Posttraumatic arterial priapism in children: management with embolization.

Abstract:

PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embolization. Color Doppler sonography was performed in the last three patients. RESULTS:Selective angiography showed an intracavernosal arteriovenous fistula in two patients, pseudoaneurysm of the cavernosal artery in two patients, and asymmetric cavernosal arterial flow in the other patient. After successful embolization, detumescence was achieved in all patients. Color Doppler sonography enabled localization and characterization of the lesion causing the priapism in the three patients. CONCLUSION:Angiography with selective embolization is a safe and effective method to correct posttraumatic priapism in children. Color Doppler sonography is a valuable preangiographic study, as it allows for characterization and localization of the causative lesion and obviates diagnostic cavernosal aspiration.

journal_name

Radiology

journal_title

Radiology

authors

Miller SF,Chait PG,Burrows PE,Steckler RE,Khoury AE,McLorie GA,Connolly BL,Pereira JK

doi

10.1148/radiology.196.1.7784590

subject

Has Abstract

pub_date

1995-07-01 00:00:00

pages

59-62

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

196

pub_type

杂志文章
  • A data acquisition system for three-dimensional treatment planning.

    abstract::The authors describe a coordinate measuring device developed to simplify manual acquisition of the digital information required for computerized three-dimensional treatment planning. This system has been used for two years and shown to be both fast and accurate. The time needed to digitize contour data is reduced to a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.187

    authors: Mantel J,Perry H,Weinkam JJ

    更新日期:1975-04-01 00:00:00

  • Aneurysm clips: evaluation of MR imaging artifacts at 1.5 T.

    abstract::Magnetic resonance (MR) imaging-related artifacts associated with five different aneurysm clips made of five different metals (commercially pure titanium, titanium alloy, Phynox, Elgiloy, and cobalt alloy) were evaluated. Aneurysm clips made of commercially pure titanium and titanium alloy produced the smallest artifa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.209.2.9807590

    authors: Shellock FG,Kanal E

    更新日期:1998-11-01 00:00:00

  • Abdominal helical CT: evaluation of optimal doses of intravenous contrast material--a prospective randomized study.

    abstract:PURPOSE:To determine the optimal dose of intravenous contrast material for helical computed tomography (CT) of the abdomen on the basis of patient weight. MATERIALS AND METHODS:A prospective randomized study of helical CT of the abdomen was performed by using different doses of intravenous contrast material in 221 pat...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.216.3.r00se26718

    authors: Yamashita Y,Komohara Y,Takahashi M,Uchida M,Hayabuchi N,Shimizu T,Narabayashi I

    更新日期:2000-09-01 00:00:00

  • Physical and clinical evaluation of new high-strip-density radiographic grids.

    abstract::The imaging performance of new high-strip-density (HSD) grids having 57 lines/cm was compared with that of conventional low-strip-density (LSD) grids having 33 or 40 lines/cm. The unique advantage of HSD grids is that, under most standard radiographic conditions, the grid lines are not noticeable on the final image, e...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.147.2.6340160

    authors: Doi K,Frank PH,Chan HP,Vyborny CJ,Makino S,Iida N,Carlin M

    更新日期:1983-05-01 00:00:00

  • Radiation therapy for pineal tumors and suprasellar germinomas.

    abstract::Data on all patients with pineal body tumors and suprasellar germinomas seen at the University of California--San Francisco over a 25-year period were reviewed. Of 19 patients treated, 15 are still alive. Although treatment techniques varied, all patients received irradiation to the primary tumor site but not to the s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.1.221

    authors: Wara WM,Fellows CF,Sheline GE,Wilson CB,Townsend JJ

    更新日期:1977-07-01 00:00:00

  • Focal epileptiform activity in the brain: detection with spike-related functional MR imaging--preliminary results.

    abstract::The purpose of this study was to develop a spike-related functional magnetic resonance (MR) imaging method to detect epileptic brain activity. Correlations between simultaneous spike-related functional MR imaging and electroencephalographic (EEG) recordings were performed in 10 patients with focal epilepsy. Postproces...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2233010360

    authors: Jäger L,Werhahn KJ,Hoffmann A,Berthold S,Scholz V,Weber J,Noachtar S,Reiser M

    更新日期:2002-06-01 00:00:00

  • Prediction of esophageal varices in patients with cirrhosis: usefulness of three-dimensional MR elastography with echo-planar imaging technique.

