,Farges O,Vilgrain V

    更新日期:2014-05-01 00:00:00

  • Potentially relevant incidental findings on research whole-body MRI in the general adult population: frequencies and management.

    abstract:OBJECTIVES:To report the frequencies of potentially relevant incidental findings in the general adult population and to develop a protocol for their management in whole-body magnetic resonance imaging (wb-MRI). METHODS:A total of 2,500 adult subjects (1,271 women, 1,229 men; mean age 53 years) from the population-base...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2636-6

    authors: Hegenscheid K,Seipel R,Schmidt CO,Völzke H,Kühn JP,Biffar R,Kroemer HK,Hosten N,Puls R

    更新日期:2013-03-01 00:00:00

  • Radioembolisation with (90)Y-labelled resin microspheres in the treatment of liver metastasis from breast cancer.

    abstract:OBJECTIVES:Metastatic breast cancer is a heterogeneous disease, commonly affecting the liver. We report our experience with (90)Y radioembolisation (RE) and its effects on the survival of patients with treatment-refractory breast cancer liver metastases. METHODS:A total of 77 female patients affected by breast cancer ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2556-5

    authors: Cianni R,Pelle G,Notarianni E,Saltarelli A,Rabuffi P,Bagni O,Filippi L,Cortesi E

    更新日期:2013-01-01 00:00:00

  • Cystic versus predominantly cystic thyroid nodules: efficacy of ethanol ablation and analysis of related factors.

    abstract:OBJECTIVES:To compare the efficacy of ethanol ablation (EA) of cystic and predominantly cystic thyroid nodules, and to evaluate factors affecting efficacy. METHODS:From October 2008 to December 2010, a total of 217 thyroid nodules were treated with EA. Nodule volumes, symptoms and cosmetic scores were evaluated before...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2406-5

    authors: Kim YJ,Baek JH,Ha EJ,Lim HK,Lee JH,Sung JY,Kim JK,Kim TY,Kim WB,Shong YK

    更新日期:2012-07-01 00:00:00

  • Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.

    abstract:OBJECTIVES:We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). METHODS:One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB pha...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4026-3

    authors: Nakajima R,Abe K,Kondo T,Tanabe K,Sakai S

    更新日期:2016-06-01 00:00:00

  • Incidence and risk factors of early arterial blood flow stasis during first radioembolization of primary and secondary liver malignancy using resin microspheres: an initial single-center analysis.

    abstract:OBJECTIVES:To retrospectively determine incidence of early arterial blood flow stasis and its influencing factors during resin-based radioembolization (RE) of liver tumours. METHODS:Data of patients undergoing resin-based RE from 06/2006-12/2013 were reviewed. Second RE procedures of the same liver lobe were excluded....

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4076-6

    authors: Pieper CC,Willinek WA,Thomas D,Ahmadzadehfar H,Essler M,Nadal J,Wilhelm KE,Schild HH,Meyer C

    更新日期:2016-08-01 00:00:00

  • The PPRD score stratifies patients with hepatocellular carcinoma and portal vein tumor thrombus treated with sorafenib plus transarterial chemoembolization.

    abstract:OBJECTIVES:To identify clinical prognostic and predictive factors in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT) undergoing sorafenib plus transarterial chemoembolization (TACE) and establish a prognostic score for these patients. METHODS:Between January 2012 and December 2017, 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07078-z

    authors: Zhang Y,Miao H,Xie W,Jiang S,Song Z,Huang G,Fan W,Wang Y,Li J,Chen Y

    更新日期:2021-01-01 00:00:00

  • Early diffuse recurrence of hepatocellular carcinoma after percutaneous radiofrequency ablation: analysis of risk factors.

    abstract:OBJECTIVE:To evaluate the risk factors affecting early diffuse recurrence within 1 year of percutaneous ultrasound-guided radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). METHODS:Out of 146 patients who received transcatheter arterial chemoembolisation (TACE) for treatment of recurrent HCC after percu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2561-8

    authors: Lee HY,Rhim H,Lee MW,Kim YS,Choi D,Park MJ,Kim YK,Kim SH,Lim HK

    更新日期:2013-01-01 00:00:00

  • Automated computer-aided stenosis detection at coronary CT angiography: initial experience.

