Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.

Abstract:

OBJECTIVES:The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. METHODS:An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. RESULTS:Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. CONCLUSIONS:Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. KEY POINTS:• CT coronary angiography is performed to exclude the presence of significant coronary atherosclerosis. • CT pulmonary angiography is performed to diagnose pulmonary thromboembolism. • This retrospective study showed dose reduction by performing test bolus at 80 kVp. • Diagnosis can be made with reduced exposure to ionising radiation.

journal_name

Eur Radiol

journal_title

European radiology

authors

Rodrigues JC,Joshi D,Lyen SM,Negus IS,Manghat NE,Hamilton MC

doi

10.1007/s00330-014-3281-z

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

2458-66

issue

10

eissn

0938-7994

issn

1432-1084

journal_volume

24

pub_type

杂志文章
  • The correlation of mammographic-and histologic patterns of breast cancers in BRCA1 gene mutation carriers, compared to age-matched sporadic controls.

    abstract::Breast cancers in BRCA1 gene mutation carriers often have specific histologic features: grade III tumors with pushing margins. Our purpose was to compare the mammographic and histologic features of breast cancers in carriers with those in age-matched sporadic controls. The features of breast cancers in 27 BRCA1 carrie...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0385-0

    authors: Kaas R,Kroger R,Peterse JL,Hart AA,Muller SH

    更新日期:2006-12-01 00:00:00

  • Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings.

    abstract:OBJECTIVE:This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2944-5

    authors: Choi BH,Ko SM,Hwang HK,Song MG,Shin JK,Kang WS,Kim TY

    更新日期:2013-11-01 00:00:00

  • Evaluation of an organ-based tube current modulation tool in pediatric CT examinations.

    abstract:OBJECTIVES:To investigate the effect of an organ-based tube current modulation (OTCM) technique on organ absorbed dose and assess image quality in pediatric CT examinations. METHODS:Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old were use...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06888-5

    authors: Papadakis AE,Damilakis J

    更新日期:2020-10-01 00:00:00

  • The delayed effects of irreversible electroporation ablation on nerves.

    abstract:OBJECTIVE:To evaluate the delayed effects of irreversible electroporation (IRE) ablation on nerves. METHODS:The study was approved by the institutional animal care and use committee. CT-guided IRE-ablation (electric field per distance, 1,500 V/cm; pulse length, 70 μs; number of pulses, 90) of 6 sciatic nerves was perf...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2610-3

    authors: Schoellnast H,Monette S,Ezell PC,Maybody M,Erinjeri JP,Stubblefield MD,Single G,Solomon SB

    更新日期:2013-02-01 00:00:00

  • Changes in appearance of cortical formation abnormalities in the foetus detected on sequential in utero MR imaging.

    abstract:OBJECTIVES:We describe 64 foetuses with cortical formation abnormalities (CFA) who had two in utero magnetic resonance (iuMR) exams, paying particular detail to those in which the original classification of CFA category changed between the two studies. The goal was to attempt to quantify the value of third-trimester fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07125-9

    authors: Griffiths PD,Severino M,Jarvis D,Mandefield L,Parazzini C,Pinelli L,Di Maurizio M,Triulzi F,Scola E,Conte G,Palumbo G,Genovese M,Rossi A,Guerrini R,Righini A

    更新日期:2020-09-04 00:00:00

  • Radiological research in Europe: a bibliometric study.

    abstract::We performed a bibliometric search to evaluate number and scientific "weight" of papers written by European radiologists, as compared with colleagues from other countries, to measure the contribution of European researchers to radiology journals, and to correlate bibliometric parameters with some socio-economic factor...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1640-7

    authors: Mela GS,Martinoli C,Poggi E,Derchi LE

    更新日期:2003-04-01 00:00:00

  • Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

    abstract:PURPOSE:To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). MATERIALS AND METHODS:CESM cases of dense breasts with histological proof were evaluated in the present study. Fou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3271-1

    authors: Cheung YC,Lin YC,Wan YL,Yeow KM,Huang PC,Lo YF,Tsai HP,Ueng SH,Chang CJ

    更新日期:2014-10-01 00:00:00

  • Intra-abdominal desmoplastic small round-cell tumor: a rare cause of peritoneal malignancy in young people.

