T1 hyperintense renal lesions: characterization with diffusion-weighted MR imaging versus contrast-enhanced MR imaging.

Abstract:

PURPOSE:To compare the performance of apparent diffusion coefficient (ADC) measurement obtained with diffusion-weighted (DW) magnetic resonance (MR) imaging in the characterization of non-fat-containing T1 hyperintense renal lesions with that of contrast material-enhanced MR imaging, with histopathologic analysis and follow-up imaging as the reference standards. MATERIALS AND METHODS:Institutional review board approval was obtained for this HIPAA-compliant retrospective study, and the informed consent requirement was waived. Two independent observers retrospectively assessed MR images obtained in 41 patients with non-fat-containing T1 hyperintense renal lesions. The MR examination included acquisition of DW and contrast-enhanced T1-weighted images. For each index lesion, the observers assessed the (a) mean (+/- standard deviation) of ADC, (b) enhancement ratio, and (c) subtracted images for the presence of enhancement (confidence score, 1-5). Histopathologic analysis of renal cell carcinomas (RCCs) and follow-up imaging for benign lesions were the reference standards. ADCs of benign lesions and RCCs were compared. Receiver operating characteristic (ROC) curve analysis was performed to assess the accuracy of DW imaging, enhancement ratio, and subtraction for the diagnosis of RCC. RESULTS:A total of 64 lesions (mean diameter, 3.9 cm), including 38 benign T1 hyperintense cysts and 26 RCCs, were assessed. Mean ADCs of RCCs were significantly lower than those of benign cysts ([1.75 +/- 0.57] x 10(-3) mm(2)/sec vs [2.50 +/- 0.53] x 10(-3) mm(2)/sec, P < .0001). ADCs of solid and cystic portions of complex cystic RCCs were significantly different ([1.37 +/- 0.55] x 10(-3) mm(2)/sec vs [2.45 +/- 0.63] x 10(-3) mm(2)/sec, P < .0001). When data from both observers were pooled, area under the ROC curve, sensitivity, and specificity were 0.846, 71%, and 91%, respectively, for DW imaging; 0.865, 65%, and 96%, respectively, for enhancement ratio (at the excretory phase); and 0.861, 83%, and 89%, respectively, for subtraction (P = .48 and P = .85, respectively). The combination of DW imaging and subtraction resulted in area under the ROC curve, sensitivity, and specificity of 0.893, 87%, and 92%, respectively, with significantly improved reader confidence compared with subtraction alone (P = .041). CONCLUSION:The performance of DW imaging was equivalent to that of enhancement ratio in the characterization of T1 hyperintense renal lesions, with both methods having lower sensitivity than image subtraction without reaching significance.

journal_name

Radiology

journal_title

Radiology

authors

Kim S,Jain M,Harris AB,Lee VS,Babb JS,Sigmund EE,Rueff LE,Taouli B

doi

10.1148/radiol.2513080724

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

796-807

issue

3

eissn

0033-8419

issn

1527-1315

pii

2513080724

journal_volume

251

pub_type

杂志文章
  • Breast cancers: noninvasive method of preoperative localization with three-dimensional US and surface contour mapping.

    abstract::Formal ethical approval was granted by the local research ethics committee; all participants gave written consent. The purpose of the study was to prospectively evaluate the feasibility of a noninvasive method of breast tumor localization in 25 participants, based on the coregistration of three-dimensional (3D) ultras...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2452060906

    authors: Cash CJ,Coles CE,Treece GM,Purushotham AD,Britton P,Sinnatamby R,Gee AH,Prager RW

    更新日期:2007-11-01 00:00:00

  • Papillary process of the caudate lobe of the liver: sonographic appearance.