    abstract:OBJECTIVE:To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA). METHODS:We investigated 59 patients (38 men, mean age 58 +/- 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a softwar...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1644-7

    authors: Arnoldi E,Gebregziabher M,Schoepf UJ,Goldenberg R,Ramos-Duran L,Zwerner PL,Nikolaou K,Reiser MF,Costello P,Thilo C

    更新日期:2010-05-01 00:00:00

  • Tumour 18 F-FDG Uptake on preoperative PET/CT may predict axillary lymph node metastasis in ER-positive/HER2-negative and HER2-positive breast cancer subtypes.

    abstract:OBJECTIVES:To evaluate the association between tumour FDG uptake on preoperative PET/CT and axillary lymph node metastasis (ALNM) according to breast cancer subtype. METHODS:The records of 671 patients with invasive breast cancer who underwent (18) F-FDG PET/CT and surgery were reviewed. Using immunohistochemistry, tu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3452-y

    authors: Kim JY,Lee SH,Kim S,Kang T,Bae YT

    更新日期:2015-04-01 00:00:00

  • A patient with swelling of the eyelid: ancient schwannoma of the supraorbital nerve (2010:6b).

    abstract::We present a case of swelling of the eyelid and supraorbital anesthesia caused by an intraorbital tumor. The differential diagnosis based on imaging consisted of aneurysmal bone cyst, schwannoma, neurofibroma, dermoid cyst, and cavernous hemangioma. The surgical and pathological diagnosis was an ancient schwannoma of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1659-0

    authors: de Jong L,Demaerel P,Sciot R,Van Calenbergh F

    更新日期:2010-09-01 00:00:00

  • High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo.

    abstract:OBJECTIVES:The objective of this study was to compare the diagnostic performance of direct C-arm flat panel computed tomography arthrography (FPCT-A) with direct magnetic resonance arthrography (MR-A) of the wrist in patients with clinically suspected pathologies. METHODS:Forty-nine patients underwent tri-compartmenta...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5901-5

    authors: Sonnow L,Koennecker S,Luketina R,Werncke T,Hinrichs JB,Meyer BC,Wacker FK,von Falck C

    更新日期:2019-06-01 00:00:00

  • PET/CT in primary musculoskeletal tumours: a step forward.

    abstract::Hybrid imaging with combined positron emission tomography/computed tomography (PET/CT) plays an important role in the staging and management of a wide variety of solid tumours. However, its use in the evaluation of musculoskeletal malignancy has not yet entered routine clinical practice. Cross-sectional imaging with m...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-010-1862-z

    authors: Lakkaraju A,Patel CN,Bradley KM,Scarsbrook AF

    更新日期:2010-12-01 00:00:00

  • CT attenuation of paired HRCT scans obtained at full inspiratory/expiratory position: comparison with pulmonary function tests.

    abstract::The purpose of this prospective study was to measure lung attenuation at paired HRCT obtained at full inspiratory/expiratory position, to correlate with pulmonary function tests (PFTs) and to characterize different types of ventilatory impairment. One hundred fifty-five patients with and without pulmonary disease unde...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1514-z

    authors: Kauczor HU,Hast J,Heussel CP,Schlegel J,Mildenberger P,Thelen M

    更新日期:2002-11-01 00:00:00

  • A hand-held ultrasound machine vs. conventional ultrasound machine in the bedside assessment of post-liver transplant patients.

    abstract::The purpose was to assess the diagnostic accuracy of a hand-held Doppler ultrasound (US) machine for the bedside detection of liver and vascular abnormalities after liver transplantation in the intensive care unit. The IRB approved this study, and written informed consent was obtained from all patients or the patient'...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-009-1417-3

    authors: Trinquart L,Bruno O,Angeli ML,Belghiti J,Chatellier G,Vilgrain V

    更新日期:2009-10-01 00:00:00

  • Cystic form of paraduodenal pancreatitis (cystic dystrophy in heterotopic pancreas (CDHP)): a potential link with minor papilla abnormalities? A study in a large series.

    abstract:OBJECTIVES:To analyze the association between cystic dystrophy in the heterotopic pancreas (CDHP) and minor papilla abnormalities. MATERIAL AND METHODS:Seventy-six patients with CDHP were retrospectively included over 14 years. Two radiologists searched for MDCT signs of CDHP (cysts and thickened intestinal wall, infl...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3799-8

    authors: Wagner M,Vullierme MP,Rebours V,Ronot M,Ruszniewski P,Vilgrain V

    更新日期:2016-01-01 00:00:00

  • Assessment of relevant hepatic steatosis in obese adolescents by rapid fat-selective GRE imaging with spatial-spectral excitation: a quantitative comparison with spectroscopic findings.

