Pediatric inflammatory bowel disease: assessment with scintigraphy with 99mTc white blood cells.

Abstract:

PURPOSE:To evaluate the sensitivity and specificity of scintigraphy with technetium 99m white blood cells (WBC) for detection of colonic inflammation in children with and children without inflammatory bowel disease (IBD). MATERIALS AND METHODS:In 215 patients, uptake of 99mTc WBC in 3,440 bowel segments was graded. In 137 of the 215 patients, the 99mTc WBC scans were interpreted blindly and findings compared with results at colonoscopy and endoscopic biopsy. Planar, single photon emission computed tomographic, and maximum-activity-projection images were reviewed together. In 78 children without recent endoscopic biopsy results, 99mTc WBC scan findings were compared with laboratory values, the gastroenterologist's initial clinical assessment, and findings at long-term clinical follow-up. RESULTS:In 128 of 137 children with recent biopsies, findings at histologic examination and on 99mTc WBC scans were correlated. There were seven false-negative and two false-positive studies. Sensitivity was 90%, specificity 97%, positive predictive value 97%, negative predictive value 93%, prevalence of disease 53%, and overall accuracy 93%. In 75 of 78 (96%) children without recent biopsies, 99mTc WBC scan findings were consistent with the laboratory values, gastroenterologist's clinical assessment, and long-term clinical follow-up findings. CONCLUSION:Scintigraphy with 99mTc WBC is a useful noninvasive diagnostic test to determine the extent and distribution of inflammation in children with IBD.

journal_name

Radiology

journal_title

Radiology

authors

Charron M,del Rosario FJ,Kocoshis SA

doi

10.1148/radiology.212.2.r99au45507

subject

Has Abstract

pub_date

1999-08-01 00:00:00

pages

507-13

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

212

pub_type

杂志文章
  • A new photon scattering method for bone mineral density measurements.

    abstract::A new technique for the determination of bone mineral density, based on the detection of both coherently and Compton scattered photons in a narrow beam geometry, is described. Initial results show that this method delivers an accuracy of less than 2% when varying quantities of materials surround the measuring site. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.723

    authors: Puumalainen P,Uimarihuhta A,Olkkonen H

    更新日期:1976-09-01 00:00:00

  • Experimental design and data analysis in receiver operating characteristic studies: lessons learned from reports in radiology from 1997 to 2006.

    abstract:PURPOSE:To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. MATERIALS AND METHODS:Two hundred...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533081632

    authors: Shiraishi J,Pesce LL,Metz CE,Doi K

    更新日期:2009-12-01 00:00:00

  • Complications of arthrography.

    abstract::Arthrography is considered extremely safe since reactions to intraarticular contrast media are rare. We have only seen one severe complication in the performance of more than 2,000 arthrographic procedures. To determine the incidence of complications, a questionnaire was sent to 84 radiologists experienced in arthrogr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001360

    authors: Newberg AH,Munn CS,Robbins AH

    更新日期:1985-06-01 00:00:00

  • Complicated inferior vena cava filter retrievals: associated factors identified at preretrieval CT.

    abstract:PURPOSE:To examine filter characteristics at preretrieval computed tomography (CT) that are associated with complicated inferior vena cava (IVC) filter retrieval procedures. MATERIALS AND METHODS:This study was HIPAA compliant, and informed consent was waived. Institutional review board-approved retrospective review o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120372

    authors: Dinglasan LA,Oh JC,Schmitt JE,Trerotola SO,Shlansky-Goldberg RD,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Ghost infantile vertebrae and hemipelves within adult skeleton from thorotrast administration in childhood.

    abstract::In 2 adults who had received thorotrast intravenously at ages 2 and 3 years, respectively, radiopaque outlines of their infantile vertebrae were seen in the adult vertebrae. Similar "ghosts" of the hemipelves were present in the pelvis of 1 patient. Autopsy findings and autoradiographs in 1 patient strongly suggest th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.3.657

    authors: Teplick JG,Head GL,Kricun ME,Haskin ME

    更新日期:1978-12-01 00:00:00

  • Exogenous lung surfactant: effect on radiographic appearance in premature infants.