    abstract::The papillary process of the caudate lobe of the liver may appear separate from the liver and thus mimic lymph nodes or a pancreatic mass. In order to evaluate the sonographic appearance of this anatomic structure, 400 male and female patients with a mean age of 50 years were studied prospectively by means of ultrasou...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.3.2682770

    authors: Donoso L,Martínez-Noguera A,Zidan A,Lora F

    更新日期:1989-12-01 00:00:00

  • Characterization of prostate lesions as benign or malignant at multiparametric MR imaging: comparison of three scoring systems in patients treated with radical prostatectomy.

    abstract:PURPOSE:To compare the subjective Likert score to the Prostate Imaging Reporting and Data System (PIRADS) and morphology-location-signal intensity (MLS) scores for categorization of prostate lesions as benign or malignant at multiparametric magnetic resonance (MR) imaging. MATERIALS AND METHODS:Two hundred fifteen pat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14131584

    authors: Vaché T,Bratan F,Mège-Lechevallier F,Roche S,Rabilloud M,Rouvière O

    更新日期:2014-08-01 00:00:00

  • Display of CT studies on a two-screen electronic workstation versus a film panel alternator: sensitivity and efficiency among radiologists.

    abstract::Prototype electronic workstations incorporated in networks linking computed tomographic (CT) and magnetic resonance imaging systems are being developed. The authors compared observer efficiency and sensitivity in reading body CT studies from a two-screen workstation (1,000-line monitors and 12-bit dynamic range in ima...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.2305060

    authors: Foley WD,Jacobson DR,Taylor AJ,Goodman LR,Stewart ET,Gurney JW,Stroka D

    更新日期:1990-03-01 00:00:00

  • MR imaging evaluation of cardiovascular risk in metabolic syndrome.

    abstract::Metabolic syndrome has become an important public health problem and has reached epidemic proportions globally. Metabolic syndrome is characterized by a cluster of metabolic abnormalities in an individual, with insulin resistance as the main characteristic. The major adverse consequence of metabolic syndrome is cardio...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.12110772

    authors: van der Meer RW,Lamb HJ,Smit JW,de Roos A

    更新日期:2012-07-01 00:00:00

  • Hepatic malignancies: usefulness of acquisition of multiple arterial and portal venous phase images at dynamic gadolinium-enhanced MR imaging.

    abstract:PURPOSE:To determine whether liver tumor detection is increased by acquiring multiple dynamic arterial phase and portal venous phase magnetic resonance (MR) images. MATERIALS AND METHODS:Dynamic MR imaging was performed in 205 patients at 1.5 T with use of a fast spoiled gradient-echo technique (repetition time, 9-12 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.2.8888220

    authors: Peterson MS,Baron RL,Murakami T

    更新日期:1996-11-01 00:00:00

  • Using computed tomography of the brain to correlate low white-matter attenuation with early gestational age in neonates.

    abstract::Computed tomographic brain scans of the newborn exhibit relatively greater lucency of white matter compared to the mature patient. This study correlated the x-ray attenuation of white matter with gestational age in 23 neonates, both premature and term. The gray-white matter attenuation difference was calculated and pl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.1.7208910

    authors: Brant-Zawadzki M,Enzmann DR

    更新日期:1981-04-01 00:00:00

  • Dentate Nucleus Signal Intensity Increases Following Repeated Gadobenate Dimeglumine Administrations: A Retrospective Analysis.

    abstract::Background Increased cerebral signal intensity (SI) has been reported in patients undergoing MRI with gadolinium-based contrast agents (GBCAs). Published data on gadobenate dimeglumine have been somewhat contradictory. Purpose To evaluate the relationship between dosage of gadobenate dimeglumine and SI change at MRI f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020190246

    authors: Nguyen NC,Molnar TT,Cummin LG,Kanal E

    更新日期:2020-07-01 00:00:00

  • Intraductal papillary mucinous tumors of the pancreas: helical CT with histopathologic correlation.

