Dentate Nucleus Signal Intensity Increases Following Repeated Gadobenate Dimeglumine Administrations: A Retrospective Analysis.

Abstract:

:Background Increased cerebral signal intensity (SI) has been reported in patients undergoing MRI with gadolinium-based contrast agents (GBCAs). Published data on gadobenate dimeglumine have been somewhat contradictory. Purpose To evaluate the relationship between dosage of gadobenate dimeglumine and SI change at MRI following multiple gadobenate dimeglumine administrations. Materials and Methods In this retrospective study, patients referred for clinically indicated brain MRI from January 2006 through May 2016 were evaluated for inclusion. Eligible patients were between 18 and 90 years old at their baseline brain MRI and had never received a GBCA, had undergone three or more MRI examinations with gadobenate dimeglumine, and had the baseline scan and another brain MRI scan available for comparison. The primary group consisted of patients with four or fewer supratentorial lesions smaller than 3 cm who underwent axial T1-weighted MRI at 1.5 T. One patient had also undergone prior radiation therapy. The secondary group consisted of patients with a history of brain radiation therapy or craniotomy who underwent 1.5-T and 3-T same-plane T1-weighted MRI (in any order). The SI for up to eight brain MRI examinations per patient was measured, and relative SI changes from baseline to interval scans were calculated. A subgroup analysis was performed to assess the gadobenate dimeglumine washout since the last gadolinium exposure. All patients had normal renal and liver functions. Linear mixed regression analyses were performed for variables with P < .05. Results In 43 patients (14 men, 29 women; median age, 49 years; age range, 25-73 years), the dentate nucleus (DN)-to-middle cerebral peduncle (MCP) SI ratio showed a mean increase of 6.7% ± 3.9 in the primary group and 4.0% ± 2.7 in the secondary group (both P < .001) following the administration of 134 mL ± 141 gadobenate dimeglumine over 55 months ± 35.2. The DN/MCP SI ratio increased linearly with the amount of gadobenate dimeglumine, with a mean increase of 0.015% ± 0.004 per 1 mL of gadobenate dimeglumine (R2 = 0.3, P < .001). Conclusion In patients receiving multiple doses of gadobenate dimeglumine, a linear relationship existed between gadobenate dimeglumine administrations and an increase in the dentate nucleus-to-middle cerebral peduncle signal intensity ratio at MRI. © RSNA, 2020 See also the editorial by McDonald and Kallmes in this issue.

journal_name

Radiology

journal_title

Radiology

authors

Nguyen NC,Molnar TT,Cummin LG,Kanal E

doi

10.1148/radiol.2020190246

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

122-130

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

296

pub_type

杂志文章
  • Salivary gland tumors: evaluation with two-phase helical CT.

    abstract:PURPOSE:To evaluate two-phase helical computed tomography (CT) in the characterization of salivary gland tumors. MATERIALS AND METHODS:Sixty-four patients with major salivary gland tumors underwent two-phase helical CT. The histopathologic diagnosis was obtained by means of surgical resection or biopsy in all patients...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.1.r00ja05231

    authors: Choi DS,Na DG,Byun HS,Ko YH,Kim CK,Cho JM,Lee HK

    更新日期:2000-01-01 00:00:00

  • Coronary sinus flow measurement by means of velocity-encoded cine MR imaging: validation by using flow probes in dogs.

    abstract:PURPOSE:To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS:Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at ba...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.2.r00nv10487

    authors: Lund GK,Wendland MF,Shimakawa A,Arheden H,Ståhlberg F,Higgins CB,Saeed M

    更新日期:2000-11-01 00:00:00

  • Vertebral-body collapse in focal and diffuse disease: patterns of pathologic processes.