    abstract::We report the CT and pathological findings of an intra-abdominal desmoplastic small round-cell tumor in a young man. Computed tomography showed an extensive peritoneal and mesenteric disease with gross bulky masses, direct liver invasion, and lymph node involvement. This entity should be considered in the differential...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300051011

    authors: Sabaté JM,Torrubia S,Roson N,Matias-Guiu X,Gómez A

    更新日期:2000-01-01 00:00:00

  • Gadoxetic acid disodium-enhanced MR imaging of cholangiolocellular carcinoma of the liver: imaging characteristics and histopathological correlations.

    abstract:OBJECTIVES:To review the gadoxetic acid disodium (EOB)-enhanced magnetic resonance (MR) imaging features of cholangiolocellular carcinoma (CoCC) of the liver and compare them with those of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). METHODS:EOB-enhanced MR images of 19 patients with CoCC,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4811-2

    authors: Haradome H,Unno T,Morisaka H,Toda Y,Kwee TC,Kondo H,Sano K,Ichikawa T,Kondo F,Sugitani M,Takayama T

    更新日期:2017-11-01 00:00:00

  • Does coronary calcium scoring with a SCORE better predict significant coronary artery stenosis than without? Correlation with computed tomography coronary angiography.

    abstract:OBJECTIVE:To determine effectiveness of coronary artery calcium score (CACS) alone and combined with Systematic Coronary Risk Evaluation (SCORE) in adult patients for significant coronary artery stenosis by using computed tomography coronary angiography (CTCA) as reference standard. METHODS:Two thousand twenty-one pat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3477-2

    authors: Durhan G,Hazırolan T,Sunman H,Karakaya J,Karçaaltıncaba M,Aytemir K,Karaağaoğlu E,Akata D

    更新日期:2015-03-01 00:00:00

  • Diffusion-weighted MR imaging including bi-exponential fitting for the detection of recurrent or residual tumour after (chemo)radiotherapy for laryngeal and hypopharyngeal cancers.

    abstract:OBJECTIVES:To assess whether diffusion-weighted magnetic resonance imaging (DW-MRI) including bi-exponential fitting helps to detect residual/recurrent tumours after (chemo)radiotherapy of laryngeal and hypopharyngeal carcinoma. METHODS:Forty-six patients with newly-developed/worsening symptoms after (chemo)radiothera...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2596-x

    authors: Tshering Vogel DW,Zbaeren P,Geretschlaeger A,Vermathen P,De Keyzer F,Thoeny HC

    更新日期:2013-02-01 00:00:00

  • European Society of Gastrointestinal and Abdominal Radiology (ESGAR): consensus statement on CT colonography.

    abstract::Rapid clinical dissemination of CT colonography (CTC) is occurring in parallel with continued research into technique optimisation and diagnostic performance. A need exists therefore for current guidance as to basic prerequisites for effective clinical implementation. A questionnaire detailing CTC technique, analysis,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0407-y

    authors: Taylor SA,Laghi A,Lefere P,Halligan S,Stoker J

    更新日期:2007-02-01 00:00:00

  • Comparison of volumetric and functional parameters in simultaneous cardiac PET/MR: feasibility of volumetric assessment with residual activity from prior PET/CT.

    abstract:OBJECTIVE:To compare cardiac left ventricular (LV) parameters in simultaneously acquired hybrid fluorine-18-fluorodeoxyglucose ([18F] FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with residual tracer activity of upstream PET/CT. METHODS:Twenty-nine patients (23 men, age 58±17 year...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4896-7

    authors: Lücke C,Oppolzer B,Werner P,Foldyna B,Lurz P,Jochimsen T,Brenneis B,Lehmkuhl L,Sattler B,Grothoff M,Barthel H,Sabri O,Gutberlet M

