Abstract:
:Fine needle, percutaneous aspiration of suspect lymph nodes was carried out in 29 patients during fluoroscopy. The correct positioning of the needle was assured if the node moved with the tip of the needle. In 29 patients, there were 65 successful aspirations and 29 failures. Anesthesia is recommended but care should be taken that the anesthetic does not reach the lymph node itself as this can cause distortion of the cells.
journal_name
Radiologyjournal_title
Radiologyauthors
Göthlin JHdoi
10.1148/120.1.205subject
Has Abstractpub_date
1976-07-01 00:00:00pages
205-7issue
1eissn
0033-8419issn
1527-1315journal_volume
120pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Twelve patients with symptoms of acute cholecystitis underwent heavily T2-weighted and mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography and cholescintigraphy before they underwent cholecystectomy. On T2-weighted MR cholangiographic images, morphologic evidence of outflow obstruction ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2272020207
更新日期:2003-05-01 00:00:00
abstract::Successful balloon catheter dilatation through the defunctionalized limb of a colostomy was performed in three infants with postischemic colonic stricture. This experience suggests that balloon catheter dilatation can be an alternative to surgical resection in treating delayed ischemic colonic stricture. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.2.6622690
更新日期:1983-11-01 00:00:00
abstract::In a series of nine stereotaxic large-core biopsies of calcifications, radiography of the specimen was used to ensure that appropriate tissue was removed. In eight cases, calcifications were evident at radiography as well as at histologic evaluation. Four cases were malignant and four were benign, and in one case in w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.2.8327720
更新日期:1993-08-01 00:00:00
abstract::A device was developed for hysterosalpingography and fallopian tube recanalization. It differs from the previously used vacuum-cup device in that the central shaft slides and has an acorn-shaped tip. Optimal results were obtained in all 14 women (100%) who underwent catheterization with the new device; optimal results...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.2.2296670
更新日期:1990-02-01 00:00:00
abstract:PURPOSE:To evaluate ultrasonographic (US) features in the differential diagnosis of giant gastric folds. MATERIALS AND METHODS:One hundred sixty-five patients with giant gastric folds at transabdominal US examination (five with Ménétrier disease, 24 with anisakiasis, 61 with acute gastric mucosal lesion [AGML], 13 wit...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2263012080
更新日期:2003-03-01 00:00:00
abstract::Ultrasound guidance was used in 10 aspiration and six drainage procedures in the intensive care unit. Sonography offered a safe and effective method for guidance of diagnostic aspiration in the ICU setting. Additionally, cholecystostomy, nephrostomy, abscess drainage, and empyema drainage were performed at bedside as ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966140
更新日期:1985-02-01 00:00:00
abstract::Measurements of the intensity distribution of a 60-Co beam revealed a significant field distortion caused by minor misalignment of the collimator assembly which was not detected by routine methods. Accurate monitoring of radiation intensity distribution and periodic visual inspection of collimators are suggested for ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.1.226
更新日期:1975-07-01 00:00:00
abstract:PURPOSE:To identify mechanism(s) responsible for carpal tunnel syndrome (CTS). MATERIALS AND METHODS:At dynamic gadolinium-enhanced magnetic resonance (MR) imaging, the enhancement pattern of the sagittal section of the median nerve in 10 wrists of nine patients with CTS (two men and seven women, aged 43-60 years [mea...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.190.2.8284400
更新日期:1994-02-01 00:00:00
abstract::An overview of current air-contrast stomach examination techniques is offered: (a) Hampton's technique which does not use distension; (b) the Japanese method which utilizes the relaxant drug Buscopan, good distension, and much patient rotation; (c) a third method in which no drugs are used but more distension is obtai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/117.3.743
更新日期:1975-12-01 00:00:00
abstract::Adenomatous hyperplastic nodules (AHNs) in the cirrhotic liver may be precurosors of hepatocellular carcinoma. These nodules have been demonstrated more frequently because of the increased use of ultrasonography (US) in the screening of high-risk patients. Treatment is a problem because surgical resection of a precanc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.170.1.2642340
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population. MATERIALS AND METHODS:Fifty breast cancers detected at screening were analyzed by using a commercially availabl...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2332031200
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:To assess the detection of prostate cancer with contrast material-enhanced transrectal sonography. MATERIALS AND METHODS:Sixty subjects were examined with conventional gray-scale, harmonic gray-scale, and power Doppler sonography. Evaluation was repeated during intravenous infusion of contrast agent. Gray-scal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.219.1.r01ap21219
更新日期:2001-04-01 00:00:00
abstract::Five hundred celiac angiograms were reviewed to evaluate the frequency of clinically significant variations in the origin of the left gastric artery. In 13 of 500 cases, the left gastric artery arose anomalously most often as a direct branch of the aorta; in 14 of 500 cases, the left gastric artery primarily supplied ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.3.623
更新日期:1978-03-01 00:00:00
abstract::This description of procedures in two patients illustrates successful thoracic needle biopsy, despite the fact that the lesion was obscured by overlapping bones in each instance. The technique of screwing a 20-gauge needle through the overlapping bone is suggested as an innovative method when more traditional approach...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.1.2399330