    abstract:PURPOSE:To determine the diagnostic performance of magnetic resonance (MR) elastography in comparison to spleen length and dynamic contrast material-enhanced (DCE) MR imaging in association with esophageal varices in patients with liver cirrhosis by using endoscopy as the reference standard. MATERIALS AND METHODS:This...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14130916

    authors: Shin SU,Lee JM,Yu MH,Yoon JH,Han JK,Choi BI,Glaser KJ,Ehman RL

    更新日期:2014-07-01 00:00:00

  • Surface shield: device to reduce personnel radiation exposure.

    abstract::A simple device is described that can reduce personnel exposure from scatter radiation by up to 75%. The device consists of an oblong piece of shielding (0.75-mm lead equivalent) that is taped to the side of the patient during percutaneous renal stone removal and other interventional procedures. Contrary to other shie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3704160

    authors: Young AT,Morin RL,Hunter DW,Nelson KL,Cardella JF,Castaneda-Zuniga WR,Amplatz K

    更新日期:1986-06-01 00:00:00

  • Intravoxel Incoherent Motion Diffusion-weighted Imaging of Multiple Myeloma Lesions: Correlation with Whole-Body Dynamic Contrast Agent-enhanced MR Imaging.

    abstract:PURPOSE:To correlate intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters with the enhancement patterns of bone marrow and focal lesion obtained on whole-body (WB) dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) images in patients with stage-III multiple myeloma (MM) before and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141728

    authors: Bourillon C,Rahmouni A,Lin C,Belhadj K,Beaussart P,Vignaud A,Zerbib P,Pigneur F,Cuenod CA,Bessalem H,Cavet M,Boutekadjirt A,Haioun C,Luciani A

    更新日期:2015-12-01 00:00:00

  • Intracranial tumors: unexpected uptake of I-123 HIPDM.

    abstract::I-123 HIPDM is a brain imaging agent thought to reflect cerebral cortical perfusion. Increased uptake of I-123 HIPDM occurred unexpectedly in two cases of intracranial tumors. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.2.3763910

    authors: McVeigh MC,Merchut MP,Karesh SM,Ghobrial MW,Dillehay GL

    更新日期:1986-11-01 00:00:00

  • Femoral MR angiography versus conventional angiography: preliminary results.

    abstract:PURPOSE:To develop a bilateral femoral magnetic resonance (MR) angiographic examination that would include the aortic bifurcation to the ankle. MATERIALS AND METHODS:Thirty-seven patients underwent conventional angiography and the bilateral femoral MR angiographic examination. Two-dimensional time-of-flight angiograph...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372190

    authors: Quinn SF,Demlow TA,Hallin RW,Eidemiller LR,Szumowski J

    更新日期:1993-10-01 00:00:00

  • Detection of colonic polyps on single-contrast barium enema study: emphasis on the elderly.

    abstract::A systems approach was employed to improve results of the single-contrast barium enema examination for detection of colonic polyps. Improvements were made in each of the following areas: radiographic-fluoroscopic equipment, fluoroscopic-television images, screen-film combinations, barium suspensions, examination techn...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3602370

    authors: Gelfand DW,Chen YM,Ott DJ

    更新日期:1987-08-01 00:00:00

  • Contrast agents lower ventricular fibrillation threshold.

    abstract::Ventricular fibrillation thresholds were measured in anesthetized, closed-chest dogs during the injection of Renografin 76 or Conray 400 into the left coronary artery. Both agents significantly lowered fibrillation threshold--Renografin to 58 +/- 7%; Conray to 20 +/- 5% of control, respectively. The experimental metho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.215

    authors: Wolf GL,Kraft L,Kilzer K

    更新日期:1978-10-01 00:00:00

  • A new scintigraphic technique for assessment of right atrial function.

    abstract::Gated radionuclide imaging with 99mTc-labeled red blood cells was employed to assess changes in right atrial (RA) volume in 17 subjects. Studies were repeated within two hours in five of 12 normal subjects and at two and ten days after infarction in five patients. Time-activity curves were generated for the RA and rig...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.3.7232740

    authors: Marmor A,Biello DR,Sampathkumaran KS,Geltman EM,Siegel BA,Roberts R

    更新日期:1981-06-01 00:00:00

  • Aortobronchial fistula as a complication of surgery for correction of congenital aortic anomalies.

