CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial.

Abstract:

:To assess both sensitivity and specificity of digital chest radiography alone and in conjunction with dual-exposure dual-energy chest radiography for the detection and classification of pulmonary nodules. One hundred patients with a total of 149 lung nodules (3-45 mm; median, 11 mm) confirmed by CT were included in this study. Dual-exposure dual-energy chest radiographies of each patient were obtained using a CsI detector system. Experienced board-certified chest radiologists from four different medical centers in Europe reviewed standard chest radiographs alone and in conjunction with dual-energy images blinded and in random order. The reviewers rated the probability of presence, calcification and malignancy of all lung nodules on a five-point rating scale. Lesions detected were identified by applying a specific coordinate system to enable precise verification by the study leader. A receiver-operating characteristic (ROC) analysis was performed. In addition to the 149 true-positive CT proven lesions, 236 false-positive lung nodules were described in digital chest radiographies in conjunction with dual-energy chest radiographies. The cumulative sensitivity of chest radiography in conjunction with dual energy was 43%, specificity was 55%. For digital radiography alone, sensitivity was 35% and specifity was 83%. For the dual energy system, positive predictive value was 58%, and negative predictive value was 66% compared to the digital radiography with a positive predictive value of 59% and a negative predictive value of 65%. Areas under the curve in a ROC analysis resulted in 0.631 (95% confidence interval =0.61 to 0.65) for radiography with dual energy and 0.602 (95% confidence interval =0.58 to 0.63) for digital radiography alone. This difference was not statistically significant. For the detection of lesion calcification or the determination of malignancy, ROC analysis also failed to show significant differences. CsI-based flat-panel dual-exposure dual-energy imaging added to standard chest radiography did not show statistically significant improvement for the detection of pulmonary nodules, nor the identification of calcifications, nor the determination of malignancy.

journal_name

Eur Radiol

journal_title

European radiology

authors

Rühl R,Wozniak MM,Werk M,Laurent F,Mager G,Montaudon M,Pattermann A,Scherrer A,Tasu JP,Pech M,Ricke J

doi

10.1007/s00330-008-0945-6

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

1831-9

issue

9

eissn

0938-7994

issn

1432-1084

journal_volume

18

pub_type

临床试验,杂志文章,多中心研究
  • Integrated imaging of non-small cell lung cancer recurrence: CT and PET-CT findings, possible pitfalls and risk of recurrence criteria.

    abstract:OBJECTIVES:To review the role of imaging in the diagnosis of recurrent disease in previously treated non-small cell lung cancer (NSCLC) and discuss the imaging pitfalls. METHODS:A comprehensive review of published literature on CT and PET imaging of NSCLC recurrence was performed. Diagnostic and prognostic values are ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-011-2299-8

    authors: Caulo A,Mirsadraee S,Maggi F,Leccisotti L,van Beek EJ,Bonomo L

    更新日期:2012-03-01 00:00:00

  • What are the predictors of clinical success after percutaneous vertebroplasty for osteoporotic vertebral fractures?

    abstract:OBJECTIVES:Osteoporotic vertebral fractures are responsible for acute pain and disability that may persist for more than 2 months. We wanted to identify predicting factors for mid-term outcome after vertebroplasty. METHODS:We included consecutive patients who underwent vertebroplasty for fragility fractures with persi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5274-1

    authors: Denoix E,Viry F,Ostertag A,Parlier-Cuau C,Laredo JD,Cohen-Solal M,Bousson V,Funck-Brentano T

    更新日期:2018-07-01 00:00:00

  • Workflow-centred evaluation of an automatic lesion tracking software for chemotherapy monitoring by CT.

    abstract:OBJECTIVES:In chemotherapy monitoring, an estimation of the change in tumour size is an important criterion for the assessment of treatment success. This requires a comparison between corresponding lesions in the baseline and follow-up computed tomography (CT) examinations. We evaluate the clinical benefits of an autom...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2545-8

    authors: Moltz JH,D'Anastasi M,Kiessling A,Pinto dos Santos D,Schülke C,Peitgen HO

    更新日期:2012-12-01 00:00:00

  • Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging.

    abstract::Our objective was to study Gd-EOB-DTPA for the characterization of focal liver lesions by means of dynamic MR imaging. A double-blind and randomized dose-ranging phase-2 clinical trial was performed in 31 patients (liver metastases n = 23, hepatocellular carcinoma n = 4, and hemangioma n = 4) at a field strength of 1....

