Abstract:
:Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface coil spectroscopy or rotating frame experiments, in which the extent of tissue sampled critically depends on surface coil placement. The authors' goal was to modify the surface coil image-selected in vivo spectroscopy (ISIS) experiment to accomplish three-dimensional volume selection through application of selective pulses in the presence of B0 gradients. Advantages of ISIS include the ability to use proton images to define the volume of interest (VOI) and reduced dependence on exact positioning of the surface coil. However, rapid replication of the surface coil ISIS experiment can cause spectral contamination from signals originating outside the VOI. A modified version of the ISIS experiment was developed to alleviate contamination under conditions of rapid replication. Applications of localized P-31 MR spectroscopy for observation of high-energy phosphorus metabolites are presented in human liver, heart, and transplanted and normal kidney.
journal_name
Radiologyjournal_title
Radiologyauthors
Matson GB,Twieg DB,Karczmar GS,Lawry TJ,Gober JR,Valenza M,Boska MD,Weiner MWdoi
10.1148/radiology.169.2.3051120subject
Has Abstractpub_date
1988-11-01 00:00:00pages
541-7issue
2eissn
0033-8419issn
1527-1315journal_volume
169pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.4001390
更新日期:1985-06-01 00:00:00
abstract:PURPOSE:To determine the appearance of normal hilar lymph nodes and associated soft tissue at spiral computed tomography (CT). MATERIALS AND METHODS:At spiral CT in 50 healthy patients, peribronchovascular hypoattenuated areas of 42 right and 45 left hila were systematically evaluated. Histologic results were correlat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.2.7617850
更新日期:1995-08-01 00:00:00
abstract:PURPOSE:To assess the repeatability in human volunteers of software-quantified small bowel motility captured with magnetic resonance (MR) imaging and to test the ability to detect changes in motility induced by pharmacologic agents. MATERIALS AND METHODS:The study was approved by the Royal Free Research Ethics Committ...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.13130151
更新日期:2013-11-01 00:00:00
abstract::A simple method of shielding the hand during cross-compression angiography is described. A standard lead glove with the fingertips cut out of the palmar aspect is used, allowing sensation and mobility while still protecting the hand. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.2.509
更新日期:1978-08-01 00:00:00
abstract::Absolute speeds (mR-1) of screen-film systems were determined accurately and precisely from ten independent measurements over a six month period at several beam qualities that included both scatter and scatter-free conditions. The absorbed x-ray energies in the screens that yielded a net film density of 1.0 were obtai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.1.6701320
更新日期:1984-04-01 00:00:00
abstract::Otosclerosis (otospongiosis) is a primary focal disease of the labyrinthine capsule. The stapes footplate is fixed when the spongiotic focus expands and invades the oval window. Persons with stapedial otosclerosis experience a progressive conductive hearing loss. In many cases, cochlear degeneration is observed, in wh...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.3.4023230
更新日期:1985-09-01 00:00:00
abstract::The incidental radiation dose of lithium fluoride thermoluminescence dosimeters was recorded during 15 treatments of patients with auricular keloids. Two half-value layers were used, and the results were compared. In both instances, the homolateral lens and thyroid received twice the contralateral dose. The oropharynx...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.3.7100490
更新日期:1982-08-01 00:00:00
abstract::Effective health care delivery systems rely heavily on high degrees of skill in professionalism and communication. These skills are essential to all of the missions of a successful radiology department. Until recently, there was a lack of emphasis on the importance of these issues and a lack of efforts in setting expe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2383041849
更新日期:2006-03-01 00:00:00
abstract:PURPOSE:To evaluate radiologists' performance for determining a distinction between benign and malignant pulmonary nodules on chest radiographs without and with use of a computer-aided diagnosis scheme. MATERIALS AND METHODS:Fifty-three chest radiographs that depicted 31 primary lung cancers and 22 benign nodules were...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2272020498
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions. MATERIALS AND METHODS:Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2381041336
更新日期:2006-02-01 00:00:00
abstract::To avoid the disadvantages associated with use of the traditional percutaneous transhepatic cholangiography (PTC) needle in ultrasonically guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma, the authors developed a needle with a three-sided tip and three holes within 3 mm of the tip. In ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.186.1.8416580
更新日期:1993-01-01 00:00:00
abstract::In the redistribution of cells through the division cycle between dose fractions, the sensitizing effect is greatest when small doses per fraction are used. Since nonproliferating tissues limit the dose in radiotherapy and will not be sensitized by redistribution, the more the dose is fractionated and the lower the do...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.1.199
更新日期:1975-01-01 00:00:00
abstract::This prospective study assesses the contribution of lymphography (LAG), abdominal-pelvic computed tomography (CT), and bone marrow biopsy to the staging and management of 168 consecutive cases of newly diagnosed non-Hodgkin lymphoma (NHL). LAG and/or CT influenced Ann Arbor clinical stage (CS) in 39 patients (23%) and...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.170.1.2909090
