Abstract:
:Exploiting the field response of magnetic tracers, magnetic particle imaging (MPI) allows direct, local quantification of the tracer concentration in bulk structures. Here, we investigated the use of characteristic field response functions to spatially resolve the absolute concentration of multiple nanoparticle species by simulation. In particular, using various drive and selection field strengths, we devised color MPI (i.e. cMPI) to quantify and disentangle MPI signals from the mixed Langevin particles of variable concentration and magnetic susceptibility. Specifically, the drive field strength was optimized to distinguish individual field responses from differently sized iron-oxide nanoparticles without compromising the image quality. The proposed cMPI technique is implementable on an existing MPI setup and can be used to quantify biophysical parameters including size-dependent bio-distribution and altered magnetic property of particles. The current study result, simultaneous visualization of the multiple magnetic tracers, theoretically validates the potential feasibility of cMPI as a versatile biosensor and contrast imaging method.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Han SH,Cho E,Lee DK,Cho G,Kim YR,Cho Hdoi
10.1088/0031-9155/59/21/6521subject
Has Abstractpub_date
2014-11-07 00:00:00pages
6521-36issue
21eissn
0031-9155issn
1361-6560journal_volume
59pub_type
杂志文章abstract::A mathematical procedure, using Fourier deconvolution, is described whereby diffusion-free proximity functions can be obtained from cloud-chamber data. Such non-diffused distributions can be used to obtain further microdosimetric and nanodosimetric quantities hitherto not available from experiments, thus making the cl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/11/004
更新日期:1988-11-01 00:00:00
abstract::We have developed and tested an MR-compatible gamma probe to simultaneously obtain anatomical information and functional information during surgery. The probe consists of a probe head, an optical fibre bundle and a photo-multiplier tube (PMT). The NaI(T1) scintillator contained in the probe head is connected to a 7 m ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/15/005
更新日期:2004-08-07 00:00:00
abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/16/4739
更新日期:2014-08-21 00:00:00
abstract::The aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture opt...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,随机对照试验
doi:10.1088/0031-9155/52/8/007
更新日期:2007-04-21 00:00:00
abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7105
更新日期:2020-03-06 00:00:00
abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/4/001
更新日期:2005-02-21 00:00:00
abstract::Due to high noise levels in the voxel kinetics, development of reliable parametric imaging algorithms remains one of most active areas in dynamic brain PET imaging, which in the vast majority of cases involves receptor/transporter studies with reversibly binding tracers. As such, the focus of this work has been to dev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/3/733
更新日期:2012-02-07 00:00:00
abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/15/5853
更新日期:2015-08-07 00:00:00
abstract::In this work, five 4D image-guidance strategies (two population, an offline adaptive and two online strategies) were evaluated that compensated for both inter- and intra-fraction variability such as changes to the baseline tumour position and respiratory pattern. None of the strategies required active motion compensat...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/1/017
更新日期:2007-01-07 00:00:00
abstract::This paper presents calculated specific absorption rate (SAR) dosimetry in 4 and 8 week Japanese pregnant-woman models exposed to plane waves over the frequency range of 10 MHz-1.5 GHz. Two types of 2 mm spatial-resolution pregnant-woman models comprised a woman model, which is similar to the average-sized Japanese ad...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/1/N01
更新日期:2010-01-07 00:00:00
abstract::A 3D anatomical computational model is developed to assess thermal effects due to exposure to the electromagnetic field required to power a new investigational active implantable microvalve for the treatment of glaucoma. Such a device, located in the temporal superior eye quadrant, produces a filtering bleb, which is ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5dae
更新日期:2017-05-07 00:00:00
abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abae07
更新日期:2020-12-04 00:00:00
abstract::The purpose of this study was to determine the performance of a single lutetium oxy-orthosilicate (LSO) crystal layer High Resolution Research Tomograph (HRRT) positron emission tomography (PET) scanner. The HRRT is a high resolution PET scanner designed for human brain and small animal imaging. The scanner consists o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/4/302
更新日期:2003-02-21 00:00:00
abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa58c9
更新日期:2017-03-07 00:00:00
abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/7/013
更新日期:2011-04-07 00:00:00
abstract::A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-st...
journal_title:Physics in medicine and biology
pub_type: 临床试验,杂志文章
doi:10.1088/0031-9155/50/4/011
更新日期:2005-02-21 00:00:00
abstract::Few quantitative data are available on the kinetics of polymerization reactions in polymer gel (PAG) dosimeters and their long-term stability. Post-irradiation polymerization reactions have been found to continue for several weeks, posing questions regarding dosimeter stability and its achievement. In this paper we re...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/8/301
更新日期:1999-08-01 00:00:00
abstract::Although the calculation of the surface average of the low-frequency current density distribution over a cross-section of 1 cm2 is required by ICNIRP guidelines, no reference averaging algorithm is indicated, neither in the ICNIRP guidelines nor in the Directive 2004/40/EC that is based on them. The lack of a general ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/15/013
更新日期:2009-08-07 00:00:00
abstract::In this paper, the influence of a dynamic variation in the ambient pressure on the subharmonic response of phospholipid-coated microbubbles was investigated. The ambient pressure in water was modulated by a 2.5 kHz acoustic wave with a peak amplitude of 15 kPa. We investigated the fundamental and subharmonic emissions...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/19/018
更新日期:2011-10-07 00:00:00
abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/3/007
更新日期:1981-05-01 00:00:00
abstract::Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is lim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab51c3
更新日期:2019-12-05 00:00:00
abstract::The derivative at constant direction is frequently used in inversion of cone-beam data. Several algorithms for computing the derivative have been proposed in the literature. The best algorithm to date has been proposed recently by Noo et al (2007 Phys. Med. Biol. 52 5393-414). In this note we propose a new, simple and...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/4/N01
更新日期:2011-02-21 00:00:00
abstract::The 'EXACT3D' positron tomograph, which is now in routine clinical research use, was developed with the aim of achieving unprecedented sensitivity, high spatial and temporal resolution and simplicity of design using proven detector technology. It consists of six rings of standard detector blocks (CTI/Siemens EXACT HR+...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/9/313
更新日期:2000-09-01 00:00:00
abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/4635
更新日期:2015-06-21 00:00:00
abstract::Mean glandular dose is the quantity used for dosimetry in mammography and depends on breast-related characteristics, such as thickness and density, and on the x-ray spectrum used for breast imaging. This work aims to present an experimentally-based method to derive polyenergetic normalized glandular dose coefficients ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab171a
更新日期:2019-05-10 00:00:00
abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac09a
更新日期:2018-05-17 00:00:00
abstract::Corrections for room scatter, [ksc(d, H)]RM, were derived using Monte Carlo methods for rooms of various sizes, including the brachytherapy treatment room, in which primary air kerma strength standardization of a remote afterloading microSelectron 192Ir HDR source was carried out, using a 60 cm3 spherical graphite ion...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/9/303
更新日期:2001-09-01 00:00:00
abstract::The aim of this study is the evaluation of on-the-fly volume of intersection computation for system's geometry modelling in 3D PET image reconstruction. For this purpose we propose a simple geometrical model in which the cubic image voxels on the given Cartesian grid are approximated with spheres and the rectangular t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/3/561
更新日期:2014-02-07 00:00:00
abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/11/3717
更新日期:2013-06-07 00:00:00
abstract::The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad516
更新日期:2018-08-20 00:00:00