PET/CT in primary musculoskeletal tumours: a step forward.

Abstract:

:Hybrid imaging with combined positron emission tomography/computed tomography (PET/CT) plays an important role in the staging and management of a wide variety of solid tumours. However, its use in the evaluation of musculoskeletal malignancy has not yet entered routine clinical practice. Cross-sectional imaging with magnetic resonance imaging (MR) and computed tomography have well-established roles but there is increasing evidence for the selective use of PET/CT in the management of these patients. The aims of this article are to review the current evidence and clinical applications of PET/CT in primary musculoskeletal tumours and discuss potential future developments using novel PET tracers and integrated PET/MR.

journal_name

Eur Radiol

journal_title

European radiology

authors

Lakkaraju A,Patel CN,Bradley KM,Scarsbrook AF

doi

10.1007/s00330-010-1862-z

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

2959-72

issue

12

eissn

0938-7994

issn

1432-1084

journal_volume

20

pub_type

杂志文章,评审
  • Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

    abstract::The purpose of this study was to analyse the radiation exposure of medical staff from interventional x-ray procedures. Partial-body dose measurements were performed with thermoluminescent dosimeters (TLD) in 39 physicians and nine assistants conducting 73 interventional procedures of nine different types in 14 hospita...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-009-1388-4

    authors: Häusler U,Czarwinski R,Brix G

    更新日期:2009-08-01 00:00:00

  • Magnetic resonance imaging of pelvic floor dysfunction - joint recommendations of the ESUR and ESGAR Pelvic Floor Working Group.

    abstract:OBJECTIVE:To develop recommendations that can be used as guidance for standardized approach regarding indications, patient preparation, sequences acquisition, interpretation and reporting of magnetic resonance imaging (MRI) for diagnosis and grading of pelvic floor dysfunction (PFD). METHODS:The technique included cri...

    journal_title:European radiology

    pub_type: 共识发展会议,杂志文章

    doi:10.1007/s00330-016-4471-7

    authors: El Sayed RF,Alt CD,Maccioni F,Meissnitzer M,Masselli G,Manganaro L,Vinci V,Weishaupt D,ESUR and ESGAR Pelvic Floor Working Group.

    更新日期:2017-05-01 00:00:00

  • Prevalence and prognostic value of late gadolinium enhancement on CMR in aortic stenosis: meta-analysis.

    abstract:OBJECTIVES:The aim of this study was to investigate the prevalence and prognostic value of late gadolinium enhancement (LGE), as assessed by cardiovascular magnetic resonance (CMR) imaging, in patients with aortic stenosis. METHODS AND RESULTS:A systematic search of PubMed and EMBASE was performed, and observational c...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-019-06386-3

    authors: Balciunaite G,Skorniakov V,Rimkus A,Zaremba T,Palionis D,Valeviciene N,Aidietis A,Serpytis P,Rucinskas K,Sogaard P,Glaveckaite S

    更新日期:2020-01-01 00:00:00

  • Cardiac MRI in pulmonary artery hypertension: correlations between morphological and functional parameters and invasive measurements.

    abstract:OBJECTIVE:To compare cardiac MRI with right heart catheterisation in patients with pulmonary hypertension (PH) and to evaluate its ability to assess PH severity. MATERIALS AND METHODS:Forty patients were included. MRI included cine and phase-contrast sequences, study of ventricular function, cardiac cavity areas and r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1664-3

    authors: Alunni JP,Degano B,Arnaud C,Tétu L,Blot-Soulétie N,Didier A,Otal P,Rousseau H,Chabbert V

    更新日期:2010-05-01 00:00:00

  • Tumour volume of resectable oesophageal squamous cell carcinoma measured with MRI correlates well with T category and lymphatic metastasis.

    abstract:OBJECTIVES:To determine association of gross tumour volume (GTV) of resectable oesophageal squamous cell carcinoma (SCC) measured on T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE-T1WI) and diffusion-weighted imaging (DWI) with T category and lymphatic metastasis (LM). METHODS:Sixty oesophageal ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5477-0

    authors: Wu L,Ou J,Chen TW,Li R,Zhang XM,Chen YL,Jiang Y,Yang JQ,Cao JM

    更新日期:2018-11-01 00:00:00

  • Normative brain volume reports may improve differential diagnosis of dementing neurodegenerative diseases in clinical practice.

