Abstract:
:To study cell-field dynamics, physiologists simultaneously record local field potentials and the activity of individual cells from animals performing cognitive tasks, during various brain states or under pathological conditions. However, apart from spike shape and spike timing analyses, few studies have focused on elucidating the common time-frequency structure of local field activity relative to surrounding cells across different periods of phenomena. We have used two algorithms, multi-window time frequency analysis and wavelet phase coherence (WPC), to study common intracellular-extracellular (I-E) spectral features in spontaneous seizure-like events (SLEs) from rat hippocampal slices in a low magnesium epilepsy model. Both algorithms were applied to 'pairs' of simultaneously observed I-E signals from slices in the CA1 hippocampal region. Analyses were performed over a frequency range of 1-100 Hz. I-E spectral commonality varied in frequency and time. Higher commonality was observed from 1 to 15 Hz, and lower commonality was observed in the 15-100 Hz frequency range. WPC was lower in the non-SLE region compared to SLE activity; however, there was no statistical difference in the 30-45 Hz band between SLE and non-SLE modes. This work provides evidence of strong commonality in various frequency bands of I-E SLEs in the rat hippocampus, not only during SLEs but also immediately before and after.
journal_name
J Neural Engjournal_title
Journal of neural engineeringauthors
Cotic M,Chiu AW,Jahromi SS,Carlen PL,Bardakjian BLdoi
10.1088/1741-2560/8/4/046024subject
Has Abstractpub_date
2011-08-01 00:00:00pages
046024issue
4eissn
1741-2560issn
1741-2552pii
S1741-2560(11)87005-9journal_volume
8pub_type
杂志文章abstract:OBJECTIVE:The various parameters that define a hand movement such as its trajectory, speed, etc, are encoded in distinct brain activities. Decoding this information from neurophysiological recordings is a less explored area of brain-computer interface (BCI) research. Applying non-invasive recordings such as electroence...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/6/066019
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVE:Microwire and Utah-style neural recording arrays are the predominant devices used for cortical neural recording, but the implanted electrodes cause a significant adverse biological response and suffer from well-studied performance degradation. Recent work has demonstrated that carbon fiber electrodes do not e...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aae8d9
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:While motor-imagery based brain-computer interfaces (BCIs) have been studied over many years by now, most of these studies have taken place in controlled lab settings. Bringing BCI technology into everyday life is still one of the main challenges in this field of research. APPROACH:This paper systematically ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/5/056012
更新日期:2016-10-01 00:00:00
abstract::Implantable electrode arrays capable of recording and stimulating neural activity with high spatial and temporal resolution will provide a foundation for future brain computer interface technology. Currently, their clinical impact has been curtailed by a general lack of functional stability, which can be attributed to...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/5/4/003
更新日期:2008-12-01 00:00:00
abstract::The P300 speller is an example of a brain-computer interface that can restore functionality to victims of neuromuscular disorders. Although the most common application of this system has been communicating language, the properties and constraints of the linguistic domain have not to date been exploited when decoding b...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/1/016004
更新日期:2012-02-01 00:00:00
abstract:OBJECTIVE:A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user's mental task was independent of the device operation (e.g., the mental task was motor imagery and the...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/2/026024
更新日期:2013-04-01 00:00:00
abstract::Some issues in neuroscience can be addressed by building robot models of biological sensorimotor systems. What we can conclude from building models or simulations, however, is determined by a number of factors in addition to the central hypothesis we intend to test. These include the way in which the hypothesis is rep...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/3/3/R01
更新日期:2006-09-01 00:00:00
abstract:OBJECTIVE:The aim of this paper was to characterize brain non-stationarity during an auditory oddball task in schizophrenia (SCH). The level of non-stationarity was measured in the baseline and response windows of relevant tones in SCH patients and healthy controls. APPROACH:Event-related potentials were recorded from...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aa6e05
更新日期:2017-08-01 00:00:00
abstract:OBJECTIVE:Sleep spindles in the electroencephalogram (EEG) are significant in sleep analysis related to cognitive functions and neurological diseases, and thus are of great clinical interests. An automatic sleep spindle detection algorithm could help decrease the workload of visual inspection by sleep clinicians. APPR...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abd463
更新日期:2020-12-16 00:00:00
abstract::Rational selection of electrical stimulus parameters for an electronic retinal prosthesis requires knowledge of the electrophysiological responses of retinal neurons to electrical stimuli. In this study, we examined the effects of cathodal and anodal current pulses on the extracellularly recorded responses of OFF and ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/2/1/003
更新日期:2005-03-01 00:00:00
abstract::The aim of this paper is to use recent advances in the clinical understanding of the temporal evolution of seizure burden in neonates with hypoxic ischemic encephalopathy to improve the performance of automated detection algorithms. Probabilistic weights are designed from temporal locations of neonatal seizure events ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/4/046002
更新日期:2012-08-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCI) are becoming important tools for assistive technology, particularly through the use of motor imagery (MI) for aiding task completion. However, most existing methods of MI classification have been applied in a trial-wise fashion, with window sizes of approximately 2 s or more. A...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab57c0
更新日期:2020-01-31 00:00:00