更新日期:1990-10-01 00:00:00
abstract::The effectiveness of three methods of assessing the patient body burden following 131I therapy was compared: (a) urine assay, (b) external exposure rate measurements, and (c) predictions based on a pretherapy diagnostic work-up. The urine assay method exhibited the greatest potential for error and personnel risk. The ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.3.7444070
更新日期:1980-12-01 00:00:00
abstract:PURPOSE:To assess whether a combination of in vivo anatomic and functional imaging can help quantify expression of somatostatin receptor type 2 (SSTR2)-based reporters after in vivo gene transfer. MATERIALS AND METHODS:All animal experiments were approved by an institutional animal care and use committee. Six nude mic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2531081825
更新日期:2009-09-01 00:00:00
abstract::Purpose To demonstrate that anti-MG1 conjugated hybrid magnetic gold nanoparticles (HNPs) act as a catalyst during photothermal ablation (PTA) of colorectal liver metastases, and thus increase ablation zones. Materials and Methods All experiments were performed with approval of the institutional animal care and use co...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161497
更新日期:2017-12-01 00:00:00
abstract::The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent car...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2331031564
更新日期:2004-10-01 00:00:00
abstract::Duplex and color Doppler ultrasound (US) are noninvasive techniques capable of providing much information about the condition of blood vessels and flow within them throughout the body. Doppler US provides more than noninvasive angiography. Besides assessment of blood vessel patency and direction of flow, analysis of t...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiology.174.2.2404310
更新日期:1990-02-01 00:00:00
abstract::Although magnetic resonance (MR) imaging has been used to evaluate many musculoskeletal lesions, the MR appearance of pigmented villonodular synovitis (PVNS) has not been described in detail. The authors describe two cases of PVNS in the knee imaged with both computed tomography and MR. In both cases parts of each les...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.2.3562840
更新日期:1987-05-01 00:00:00
abstract::The rates of diabetes, obesity, and metabolic disease have reached epidemic proportions worldwide. In recent years there has been renewed interest in combating these diseases not only by modifying energy intake and lifestyle factors, but also by inducing endogenous energy expenditure. This approach has largely been st...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2016150390
更新日期:2016-07-01 00:00:00
abstract::The transjugular intrahepatic portosystemic shunt procedure is an effective intervention for patients with bleeding esophageal varices. Potential complications are numerous but rarely serious. A case of hemopericardium, cardiac tamponade, and death caused by perforation of the right atrium and aorta by a stent after e...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.205.1.9314980
更新日期:1997-10-01 00:00:00
abstract::A Kimray-Greenfield filter was inadvertently placed in the right atrium of a patient with multiple pulmonary emboli. A percutaneous technique with the use of a chest tube and basket catheter was performed to retrieve and remove the filter. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.167.2.3357950
更新日期:1988-05-01 00:00:00
abstract::Two patients with cystic fibrosis and pancreatic cystosis are described who had complete replacement of the pancreas by multiple macroscopic cysts. The possible causes and clinical significance of this condition are discussed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.3.3511500
更新日期:1986-03-01 00:00:00
abstract:PURPOSE:To determine whether dynamic ultrasonography (US) can reveal abnormalities of the anterior band of the ulnar collateral ligament (UCL) of the elbow in asymptomatic major league professional baseball players. MATERIALS AND METHODS:US was performed in 26 asymptomatic major league professional baseball pitchers b...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2271020288
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:To evaluate efficacy and safety of a hydrodynamic rheolytic thrombectomy device for rapid percutaneous treatment of acute thromboembolic occlusions of native lower-extremity arteries and bypass grafts. MATERIALS AND METHODS:In 50 patients, thrombectomy was performed with the rheolytic catheter at four centers....
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1148/radiology.205.3.9393520
更新日期:1997-12-01 00:00:00
abstract:PURPOSE:A prospective study was performed to compare the sensitivity and specificity of magnetic resonance (MR) imaging and computed tomography (CT) both performed during arterial portography in depicting focal hepatic masses. MATERIALS AND METHODS:Eleven patients with 31 pathologically proved focal hepatic masses wer...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.190.3.8115620
更新日期:1994-03-01 00:00:00
abstract::A formalin-fixed cadaver head with air filling the cisternal and ventricular spaces was scanned by high-resolution computed tomography (CT) in multiple planes (axial, coronal, and sagittal) through the Meckel cave. Correlation of the CT appearance of the Meckel cave was made with an anatomic dissection and whole-head ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.2.6739810
更新日期:1984-08-01 00:00:00
abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020192723
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To test, by using an electrotransfer protocol for the transfection of skeletal muscle with naked plasmid complementary DNA, whether in vivo magnetic resonance (MR) imaging can help delineate either the spatial extent of the electric field when contrast agent is injected intraperitoneally or the transfection are...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2283020482
更新日期:2003-09-01 00:00:00