    abstract:OBJECTIVES:Normative brain volume reports (NBVRs) are becoming more and more available for the workup of dementia patients in clinical routine. However, it is yet unknown how this information can be used in the radiological decision-making process. The present study investigates the diagnostic value of NBVRs for detect...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06602-0

    authors: Hedderich DM,Dieckmeyer M,Andrisan T,Ortner M,Grundl L,Schön S,Suppa P,Finck T,Kreiser K,Zimmer C,Yakushev I,Grimmer T

    更新日期:2020-05-01 00:00:00

  • Small peripheral lung carcinomas with five-year post-surgical follow-up: assessment by semi-automated volumetric measurement of tumour size, CT value and growth rate on TSCT.

    abstract:OBJECTIVES:To retrospectively assess the utility of semi-automated measurements by stratification of CT values of tumour size, CT value and doubling time (DT) using thin-section computed tomography (CT) images. The post-surgical outcomes of favourable and problematic tumours (more advanced p stage than IA, post-surgica...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2241-0

    authors: Sone S,Hanaoka T,Ogata H,Takayama F,Watanabe T,Haniuda M,Kaneko K,Kondo R,Yoshida K,Honda T

    更新日期:2012-01-01 00:00:00

  • Monitoring therapeutic responses of primary bone tumors by diffusion-weighted image: Initial results.

    abstract::The purpose of our study was to investigate whether quantitative diffusion-weighted images (DWI) were useful for monitoring the therapeutic response of primary bone tumors. We encountered 18 osteogenic and Ewing sarcomas. Magnetic resonance (MR) images were performed in all patients before and after therapy. We measur...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0342-y

    authors: Hayashida Y,Yakushiji T,Awai K,Katahira K,Nakayama Y,Shimomura O,Kitajima M,Hirai T,Yamashita Y,Mizuta H

    更新日期:2006-12-01 00:00:00

  • Congenital anorectal atresia: MR imaging of late post-operative appearances in adult patients with anal incontinence.

    abstract:OBJECTIVES:To describe the MR imaging findings in adults presenting with anal incontinence following pull-through perineoplasty for anorectal atresia. METHODS:15 adults (12 male, 3 female; age 22-52 years) with anal incontinence following a prior perineal pull-through procedure as an infant for anorectal atresia were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2949-0

    authors: Gartner L,Peiris C,Marshall M,Taylor SA,Halligan S

    更新日期:2013-12-01 00:00:00

  • Accuracy of single-energy quantitative computed tomography in the assessment of bone mineral density of cervical vertebrae.

    abstract::Earlier studies have shown that single-energy quantitative computed tomography (SEQCT) is a reliable method for bone mineral density (BMD) measurements in thoracic and lumbar vertebrae. Moreover, SEQCT has proved to be a useful parameter in the selection of appropriate implants in cervical spondylodesis. The aim of th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050312

    authors: Zink PM,Samii M,Luedemann W,Bellinzona M,Prokop M

    更新日期:1997-01-01 00:00:00

  • Amide proton transfer-weighted MRI can detect tissue acidosis and monitor recovery in a transient middle cerebral artery occlusion model compared with a permanent occlusion model in rats.

    abstract:OBJECTIVES:To assess whether increases in amide proton transfer (APT)-weighted signal reflect the effects of tissue recovery from acidosis using transient rat middle cerebral artery occlusion (MCAO) models, compared to permanent occlusion models. MATERIALS AND METHODS:Twenty-four rats with MCAO (17 transient and seven...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5964-3

    authors: Park JE,Jung SC,Kim HS,Suh JY,Baek JH,Woo CW,Park B,Woo DC

    更新日期:2019-08-01 00:00:00

  • Cross-sectional imaging of primary osseous hemangiopericytoma.

    abstract::The aim of this study was to assess cross-sectional imaging features and the value of CT and MRI in primary hemangiopericytoma of bone. In five patients with histologically proven primary osseous hemangiopericytoma CT and MR scans were evaluated retrospectively. Both CT and MRI were available in four patients each. In...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300101027

    authors: Mahnken AH,Tacke J,Wolter P,Büttner R,Haller JS,Günther RW

    更新日期:2002-01-01 00:00:00

  • Accelerated myelination associated with venous congestion.

    abstract::Magnetic resonance imaging is currently the gold standard in the assessment of brain myelination. The normal pattern of brain myelination conforms to a fixed chronological sequence. Focal accelerated myelination is a usual pathological state and previously has only been associated with Sturge-Weber syndrome. The purpo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0044-x

    authors: Porto L,Kieslich M,Yan B,Zanella FE,Lanfermann H

    更新日期:2006-04-01 00:00:00

  • Heterotropic mesenteric ossification: a case report (2004:10b).

