Abstract:
:Purpose To compare the capability of pulmonary thin-section magnetic resonance (MR) imaging with ultrashort echo time (UTE) with that of standard- and reduced-dose thin-section computed tomography (CT) in nodule detection and evaluation of nodule type. Materials and Methods The institutional review board approved this study, and written informed consent was obtained from each patient. Standard- and reduced-dose chest CT (60 and 250 mA) and MR imaging with UTE were used to examine 52 patients; 29 were men (mean age, 66.4 years ± 7.3 [standard deviation]; age range, 48-79 years) and 23 were women (mean age, 64.8 years ± 10.1; age range, 42-83 years). Probability of nodule presence was assessed for all methods with a five-point visual scoring system. All nodules were then classified as missed, ground-glass, part-solid, or solid nodules. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and κ analysis was used to compare intermethod agreement for nodule type classification. Results There was no significant difference (F = 0.70, P = .59) in figure of merit between methods (standard-dose CT, 0.86; reduced-dose CT, 0.84; MR imaging with UTE, 0.86). There was no significant difference in sensitivity between methods (standard-dose CT vs reduced-dose CT, P = .50; standard-dose CT vs MR imaging with UTE, P = .50; reduced-dose CT vs MR imaging with UTE, P >.99). Intermethod agreement was excellent (standard-dose CT vs reduced-dose CT, κ = 0.98, P < .001; standard-dose CT vs MR imaging with UTE, κ = 0.98, P < .001; reduced-dose CT vs MR imaging with UTE, κ = 0.99, P < .001). Conclusion Pulmonary thin-section MR imaging with UTE was useful in nodule detection and evaluation of nodule type, and it is considered at least as efficacious as standard- or reduced-dose thin-section CT. © RSNA, 2017 Online supplemental material is available for this article.
journal_name
Radiologyjournal_title
Radiologyauthors
Ohno Y,Koyama H,Yoshikawa T,Kishida Y,Seki S,Takenaka D,Yui M,Miyazaki M,Sugimura Kdoi
10.1148/radiol.2017161037subject
Has Abstractpub_date
2017-08-01 00:00:00pages
562-573issue
2eissn
0033-8419issn
1527-1315journal_volume
284pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Fine needle, percutaneous aspiration of suspect lymph nodes was carried out in 29 patients during fluoroscopy. The correct positioning of the needle was assured if the node moved with the tip of the needle. In 29 patients, there were 65 successful aspirations and 29 failures. Anesthesia is recommended but care should ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.1.205
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:To identify computed tomographic (CT) findings that are associated with the effectiveness of nonsurgical treatment in patients with adhesive small-bowel obstruction ( SBO small-bowel obstruction ) that was initially treated medically. MATERIALS AND METHODS:The local institutional review board approved this ret...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132872
更新日期:2014-11-01 00:00:00
abstract::Transrectal catheter drainage was performed under radiologic guidance in eight patients with deep pelvic abscesses during a 7-month period. One patient underwent two procedures. In five patients, the abscess could not be palpated at rectal examination. Seven procedures were performed with fluoroscopic guidance. Transr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.185.3.1438770
更新日期:1992-12-01 00:00:00
abstract:PURPOSE:To compare the performance of apparent diffusion coefficient (ADC) measurement obtained with diffusion-weighted (DW) magnetic resonance (MR) imaging in the characterization of non-fat-containing T1 hyperintense renal lesions with that of contrast material-enhanced MR imaging, with histopathologic analysis and f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2513080724
更新日期:2009-06-01 00:00:00
abstract::Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016152036
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:To determine objectively the current standard of reporting for studies of computer-aided detection (CAD) for computed tomographic (CT) colonography by systematically reviewing published articles. MATERIALS AND METHODS:MEDLINE was searched to identify study articles meeting the inclusion criteria for describing...
journal_title:Radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1148/radiol.2461070121
更新日期:2008-02-01 00:00:00
abstract::An aluminum step-wedge filter placed far from the film cassette provides the constant variation of subject contrast required for quantitative sensitometry while virtually eliminating scatter radiations. Attenuation curves made with this configuration are almost exponentially linear. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.3.820
更新日期:1978-09-01 00:00:00
abstract::Normal kidney length was measured on the excretory urogram in 262 children 0 to 14.5 years of age (422 kidneys). While mean values were similar to those in the literature, the standard deviation (0.785 cm) was much lower than that reported previously. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.150.3.6695070
更新日期:1984-03-01 00:00:00
abstract::In ten rabbit ears the central auricular artery was percutaneously catheterized and subjected to doses of laser energy transmitted through a flexible optical fiber within the artery. Arterial occlusion was not produced in the initial three ears using energy levels less than 600 mW. Higher levels of laser energy, in th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.142.3.7199750
更新日期:1982-03-01 00:00:00
abstract::Shaped filters that are constructed of lead-loaded acrylic material for use in patient radiography are discussed. Use of the filters will result in improved overall image quality with significant exposure reduction to the patient (approximately a 2X reduction in breast exposure and a 3X reduction in thyroid gland expo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.146.3.6828700
更新日期:1983-03-01 00:00:00
abstract:PURPOSE:To compare the diagnostic usefulness of three-dimensional (3D) stereotaxic surface projection (SSP) with that of standard transaxial display in brain positron emission tomography (PET) in Alzheimer disease (AD). MATERIALS AND METHODS:Standard transaxial section display and 3D-SSP PET image sets obtained after ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.3.8628880
更新日期:1996-03-01 00:00:00
abstract::In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepuls...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.207.3.9609910
更新日期:1998-06-01 00:00:00
abstract::The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.215.1.r00ap10286
更新日期:2000-04-01 00:00:00