    abstract:PURPOSE:To evaluate the accuracy of preoperative computed tomography (CT) in predicting the location and type of ductal involvement and malignant transformation in intraductal papillary mucinous (IPM) pancreatic tumors and to determine the predictive factors for malignancy at CT. MATERIALS AND METHODS:The helical CT s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.3.r00dc24757

    authors: Taouli B,Vilgrain V,Vullierme MP,Terris B,Denys A,Sauvanet A,Hammel P,Menu Y

    更新日期:2000-12-01 00:00:00

  • Presacral abscesses: percutaneous transperineal drainage with use of bone landmarks and fluoroscopic guidance.

    abstract::Presacral abscesses developed in two men (aged 59 and 76 years) after abdominoperineal resection. Computed tomography was performed to demonstrate the distance from the abscess to the perineum and the distance of the abscess anterior to the sacrum. Then, lateral and anteroposterior fluoroscopy was performed to guide t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.2.8284420

    authors: Michalson AE,Brown BP,Warnock NG,Simonson TM

    更新日期:1994-02-01 00:00:00

  • Congenital diaphragmatic hernia diagnosed prenatally by ultrasound.

    abstract::Seven infants born at our institution between July 1979 and June 1982 had congenital diaphragmatic hernia (CDH). Four cases of CDH were correctly identified by fetal ultrasonography. Diagnosis relied upon the demonstration of abdominal organs within the thorax. During this period, no false positive diagnoses of CDH we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.1.6856820

    authors: Chinn DH,Filly RA,Callen PW,Nakayama DK,Harrison MR

    更新日期:1983-07-01 00:00:00

  • Degeneration of the ipsilateral substantia nigra after striatal infarction: evaluation with MR imaging.

    abstract:PURPOSE:To evaluate the degeneration of the ipsilateral substantia nigra after striatal infarction by using magnetic resonance (MR) imaging. MATERIALS AND METHODS:Twenty-five adult patients with embolic cerebral infarction of the middle cerebral artery distribution underwent MR imaging 0-4, 5-9, 12-15, and 27-29 days ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.3.9280270

    authors: Ogawa T,Okudera T,Inugami A,Noguchi K,Kado H,Yoshida Y,Uemura K

    更新日期:1997-09-01 00:00:00

  • White matter degeneration with Unverricht-Lundborg progressive myoclonus epilepsy: a translational diffusion-tensor imaging study in patients and cystatin B-deficient mice.

    abstract:PURPOSE:To study white matter (WM) changes in patients with Unverricht-Lundborg progressive myoclonus epilepsy (EPM1) caused by mutations in the cystatin B gene and in the cystatin B-deficient (Cstb-/-) mouse model and to validate imaging findings with histopathologic analysis of mice. MATERIALS AND METHODS:Informed c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13122458

    authors: Manninen O,Koskenkorva P,Lehtimäki KK,Hyppönen J,Könönen M,Laitinen T,Kalimo H,Kopra O,Kälviäinen R,Gröhn O,Lehesjoki AE,Vanninen R

    更新日期:2013-10-01 00:00:00

  • Lipid in renal clear cell carcinoma: detection on opposed-phase gradient-echo MR images.

    abstract:PURPOSE:To determine if comparison of in-phase and opposed-phase gradient-echo magnetic resonance (MR) images enables detection of lipid in renal clear cell carcinoma. MATERIALS AND METHODS:A retrospective search of MR and pathologic records identified 43 patients with biopsy-proved renal masses who underwent in-phase...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.1.9314970

    authors: Outwater EK,Bhatia M,Siegelman ES,Burke MA,Mitchell DG

    更新日期:1997-10-01 00:00:00

  • Malignant liver tumors treated with MR imaging-guided laser-induced thermotherapy: technique and prospective results.

    abstract:PURPOSE:To evaluate magnetic resonance (MR) imaging-guided laser-induced thermotherapy (LITT) of liver metastases. MATERIALS AND METHODS:In a phase II study, 20 patients with 33 metastases from colorectal carcinoma (75%) or other primary tumors (25%) underwent LITT. MR thermometry performed with fast low-angle shot se...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.196.1.7540310

    authors: Vogl TJ,Müller PK,Hammerstingl R,Weinhold N,Mack MG,Philipp C,Deimling M,Beuthan J,Pegios W,Riess H