    abstract::The radiographic patterns of vertebral-body collapse and/or endplate deformity were examined in 99 autopsy specimens of the thoracolumbar spine with benign and malignant disease. Angling of endplates was found to be highly predictive of underlying malignancy, whereas concavity was more suggestive of benign disease, fo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.2.3726130

    authors: Sartoris DJ,Clopton P,Nemcek A,Dowd C,Resnick D

    更新日期:1986-08-01 00:00:00

  • Computed transaxial imaging using single gamma emitters.

    abstract::Emission computed tomography (ECT) studies were performed on test objects and dogs. Conjugate views were obtained for 60 to 120 projections equispaced around 360 degrees by rotation of the subjects in front of a gamma camera. A convolution reconstruction algorithm in which gamma ray attenuation corrections are include...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.187

    authors: Gustafson DE,Berggren MJ,Singh M,Dewanjee MK

    更新日期:1978-10-01 00:00:00

  • Skeletal metastases from hepatoma: frequency, distribution, and radiographic features.

    abstract::Over the past 6 years, the authors evaluated 300 patients with hepatoma as part of phase 1 and 2 treatment protocol trials. Analysis of the available clinical data and radiographic studies revealed 22 patients (7.3%) with skeletal metastases demonstrated by radiography, computed tomography (CT), and/or nuclear scintig...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.1.3012630

    authors: Kuhlman JE,Fishman EK,Leichner PK,Magid D,Order SE,Siegelman SS

    更新日期:1986-07-01 00:00:00

  • Bronchopulmonary sequestration: CT assessment.

    abstract::Computed tomographic (CT) scans of 24 bronchopulmonary sequestrations in 23 patients were reviewed. Seventeen sequestrations were diagnosed at surgery, three at angiography, and four on the basis of radiographic or CT findings combined with appropriate history. Sixteen sequestrations were intralobar, and eight were ex...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.2.2367650

    authors: Ikezoe J,Murayama S,Godwin JD,Done SL,Verschakelen JA

    更新日期:1990-08-01 00:00:00

  • Exogenous lung surfactant: effect on radiographic appearance in premature infants.

    abstract::At birth, premature infants of 25-29 weeks gestation, at high risk for development of neonatal respiratory distress syndrome (RDS), were given a single dose (90 mg) of calf lung surfactant extract (CLSE) by intratracheal instillation. The frequency and severity of RDS were assessed with use of a simple radiographic sc...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.165.1.3306780

    authors: Wood BP,Sinkin RA,Kendig JW,Notter RH,Shapiro DL

    更新日期:1987-10-01 00:00:00

  • The accordion sign at CT: a nonspecific finding in patients with colonic edema.

    abstract:PURPOSE:To determine whether the "accordion sign" is a specific computed tomographic (CT) sign of Clostridium difficile colitis. MATERIALS AND METHODS:Fifty-seven patients with CT evidence of severe colitis, as judged by colonic wall thickening, an abnormal haustral pattern, the target sign, and stranding of the peric...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.3.r99jn32743

    authors: Macari M,Balthazar EJ,Megibow AJ

    更新日期:1999-06-01 00:00:00

  • Rupture of the posterior tibial tendon: CT and surgical findings.

    abstract::Computed tomography (CT) was performed in 42 patients with 49 clinically suspected tears of the posterior tibial tendon. Twenty-eight of the 49 suspected tears were subsequently surgically explored and repaired. Three patterns of tendon abnormalities were recognized on CT scans: type I-intact, hypertrophied, heterogen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.2.3357960

    authors: Rosenberg ZS,Jahss MH,Noto AM,Shereff MJ,Cheung Y,Frey CC,Norman A

    更新日期:1988-05-01 00:00:00

  • Duplication of the müllerian ducts and genitourinary malformations. Part II: analysis of malformations.

    abstract::Forty-seven females with duplication of the uterus and cervix were retrospectively studied to obtain a better understanding of the reasons for failure of fusion of the müllerian ducts by analyzing the associated genitourinary malformations. Thirty-one of the 47 patients had major genitourinary malformations that corre...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.4.6213980

    authors: Gilsanz V,Cleveland RH,Reid BS

    更新日期:1982-09-01 00:00:00

  • Hyperacute thermal lesions: MR imaging evaluation of development in the brain.