    abstract::At birth, premature infants of 25-29 weeks gestation, at high risk for development of neonatal respiratory distress syndrome (RDS), were given a single dose (90 mg) of calf lung surfactant extract (CLSE) by intratracheal instillation. The frequency and severity of RDS were assessed with use of a simple radiographic sc...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.165.1.3306780

    authors: Wood BP,Sinkin RA,Kendig JW,Notter RH,Shapiro DL

    更新日期:1987-10-01 00:00:00

  • Liver metabolite concentrations measured with 1H MR spectroscopy.

    abstract:PURPOSE:To determine the feasibility of measuring choline and glycogen concentrations in normal human liver in vivo with proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy. MATERIALS AND METHODS:Signed consent to participate in an institutional review board-approved and HIPAA-compliant study was obtained fr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112344

    authors: Ouwerkerk R,Pettigrew RI,Gharib AM

    更新日期:2012-11-01 00:00:00

  • Noxious somatosensory stimulation affects the default mode of brain function: evidence from functional MR imaging.

    abstract:PURPOSE:To investigate whether default mode network (DMN) spatial properties can be directly affected by pain, with a comparison of painful and nonpainful conditions. MATERIALS AND METHODS:The authors performed a functional magnetic resonance (MR) imaging study, approved by the local institutional ethics committee, in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533090602

    authors: Mantini D,Caulo M,Ferretti A,Romani GL,Tartaro A

    更新日期:2009-12-01 00:00:00

  • Relationship of Trochlear Morphology and Patellofemoral Joint Alignment to Superolateral Hoffa Fat Pad Edema on MR Images in Individuals with or at Risk for Osteoarthritis of the Knee: The MOST Study.

    abstract::Purpose To determine the relationship of patellofemoral joint alignment and trochlear morphology to superolateral Hoffa fat pad (SHFP) edema on magnetic resonance (MR) images in older adults with or at risk for osteoarthritis of the knee. Materials and Methods Institutional review board approval and written informed c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162342

    authors: Widjajahakim R,Roux M,Jarraya M,Roemer FW,Neogi T,Lynch JA,Lewis CE,Torner JC,Felson DT,Guermazi A,Stefanik JJ

    更新日期:2017-09-01 00:00:00

  • Liver adenomatosis: clinical, histopathologic, and imaging findings in 15 patients.

    abstract:PURPOSE:To report and correlate the clinical, histopathologic, and imaging findings in 15 patients with liver adenomatosis. MATERIALS AND METHODS:Fifteen adult patients had more than 10 hepatic adenomas each and no history of glycogen storage disease or anabolic steroid use. Ten of them underwent bolus-enhanced dynami...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.2.r00jl38395

    authors: Grazioli L,Federle MP,Ichikawa T,Balzano E,Nalesnik M,Madariaga J

    更新日期:2000-08-01 00:00:00

  • Lateral C1-2 puncture for cervical myelography. Part III: Historical, anatomic, and technical considerations.

    abstract::Three significantly different lateral approaches to the cervical subarachnoid space (anterior, midplane, and posterior needle positions) have been previously described for cordotomy and myelography. Experimental lateral C1-2 punctures were performed by each of these three methods in anatomic specimens, cadaver models ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.2.6687370

    authors: Orrison WW,Eldevik OP,Sackett JF

    更新日期:1983-02-01 00:00:00

  • Peripheral cholangiocarcinoma and clonorchiasis: CT findings.

    abstract::Sixteen patients with peripheral cholangiocarcinoma of the liver were examined with computed tomography (CT). None of the 16 patients presented with jaundice or had documented cirrhosis. On scans obtained both before and after the injection of contrast material, the tumors were depicted as low-attenuation masses in al...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.1.2843940

    authors: Choi BI,Park JH,Kim YI,Yu ES,Kim SH,Kim WH,Kim CY,Han MC

    更新日期:1988-10-01 00:00:00

  • Case 230: Congenital Inguinal Herniation of the Left Ureter (Extraperitoneal Form).

    abstract::History A 52-year-old man with a history of urinary tract infections and a previous clinical diagnosis of left inguinal hernia presented to the nephrologist with recent onset of dysuria and increasing swelling in the left inguinoscrotal region in the absence of fever or scrotal trauma. There was no relevant surgical o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.16141805

    authors: Di Nicolò P,Aleo D,Riccioli E,Granata A

    更新日期:2016-06-01 00:00:00

  • The scanning grid: a novel and effective bucky movement.