abstract:OBJECTIVE:We recently developed soft neural interfaces enabling the delivery of electrical and chemical stimulation to the spinal cord. These stimulations restored locomotion in animal models of paralysis. Soft interfaces can be placed either below or above the dura mater. Theoretically, the subdural location combines ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaa87a
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVE:Implantable brain-computer interface (BCI) research promises improvements in human health and enhancements in quality of life. Informed consent of subjects is a central tenet of this research. Rapid advances in neuroscience, and the intimate connection between functioning of the brain and conceptions of the s...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/13/4/043001
更新日期:2016-08-01 00:00:00
abstract:OBJECTIVE:Due to low spatial resolution and poor signal-to-noise ratio of electroencephalogram (EEG), high accuracy classifications still suffer from lots of obstacles in the context of motor imagery (MI)-based brain-machine interface (BMI) systems. Particularly, it is extremely challenging to decode multiclass MI EEG ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aba7cd
更新日期:2020-08-11 00:00:00
abstract::The peripheral nerves of an amputee's residual limb still carry the information required to provide the robust, natural control signals needed to command a dexterous prosthetic limb. However, these signals are mixed in the volume conductor of the body and extracting them is an unmet challenge. A beamforming algorithm ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/5/056005
更新日期:2011-10-01 00:00:00
abstract:OBJECTIVE:Reliable chronic recordings from implanted neural probes remain a significant challenge; current silicon-based and microwire technologies experience a wide range of biotic and abiotic failure modes contributing to loss of signal quality. APPROACH:A multi-prong alternative strategy with potential to overcome ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/4/045002
更新日期:2013-08-01 00:00:00
abstract:OBJECTIVE:Deep brain stimulation (DBS) of the internal segment of the globus pallidus (GPi) in patients with Parkinson's disease and dystonia improves motor symptoms and quality of life. Traditionally, pallidal borders have been demarcated by electrophysiological microelectrode recordings (MERs) during DBS surgery. How...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab53ac
更新日期:2020-01-06 00:00:00
abstract::Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way ...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/10/3/031002
更新日期:2013-06-01 00:00:00
abstract::With the advent of new designs of visual prostheses for the blind, FDA is faced with developing guidance for evaluating their engineering, safety and patient performance. Visual prostheses are considered significant risk medical devices, and their use in human clinical trials must be approved by FDA under an investiga...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/4/1/S14
更新日期:2007-03-01 00:00:00
abstract:OBJECTIVE:Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH:Multi-contact cuff electrode...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/2/026002
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVE:There has recently been an increasing interest in local field potential (LFP) for brain-machine interface (BMI) applications due to its desirable properties (signal stability and low bandwidth). LFP is typically recorded with respect to a single unipolar reference which is susceptible to common noise. Several...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abce3c
更新日期:2020-11-26 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCIs) can help patients who have lost control over most muscles but are still conscious and able to communicate or interact with the environment. One of the most popular types of BCI is the P300-based BCI. With this BCI, users are asked to count the number of appearances of target s...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aa6213
更新日期:2017-06-01 00:00:00
abstract::Automatic spike sorting is a prerequisite for neuroscience research on multichannel extracellular recordings of neuronal activity. A novel spike sorting framework, combining efficient feature extraction and an unsupervised clustering method, is described here. Wavelet transform (WT) is adopted to extract features from...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/3/036003
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVE:In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/1/016011
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:Neural modulation is a fundamental tool for understanding and treating neurological and psychiatric diseases. However, due to the high-dimensional space, subject-specific responses, and variability within each subject, it is a major challenge to select the stimulation parameters that have the desired effect. ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abd048
更新日期:2020-12-03 00:00:00
abstract:OBJECTIVE:Multimodal neuroimaging approaches are beneficial to discover brain functionalities at high spatial and temporal resolution. In our work, a novel material composition of a microECoG device relying on Parylene HT and indium-tin-oxide (ITO) is presented, which facilitates two-photon imaging of Ca2+ signals and ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab603f
更新日期:2020-02-18 00:00:00
abstract:OBJECTIVE:Depression is a severe mental disorder. However, the neural mechanisms underlying affective interference (difficulties in directing attention away from negative distractors) in depression patients are still not well-understood. In particular, the connections between brain regions remain unclear. Using the emo...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aacdbb
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVE:To determine whether the estimated fraction and degree of distribution of visual responsive neurons in human intracranial microwire recordings depends upon the spike sorting method used. APPROACH:A large dataset of human intracranial microwire recordings from four brain areas was sorted into single unit acti...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab6cb8
更新日期:2020-04-09 00:00:00
abstract::Hybrid electro-optical neural stimulation is a novel paradigm combining the advantages of optical and electrical stimulation techniques while reducing their respective limitations. However, in order to fulfill its promise, this technique requires reduced variability and improved reproducibility. Here we used a compara...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/3/036003
更新日期:2012-06-01 00:00:00