Abstract:
PURPOSE:To assess the benefit of adding diffusion-weighted (DW) imaging to gadoxetic acid-enhanced magnetic resonance (MR) imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma. MATERIALS AND METHODS:The institutional review board approved this retrospective study and waived the requirement for informed consent. The study included 52 patients (36 men, 16 women; mean age, 63.4 years) with surgically confirmed hilar cholangiocarcinoma who underwent gadoxetic acid-enhanced MR imaging and DW imaging at 3.0 T between August 2010 and December 2011. Two observers independently reviewed two image sets--a gadoxetic acid set, including images from MR cholangiopancreatography, and a combined gadoxetic acid set and DW imaging set--to evaluate the tumor involvement of each biliary confluence and vascular and liver invasion by using receiver operating characteristic (ROC) curve analysis. RESULTS:For each observer, area under the ROC curve (Az) values for tumor involvement of the biliary confluence were 0.965 and 0.957 for the gadoxetic acid set and 0.980 and 0.975 for the combined set, respectively (P > .05). For detecting 105 biliary confluences with tumor involvement, the sensitivities with the combined set (97.1% [102 of 105] and 98.1% [103 of 105]) were higher than those with the gadoxetic acid set (91.4% [96 of 105] for both observers) (P = .029 and P = .016), although the specificities were similar with both image sets (P > .05). For the detection of liver invasion, the combined set (75.0% [15 of 20] for both observers) yielded better sensitivity than the gadoxetic acid set (50.0% [10 of 20] and 45.0% [nine of 20]) (P = .016 and P = .031). For evaluation of vascular invasion, the two image sets showed similar diagnostic performance. CONCLUSION:In the preoperative evaluation of hilar cholangiocarcinoma, the addition of DW imaging to gadoxetic acid-enhanced MR imaging could improve sensitivity in the evaluation of tumor extent along the bile duct and liver invasion.
journal_name
Radiologyjournal_title
Radiologyauthors
Park MJ,Kim YK,Lim S,Rhim H,Lee WJdoi
10.1148/radiol.13130009subject
Has Abstractpub_date
2014-03-01 00:00:00pages
768-76issue
3eissn
0033-8419issn
1527-1315journal_volume
270pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.3.1584940
更新日期:1992-06-01 00:00:00
abstract:PURPOSE:To compare areas of contrast material enhancement in the prostate at ultrasonography (US) with whole-mount radical prostatectomy specimens to determine if the use of contrast material improves the detection rate of prostate cancer. MATERIALS AND METHODS:Transrectal US was performed in 12 subjects with cancer o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2222010582
更新日期:2002-02-01 00:00:00
abstract::The relationship of the brain angiographic mode circulation time (AVCT) to the mean transit time of the vascular indicator C15O-labeled hemoglobin (tc15o) and the regional cerebral blood flow (rCBF) as measured by the clearance of the diffusible tracer H2-15O was examined in 38 patients with selected cerebral diseases...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/115.1.107
更新日期:1975-04-01 00:00:00
abstract::Many physico-anatomic variables and instrument parameters influence the relative magnetic resonance signal intensity of vascular channels. The interaction of these mechanisms is complex, but their composite effects can be accounted for by two main categories of flow phenomena: time-of-flight effects and spin-phase cha...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.3.3786730
更新日期:1986-12-01 00:00:00
abstract::Purpose To identify risk factors for hippocampal calcifications and to investigate the association between hippocampal calcifications and cognitive function. Materials and Methods For this retrospective study, consecutive patients visiting a memory clinic at a Dutch general hospital between April 2009 and April 2015 w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018172588
更新日期:2018-09-01 00:00:00
abstract:PURPOSE:To determine the incidence of a "stuck" disk and its importance in the overall scheme of internal derangement. MATERIALS AND METHODS:Magnetic resonance (MR) images of 212 temporomandibular joints (TMJs) in 106 symptomatic patients were obtained and reviewed. Image analysis included assessment of disk position;...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.3.8234710
更新日期:1993-12-01 00:00:00
abstract:PURPOSE:To determine the feasibility and safety of ultrasonographically (US) guided percutaneous radiofrequency (RF) ablation in the local treatment of invasive breast carcinomas 2 cm or less in greatest diameter. MATERIALS AND METHODS:RF ablation of 21 malignant lesions was performed in 20 patients immediately before...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2311030651