abstract::The diagnostic value of computed tomography (CT) and barium enema (BE) studies was evaluated prospectively in hospitalized patients with the presumptive diagnosis of acute sigmoid diverticulitis based on the presence of left-lower-quadrant pain and tenderness, fever, and leukocytosis. Of 56 patients, 11 had sigmoid di...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.1.2191360
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:To assess the diagnostic value of spinal ultrasonography (US) in pediatric patients. MATERIALS AND METHODS:The findings on 38 spinal US scans in 30 patients (mean age, 5.5 months) were compared with those of corresponding magnetic resonance (MR) images. RESULTS:MR imaging showed a normal spinal canal in 14 of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.200.2.8685330
更新日期:1996-08-01 00:00:00
abstract::Magnetic resonance (MR) imaging of the hip has been useful in the examination of patients for the presence of avascular necrosis (AVN). In the detection of AVN, MR imaging is more sensitive than computed tomography or nuclear scintigraphy. This study assessed the usefulness of MR imaging in the differentiation of AVN ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.1.3420260
更新日期:1988-10-01 00:00:00
abstract:PURPOSE:To evaluate the sensitivity and specificity of scintigraphy with technetium 99m white blood cells (WBC) for detection of colonic inflammation in children with and children without inflammatory bowel disease (IBD). MATERIALS AND METHODS:In 215 patients, uptake of 99mTc WBC in 3,440 bowel segments was graded. In...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.2.r99au45507
更新日期:1999-08-01 00:00:00
abstract::Two patients with large arteriovenous malformations (AVM) were successfully treated by transcatheter selective arterial embolization with Gelfoam. An extensive lumbar retroperitoneal acquired AVM was markedly reduced, eliminating any clinical evidence of a persistent left-to-right shunt. A large localized congenital A...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/15.3.609
更新日期:1975-06-01 00:00:00
abstract::The "comet tail" is a well-known ultrasound artifact that appears as a series of parallel bands radiating from a source. This artifact was observed in the gallbladder lumen in eight of 10 patients after extracorporeal shock wave lithotripsy of radiolucent calculi. To investigate the cause of the comet tail artifact, c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.1.2204960
更新日期:1990-10-01 00:00:00
abstract::Purpose To determine whether altered sodium (Na(+)) and chloride (Cl(-)) homeostasis can be visualized in periodic paralyses by using 7-T sodium 23 ((23)Na) and chlorine 35 ((35)Cl) magnetic resonance (MR) imaging. Materials and Methods Institutional review board approval and informed consent of all participants were ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016151617
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:To assess the benefit of adding diffusion-weighted (DW) imaging to gadoxetic acid-enhanced magnetic resonance (MR) imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma. MATERIALS AND METHODS:The institutional review board approved this retrospective study and waive...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13130009
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS:Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 h...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2242010847
更新日期:2002-08-01 00:00:00
abstract::Twenty-eight patients with prostatic carcinoma who underwent magnetic resonance (MR) imaging and subsequent radical prostatectomy were studied. The resected prostates were sectioned axially, and the whole-mount prostatic specimen was compared with the corresponding MR images. The carcinoma could be identified in 20 ca...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.3.2479050
更新日期:1989-12-01 00:00:00
abstract:PURPOSE:To determine the diagnostic accuracy of bedside chest radiography in patients who develop severe pulmonary complications while undergoing therapy for leukemia. MATERIALS AND METHODS:The authors studied 45 patients, aged 21 years and younger, who died of leukemia or of treatment complications and for whom autop...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.193.1.8090880
更新日期:1994-10-01 00:00:00
abstract::An anastomosis between the left renal and left ascending lumbar veins may appear as a mass on CT scans due to a varicosity where the veins separate. Intravenous injection of contrast material reveals the vascular nature of the mass. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.2.6739820
更新日期:1984-08-01 00:00:00
abstract::The medical records and radiographs of 62 patients admitted for smoke inhalation were reviewed to determine the value of the plain chest radiograph in the early detection of inhalation injury. Pulmonary edema resulting from the inhalation injury often leads to pulmonary insufficiency, and its early diagnosis is crucia...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.2.6622680
更新日期:1983-11-01 00:00:00
abstract:PURPOSE:To investigate and describe the anatomic distribution, imaging features, and pattern of metastatic spread of malignant gastrointestinal stromal tumors (GISTs). MATERIALS AND METHODS:The medical records of all patients at our institution with a histologic diagnosis of GIST were reviewed. Two radiologists with k...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2262011880
更新日期:2003-02-01 00:00:00
abstract::Forty papers on the radiologic detection of pituitary microadenomas were reviewed and used as the basis for a discussion of the sometimes tentative nature of published results in clinical research. Early articles on the radiologic evaluation of pituitary microadenomas, reporting favorable results with special plain fi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.1.6828750
更新日期:1983-04-01 00:00:00
abstract::Magnetic resonance (MR) imaging was performed in 17 patients, 11-84 years of age, referred for evaluation of possible osteomyelitis involving the appendicular skeleton. MR imaging permitted successful identification of osteomyelitis in ten patients (four acute, two subacute with Brodie abscess, two chronic, and two ac...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.166.1.3336680
更新日期:1988-01-01 00:00:00
abstract::Substantial technologic advances in radiation treatment planning and delivery have made possible exquisite tailoring of three-dimensional radiation dose distributions that conform to the tumor treatment volume while avoiding adjacent normal tissues. Although such highly precise treatment can increase the therapeutic r...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.11101688
更新日期:2011-10-01 00:00:00