    abstract:PURPOSE:To determine the natural time course of development of hyperacute thermal lesions in the brain. MATERIALS AND METHODS:Ten interstitial lesions were created in five rabbit brains with a radio-frequency probe; an electrode-tip temperature of 80 degrees C was maintained for 60 seconds. Continuous fast spin-echo m...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617870

    authors: Farahani K,Mischel PS,Black KL,De Salles AA,Anzai Y,Lufkin RB

    更新日期:1995-08-01 00:00:00

  • Predicting pathologic response to neoadjuvant chemotherapy in breast cancer by using MR imaging and quantitative 1H MR spectroscopy.

    abstract:PURPOSE:To compare changes in the concentration of choline-containing compounds (tCho) and in tumor size at follow-up after neoadjuvant chemotherapy (NAC) between patients who achieved pathologic complete response (pCR) and those who did not (non-pCR). MATERIALS AND METHODS:This study was approved by the institutional...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2512080553

    authors: Baek HM,Chen JH,Nie K,Yu HJ,Bahri S,Mehta RS,Nalcioglu O,Su MY

    更新日期:2009-06-01 00:00:00

  • Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.

    abstract:PURPOSE:To analyze the effect of a decrease in computed tomographic (CT) colonographic voltage, from 100 and 120 kVp to 80 kVp and reconstructed with filtered back projection ( FBP filtered back projection ), on radiation dose, image noise, and diagnostic performance in anthropomorphic phantoms and to assess the effect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140192

    authors: Shin CI,Kim SH,Lee ES,Lee DH,Hwang EJ,Chung SY,Lee JM,Han JK,Choi BI

    更新日期:2014-12-01 00:00:00

  • Radiologic distinction of pyogenic pulmonary infection from Pneumocystis carinii pneumonia in AIDS patients.

    abstract::Thirty-four episodes of pyogenic pulmonary infection in 30 patients infected with human immunodeficiency virus (HIV) and 30 episodes of Pneumocystis carinii pneumonia (PCP) in 30 AIDS patients were reviewed to determine if the radiologic features were more helpful than clinical and laboratory findings in the different...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.3.2343120

    authors: Amorosa JK,Nahass RG,Nosher JL,Gocke DJ

    更新日期:1990-06-01 00:00:00

  • The QIBA Profile for FDG PET/CT as an Imaging Biomarker Measuring Response to Cancer Therapy.

    abstract::The Quantitative Imaging Biomarkers Alliance (QIBA) Profile for fluorodeoxyglucose (FDG) PET/CT imaging was created by QIBA to both characterize and reduce the variability of standardized uptake values (SUVs). The Profile provides two complementary claims on the precision of SUV measurements. First, tumor glycolytic a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019191882

    authors: Kinahan PE,Perlman ES,Sunderland JJ,Subramaniam R,Wollenweber SD,Turkington TG,Lodge MA,Boellaard R,Obuchowski NA,Wahl RL

    更新日期:2020-03-01 00:00:00

  • White Matter by Diffusion MRI Following Methylphenidate Treatment: A Randomized Control Trial in Males with Attention-Deficit/Hyperactivity Disorder.

    abstract::BackgroundMethylphenidate (MPH) is highly effective in treating attention-deficit/hyperactivity disorder (ADHD). However, not much is known about its effect on the development of human brain white matter (WM).PurposeTo determine whether MPH modulates WM microstructure in an age-dependent fashion in a randomized double...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2019182528

    authors: Bouziane C,Filatova OG,Schrantee A,Caan MWA,Vos FM,Reneman L

    更新日期:2019-10-01 00:00:00

  • Thyroid imaging with high-field-strength surface-coil MR.