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s003300050150

    authors: Reimer P,Rummeny EJ,Daldrup HE,Hesse T,Balzer T,Tombach B,Peters PE

    更新日期:1997-01-01 00:00:00

  • Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.

    abstract:OBJECTIVES:To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS:Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3952-4

    authors: Varga-Szemes A,Muscogiuri G,Schoepf UJ,Wichmann JL,Suranyi P,De Cecco CN,Cannaò PM,Renker M,Mangold S,Fox MA,Ruzsics B

    更新日期:2016-05-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00

  • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

    abstract::The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, ple...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0562-1

    authors: Das M,Ley-Zaporozhan J,Gietema HA,Czech A,Mühlenbruch G,Mahnken AH,Katoh M,Bakai A,Salganicoff M,Diederich S,Prokop M,Kauczor HU,Günther RW,Wildberger JE

    更新日期:2007-08-01 00:00:00

  • Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma.

    abstract:OBJECTIVE:To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 (90Y)-radioembolization for hepatocellular carcinoma (HCC). METHODS:Studies comparing conventional (c)TACE versus 90Y-radioembolization or DEB-TACE for HCC treatment were identified usin...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-016-4548-3

    authors: Ludwig JM,Zhang D,Xing M,Kim HS

    更新日期:2017-05-01 00:00:00

  • Is imaging the future of axillary staging in breast cancer?

    abstract::Axillary management in patients with breast cancer has become much less invasive with the introduction of sentinel lymph node biopsy (SLNB). However, over 70 % of SLNBs are negative, questioning the generic use of this invasive procedure. Emerging evidence indicates that breast cancer patients with a low axillary burd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-013-3009-5

    authors: Ahmed M,Usiskin SI,Hall-Craggs MA,Douek M

    更新日期:2014-02-01 00:00:00

  • Migrating transient bone marrow edema syndrome of the knee: MRI findings in a new case.

    abstract::We report a case of transient bone marrow edema syndrome migrating within two different compartments of the same knee. This unusual pattern of migration of the marrow edema, which has been previously described only in three cases of transient osteoporosis, may raise the suspicion of an aggressive disease. Radiologists...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1584-y

    authors: Gaeta M,Mazziotti S,Minutoli F,Vinci S,Blandino A

    更新日期:2002-12-01 00:00:00

  • Vertebral morphometry: current methods and recent advances.

    abstract::Vertebral fractures are the hallmark of osteoporosis and are associated with increased morbility and mortality. Because a majority of vertebral fractures often occur in absence of specific trauma and are asymptomatic, their identification is radiographic. The two most widely used methods to determine the severity of v...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-008-0899-8

    authors: Guglielmi G,Diacinti D,van Kuijk C,Aparisi F,Krestan C,Adams JE,Link TM

    更新日期:2008-07-01 00:00:00

  • Quantitative validation of a visual rating scale for frontal atrophy: associations with clinical status, APOE e4, CSF biomarkers and cognition.

    abstract:OBJECTIVES:To validate a visual rating scale of frontal atrophy with quantitative imaging and study its association with clinical status, APOE ε4, CSF biomarkers, and cognition. METHODS:The AddNeuroMed and ADNI cohorts were combined giving a total of 329 healthy controls, 421 mild cognitive impairment patients, and 28...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4101-9

    authors: Ferreira D,Cavallin L,Granberg T,Lindberg O,Aguilar C,Mecocci P,Vellas B,Tsolaki M,Kłoszewska I,Soininen H,Lovestone S,Simmons A,Wahlund LO,Westman E,AddNeuroMed consortium and for the Alzheimer’s Disease Neuroimaging Initiat

    更新日期:2016-08-01 00:00:00

  • Lumbar spine radiology: analysis of the posteroanterior projection.

    abstract::The use of the posteroanterior (PA) technique as a means of dose reduction has been used effectively in radiology departments for chest and abdominal examinations. The aim of this investigation was to establish if the PA lumbar spine projection offers any advantages over the traditional anteroposterior (AP) view in te...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003309900272

    authors: Brennan PC,Madigan E

    更新日期:2000-01-01 00:00:00

  • Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients.