    abstract::An aortobronchial fistula is a rare condition that is invariably fatal if not diagnosed and surgically treated. Aortic aneurysms, both atherosclerotic and infective, were the main causes in the originally described cases. However, thoracic cardiovascular surgery has recently become the predominant cause. The authors d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.2.2326460

    authors: Garniek A,Morag B,Schmahmann S,Rubinstein ZJ

    更新日期:1990-05-01 00:00:00

  • "Tumoral pseudoblush" identified within gliomas at high-spatial-resolution ultrahigh-field-strength gradient-echo MR imaging corresponds to microvascularity at stereotactic biopsy.

    abstract:PURPOSE:To use directed biopsy sampling to determine whether microvascular assessment within gliomas, by means of ultrahigh-field-strength high-spatial-resolution gradient-echo (GRE) magnetic resonance (MR) imaging at 8 T, correlates with histopathologic assessment of microvascularity. MATERIALS AND METHODS:The study ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12110799

    authors: Christoforidis GA,Yang M,Abduljalil A,Chaudhury AR,Newton HB,McGregor JM,Epstein CR,Yuh WT,Watson S,Robitaille PM

    更新日期:2012-07-01 00:00:00

  • Clinical and radiographic manifestations of aortoesophageal fistulas.

    abstract::Aneurysms of the thoracic aorta simulated primary esophageal disease both clinically and radiographically in 5 patients. Four had an aortoesophageal fistula at the time of presentation; endoscopic biopsy of a presumed esophageal tumor precipitated hematemesis in the fifth patient. In retrospect, the fistulas were demo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.3.7302210

    authors: Baron RL,Koehler RE,Gutierrez FR,Forrest JV,Weyman PJ

    更新日期:1981-12-01 00:00:00

  • Colorectal carcinoma metastases in liver: laser-induced interstitial thermotherapy--local tumor control rate and survival data.

    abstract:PURPOSE:To evaluate the local tumor control and survival data for magnetic resonance (MR) imaging-guided laser-induced interstitial thermotherapy (LITT) of colorectal liver metastases. MATERIALS AND METHODS:MR imaging-guided LITT was performed in 603 patients (mean age, 61.2 years) with 1,801 liver metastases of color...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2302020646

    authors: Vogl TJ,Straub R,Eichler K,Söllner O,Mack MG

    更新日期:2004-02-01 00:00:00

  • Differentiation of recurrent glioblastoma multiforme from radiation necrosis after external beam radiation therapy with dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging.

    abstract:PURPOSE:To investigate whether cerebral blood volume (CBV), peak height (PH), and percentage of signal intensity recovery (PSR) measurements derived from the results of T2-weighted dynamic susceptibility-weighted contrast material-enhanced (DSC) magnetic resonance (MR) imaging performed after external beam radiation th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2532090007

    authors: Barajas RF Jr,Chang JS,Segal MR,Parsa AT,McDermott MW,Berger MS,Cha S

    更新日期:2009-11-01 00:00:00

  • Facet joint menisci of the cervical spine: correlative MR imaging and cryomicrotomy study.

    abstract::An analysis of the cervical facet joint menisci was done in which cryomicrotomy sections were correlated with magnetic resonance (MR) images. In parasagittal anatomic sections in ten cadavers, 10-69 years of age at death, four types of meniscus were defined. Type 1 was a thin washer of dense connective tissue covering...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.1.3588930

    authors: Yu SW,Sether L,Haughton VM

    更新日期:1987-07-01 00:00:00

  • Influence of image acquisition parameters on CT artifacts and polyp depiction in spiral CT colonography: in vitro evaluation.

    abstract:PURPOSE:To quantify the effects of spiral computed tomographic (CT) acquisition parameters on the magnitude of three-dimensional (3D) rippling artifacts and polyp depiction. MATERIALS AND METHODS:An in vitro colon phantom was constructed with air-filled acrylic cylinders that contained synthetic polyps of 3-13 mm. The...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.1.r00oc13165

    authors: Whiting BR,McFarland EG,Brink JA

    更新日期:2000-10-01 00:00:00

  • Complementary role of Tc-99m-diethyl-IDA and ultrasound in large and small duct biliary tract obstruction.

    abstract::Fifty-one patients underwent both radionuclide and ultrasound studies of the hepatobiliary system. Eleven patients had large bile duct obstruction, six had intrahepatic diffuse small duct obstruction, and 37 had no obstruction. In all 11 patients with large duct obstruction, the radionuclide images were abnormal, but ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.1.7455080

    authors: Klingensmith WC 3rd,Johnson ML,Kuni CC,Dunne MG,Fritzberg AR

    更新日期:1981-01-01 00:00:00

  • Vertebral bone mineral analysis: an integrated approach with CT.

