Abstract:
:Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in two groups of 30 patients referred for suspected disease of the pancreas. In both groups, vascular opacification and anatomic detail were analyzed with a grading system (1 = poor, 2 = good, 3 = excellent). Vascular opacification received mean grades of 2.78 and 2.33 in the spiral CT and control groups, respectively. Anatomic detail received mean grades of 2.63 and 2.42 in the spiral CT and control groups, respectively. Respiratory motion artifact was absent in all spiral CT examinations but was present in 17 of 30 control CT examinations. Images obtained with spiral CT showed superior vascular opacification and reduced respiratory artifact with smaller amounts of contrast agent (90 mL vs 120 mL) compared with those obtained with dynamic CT.
journal_name
Radiologyjournal_title
Radiologyauthors
Dupuy DE,Costello P,Ecker CPdoi
10.1148/radiology.183.3.1584940subject
Has Abstractpub_date
1992-06-01 00:00:00pages
815-8issue
3eissn
0033-8419issn
1527-1315journal_volume
183pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The authors report two cases of coexistent pneumomediastinum and diabetic ketoacidosis. One patient had pneumothorax as well. Hyperpnea or vomiting, or a combination of the two, may be the etiologic agent in such cases. The prognosis is excellent and there is prompt regression of the pneumomediastinum following correc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.3.543
更新日期:1975-09-01 00:00:00
abstract:PURPOSE:To prospectively determine feasibility of contrast material-enhanced magnetic resonance (MR) angiography of the peripheral arteries from distal aorta to pedal arteries with a 1.0-T system and a dedicated phased-array coil. MATERIALS AND METHODS:Twenty-seven patients with peripheral arteriosclerotic occlusive d...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2351031987
更新日期:2005-04-01 00:00:00
abstract::Sixteen of 227 patients referred for percutaneous placement of a ureteral stent had impassable stenoses. Stenoses were benign (n = 8) or attributed to malignant retroperitoneal neoplasm (n = 8). Electrocautery was used to create a neotract between the stenosed ureter and the bladder or ileal loop. A double-J stent was...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.180.2.2068310
更新日期:1991-08-01 00:00:00
abstract::A Kimray-Greenfield filter was inadvertently placed in the right atrium of a patient with multiple pulmonary emboli. A percutaneous technique with the use of a chest tube and basket catheter was performed to retrieve and remove the filter. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.167.2.3357950
更新日期:1988-05-01 00:00:00
abstract:PURPOSE:To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractiona...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132363
更新日期:2015-01-01 00:00:00
abstract::Twenty-three patients were prospectively examined with ultrasound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.3.3517960
更新日期:1986-06-01 00:00:00
abstract::A commercially available double-lumen central venous catheter that can be inserted over a 0.018-inch guide wire was used for ureteral perfusion studies in three infants. Complications or difficulties were not encountered in any patients. This technique allows simultaneous monitoring of perfusion and intrarenal pressur...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.1.1887050
更新日期:1991-10-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the technical feasibility of both high-spatial-resolution and time-resolved contrast material-enhanced magnetic resonance (MR) angiography of the pulmonary circulation at 3.0 T. MATERIALS AND METHODS:All examinations were HIPAA compliant. After institutional review board approval and ...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiol.2403051076
更新日期:2006-09-01 00:00:00
abstract::In diagnostic radiology, the routine measurement of exposure levels for a reference patient is an important part of an effective quality assurance program. In the United States, chest radiography is the most frequent examination and has the lowest exposure level of all radiologic examinations. We estimated the amount ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.2.4011920
更新日期:1985-08-01 00:00:00
abstract::Purpose To develop and validate a deep learning algorithm that predicts the final diagnosis of Alzheimer disease (AD), mild cognitive impairment, or neither at fluorine 18 (18F) fluorodeoxyglucose (FDG) PET of the brain and compare its performance to that of radiologic readers. Materials and Methods Prospective 18F-FD...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180958
更新日期:2019-02-01 00:00:00
abstract::Background Chest CT is used in the diagnosis of coronavirus disease 2019 (COVID-19) and is an important complement to reverse-transcription polymerase chain reaction (RT-PCR) tests. Purpose To investigate the diagnostic value and consistency of chest CT as compared with RT-PCR assay in COVID-19. Materials and Methods ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020200642
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To determine whether enhancement at multiphasic multidetector computed tomography (CT) can help differentiate clear cell renal cell carcinoma (RCC) from oncocytoma, papillary RCC, and chromophobe RCC. MATERIALS AND METHODS:With institutional review board approval for this HIPAA-compliant retrospective study, t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13112617
更新日期:2013-05-01 00:00:00
abstract:PURPOSE:To evaluate the ability of magnetization transfer (MT) contrast-prepared magnetic resonance (MR) imaging to help distinguish healthy from cirrhotic liver by using a spectrum of MT pulse frequency offsets. MATERIALS AND METHODS:This HIPAA-compliant prospective study was approved by the institutional review boar...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11111043
更新日期:2012-01-01 00:00:00
abstract::Six commercially available movable core guide wires were compared with each other and with a new design in glass models simulating tortuous vessels. The results demonstrate a wide variability in performance of the commercially available wires and the superiority of the new design. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.2.3961190
更新日期:1986-05-01 00:00:00