    abstract::Magnetic resonance (MR) imaging of the thyroid was performed with a 1.5-T system and local receiver coil in 19 "healthy" subjects and 34 patients with various focal and diffuse thyroid disorders. The normal gland was typically homogeneous with increased intensity relative to that of muscle on images obtained with long...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3602390

    authors: Gefter WB,Spritzer CE,Eisenberg B,LiVolsi VA,Axel L,Velchik M,Alavi A,Schenck J,Kressel HY

    更新日期:1987-08-01 00:00:00

  • Spinal subdural hematoma.

    abstract::The authors report a case of subacute spinal subdural hematoma in a patient with ankylosing spondylitis. Only 18 such cases have been reported in the nonradiological literature. Early diagnosis is imperative in order to minimize neurological sequelae. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.1.116

    authors: Sokoloff J,Coel MN,Ignelzi RJ

    更新日期:1976-07-01 00:00:00

  • Systemic-to-pulmonary collateral vessels and shunts: treatment with embolization.

    abstract::Abnormal collateral vessels develop frequently in patients with right ventricular outflow or pulmonary artery obstruction. Surgery is usually used to obliterate these vessels but may be difficult, involve prolonged operative time, or require a different thoracotomy than that used for correction or palliation of the ca...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.3186990

    authors: Lois JF,Gomes AS,Smith DC,Laks H

    更新日期:1988-12-01 00:00:00

  • Postbiopsy bleeding in a porcine model: reduction with radio-frequency ablation--preliminary results.

    abstract:PURPOSE:To test a biopsy needle modified for use of radio-frequency (RF) energy to produce hemostasis after core biopsy of liver or kidney. MATERIALS AND METHODS:RF energy was applied to a partially insulated 17-gauge needle, and tip temperature was monitored with a thermocouple. Domestic Yorkshire pigs (n = 4; mean w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020173

    authors: Laeseke PF,Winter TC 3rd,Davis CL,Stevens KR,Johnson CD,Fronczak FJ,Webster JG,Lee FT Jr

    更新日期:2003-05-01 00:00:00

  • Distinguishing adrenal adenomas from nonadenomas: combined use of diagnostic parameters of unenhanced and short 5-minute dynamic enhanced CT protocol.

    abstract:PURPOSE:To retrospectively examine the diagnostic values of individual parameters obtained from unenhanced and 35-second and 5-minute contrast material-enhanced (enhanced) computed tomography (CT) in distinguishing adenomas, particularly lipid-poor adenomas, from nonadenomas and to determine the best diagnostic method ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2502080302

    authors: Kamiyama T,Fukukura Y,Yoneyama T,Takumi K,Nakajo M

    更新日期:2009-02-01 00:00:00

  • The cathartic colon: pathological findings and radiological/pathological correlation.

    abstract::Cathartic colon has been described radiologically, but the pathological characteristics have not been reported. The authors describe a case in which radiological/pathological correlation was possible, with emphasis on the pathology of the colon. The disease simulates chronic ulcerative colitis radiologically and patho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.3.557

    authors: Urso FP,Urso MJ,Lee CH

    更新日期:1975-09-01 00:00:00

  • Comparison of CT, low-field-strength MR imaging, and high-field-strength MR imaging. Work in progress.

    abstract::To assess objectively the sensitivity and specificity of low-field-strength (0.064 T) magnetic resonance (MR) imaging, a prospective blind study of 280 examinations was performed to compare low-field-strength MR imaging with computed tomography (CT) and with high-field-strength (1.5-T) MR imaging of the cranium. The s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.181.1.1887020

    authors: Orrison WW Jr,Stimac GK,Stevens EA,LaMasters DL,Espinosa MC,Cobb L,Mettler FA Jr

    更新日期:1991-10-01 00:00:00

  • Clearance of Gadolinium from the Brain with No Pathologic Effect after Repeated Administration of Gadodiamide in Healthy Rats: An Analytical and Histologic Study.