    更新日期:2017-12-01 00:00:00

  • Acute obstruction of the renal collecting system: the intrarenal resistive index is a useful yet time-dependent parameter for diagnosis.

    abstract::The aim of this study was to determine whether the intrarenal resistive index (RI) can be used for the diagnosis of acute obstruction in patients with renal colic and to determine whether the index is time-related. Seventy patients referred to the Emergency Department with acute renal colic and without known associate...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050568

    authors: Opdenakker L,Oyen R,Vervloessem I,Goethuys H,Baert AL,Baert LV,Marchal G

    更新日期:1998-01-01 00:00:00

  • ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

    abstract::To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1181-9

    authors: Saur SC,Alkadhi H,Desbiolles L,Székely G,Cattin PC

    更新日期:2009-03-01 00:00:00

  • Early detection with MRI of incomplete treatment of spine metastases after percutaneous cryoablation.

    abstract:OBJECTIVES:To evaluate post-ablation MRI for the detection of incompletely treated spinal osseous metastases (SOM) after cryoablation and to propose a post-ablation imaging classification. METHODS:After IRB consent, all patients treated with cryoablation of SOM between 2011 and 2017 having at least 1-year minimum foll...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06040-y

    authors: Gravel G,Tselikas L,Moulin B,Yevich S,Baudin E,Hakime A,Moalla S,Mihoubi F,Balleyguier C,de Baere T,Deschamps F

    更新日期:2019-10-01 00:00:00

  • MR imaging in sports-related glenohumeral instability.

    abstract::Sports-related shoulder pain and injuries represent a common problem. In this context, glenohumeral instability is currently believed to play a central role either as a recognized or as an unrecognized condition. Shoulder instabilities can roughly be divided into traumatic, atraumatic, and microtraumatic glenohumeral ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0258-6

    authors: Woertler K,Waldt S

    更新日期:2006-12-01 00:00:00

  • Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

    abstract:OBJECTIVE:Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of l...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1966-5

    authors: Fabel M,Bolte H,von Tengg-Kobligk H,Bornemann L,Dicken V,Delorme S,Kauczor HU,Heller M,Biederer J

    更新日期:2011-04-01 00:00:00

  • Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications.

    abstract::Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2236-1

    authors: Reimer P,Schneider G,Schima W

    更新日期:2004-04-01 00:00:00

  • A patient with swelling of the eyelid: ancient schwannoma of the supraorbital nerve (2010:6b).

    abstract::We present a case of swelling of the eyelid and supraorbital anesthesia caused by an intraorbital tumor. The differential diagnosis based on imaging consisted of aneurysmal bone cyst, schwannoma, neurofibroma, dermoid cyst, and cavernous hemangioma. The surgical and pathological diagnosis was an ancient schwannoma of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1659-0

    authors: de Jong L,Demaerel P,Sciot R,Van Calenbergh F

    更新日期:2010-09-01 00:00:00

  • Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.

    abstract:OBJECTIVES:To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS:Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3952-4

    authors: Varga-Szemes A,Muscogiuri G,Schoepf UJ,Wichmann JL,Suranyi P,De Cecco CN,Cannaò PM,Renker M,Mangold S,Fox MA,Ruzsics B

    更新日期:2016-05-01 00:00:00

  • Peritoneal and pleural fluids may appear hyperintense on hepatobiliary phase using hepatobiliary MR contrast agents.

    abstract:AIM:To describe the effect of hepatobiliary-specific MR imaging contrast agent (HBCA) administration on the signal intensity of peritoneal and pleural fluid effusions on T1-weighted MR images. MATERIALS AND METHODS:From October 2015 to May 2016 139 patients (mean 60±10 years old, 69 % males) with peritoneal or pleural...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5261-6

    authors: Ciolina M,Di Martino M,Bruno O,Pommier R,Vilgrain V,Ronot M

    更新日期:2018-07-01 00:00:00

  • A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures.