    更新日期:1995-07-01 00:00:00

  • Differentiation of acute osteoporotic and malignant compression fractures of the spine: use of additive qualitative and quantitative axial diffusion-weighted MR imaging to conventional MR imaging at 3.0 T.

    abstract:PURPOSE:To retrospectively determine the value of adding qualitative and quantitative axial diffusion-weighted (DW) imaging to standard spine magnetic resonance (MR) imaging to differentiate between acute osteoporotic and malignant compression fractures at 3.0 T. MATERIALS AND METHODS:The institutional ethics committe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13130399

    authors: Sung JK,Jee WH,Jung JY,Choi M,Lee SY,Kim YH,Ha KY,Park CK

    更新日期:2014-05-01 00:00:00

  • Ultrasonography of small hepatic tumors using high-resolution linear-array real-time instruments.

    abstract::Abdominal ultrasonography using a high-resolution linear-array real-time scanner was compared to computed tomography, celiac arteriography, and radionuclide imaging in 24 patients with a total of 33 hepatocellular carcinomas (HCC), 10 patients with cavernous hemangioma (12 tumors), and 2 patients with metastatic carci...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.3.6320260

    authors: Sheu JC,Sung JL,Chen DS,Yu JY,Wang TH,Su CT,Tsang YM

    更新日期:1984-03-01 00:00:00

  • Deep venous thrombosis: longitudinal study with duplex US.

    abstract::Forty-nine patients with deep venous thrombosis (DVT) of the lower limb were studied with repeated duplex ultrasound (US) for at least 1 year or until the vein became normal at US. Standard anticoagulant therapy was given for 3 months. In 36 patients, the veins became normal within 1 year. The likelihood of normalizat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.1.2006290

    authors: Mantoni M

    更新日期:1991-04-01 00:00:00

  • Postphlebographic thrombosis: a double-blind study with methylglucamine metrizoate and metrizamide.

    abstract::A double-blind, randomized study was conducted in 170 patients to compare the effects of two hypertonic contrast media in phlebography of the leg: one was ionic [methylglucamine metrizoate (Isopaque Cerebral, 280 mg I/mI)] and the other nonionic [metrizamide (Amipaque, 280 mg I/mI)]. Ninety patients who showed no veno...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.140.3.7025090

    authors: Laerum F,Holm HA

    更新日期:1981-09-01 00:00:00

  • Radiographic findings of osteoarthritis versus arthroscopic findings of articular cartilage degeneration in the tibiofemoral joint.

    abstract:PURPOSE:To retrospectively correlate radiographic findings of osteoarthritis of the tibiofemoral joint with arthroscopic findings of articular cartilage degeneration within the tibiofemoral joint in patients with chronic knee pain. MATERIALS AND METHODS:The study was performed in compliance with HIPAA regulations. App...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2393050584

    authors: Kijowski R,Blankenbaker DG,Stanton PT,Fine JP,De Smet AA

    更新日期:2006-06-01 00:00:00

  • Chest radiography: a survey of techniques and exposure levels currently used.

    abstract::In diagnostic radiology, the routine measurement of exposure levels for a reference patient is an important part of an effective quality assurance program. In the United States, chest radiography is the most frequent examination and has the lowest exposure level of all radiologic examinations. We estimated the amount ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.4011920

    authors: Butler PF,Conway BJ,Suleiman OH,Koustenis GH,Showalter CK

    更新日期:1985-08-01 00:00:00

  • Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society.

    abstract::This report is to complement the original Fleischner Society recommendations for incidentally detected solid nodules by proposing a set of recommendations specifically aimed at subsolid nodules. The development of a standardized approach to the interpretation and management of subsolid nodules remains critically impor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120628

    authors: Naidich DP,Bankier AA,MacMahon H,Schaefer-Prokop CM,Pistolesi M,Goo JM,Macchiarini P,Crapo JD,Herold CJ,Austin JH,Travis WD