    abstract::In the assessment of vertebral bone mineral density (BMD) with quantitative computed tomography, accuracy is limited by systematic errors caused by beam-hardening effects and unknown marrow and fat concentrations in trabecular bone. Reproducibility depends on precise repositioning of the patient, selection of the regi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3602380

    authors: Kalender WA,Klotz E,Suess C

    更新日期:1987-08-01 00:00:00

  • Intussusception: ability of fluoroscopic images obtained during air enemas to depict lead points and other abnormalities.

    abstract:PURPOSE:To evaluate the ability of fluoroscopic images obtained during air enemas to depict or exclude lead points of intussusceptions and other abnormalities that require surgical treatment in the absence of intussusception. MATERIALS AND METHODS:The clinical, radiologic, surgical, and pathologic findings were review...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.2.7480700

    authors: Miller SF,Landes AB,Dautenhahn LW,Pereira JK,Connolly BL,Babyn PS,Alton DJ,Daneman A

    更新日期:1995-11-01 00:00:00

  • Volume detection threshold: quantitative comparison of computed radiography and screen-film radiography in detection of pneumothoraces in an animal model that simulates the neonate.

    abstract:PURPOSE:To quantitatively compare computed radiography (CR) and screen-film radiography (SFR) in the detection of pneumothorax in an animal model that simulates the neonate. MATERIALS AND METHODS:Three rabbits underwent placement of 5-F catheters in the right pleural space. Eight CR and eight SFR images were obtained....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.3.7862970

    authors: Don S,Cohen MD,Kruger RA,Winkler TA,Katz BP,Li W,Dreesen RG,Kennan N,Tarver R,Klatte EC

    更新日期:1995-03-01 00:00:00

  • Corrosive esophageal stricture: safety and effectiveness of balloon dilation.

    abstract::The safety and long-term effectiveness of fluoroscopically guided balloon dilation for corrosive esophageal stricture was evaluated in 22 patients with a follow-up period of more than 1 year (range, 13-52 months). The average interval between corrosive agent ingestion and initial balloon dilation was 18 years (range, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.2.1620830

    authors: Song HY,Han YM,Kim HN,Kim CS,Choi KC

    更新日期:1992-08-01 00:00:00

  • Fractures of the hands and feet in child abuse: imaging and pathologic features.

    abstract:PURPOSE:To determine the imaging and histopathologic appearance of fractures of the hands and feet in abused infants. MATERIALS AND METHODS:The imaging findings in 11 abused infants with fractures of the hands and feet were examined retrospectively. All 11 infants underwent skeletal surveys; five infants also underwen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.1.9122400

    authors: Nimkin K,Spevak MR,Kleinman PK

    更新日期:1997-04-01 00:00:00

  • The Alzheimer structural connectome: changes in cortical network topology with increased amyloid plaque burden.

    abstract:PURPOSE:To evaluate differences in the structural connectome among patients with normal cognition (NC), mild cognitive impairment (MCI), and Alzheimer disease (AD) and to determine associations between the structural connectome and cortical amyloid deposition. MATERIALS AND METHODS:Patients enrolled in a multicenter b...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.14132593

    authors: Prescott JW,Guidon A,Doraiswamy PM,Roy Choudhury K,Liu C,Petrella JR,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2014-10-01 00:00:00

  • Clinically isolated syndrome suggestive of multiple sclerosis: voxelwise regional investigation of white and gray matter.

    abstract:PURPOSE:To quantify white matter (WM) and gray matter (GM) damage in patients who presented with clinically isolated syndrome (CIS), which is suggestive of multiple sclerosis (MS), by combining volume-based morphometry (VBM) and tract-based spatial statistics (TBSS). MATERIALS AND METHODS:This prospective HIPAA-compli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2541090817

    authors: Raz E,Cercignani M,Sbardella E,Totaro P,Pozzilli C,Bozzali M,Pantano P

    更新日期:2010-01-01 00:00:00

  • Application of image-guided surface coil P-31 MR spectroscopy to human liver, heart, and kidney.

    abstract::Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface coil spectroscopy or rotating frame experiments, in which the extent of tissue sampled critically depends on surface coil placement. The authors' goal was to mod...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.2.3051120

    authors: Matson GB,Twieg DB,Karczmar GS,Lawry TJ,Gober JR,Valenza M,Boska MD,Weiner MW

    更新日期:1988-11-01 00:00:00