    abstract:OBJECTIVES:To develop an anthropomorphic phantom closely mimicking patient anatomy and to evaluate the phantom for the simulation of computed tomography (CT)-guided procedures. METHODS:Patient CT images were printed with aqueous potassium iodide solution (1 g/mL) on paper. The printed paper sheets were stacked in alte...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5481-4

    authors: Jahnke P,Schwarz FB,Ziegert M,Almasi T,Abdelhadi O,Nunninger M,Hamm B,Scheel M

    更新日期:2018-11-01 00:00:00

  • Comparison of high-resolution computed tomography findings between Pseudomonas aeruginosa pneumonia and Cytomegalovirus pneumonia.

    abstract:OBJECTIVE:To compare pulmonary high-resolution CT (HRCT) findings in patients with Pseudomonas aeruginosa pneumonia to HRCT findings in patients with Cytomegalovirus (CMV) pneumonia. METHODS:We studied 124 patients (77 men, 47 women; age range, 20-89 years; mean age, 65.4 years) with P. aeruginosa pneumonia and 44 pat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3326-3

    authors: Omeri AK,Okada F,Takata S,Ono A,Nakayama T,Ando Y,Sato H,Hiramatsu K,Mori H

    更新日期:2014-12-01 00:00:00

  • Correction to: T1 and T2 MR fingerprinting measurements of prostate cancer and prostatitis correlate with deep learning-derived estimates of epithelium, lumen, and stromal composition on corresponding whole mount histopathology.

    abstract::The original version of this article, published on 02 September 2020, unfortunately contained a mistake. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-020-07285-8

    authors: Shiradkar R,Panda A,Leo P,Janowczyk A,Farre X,Janaki N,Li L,Pahwa S,Mahran A,Buzzy C,Fu P,Elliott R,MacLennan G,Ponsky L,Gulani V,Madabhushi A

    更新日期:2020-09-18 00:00:00

  • The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis.

    abstract::The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1811-6

    authors: Breysem L,Bosmans H,Dymarkowski S,Schoubroeck DV,Witters I,Deprest J,Demaerel P,Vanbeckevoort D,Vanhole C,Casaer P,Smet M

    更新日期:2003-07-01 00:00:00

  • Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging.

    abstract:OBJECTIVES:To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS:Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. F...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2487-1

    authors: Winter L,Kellman P,Renz W,Gräßl A,Hezel F,Thalhammer C,von Knobelsdorff-Brenkenhoff F,Tkachenko V,Schulz-Menger J,Niendorf T

    更新日期:2012-10-01 00:00:00

  • Abbreviated MRI for HCC surveillance: is it ready for clinical use?

    abstract:KEY POINTS:• Abbreviated MRI (AMRI) protocols consist of acquiring only a minimal number of MRI sequences for HCC surveillance with acceptable diagnostic performance compared to complete MRI.• AMRI protocol options include non-contrast AMRI, dynamic AMRI or hepatobiliary phase AMRI post gadoxetate injection.• The best ...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-020-06904-8

    authors: Vietti Violi N,Taouli B

    更新日期:2020-08-01 00:00:00

  • Whole-tumour diffusion kurtosis MR imaging histogram analysis of rectal adenocarcinoma: Correlation with clinical pathologic prognostic factors.

    abstract:OBJECTIVE:To investigate potential relationships between diffusion kurtosis imaging (DKI)-derived parameters using whole-tumour volume histogram analysis and clinicopathological prognostic factors in patients with rectal adenocarcinoma. MATERIAL AND METHODS:79 consecutive patients who underwent MRI examination with re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5094-3

    authors: Cui Y,Yang X,Du X,Zhuo Z,Xin L,Cheng X

    更新日期:2018-04-01 00:00:00

  • Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria.

    abstract:OBJECTIVE:To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. METHODS:A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excreto...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4206-9

    authors: Park JJ,Park BK,Kim CK

    更新日期:2016-10-01 00:00:00