    更新日期:2013-01-01 00:00:00

  • Posttraumatic arterial priapism in children: management with embolization.

    abstract:PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784590

    authors: Miller SF,Chait PG,Burrows PE,Steckler RE,Khoury AE,McLorie GA,Connolly BL,Pereira JK

    更新日期:1995-07-01 00:00:00

  • Hypervascular hepatic metastases: CT evaluation.

    abstract::Recent reports have indicated that non-contrast material-enhanced scans are of less value than urographic contrast material-enhanced studies in the computed tomographic (CT) evaluation of hepatic metastases. The authors retrospectively reviewed the CT scans of 28 patients with hypervascular liver metastases to determi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.1.3024210

    authors: Bressler EL,Alpern MB,Glazer GM,Francis IR,Ensminger WD

    更新日期:1987-01-01 00:00:00

  • Early-stage hepatocellular carcinoma: radiofrequency ablation combined with chemoembolization versus hepatectomy.

    abstract:PURPOSE:To retrospectively evaluate the long-term results of radiofrequency (RF) ablation combined with chemoembolization (combination therapy) as compared with hepatectomy for the treatment of early-stage hepatocellular carcinoma (HCC). MATERIALS AND METHODS:The study was approved by the institutional review board, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2471070818

    authors: Yamakado K,Nakatsuka A,Takaki H,Yokoi H,Usui M,Sakurai H,Isaji S,Shiraki K,Fuke H,Uemoto S,Takeda K

    更新日期:2008-04-01 00:00:00

  • Aplasia or hypoplasia of the pancreatic uncinate process: comparison in patients with and patients without intestinal nonrotation.

    abstract:PURPOSE:To investigate whether the pancreatic uncinate process is hypoplastic in patients with intestinal nonrotation, and to evaluate the association of hypoplasia or aplasia of the uncinate process with mesenteric vascular inversion. MATERIALS AND METHODS:Computed tomographic (CT) scans of the pancreas in five patie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.2.9356640

    authors: Inoue Y,Nakamura H

    更新日期:1997-11-01 00:00:00

  • Neodymium yttrium aluminum garnet laser treatment of hemobilia via a percutaneous biliary catheter track.

    abstract::The authors describe the use of neodymium yttrium aluminum garnet laser introduced via a percutaneous catheter track for photocoagulation of a bleeding bile duct tumor. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.3.6878710

    authors: Carpenter CM,Bowers JH,Luers PR,Dixon JA,Miller FJ

    更新日期:1983-09-01 00:00:00

  • A data acquisition system for three-dimensional treatment planning.

    abstract::The authors describe a coordinate measuring device developed to simplify manual acquisition of the digital information required for computerized three-dimensional treatment planning. This system has been used for two years and shown to be both fast and accurate. The time needed to digitize contour data is reduced to a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.187

    authors: Mantel J,Perry H,Weinkam JJ

    更新日期:1975-04-01 00:00:00

  • Effect of Change in Portal Venous Blood Flow Rates on the Performance of a 2.45-GHz Microwave Ablation Device.

    abstract:PURPOSE:To investigate the effect of change in portal venous blood flow rates on the size and shape of ablations created by a 2.45-GHz microwave ablation device. MATERIALS AND METHODS:This study was exempt from review by the institutional animal care and use committee. An in vitro bovine liver model perfused with auto...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150102

    authors: Dodd GD 3rd,Kreidler SM,Lanctot AC,Glueck DH

    更新日期:2015-12-01 00:00:00

  • Cervical spine: three-dimensional MR imaging with magnetization transfer prepulsed turbo field echo techniques.

    abstract::In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepuls...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.3.9609910

    authors: Melhem ER,Caruthers SD,Jara H

    更新日期:1998-06-01 00:00:00