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:To compare the use of electrolytically detachable coils versus surgical ligation for the management of acutely ruptured intracranial aneurysm. MATERIALS AND METHODS:A prospective randomized study included 109 patients with acute (< 72 hours) subarachnoid hemorrhage caused by a ruptured aneurysm (Hunt and Hess ...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.211.2.r99ap06325
更新日期:1999-05-01 00:00:00
abstract::The safety of small-caliber firearms in a 1.5-T magnetic resonance (MR) imaging environment was assessed with six handguns, which were unloaded before testing. Each firearm was withdrawn barrel-first to assess the interaction of the magnetic field with the hammer and/or trigger. Two of the six weapons discharged repro...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.193.3.7972840
更新日期:1994-12-01 00:00:00
abstract:PURPOSE:To determine if comparison of in-phase and opposed-phase gradient-echo magnetic resonance (MR) images enables detection of lipid in renal clear cell carcinoma. MATERIALS AND METHODS:A retrospective search of MR and pathologic records identified 43 patients with biopsy-proved renal masses who underwent in-phase...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.205.1.9314970
更新日期:1997-10-01 00:00:00
abstract::Studies of pylmonary clearance of tantalum dust labeled with 182Ta in dogs have been extended to as far as 816 days postexposure in order to substantiate earlier pulmonary retention data, examine lymphatic uptake, and seek long-term pathological changes. Exposure to 5-mug and 10-mug powders was compared with the resul...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.2.415
更新日期:1976-11-01 00:00:00
abstract::A stereotaxic frame, compatible with digital subtraction angiography, computed tomography, and magnetic resonance imaging, is described along with a set of software programs that run in an independent imaging computer system, as well as in the computers associated with each modality. Plexiglas plates fastened to the s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.3.3538140
更新日期:1986-12-01 00:00:00
abstract::Body computed tomographic (CT) scans were reviewed in 73 patients with hematomas of recent onset. The incidence, extent, and morphologic variation of regions of hyperdensity on precontrast scans were assessed. Hyperdensity was also sought in the scans of 80 control subjects with a mass due to neoplasm or abscess demon...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.3.6878700
更新日期:1983-09-01 00:00:00
abstract::A review of 26 cases of columnar-lined (Barrett's) esophagus suggests that this lesion is more common than generally appreciated, usually arising consequent to reflux esophagitis. The radiologically detectable lesions frequently do not support the idea that Barrett's esophagus presents only with high esophageal ulcer ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.1.1
更新日期:1977-04-01 00:00:00
abstract::Failures and complications were analyzed retrospectively in 45 patients treated with embolotherapy or occlusion of pulmonary arterial circulation. Pulmonary arterial branches were occluded with steel coils in 19 patients with pulmonary arteriovenous malformations, 17 with hemoptysis of pulmonary artery (PA) origin, an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.180.3.1871280
更新日期:1991-09-01 00:00:00
abstract::Twenty rhesus monkeys had one kidney irradiated (after undergoing unilateral nephrectomies) with one of four doses: 960 or 1080 rads of 50 MeVd leads to Be neutrons, or 2350 or 2700 rads of 60Co. Whereas animals treated with the lower dose of neutrons or 60Co are alive with relatively normal renal function, those trea...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.1.245
更新日期:1978-07-01 00:00:00
abstract:PURPOSE:To determine if follow-up computed tomography (CT) after definitive radiation therapy for laryngeal or hypopharyngeal (laryngopharyngeal) carcinoma allows the detection of local failure earlier than clinical examination alone. MATERIALS AND METHODS:Pre- and post-radiation therapy follow-up CT scans in 66 patie...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.214.3.r00fe13683
更新日期:2000-03-01 00:00:00
abstract::Magnetic resonance (MR) imaging of the temporomandibular joint was performed in two subjects using a 1.5 T experimental imaging system equipped with a 6.5 cm surface coil antenna. Normal and pathologic anatomy were demonstrated with exquisite detail. Anterior displacement of the joint meniscus was clearly visible in t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.3.3969490
更新日期:1985-03-01 00:00:00