    abstract::A grid consisting of a focused array of radiopaque strips has been constructed. No interspace material is employed, and, during an exposure, the arrangement moves so that the grid strips remain focused and a uniform film density is obtained. Preliminary measurements and radiographs of patients indicate that such a dev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.3.7384470

    authors: Barnes GT,Moreland RF,Yester MV,Witten DM

    更新日期:1980-06-01 00:00:00

  • Ultrasonography in the staging of endometrial adenocarcinoma.

    abstract::Adenocarcinoma of the endometrium commonly presents at an early stage and is readily diagnosed by dilatation and curettage. Ultrasound has not bee accurate in differentiating this malignant neoplasm from benign causes of uterine enlargement such as leiomyoma. In this study, the sonographic findings in 21 patients with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.3.7280250

    authors: Requard CK,Wicks JD,Mettler FA Jr

    更新日期:1981-09-01 00:00:00

  • Exogenous gene expression in tumors: noninvasive quantification with functional and anatomic imaging in a mouse model.

    abstract:PURPOSE:To assess whether a combination of functional (planar imaging and single photon emission computed tomography [SPECT]) and anatomic (magnetic resonance [MR] imaging) imaging techniques can be used to noninvasively quantify tumor expression of a somatostatin receptor type 2A (SSTR2A) gene chimera in vivo. MATERI...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2353040108

    authors: Yang D,Han L,Kundra V

    更新日期:2005-06-01 00:00:00

  • Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.

    abstract:PURPOSE:To evaluate a percutaneous pulmonary embolism (PE) thrombectomy catheter that aspirates, macerates, and removes thrombus. MATERIALS AND METHODS:Nine in vitro tests were performed by using porcine thrombi at a PE test station that provides continuous fluid output of 2 L/min at a pressure of 50 mmHg. Macroemboli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041287

    authors: Kucher N,Windecker S,Banz Y,Schmitz-Rode T,Mettler D,Meier B,Hess OM

    更新日期:2005-09-01 00:00:00

  • The lactating breast: contrast-enhanced MR imaging of normal tissue and cancer.

    abstract:PURPOSE:To retrospectively describe the magnetic resonance (MR) imaging characteristics of normal breast tissue and breast cancer in the setting of lactation. MATERIALS AND METHODS:The HIPAA-compliant study was exempt from institutional approval, and informed consent was not required. Unilateral MR imaging of 10 breas...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2372040837

    authors: Espinosa LA,Daniel BL,Vidarsson L,Zakhour M,Ikeda DM,Herfkens RJ

    更新日期:2005-11-01 00:00:00

  • Percutaneous insertion of the Kimray-Greenfield filter: technical considerations and problems.

    abstract::Kimray-Greenfield filters were inserted percutaneously into the inferior vena cava (IVC) in 57 patients. Thirty-six were placed from the right femoral vein, 14 from the left femoral vein, and seven from the right internal jugular vein. There were no deaths or major complications and only six minor complications. Infer...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3659360

    authors: Pais SO,Mirvis SE,De Orchis DF

    更新日期:1987-11-01 00:00:00

  • Bowel and mesenteric injury following blunt abdominal trauma: evaluation with CT.

    abstract::Computed tomography (CT) used in cases of blunt abdominal trauma has been found sensitive in detection of bowel and mesenteric injuries and discrimination of operable from nonoperable candidates. In 51 patients with suspected bowel or mesenteric injury following blunt abdominal trauma, CT correctly depicted bowel hema...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.1.2781000

    authors: Rizzo MJ,Federle MP,Griffiths BG

    更新日期:1989-10-01 00:00:00

  • Enhancement of vascular permeability with low-frequency contrast-enhanced ultrasound in the chorioallantoic membrane model.

    abstract:PURPOSE:To characterize the effect of low-frequency contrast material-enhanced ultrasound on the vascular endothelium and to determine the parameters and techniques required to deliver a therapeutic agent by using the chorioallantoic membrane (CAM) model. MATERIALS AND METHODS:All in vivo animal procedures were conduc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2431060167

    authors: Stieger SM,Caskey CF,Adamson RH,Qin S,Curry FR,Wisner ER,Ferrara KW

    更新日期:2007-04-01 00:00:00

  • Malignant ureteral obstruction: treatment with metal stents--technique, results, and observations with percutaneous intraluminal US.

