Application of image-guided surface coil P-31 MR spectroscopy to human liver, heart, and kidney.

Abstract:

:Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface coil spectroscopy or rotating frame experiments, in which the extent of tissue sampled critically depends on surface coil placement. The authors' goal was to modify the surface coil image-selected in vivo spectroscopy (ISIS) experiment to accomplish three-dimensional volume selection through application of selective pulses in the presence of B0 gradients. Advantages of ISIS include the ability to use proton images to define the volume of interest (VOI) and reduced dependence on exact positioning of the surface coil. However, rapid replication of the surface coil ISIS experiment can cause spectral contamination from signals originating outside the VOI. A modified version of the ISIS experiment was developed to alleviate contamination under conditions of rapid replication. Applications of localized P-31 MR spectroscopy for observation of high-energy phosphorus metabolites are presented in human liver, heart, and transplanted and normal kidney.

journal_name

Radiology

journal_title

Radiology

authors

Matson GB,Twieg DB,Karczmar GS,Lawry TJ,Gober JR,Valenza M,Boska MD,Weiner MW

doi

10.1148/radiology.169.2.3051120

subject

Has Abstract

pub_date

1988-11-01 00:00:00

pages

541-7

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

169

pub_type

杂志文章
  • Retrievable vena caval filter percutaneously introduced.

    abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001390

    authors: Lund G,Rysavy J,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Hilar lymph nodes: identification with spiral CT and histologic correlation.

    abstract:PURPOSE:To determine the appearance of normal hilar lymph nodes and associated soft tissue at spiral computed tomography (CT). MATERIALS AND METHODS:At spiral CT in 50 healthy patients, peribronchovascular hypoattenuated areas of 42 right and 45 left hila were systematically evaluated. Histologic results were correlat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617850

    authors: Remy-Jardin M,Duyck P,Remy J,Petyt L,Wurtz A,Mensier E,Copin MC,Riquet M

    更新日期:1995-08-01 00:00:00

  • Global small bowel motility: assessment with dynamic MR imaging.

    abstract:PURPOSE:To assess the repeatability in human volunteers of software-quantified small bowel motility captured with magnetic resonance (MR) imaging and to test the ability to detect changes in motility induced by pharmacologic agents. MATERIALS AND METHODS:The study was approved by the Royal Free Research Ethics Committ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.13130151

    authors: Menys A,Taylor SA,Emmanuel A,Ahmed A,Plumb AA,Odille F,Alam A,Halligan S,Atkinson D

    更新日期:2013-11-01 00:00:00

  • Shielding the hand during cross-compression angiography.

    abstract::A simple method of shielding the hand during cross-compression angiography is described. A standard lead glove with the fingertips cut out of the palmar aspect is used, allowing sensation and mobility while still protecting the hand. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.2.509

    authors: Nusbacher N,Pollak L,Bryk D

    更新日期:1978-08-01 00:00:00

  • Absolute speeds of screen-film systems and their absorbed-energy constants.

    abstract::Absolute speeds (mR-1) of screen-film systems were determined accurately and precisely from ten independent measurements over a six month period at several beam qualities that included both scatter and scatter-free conditions. The absorbed x-ray energies in the screens that yielded a net film density of 1.0 were obtai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.1.6701320

    authors: Kodera Y,Doi K,Chan HP

    更新日期:1984-04-01 00:00:00

  • Use of CT in stapedial otosclerosis.

    abstract::Otosclerosis (otospongiosis) is a primary focal disease of the labyrinthine capsule. The stapes footplate is fixed when the spongiotic focus expands and invades the oval window. Persons with stapedial otosclerosis experience a progressive conductive hearing loss. In many cases, cochlear degeneration is observed, in wh...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.3.4023230

    authors: Mafee MF,Henrikson GC,Deitch RL,Norouzi P,Kumar A,Kriz R,Valvassori GE

    更新日期:1985-09-01 00:00:00

  • Dosimetry of auricular keloid irradiation.

    abstract::The incidental radiation dose of lithium fluoride thermoluminescence dosimeters was recorded during 15 treatments of patients with auricular keloids. Two half-value layers were used, and the results were compared. In both instances, the homolateral lens and thyroid received twice the contralateral dose. The oropharynx...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.3.7100490

    authors: Fitzgerald RH Jr,Tuten TU,Fenn JO

    更新日期:1982-08-01 00:00:00

  • Establishing a program to promote professionalism and effective communication in radiology.

    abstract::Effective health care delivery systems rely heavily on high degrees of skill in professionalism and communication. These skills are essential to all of the missions of a successful radiology department. Until recently, there was a lack of emphasis on the importance of these issues and a lack of efforts in setting expe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2383041849

    authors: Donnelly LF,Strife JL

    更新日期:2006-03-01 00:00:00

  • Computer-aided diagnosis to distinguish benign from malignant solitary pulmonary nodules on radiographs: ROC analysis of radiologists' performance--initial experience.