    abstract::To assess the immediate efficacy of percutaneous vertebroplasty (PVP) in relief of pain and improving mobility of patients with vertebral compression fractures (VCF) secondary to osteoporosis, 205 cases (175 patients) underwent 250 percutaneous injections of polymethylmethacrylate (PMMA; unilateral, 247 levels; bilate...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2549-0

    authors: Kobayashi K,Shimoyama K,Nakamura K,Murata K

    更新日期:2005-02-01 00:00:00

  • Radioembolisation with (90)Y-labelled resin microspheres in the treatment of liver metastasis from breast cancer.

    abstract:OBJECTIVES:Metastatic breast cancer is a heterogeneous disease, commonly affecting the liver. We report our experience with (90)Y radioembolisation (RE) and its effects on the survival of patients with treatment-refractory breast cancer liver metastases. METHODS:A total of 77 female patients affected by breast cancer ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2556-5

    authors: Cianni R,Pelle G,Notarianni E,Saltarelli A,Rabuffi P,Bagni O,Filippi L,Cortesi E

    更新日期:2013-01-01 00:00:00

  • Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content.

    abstract:OBJECTIVES:To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. METHODS:Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respirat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3353-0

    authors: Metens T,Ferraresi KF,Farchione A,Moreno C,Bali MA,Matos C

    更新日期:2014-12-01 00:00:00

  • Congenital midline cleft of the posterior arch of atlas: a rare cause of symptomatic cervical canal stenosis.

    abstract::Developmental symptomatic C1 canal stenosis is very rare. We describe the computed tomography (CT) and magnetic resonance imaging (MRI) appearances in a 8-year-old child who presented with progressive upper and lower limb neurological symptoms and in whom imaging revealed the medial posterior hemiarches of a bifid C1 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000755

    authors: Connor SE,Chandler C,Robinson S,Jarosz JM

    更新日期:2001-01-01 00:00:00

  • Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

    abstract:OBJECTIVES:To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). METHODS:Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-D...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5338-x

    authors: Euler A,Obmann MM,Szucs-Farkas Z,Mileto A,Zaehringer C,Falkowski AL,Winkel DJ,Marin D,Stieltjes B,Krauss B,Schindera ST

    更新日期:2018-08-01 00:00:00

  • Radiomic features from the peritumoral brain parenchyma on treatment-naïve multi-parametric MR imaging predict long versus short-term survival in glioblastoma multiforme: Preliminary findings.

    abstract:OBJECTIVE:Despite 90 % of glioblastoma (GBM) recurrences occurring in the peritumoral brain zone (PBZ), its contribution in patient survival is poorly understood. The current study leverages computerized texture (i.e. radiomic) analysis to evaluate the efficacy of PBZ features from pre-operative MRI in predicting long-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4637-3

    authors: Prasanna P,Patel J,Partovi S,Madabhushi A,Tiwari P

    更新日期:2017-10-01 00:00:00

  • Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT.

    abstract::To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetect...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-008-0958-1

    authors: Berther R,Patak MA,Eckhardt B,Erturk SM,Zollikofer CL

    更新日期:2008-09-01 00:00:00

  • Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.

    abstract:OBJECTIVES:The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. METHODS:An 80 kVp TB protocol for CTCA and CTPA was retros...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3281-z

    authors: Rodrigues JC,Joshi D,Lyen SM,Negus IS,Manghat NE,Hamilton MC

    更新日期:2014-10-01 00:00:00

  • Pancreatic adenocarcinoma.

    abstract::Adenocarcinoma is the most common malignant pancreatic tumor, affecting the head of the pancreas in 60-70% of cases. By the time of diagnosis, at least 80% of tumors are unresectable. Helical computed tomography (CT) is very effective in detecting and staging adenocarcinoma, with a sensitivity of up to 90% for detecti...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0435-7

    authors: Schima W,Ba-Ssalamah A,Kölblinger C,Kulinna-Cosentini C,Puespoek A,Götzinger P

    更新日期:2007-03-01 00:00:00

  • Grading of carotid artery stenosis with multidetector-row CT angiography: visual estimation or caliper measurements?