    abstract:PURPOSE:To test the technical feasibility and results of placement of metal stents into ureters obstructed by extensive tumor. MATERIALS AND METHODS:Six consecutive patients (two men and four women, aged 35-66 years and with incurable malignancies) underwent insertion of metallic endoprostheses in nine obstructed uret...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184060

    authors: vanSonnenberg E,D'Agostino HB,O'Laoide R,Donaldson J,Sanchez RB,Hoyt A,Pittman CC

    更新日期:1994-06-01 00:00:00

  • Nasofrontal duct: CT in frontal sinus trauma.

    abstract::Radiologic evaluation of frontal sinus fractures is instrumental in determining the need for surgery. Computed tomography (CT) is an excellent modality for evaluation of frontal sinus trauma, particularly for anterior and posterior wall fractures. However, fractures of the nasofrontal duct are more difficult to deline...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.1.3628770

    authors: Harris L,Marano GD,McCorkle D

    更新日期:1987-10-01 00:00:00

  • T2 relaxation time of cartilage at MR imaging: comparison with severity of knee osteoarthritis.

    abstract:PURPOSE:To evaluate differences in T2 values in femoral and tibial cartilage at magnetic resonance (MR) imaging in patients with varying degrees of osteoarthritis (OA) compared with healthy subjects and to develop a mapping and display method based on calculation of T2 z scores for visual grading and assessment of cart...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2322030976

    authors: Dunn TC,Lu Y,Jin H,Ries MD,Majumdar S

    更新日期:2004-08-01 00:00:00

  • Radiographic absorptiometry for bone mineral measurement of the phalanges: precision and accuracy study.

    abstract:PURPOSE:To evaluate the accuracy and precision of a radiographic absorptiometry (RA) method for assessment of bone mineral of the middle phalanges. MATERIALS AND METHODS:Nineteen cadaveric hands were radiographed with an aluminum wedge, once at 50 kVp and 400 mA and once at 60 kVp and 300 mA. Bone mineral content (BMC...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.3.8058960

    authors: Yang SO,Hagiwara S,Engelke K,Dhillon MS,Guglielmi G,Bendavid EJ,Soejima O,Nelson DL,Genant HK

    更新日期:1994-09-01 00:00:00

  • Cervical spine: three-dimensional MR imaging with magnetization transfer prepulsed turbo field echo techniques.

    abstract::In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepuls...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.3.9609910

    authors: Melhem ER,Caruthers SD,Jara H

    更新日期:1998-06-01 00:00:00

  • Biphasic CT with mesenteric CT angiography in the evaluation of acute mesenteric ischemia: initial experience.

    abstract:PURPOSE:To evaluate the sensitivity and specificity of biphasic computed tomography (CT) with mesenteric CT angiography in the diagnosis of acute mesenteric ischemia (AMI). MATERIALS AND METHODS:Sixty-two patients with clinically suspected AMI underwent prospective imaging with biphasic multi-detector row CT. Mesenter...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2291020991

    authors: Kirkpatrick ID,Kroeker MA,Greenberg HM

    更新日期:2003-10-01 00:00:00

  • Combat-related Mild Traumatic Brain Injury: Association between Baseline Diffusion-Tensor Imaging Findings and Long-term Outcomes.

    abstract::Purpose To determine whether functional outcomes of veterans who sustained combat-related mild traumatic brain injury (TBI) are associated with scalar metrics derived from diffusion-tensor (DT) imaging at their initial postdeployment evaluation. Materials and Methods This HIPAA-compliant retrospective study was approv...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151013

    authors: Ware JB,Biester RC,Whipple E,Robinson KM,Ross RJ,Nucifora PG

    更新日期:2016-07-01 00:00:00

  • Clinical applications of PET in oncology.

    abstract::Positron emission tomography (PET) provides metabolic information that has been documented to be useful in patient care. The properties of positron decay permit accurate imaging of the distribution of positron-emitting radiopharmaceuticals. The wide array of positron-emitting radiopharmaceuticals has been used to char...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2312021185

    authors: Rohren EM,Turkington TG,Coleman RE

    更新日期:2004-05-01 00:00:00

  • Growth of the fetal biparietal diameter in different types of pregnancies.

    abstract::A total of 24,560 fetal biparietal measurements were made using the B-scan technique. The increase in biparietal diameter was compared in normal pregnancies, in those complicated by diabetes or toxemia, and in fetuses thought to be small for dates. Only the last of these groups demonstrated a statistically significant...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.1.7422840

    authors: Aantaa K,Forss M

    更新日期:1980-10-01 00:00:00