    abstract:PURPOSE:To evaluate radiologists' performance for determining a distinction between benign and malignant pulmonary nodules on chest radiographs without and with use of a computer-aided diagnosis scheme. MATERIALS AND METHODS:Fifty-three chest radiographs that depicted 31 primary lung cancers and 22 benign nodules were...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020498

    authors: Shiraishi J,Abe H,Engelmann R,Aoyama M,MacMahon H,Doi K

    更新日期:2003-05-01 00:00:00

  • Breast lesions: evaluation with US strain imaging--clinical experience of multiple observers.

    abstract:PURPOSE:To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions. MATERIALS AND METHODS:Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2381041336

    authors: Regner DM,Hesley GK,Hangiandreou NJ,Morton MJ,Nordland MR,Meixner DD,Hall TJ,Farrell MA,Mandrekar JN,Harmsen WS,Charboneau JW

    更新日期:2006-02-01 00:00:00

  • Development and evaluation of a needle for percutaneous ethanol injection therapy.

    abstract::To avoid the disadvantages associated with use of the traditional percutaneous transhepatic cholangiography (PTC) needle in ultrasonically guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma, the authors developed a needle with a three-sided tip and three holes within 3 mm of the tip. In ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.1.8416580

    authors: Akamatsu K,Miyauchi S,Ito Y,Ohkubo K,Maruyama M

    更新日期:1993-01-01 00:00:00

  • Cell cycle redistribution as a factor in multifraction irradiation.

    abstract::In the redistribution of cells through the division cycle between dose fractions, the sensitizing effect is greatest when small doses per fraction are used. Since nonproliferating tissues limit the dose in radiotherapy and will not be sensitized by redistribution, the more the dose is fractionated and the lower the do...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.1.199

    authors: Withers HR

    更新日期:1975-01-01 00:00:00

  • Non-Hodgkin lymphoma: influence of lymphography, CT, and bone marrow biopsy on staging and management.

    abstract::This prospective study assesses the contribution of lymphography (LAG), abdominal-pelvic computed tomography (CT), and bone marrow biopsy to the staging and management of 168 consecutive cases of newly diagnosed non-Hodgkin lymphoma (NHL). LAG and/or CT influenced Ann Arbor clinical stage (CS) in 39 patients (23%) and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2909090

    authors: Pond GD,Castellino RA,Horning S,Hoppe RT

    更新日期:1989-01-01 00:00:00

  • Focal Nodular Hyperplasia and Hepatocellular Adenoma: Accuracy of Gadoxetic Acid-enhanced MR Imaging--A Systematic Review.

    abstract:PURPOSE:To perform a systematic review to evaluate the diagnostic accuracy of hepatobiliary (HPB) phase gadoxetic acid-enhanced MR imaging of the liver in the diagnosis of focal nodular hyperplasia (FNH) versus hepatocellular adenoma (HCA) and to identify the rate of (a) reported HCAs that are iso- or hyperintense to l...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015142986

    authors: McInnes MD,Hibbert RM,Inácio JR,Schieda N

    更新日期:2015-11-01 00:00:00

  • Unusual artifact with mammography film.

    abstract::The authors identified the origin of a high-density artifact with mammography film. An acrylic ramp phantom (thickness, 0-7 cm) was used to create a continuously variable radiation exposure. A perturbation in the curve of optical density versus position along the ramp was observed. Development of the film with the emu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.3.9494510

    authors: Hedrick WR,Poulton TB,Starchman DE,Tobias TE

    更新日期:1998-03-01 00:00:00

  • The soleal line: a cause of tibial pseudoperiostitis.

    abstract::An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.1.79

    authors: Levine AH,Pais MJ,Berinson H,Amenta PS

    更新日期:1976-04-01 00:00:00

  • Postpartum evaluation of fetal hydronephrosis: optimal timing for follow-up sonography.

    abstract::Although intrauterine hydronephrosis can be detected readily by ultrasound, follow-up ultrasound evaluation on the first day of life may show a falsely normal-appearing kidney. The authors present three infants in whom subsequent studies confirmed the presence of upper urinary tract obstruction. It is postulated that ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6539930

    authors: Laing FC,Burke VD,Wing VW,Jeffrey RB Jr,Hashimoto B

    更新日期:1984-08-01 00:00:00

  • Intravenous self-administration of metallic mercury.

    abstract::Embolization of metallic mercury is extremely rare. The literature has consisted primarily of scattered case reports. Two cases of patients with mercury embolization are presented. The differential diagnosis of the chest radiograph is discussed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.2.7433660

    authors: Vas W,Tuttle RJ,Zylak CJ

    更新日期:1980-11-01 00:00:00

  • Use of Wallstents for hemodialysis access-related venous stenoses and occlusions untreatable with balloon angioplasty.

    abstract:PURPOSE:To determine whether the Wallstent endoluminal prosthesis can be used to maintain patency of venous stenoses and occlusions related to hemodialysis access. MATERIALS AND METHODS:Wallstents were placed in 52 patients with 56 lesions. Thirty-two lesions were in central veins and 24 were in peripheral veins. Sten...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.2.7724770

    authors: Gray RJ,Horton KM,Dolmatch BL,Rundback JH,Anaise D,Aquino AO,Currier CB,Light JA,Sasaki TM