abstract:PURPOSE:To compare areas of contrast material enhancement in the prostate at ultrasonography (US) with whole-mount radical prostatectomy specimens to determine if the use of contrast material improves the detection rate of prostate cancer. MATERIALS AND METHODS:Transrectal US was performed in 12 subjects with cancer o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2222010582
更新日期:2002-02-01 00:00:00
abstract::Comparison radiographs may be used to confirm subtle extremity fractures or dislocations in children. Some suggest that such views be routinely obtained. As determined by questionnaire, however, a clear majority (2:1) of pediatric radiologists do not currently utilize this procedure. Factors determining this are discu...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.1.209
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:To compare the occurrence of several central sulcus variants and to assess the reproducibility of a sulcal pattern named the power button sign (PBS) in patients with type 2 focal cortical dysplasia (FCD2) and healthy control subjects. MATERIALS AND METHODS:The local institutional review board approved the stud...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14140773
更新日期:2015-02-01 00:00:00
abstract::The anatomy of the posterior cerebral artery (PCA) and its branches is described. On the vertebral angiogram, displacement of these vessels is a sign of corresponding displacement of the temporal horn, which in turn is an indication of a mass involving the temporal lobe, diencephalon, or midbrain. Specific angiographi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.2.387
更新日期:1978-08-01 00:00:00
abstract::The authors developed a colostomy appliance for use during barium-enema examinations. It is 8 cm in diameter and 4 cm in height, and is made of acrylic resins. With the use of this device, 21 patients were fluoroscopically examined through the stoma; good contrast views of the lower intestinal tract were obtained in a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/133.1.241
更新日期:1979-10-01 00:00:00
abstract::The radiation dose and the anatomic detail of computed tomography (CT) and conventional tomography were studied in 18 patients with suspected acoustic neuroma, cholesteatoma, malignant tumor, and temporal bone fracture. It is concluded that CT is the technique of choice in patients suspected of having acoustic neuroma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.2.7352220
更新日期:1980-02-01 00:00:00
abstract::Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of rena...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019181100
更新日期:2019-05-01 00:00:00
abstract::Sustentacular-talar tarsal coalitions can be difficult to detect radiographically. The sustentacular-talar articulation is a part of the talocalcaneonavicular joint. Thus, arthrography of this joint, combined with tangential views of the sustentaculotalar articulation (Harris views), provides a new and simple method t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/15.3.730
更新日期:1975-06-01 00:00:00
abstract::An overview of current air-contrast stomach examination techniques is offered: (a) Hampton's technique which does not use distension; (b) the Japanese method which utilizes the relaxant drug Buscopan, good distension, and much patient rotation; (c) a third method in which no drugs are used but more distension is obtai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/117.3.743
更新日期:1975-12-01 00:00:00
abstract::The purpose of this study was to construct and evaluate a phantom for measurement of magnetic resonance (MR) imaging sections with thicknesses of 0.3-0.6 mm. The phantom consisted of 304 0.1-mm-thick disks, each of which had a single notch filled with a diluted solution of gadopentetate dimeglumine. Qualitative and qu...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2401050304
更新日期:2006-08-01 00:00:00
abstract::Clinical, radiological, and pathologic data for nine children with adult respiratory distress syndrome (ARDS) were reviewed. The children ranged in age from 7 months to 15 years (mean age, 7.4 yrs). Underlying diseases and precipitating events included sepsis, pneumonia, near drowning, aspiration pneumonia, central ne...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.157.1.4034980
更新日期:1985-10-01 00:00:00
abstract:PURPOSE:To quantify the effects of spiral computed tomographic (CT) acquisition parameters on the magnitude of three-dimensional (3D) rippling artifacts and polyp depiction. MATERIALS AND METHODS:An in vitro colon phantom was constructed with air-filled acrylic cylinders that contained synthetic polyps of 3-13 mm. The...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.217.1.r00oc13165
更新日期:2000-10-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the role of computer-aided detection (CAD) in reducing the rate of false-negative (FN) findings on screening mammograms considered normal at initial double reading. MATERIALS AND METHODS:At the authors' institution, independent prospective double readings in which the second reader ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2322030034
更新日期:2004-08-01 00:00:00
abstract:PURPOSE:To perform a systematic review and meta-analysis of the diagnostic performance of computed tomography (CT) and magnetic resonance (MR) imaging as noninvasive modalities for evaluating hepatocellular carcinoma (HCC) in patients with chronic liver disease. MATERIALS AND METHODS:A search of the MEDLINE, EMBASE, a...
journal_title:Radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1148/radiol.14140690
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To assess placental perfusion and permeability in mice with magnetic resonance (MR) imaging. MATERIALS AND METHODS:This study was conducted according to French law and National Institutes of Health recommendations for animal care. Twenty-two pregnant BALB/c mice were examined at 1.5 T with a single-section dua...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051168
更新日期:2006-12-01 00:00:00
abstract::The efficacy of the barium enema examination and abdominal computed tomography (CT) was investigated in 81 patients who had undergone operation for colorectal carcinoma. Recurrent disease was found in 52 patients and was divided into local (anastomotic and perianastomotic) and remote (distant and hepatic metastases) t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.2.3562810
更新日期:1987-05-01 00:00:00