    abstract:OBJECTIVE:To test the feasibility of fat-selective GRE imaging using a spectral-spatial excitation technique for determination of intrahepatic lipid content (IHL) in obese adolescents. METHODS:Fat-selective MR imaging (1.5 T) was applied to record a single axial slice through a representative liver region within a sin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1975-4

    authors: Springer F,Ehehalt S,Sommer J,Ballweg V,Machann J,Binder G,Claussen CD,Schick F,DISKUS-Study Group.

    更新日期:2011-04-01 00:00:00

  • Aneurysmal bone cyst of the cervical spine (2008:7b).

    abstract::Aneurysmal bone cysts (ABC) are rare, benign, but locally destructive bone tumors. They occur in the spine in 14% of cases, but only 2% are found in the cervical spine. This case report presents a 16-year-old female with an expansive aneurysmatic bone cyst with extensive bone destruction and instability in the cervica...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0944-7

    authors: Pennekamp W,Peters S,Schinkel C,Kuhnen C,Nicolas V,Muhr G,Frangen TM

    更新日期:2008-10-01 00:00:00

  • Low-dose triple-rule-out using 320-row-detector volume MDCT--less contrast medium and lower radiation exposure.

    abstract:OBJECTIVES:To investigate image quality of triple-rule-out (TRO) computed tomography (CT) using a 320-row-detector CT system with substantially reduced contrast medium volume at 100 kV. METHODS:Forty-six consecutive patients with noncritical, acute chest pain underwent 320-row-detector CT using a two-step TRO protocol...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2088-4

    authors: Durmus T,Rogalla P,Lembcke A,Mühler MR,Hamm B,Hein PA

    更新日期:2011-07-01 00:00:00

  • Early detection with MRI of incomplete treatment of spine metastases after percutaneous cryoablation.

    abstract:OBJECTIVES:To evaluate post-ablation MRI for the detection of incompletely treated spinal osseous metastases (SOM) after cryoablation and to propose a post-ablation imaging classification. METHODS:After IRB consent, all patients treated with cryoablation of SOM between 2011 and 2017 having at least 1-year minimum foll...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06040-y

    authors: Gravel G,Tselikas L,Moulin B,Yevich S,Baudin E,Hakime A,Moalla S,Mihoubi F,Balleyguier C,de Baere T,Deschamps F

    更新日期:2019-10-01 00:00:00

  • Impact of high resolution 3 tesla MR neurography (MRN) on diagnostic thinking and therapeutic patient management.

    abstract:OBJECTIVE:To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. METHODS:IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3958-y

    authors: Chhabra A,Belzberg AJ,Rosson GD,Thawait GK,Chalian M,Farahani SJ,Shores JT,Deune G,Hashemi S,Thawait SK,Subhawong TK,Carrino JA

    更新日期:2016-05-01 00:00:00

  • 11C-harmine as a potential PET tracer for ductal pancreas cancer: in vitro studies.

    abstract::Our objective was to find a tracer in diagnosing human pancreatic cancer using positron emission tomography (PET). For this purpose in vitro test of pancreatic tissues with autoradiography was used. Autoradiography was performed with (11)C-harmine (a MAO-A-inhibitor) with and without competitive inhibition. Tissue pre...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1443-x

    authors: Herlin G,Persson B,Bergström M,Långström B,Aspelin P

    更新日期:2003-04-01 00:00:00

  • The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis.

    abstract::The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1811-6

    authors: Breysem L,Bosmans H,Dymarkowski S,Schoubroeck DV,Witters I,Deprest J,Demaerel P,Vanbeckevoort D,Vanhole C,Casaer P,Smet M

    更新日期:2003-07-01 00:00:00

  • Neurilemoma of the renal capsule: MR imaging and pathologic correlation.

    abstract::We report a case of neurilemoma arising from the renal capsule. Renal neurilemoma is an especially rare tumor, with only 15 cases previously reported. We attempted to correlate MR findings with microscopic components of the tumor. On T2-weighted images the solid part of the tumor was heterogeneous hyperintense. The MR...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000767

    authors: Tsurusaki M,Mimura F,Yasui N,Minayoshi K,Sugimura K

    更新日期:2001-01-01 00:00:00