    更新日期:1995-05-01 00:00:00

  • Fat suppression by section-select gradient reversal on spin-echo MR imaging. Work in progress.

    abstract::A method to decrease the intensity of fat by reversal of the section-select gradient is demonstrated. This technique takes advantage of the chemical shift in section location. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.2.3393670

    authors: Gomori JM,Holland GA,Grossman RI,Gefter WB,Lenkinski RE

    更新日期:1988-08-01 00:00:00

  • Use of ultrasonography in planning intracavitary radiotherapy of endometrial carcinoma.

    abstract::A diagnostic ultrasound examination is a simple and reliable method of obtaining anatomical information for intracavitary irradiation of endometrial carcinoma of the uterus. Scanning before treatment to determine uterine size and shape assists in choosing the most appropriate applicator. Scanning after insertion of an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.163

    authors: Brascho DJ,Kim RY,Wilson EE

    更新日期:1978-10-01 00:00:00

  • Skin reactions with iocetamic acid.

    abstract::Four cases of severe skin reactions to the use of iocetamic acid as a contrast medium are reported. Although the incidence of this type of reaction was relatively small (1.8%), its severity induced the authors to discontinue the use of this medium. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.301

    authors: Janower ML,Hannon MA

    更新日期:1976-02-01 00:00:00

  • MR cholangiography: clinical evaluation in 40 cases.

    abstract:PURPOSE:To determine the reliability and efficacy of magnetic resonance (MR) cholangiography in demonstrating the site and extent of stricture. MATERIALS AND METHODS:In 40 patients with obstructive jaundice, three-dimensional MR cholangiography was performed with a sequence of mirrored fast imaging with steady-state p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.2.8210370

    authors: Hall-Craggs MA,Allen CM,Owens CM,Theis BA,Donald JJ,Paley M,Wilkinson ID,Chong WK,Hatfield AR,Lees WR

    更新日期:1993-11-01 00:00:00

  • Application of region-of-interest imaging techniques to neurointerventional radiology.

    abstract::To reduce radiation exposure to patients and staff during neurointerventional procedures, region-of-interest (ROI) techniques were used with fluoroscopy, road mapping, and digital subtraction angiography in 19 patients. ROI filters, made of multiple layers of gadolinium, were attached to the collimators. Patient skin ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8638020

    authors: Rudin S,Guterman LR,Granger WE,Bednarek DR,Hopkins LN

    更新日期:1996-06-01 00:00:00

  • Characteristics and trends of radiology research: a survey of original articles published in AJR and Radiology between 2001 and 2010.

    abstract:PURPOSE:To determine the characteristics and trends of the original articles published in two major American radiology journals, AJR American Journal of Roentgenology (AJR) and Radiology, between 2001 and 2010. MATERIALS AND METHODS:This was a retrospective bibliometric analysis that did not involve human subjects and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12111976

    authors: Lim KJ,Yoon DY,Yun EJ,Seo YL,Baek S,Gu DH,Yoon SJ,Han A,Ku YJ,Kim SS

    更新日期:2012-09-01 00:00:00

  • Radiologic features of Reiter disease.

    abstract::The radiologic manifestations of Reiter disease in 56 patients are described. Although the findings are often nonspecific, certain features are distinctive, particularly when present in combination. These include subtle periosteal bone apposition at bony prominences, the infrequency of regional panarthritis and hip an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.1.1

    authors: Martel W,Braunstein EM,Borlaza G,Good AE,Griffin PE Jr

    更新日期:1979-07-01 00:00:00

  • MR colonography: development of optimized method with ex vivo and in vivo systems.

    abstract::An ex vivo magnetic resonance (MR) colonographic system with a bovine colon with polyps of predetermined dimensions was developed for evaluation and optimization of different combinations of imaging sequences and intraluminal contrast agents. Findings were then applied during in vivo testing in human subjects. The res...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251011664

    authors: Martin DR,Yang M,Thomasson D,Acheson C

    更新日期:2002-11-01 00:00:00

  • Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

    abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2441052054

    authors: Brace CL,Laeseke PF,Sampson LA,Frey TM,van der Weide DW,Lee FT Jr

    更新日期:2007-07-01 00:00:00

  • Laminectomy: effects on postoperative technetium and gallium scintigraphy.

    abstract::Bone scans using Tc-99m diphosphonate were found to become abnormal within 2 weeks after laminectomy in less than half of patients regardless of the extent of the operation. The degree of new uptake equaled that of the sacroiliac joints in only one of 19 patients with a normal preoperative scan. However, the Ga-67 cit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.3.6585860

    authors: Silberstein EB,Schneider HJ,Khodadad G,DeVries D,Rauf GC,Noll R

    更新日期:1984-06-01 00:00:00

  • Lung: spiral volumetric CT with single-breath-hold technique.

    abstract::The authors adapted the transport system of a computed tomographic (CT) scanner with continuous rotation capability to examine complete lung subvolumes during a single breath hold. Twenty-four adult patients underwent scanning with up to 12 continuous 1-second rotations, and data acquisition was synchronized with long...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.3.2389050

    authors: Vock P,Soucek M,Daepp M,Kalender WA