    abstract::To assess the optimal method for grading carotid artery stenosis with computed tomographic angiography (CTA), we compared visual estimation to caliper measurements, and determined inter-observer variability and agreement relative to digital subtraction angiography (DSA). We included 46 patients with symptomatic caroti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1508-1

    authors: Waaijer A,Weber M,van Leeuwen MS,Kardux J,Veldhuis WB,Lo R,Beek FJ,Prokop M

    更新日期:2009-12-01 00:00:00

  • Accessory ossicles and sesamoid bones of the ankle and foot: imaging findings, clinical significance and differential diagnosis.

    abstract::Accessory ossicles and sesamoid bones are frequent findings in routine radiographs of the ankle and foot. They are commonly considered fortuitous and unrelated to the patient's complaint; however, they may eventually cause painful syndromes or degenerative changes in response to overuse and trauma. They may also suffe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2011-8

    authors: Mellado JM,Ramos A,Salvadó E,Camins A,Danús M,Saurí A

    更新日期:2003-12-01 00:00:00

  • Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study.

    abstract:AIMS AND OBJECTIVES:Deep venous thrombosis (DVT) can be difficult to detect using CT due to poor and heterogeneous contrast. Dual-energy CT (DECT) allows iodine contrast optimization using noise-optimized monoenergetic extrapolations (MEIs) and iodine maps (IMs). Our aim was to assess whether MEI and IM could improve t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3544-8

    authors: Bongers MN,Schabel C,Krauss B,Tsiflikas I,Ketelsen D,Mangold S,Claussen CD,Nikolaou K,Thomas C

    更新日期:2015-06-01 00:00:00

  • Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method.

    abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100978

    authors: Parodi RC,Sardanelli F,Renzetti P,Rosso E,Losacco C,Ferrari A,Levrero F,Pilot A,Inglese M,Mancardi GL

    更新日期:2002-04-01 00:00:00

  • Automatic classification of ultrasound breast lesions using a deep convolutional neural network mimicking human decision-making.

    abstract:OBJECTIVES:To evaluate a deep convolutional neural network (dCNN) for detection, highlighting, and classification of ultrasound (US) breast lesions mimicking human decision-making according to the Breast Imaging Reporting and Data System (BI-RADS). METHODS AND MATERIALS:One thousand nineteen breast ultrasound images f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06118-7

    authors: Ciritsis A,Rossi C,Eberhard M,Marcon M,Becker AS,Boss A

    更新日期:2019-10-01 00:00:00

  • Epidemiology of systematic reviews in imaging journals: evaluation of publication trends and sustainability?

    abstract:PURPOSE:To evaluate the epidemiology of systematic reviews (SRs) published in imaging journals. METHODS:A MEDLINE search identified SRs published in imaging journals from 1 January 2000-31 December 2016. Articles retrieved were screened against inclusion criteria. Demographic and methodological characteristics were ex...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5567-z

    authors: Alabousi M,Alabousi A,McGrath TA,Cobey KD,Budhram B,Frank RA,Nguyen F,Salameh JP,Dehmoobad Sharifabadi A,McInnes MDF

    更新日期:2019-02-01 00:00:00

  • Quantitative assessment of tumour associated neovascularisation in patients with liver cirrhosis and hepatocellular carcinoma: role of dynamic-CT perfusion imaging.

    abstract:OBJECTIVE:To determine the value of perfusion computed tomography (CT-p) in the quantitative assessment of tumour-related neoangiogenesis processes in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Fifty-two biopsy proven HCC lesions were examined with dynamic CT investigations during injection of...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2307-z

    authors: Ippolito D,Capraro C,Casiraghi A,Cestari C,Sironi S

    更新日期:2012-04-01 00:00:00

  • An open source toolkit for medical imaging de-identification.

    abstract:OBJECTIVE:Medical imaging acquired for clinical purposes can have several legitimate secondary uses in research projects and teaching libraries. No commonly accepted solution for anonymising these images exists because the amount of personal data that should be preserved varies case by case. Our objective is to provide...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1745-3

    authors: González DR,Carpenter T,van Hemert JI,Wardlaw J

    更新日期:2010-08-01 00:00:00