    abstract::Purpose To measure the levels of gadolinium present in the rat brain 1 and 20 weeks after dosing with contrast agent and to determine if there are any histopathologic sequelae. Materials and Methods The study was approved by the GE Global Research Center Institutional Animal Care and Use Committee. Absolute gadolinium...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160905

    authors: Smith AP,Marino M,Roberts J,Crowder JM,Castle J,Lowery L,Morton C,Hibberd MG,Evans PM

    更新日期:2017-03-01 00:00:00

  • Degeneration of the ipsilateral substantia nigra after striatal infarction: evaluation with MR imaging.

    abstract:PURPOSE:To evaluate the degeneration of the ipsilateral substantia nigra after striatal infarction by using magnetic resonance (MR) imaging. MATERIALS AND METHODS:Twenty-five adult patients with embolic cerebral infarction of the middle cerebral artery distribution underwent MR imaging 0-4, 5-9, 12-15, and 27-29 days ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.3.9280270

    authors: Ogawa T,Okudera T,Inugami A,Noguchi K,Kado H,Yoshida Y,Uemura K

    更新日期:1997-09-01 00:00:00

  • Mapping T2 relaxation time in the pediatric knee: feasibility with a clinical 1.5-T MR imaging system.

    abstract:PURPOSE:To determine the feasibility of mapping the spatial variation of cartilage T2 relaxation time in vivo in the pediatric knee with a 1.5-T clinical magnetic resonance (MR) imaging system and the manufacturer's body gradient coil. MATERIALS AND METHODS:Twenty-five children and adolescents (age range, 5-17 years; ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251011461

    authors: Dardzinski BJ,Laor T,Schmithorst VJ,Klosterman L,Graham TB

    更新日期:2002-10-01 00:00:00

  • Radiologic evaluation of the intravenous oxygenator.

    abstract::This report describes the radiologic appearance of the intravenous oxygenator (IVOX), an intracorporeal CO2-O2 exchanger for use in patients with severe respiratory deficiency, and the extensive radiographic and sonographic support required for its use. Six patients aged 19-39 years who had severe adult respiratory di...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1148/radiology.187.3.8497630

    authors: Shukla PR,Snider MT,Hopper KD,Thieme GA,Meilstrup JW

    更新日期:1993-06-01 00:00:00

  • Childhood leukemia: diagnostic accuracy of bedside chest radiography for severe pulmonary complications.

    abstract:PURPOSE:To determine the diagnostic accuracy of bedside chest radiography in patients who develop severe pulmonary complications while undergoing therapy for leukemia. MATERIALS AND METHODS:The authors studied 45 patients, aged 21 years and younger, who died of leukemia or of treatment complications and for whom autop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.1.8090880

    authors: Winer-Muram HT,Rubin SA,Fletcher BD,Kauffman WM,Jennings SG,Arheart KL,Bozeman PM

    更新日期:1994-10-01 00:00:00

  • Contrast-enhanced MR angiography of peripheral arteries including pedal vessels at 1.0 T: feasibility study with dedicated peripheral angiography coil.

    abstract:PURPOSE:To prospectively determine feasibility of contrast material-enhanced magnetic resonance (MR) angiography of the peripheral arteries from distal aorta to pedal arteries with a 1.0-T system and a dedicated phased-array coil. MATERIALS AND METHODS:Twenty-seven patients with peripheral arteriosclerotic occlusive d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2351031987

    authors: Janka R,Fellner C,Wenkel E,Lang W,Bautz W,Fellner FA

    更新日期:2005-04-01 00:00:00

  • The origin of the left gastric artery.

    abstract::Five hundred celiac angiograms were reviewed to evaluate the frequency of clinically significant variations in the origin of the left gastric artery. In 13 of 500 cases, the left gastric artery arose anomalously most often as a direct branch of the aorta; in 14 of 500 cases, the left gastric artery primarily supplied ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/126.3.623

    authors: Naidich JB,Naidich TP,Sprayregen S,Hyman RA,Pudlowski RM,Stein HL

    更新日期:1978-03-01 00:00:00