    abstract::Heterotropic mesenteric ossification is a rare entity. Only a few cases have been described in the literature. We report a case of heterotropic mesenteric ossification in a patient who underwent several laparotomies, after suffering from multiple gunshot wounds. We discuss the radiographic findings of this disease tha...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2464-4

    authors: Tonino BA,van der Meulen HG,Kuijpers KC,Mallens WM,van Gils AP

    更新日期:2005-01-01 00:00:00

  • Long-term retention of gadolinium in the skin of rodents following the administration of gadolinium-based contrast agents.

    abstract::Several publications suggest a potential association between the administration of Gadolinium-based contrast agents (GBCAs) and the onset of a rare but serious disease, Nephrogenic Systemic Fibrosis (NSF). The aim of this study was to determine the elimination time-course of Gadolinium (Gd) from skin tissue after appl...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1259-4

    authors: Pietsch H,Lengsfeld P,Jost G,Frenzel T,Hütter J,Sieber MA

    更新日期:2009-06-01 00:00:00

  • Quantitative assessment of terminal ileum motility on MR enterography in Crohn disease: a feasibility study in children.

    abstract:OBJECTIVES:Investigate the relationship between quantified terminal ileal (TI) motility and histopathological activity grading, Crohn Disease MRI Index (CDMI) and faecal calprotectin. METHODS:Retrospective review of children with Crohn disease or unclassified inflammatory bowel disease, who underwent MR enterography. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07084-1

    authors: Cococcioni L,Fitzke H,Menys A,Gaunt T,Kumar S,Kiparissi F,Rampling D,Palm L,Taylor SA,Watson TA

    更新日期:2021-02-01 00:00:00

  • Influence of patient axial malpositioning on the trueness and precision of pelvic parameters obtained from 3D reconstructions based on biplanar radiographs.

    abstract:OBJECTIVES:Radiographs are often performed to assess pelvic and hip parameters, but results depend upon correct pelvis positioning. Three-dimensional (3D) reconstruction from biplanar-radiographs should provide parameters that are less sensitive to pelvic orientation, but this remained to be evaluated. METHODS:Compute...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4452-x

    authors: Ghostine B,Sauret C,Assi A,Bakouny Z,Khalil N,Skalli W,Ghanem I

    更新日期:2017-03-01 00:00:00

  • The clinical value of a negative multi-detector computed tomographic angiography in patients suspected of coronary artery disease: A meta-analysis.

    abstract::The aim of this meta-analysis was to calculate the sensitivity of contrast-enhanced multi-detector computed tomography (MDCT) compared with coronary angiography (CAG) in incident patients suspected of coronary artery disease (CAD). We searched PubMed, Embase, bibliographies of original papers and reviews to identify o...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-006-0312-4

    authors: van der Zaag-Loonen HJ,Dikkers R,de Bock GH,Oudkerk M

    更新日期:2006-12-01 00:00:00

  • Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results.

    abstract::The potential relative beneficial aspects of upright, weight-bearing (pMRI), dynamic-kinetic (kMRI) spinal imaging over that of recumbent MRI (rMRI) include the revelation of occult spinal disease dependent on true axial loading, the unmasking of kinetic-dependent spinal disease and the ability to scan the patient in ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2666-4

    authors: Jinkins JR,Dworkin JS,Damadian RV

    更新日期:2005-09-01 00:00:00

  • Value of abdominal CT in the emergency department for patients with abdominal pain.

    abstract::The purpose of our study is to demonstrate the value of CT in the emergency department (ED) for patients with non-traumatic abdominal pain. Between August 1998 and April 1999, 536 consecutive patients with non-traumatic abdominal pain were entered into our study. Using a computer order entry system, physicians were as...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1715-5

    authors: Rosen MP,Siewert B,Sands DZ,Bromberg R,Edlow J,Raptopoulos V

    更新日期:2003-02-01 00:00:00

  • Fine needle aspiration biopsy indications for thyroid nodules: compare a point-based risk stratification system with a pattern-based risk stratification system.

    abstract:OBJECTIVES:We aim to compare the diagnostic performance to assess thyroid nodules and reliability for recommending fine needle aspiration biopsy (FNAB) between American College of Radiology thyroid image reporting and data system (ACR TI-RADS) and American Thyroid Association (ATA) guidelines. METHODS:In total, this r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5992-z

    authors: Ruan JL,Yang HY,Liu RB,Liang M,Han P,Xu XL,Luo BM

    更新日期:2019-09-01 00:00:00

  • Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI). I. Experimental studies.