abstract::Internal contamination by 131I among the personnel in a nuclear medicine laboratory was surveyed from January to July, 1979. Because of the formulation change made by the manufacturer in April to reduce volatility, it was possible to study two different therapeutic solutions of 131I. Internal contamination of personne...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.3.7444060
更新日期:1980-12-01 00:00:00
abstract:PURPOSE:To evaluate the prevalence of testicular microlithiasis (TM) in children who have undergone scrotal ultrasonography (US) and their association with testicular tumors. MATERIALS AND METHODS:This HIPAA-compliant study with waiver of informed consent was approved by the institutional review board. From 2003 to 20...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13130394
更新日期:2014-03-01 00:00:00
abstract::The authors performed sympathetic nerve blockades in seven patients with peripheral ischemia and possible autonomic dysfunction. Magnetic resonance (MR) imaging was used to guide needle placement, to monitor distribution of injected agents, and to measure increases in blood flow, which were as much as 10-fold. MR imag...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2231010751
更新日期:2002-05-01 00:00:00
abstract::The specificity of the intraarticular facet block as a diagnostic test for facet joint disease is currently unknown. Capsular rupture with epidural and periarticular diffusion is probably responsible for many false positive findings. We found a comparatively low success rate of the procedure in 25 patients in whom max...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.2.6709900
更新日期:1984-05-01 00:00:00
abstract::Esophageal motor disorders are best evaluated with manometry, which, however, is time-consuming and not generally available. The authors prospectively investigated the yield of videofluoroscopy in detection of esophageal motor disorders in comparison with that of manometry. Eighty-eight patients with dysphagia, globus...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.185.2.1410360
更新日期:1992-11-01 00:00:00
abstract::Twenty angiographic procedures involving the superior mesenteric artery (SMA) were performed with balloon occlusion catheters in dogs with chronic liver cirrhosis and portal hypertension. The following complications were found: (a) rapid balloon inflation during angiography due to a leak between the two catheter lumen...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.140.3.7280230
更新日期:1981-09-01 00:00:00
abstract::Two patients with cystic fibrosis and pancreatic cystosis are described who had complete replacement of the pancreas by multiple macroscopic cysts. The possible causes and clinical significance of this condition are discussed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.3.3511500
更新日期:1986-03-01 00:00:00
abstract::The chest radiographs of asthmatic patients in an emergency room setting over a four-year period were reviewed. A total of 997 radiographs was reviewed; radiographic findings were compared with history and clinical data. In adults 2.2% of the radiographs were abnormal; in children 13%. It is concluded that a chest rad...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.145.1.7122890
更新日期:1982-10-01 00:00:00
abstract::Transforaminal epidural steroid injections (TFESIs) are associated with rare but devastating neurologic complications. Every published case has been associated with a particulate steroid suspension, and the presumed but not proven mechanism is embolization and occlusion of end arterioles. Through an in vivo murine mod...
journal_title:Radiology
pub_type: 评论,杂志文章
doi:10.1148/radiol.2016160171
更新日期:2016-06-01 00:00:00
abstract::The authors report a case of renal cell carcinoma in which computed tomography (CT) revealed fatty tissue and calcification within a solid renal mass. The detection of a mass with negative CT numbers at CT and increased echogenicity at ultrasound led to the incorrect diagnosis of angiomyolipoma (renal hamartoma). The ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.2.8327690
更新日期:1993-08-01 00:00:00
abstract:PURPOSE:To compare the image quality and degree of vessel narrowing at flow-sensitive dephasing (FSD) magnetic resonance (MR) angiography of the hands with those at contrast material-enhanced MR angiography of the hands in patients with systemic sclerosis. MATERIALS AND METHODS:In a single-center study with institutio...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100851
更新日期:2011-04-01 00:00:00
abstract:PURPOSE:To investigate the mechanism of enhancement of hepatocellular carcinoma (HCC) on gadoxetic acid-enhanced hepatobiliary phase magnetic resonance (MR) images and to characterize HCC thus enhanced. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and patient informed ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091557
更新日期:2010-06-01 00:00:00