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:To perform a systematic review to evaluate the diagnostic accuracy of hepatobiliary (HPB) phase gadoxetic acid-enhanced MR imaging of the liver in the diagnosis of focal nodular hyperplasia (FNH) versus hepatocellular adenoma (HCA) and to identify the rate of (a) reported HCAs that are iso- or hyperintense to l...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2015142986
更新日期:2015-11-01 00:00:00
abstract::The authors identified the origin of a high-density artifact with mammography film. An acrylic ramp phantom (thickness, 0-7 cm) was used to create a continuously variable radiation exposure. A perturbation in the curve of optical density versus position along the ramp was observed. Development of the film with the emu...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.206.3.9494510
更新日期:1998-03-01 00:00:00
abstract::An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/119.1.79
更新日期:1976-04-01 00:00:00
abstract::Although intrauterine hydronephrosis can be detected readily by ultrasound, follow-up ultrasound evaluation on the first day of life may show a falsely normal-appearing kidney. The authors present three infants in whom subsequent studies confirmed the presence of upper urinary tract obstruction. It is postulated that ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.2.6539930
更新日期:1984-08-01 00:00:00
abstract::Embolization of metallic mercury is extremely rare. The literature has consisted primarily of scattered case reports. Two cases of patients with mercury embolization are presented. The differential diagnosis of the chest radiograph is discussed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.2.7433660
更新日期:1980-11-01 00:00:00
abstract:PURPOSE:To determine whether the Wallstent endoluminal prosthesis can be used to maintain patency of venous stenoses and occlusions related to hemodialysis access. MATERIALS AND METHODS:Wallstents were placed in 52 patients with 56 lesions. Thirty-two lesions were in central veins and 24 were in peripheral veins. Sten...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.195.2.7724770
更新日期:1995-05-01 00:00:00
abstract::A method to decrease the intensity of fat by reversal of the section-select gradient is demonstrated. This technique takes advantage of the chemical shift in section location. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.2.3393670
更新日期:1988-08-01 00:00:00
abstract::A diagnostic ultrasound examination is a simple and reliable method of obtaining anatomical information for intracavitary irradiation of endometrial carcinoma of the uterus. Scanning before treatment to determine uterine size and shape assists in choosing the most appropriate applicator. Scanning after insertion of an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/129.1.163
更新日期:1978-10-01 00:00:00
abstract::Four cases of severe skin reactions to the use of iocetamic acid as a contrast medium are reported. Although the incidence of this type of reaction was relatively small (1.8%), its severity induced the authors to discontinue the use of this medium. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.2.301
更新日期:1976-02-01 00:00:00
abstract:PURPOSE:To determine the reliability and efficacy of magnetic resonance (MR) cholangiography in demonstrating the site and extent of stricture. MATERIALS AND METHODS:In 40 patients with obstructive jaundice, three-dimensional MR cholangiography was performed with a sequence of mirrored fast imaging with steady-state p...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.2.8210370
更新日期:1993-11-01 00:00:00
abstract::To reduce radiation exposure to patients and staff during neurointerventional procedures, region-of-interest (ROI) techniques were used with fluoroscopy, road mapping, and digital subtraction angiography in 19 patients. ROI filters, made of multiple layers of gadolinium, were attached to the collimators. Patient skin ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.199.3.8638020
更新日期:1996-06-01 00:00:00
abstract:PURPOSE:To determine the characteristics and trends of the original articles published in two major American radiology journals, AJR American Journal of Roentgenology (AJR) and Radiology, between 2001 and 2010. MATERIALS AND METHODS:This was a retrospective bibliometric analysis that did not involve human subjects and...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12111976
更新日期:2012-09-01 00:00:00
abstract::The radiologic manifestations of Reiter disease in 56 patients are described. Although the findings are often nonspecific, certain features are distinctive, particularly when present in combination. These include subtle periosteal bone apposition at bony prominences, the infrequency of regional panarthritis and hip an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/132.1.1
更新日期:1979-07-01 00:00:00
abstract::An ex vivo magnetic resonance (MR) colonographic system with a bovine colon with polyps of predetermined dimensions was developed for evaluation and optimization of different combinations of imaging sequences and intraluminal contrast agents. Findings were then applied during in vivo testing in human subjects. The res...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2251011664
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2441052054
更新日期:2007-07-01 00:00:00
abstract::Bone scans using Tc-99m diphosphonate were found to become abnormal within 2 weeks after laminectomy in less than half of patients regardless of the extent of the operation. The degree of new uptake equaled that of the sacroiliac joints in only one of 19 patients with a normal preoperative scan. However, the Ga-67 cit...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.3.6585860
更新日期:1984-06-01 00:00:00
abstract::The authors adapted the transport system of a computed tomographic (CT) scanner with continuous rotation capability to examine complete lung subvolumes during a single breath hold. Twenty-four adult patients underwent scanning with up to 12 continuous 1-second rotations, and data acquisition was synchronized with long...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.3.2389050
更新日期:1990-09-01 00:00:00