    abstract::The objectives of this study were to evaluate the influence on image quality and dose to the patient and operator of various equipment settings for percutaneous coronary intervention (PCI), and to optimize the set-up. With an Alderson phantom, different settings, such as projection, protective screens, filtration, ima...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1237-6

    authors: Geijer H,Beckman KW,Andersson T,Persliden J

    更新日期:2002-10-01 00:00:00

  • Radioembolisation with (90)Y-labelled resin microspheres in the treatment of liver metastasis from breast cancer.

    abstract:OBJECTIVES:Metastatic breast cancer is a heterogeneous disease, commonly affecting the liver. We report our experience with (90)Y radioembolisation (RE) and its effects on the survival of patients with treatment-refractory breast cancer liver metastases. METHODS:A total of 77 female patients affected by breast cancer ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2556-5

    authors: Cianni R,Pelle G,Notarianni E,Saltarelli A,Rabuffi P,Bagni O,Filippi L,Cortesi E

    更新日期:2013-01-01 00:00:00

  • Advances in ultrasound.

    abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-001-1185-1

    authors: Claudon M,Tranquart F,Evans DH,Lefèvre F,Correas M

    更新日期:2002-01-01 00:00:00

  • Imaging of trabecular bone structure in osteoporosis.

    abstract::Osteoporosis is a metabolic bone disorder that is characterized by reduced bone mass and a deterioration of bone structure which results in an increased fracture risk. Since the disease is preventable, diagnostic techniques are of major importance. Standard techniques determine bone mineral density, whereas some of th...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050922

    authors: Link TM,Majumdar S,Grampp S,Guglielmi G,van Kuijk C,Imhof H,Glueer C,Adams JE

    更新日期:1999-01-01 00:00:00

  • MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking.

    abstract::The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0377-0

    authors: Sequeiros RB,Reinikainen H,Sequeiros AM,Vaara T,Ojala R,Pääkkö E,Tervonen O

    更新日期:2007-03-01 00:00:00

  • Quantitative validation of a visual rating scale for frontal atrophy: associations with clinical status, APOE e4, CSF biomarkers and cognition.

    abstract:OBJECTIVES:To validate a visual rating scale of frontal atrophy with quantitative imaging and study its association with clinical status, APOE ε4, CSF biomarkers, and cognition. METHODS:The AddNeuroMed and ADNI cohorts were combined giving a total of 329 healthy controls, 421 mild cognitive impairment patients, and 28...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4101-9

    authors: Ferreira D,Cavallin L,Granberg T,Lindberg O,Aguilar C,Mecocci P,Vellas B,Tsolaki M,Kłoszewska I,Soininen H,Lovestone S,Simmons A,Wahlund LO,Westman E,AddNeuroMed consortium and for the Alzheimer’s Disease Neuroimaging Initiat

    更新日期:2016-08-01 00:00:00

  • MR angiography: supra-aortic vessels.

    abstract::Magnetic resonance angiography (MRA) has become an imaging modality which comprises various techniques based on two concepts: methods relying on the natural flow effects, the time-of-flight and phase-contrast technique, either in two- or three-dimensional acquisition mode, and the more recently developed contrast-enha...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050834

    authors: Wetzel S,Bongartz G

    更新日期:1999-01-01 00:00:00

  • Long-term prognostic performance of low-dose coronary computed tomography angiography with prospective electrocardiogram triggering.

    abstract:OBJECTIVES:To assess long-term prognosis after low-dose 64-slice coronary computed tomography angiography (CCTA) using prospective electrocardiogram-triggering. METHODS:We included 434 consecutive patients with suspected or known coronary artery disease referred for low-dose CCTA. Patients were classified as normal, w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4849-1

    authors: Clerc OF,Kaufmann BP,Possner M,Liga R,Vontobel J,Mikulicic F,Gräni C,Benz DC,Fuchs TA,Stehli J,Pazhenkottil AP,Gaemperli O,Kaufmann PA,Buechel RR

    更新日期:2017-11-01 00:00:00

  • Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring?

    abstract::Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed tab...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2288-2

    authors: Kiessling F,Boese J,Corvinus C,Ederle JR,Zuna I,Schoenberg SO,Brix G,Schmähl A,Tuengerthal S,Herth F,Kauczor HU,Essig M

    更新日期:2004-07-01 00:00:00