Lateral C1-2 puncture for cervical myelography. Part III: Historical, anatomic, and technical considerations.

Abstract:

:Three significantly different lateral approaches to the cervical subarachnoid space (anterior, midplane, and posterior needle positions) have been previously described for cordotomy and myelography. Experimental lateral C1-2 punctures were performed by each of these three methods in anatomic specimens, cadaver models with reconstituted cerebrospinal fluid pressures, a patient with cerebral death, and to a limited degree in patients undergoing routine cervical myelography. In the cervical region the dura is pushed ahead of the needle, forming a "tent" over the needle tip during C1-2 puncture; the needle projects several millimeters into the spinal canal before penetrating the dura, regardless of the method of entry or needle diameter. The extent of this tenting phenomenon and its relationship to the spinal cord are significantly affected by the needle diameter and position. A posterior technique for lateral C1-2 puncture is described.

journal_name

Radiology

journal_title

Radiology

authors

Orrison WW,Eldevik OP,Sackett JF

doi

10.1148/radiology.146.2.6687370

subject

Has Abstract

pub_date

1983-02-01 00:00:00

pages

401-8

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

146

pub_type

杂志文章
  • Liver transplant biopsies with a biopsy gun.

    abstract::The authors evaluated the safety and efficacy of a biopsy gun for performance of image-guided percutaneous biopsy of hepatic allografts in liver transplant recipients. Two hundred fifty-two liver biopsies were performed in 58 transplant recipients over a 27-month period by using this instrument with an 18-gauge needle...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014290

    authors: Chezmar JL,Keith LL,Nelson RC,Plaire JC,Hertzler GL,Bernardino ME

    更新日期:1991-05-01 00:00:00

  • Childhood leukemia: diagnostic accuracy of bedside chest radiography for severe pulmonary complications.

    abstract:PURPOSE:To determine the diagnostic accuracy of bedside chest radiography in patients who develop severe pulmonary complications while undergoing therapy for leukemia. MATERIALS AND METHODS:The authors studied 45 patients, aged 21 years and younger, who died of leukemia or of treatment complications and for whom autop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.1.8090880

    authors: Winer-Muram HT,Rubin SA,Fletcher BD,Kauffman WM,Jennings SG,Arheart KL,Bozeman PM

    更新日期:1994-10-01 00:00:00

  • Thoracic aorta: rapid black-blood MR imaging with half-Fourier rapid acquisition with relaxation enhancement with or without electrocardiographic triggering.

    abstract:PURPOSE:To evaluate and compare findings for thoracic aortic disease with three black-blood magnetic resonance (MR) pulse sequences: half-Fourier rapid acquisition with relaxation enhancement (RARE), with and without electrocardiographic (ECG) triggering, and ECG-triggered turbo spin echo (SE). MATERIALS AND METHODS:A...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.1.r99oc48185

    authors: Stemerman DH,Krinsky GA,Lee VS,Johnson G,Yang BM,Rofsky NM

    更新日期:1999-10-01 00:00:00

  • Non-Hodgkin lymphoma: influence of lymphography, CT, and bone marrow biopsy on staging and management.

    abstract::This prospective study assesses the contribution of lymphography (LAG), abdominal-pelvic computed tomography (CT), and bone marrow biopsy to the staging and management of 168 consecutive cases of newly diagnosed non-Hodgkin lymphoma (NHL). LAG and/or CT influenced Ann Arbor clinical stage (CS) in 39 patients (23%) and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2909090

    authors: Pond GD,Castellino RA,Horning S,Hoppe RT

    更新日期:1989-01-01 00:00:00

  • Esophageal motor disorders: videofluoroscopic and manometric evaluation--prospective study in 88 symptomatic patients.

    abstract::Esophageal motor disorders are best evaluated with manometry, which, however, is time-consuming and not generally available. The authors prospectively investigated the yield of videofluoroscopy in detection of esophageal motor disorders in comparison with that of manometry. Eighty-eight patients with dysphagia, globus...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.2.1410360

    authors: Schima W,Stacher G,Pokieser P,Uranitsch K,Nekahm D,Schober E,Moser G,Tscholakoff D

    更新日期:1992-11-01 00:00:00

  • Trends in Diagnostic Imaging Utilization among Medicare and Commercially Insured Adults from 2003 through 2016.

    abstract::Background Trends in noninvasive diagnostic imaging (NDI) utilization rates have predominantly been reported in Medicare enrollees. To the authors' knowledge, there has been no prior direct comparison of utilization rates between Medicare and commercially insured patients. Purpose To analyze trends in NDI utilization ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019191116

    authors: Hong AS,Levin D,Parker L,Rao VM,Ross-Degnan D,Wharam JF

    更新日期:2020-02-01 00:00:00

  • Intestinal malrotation in children: tutorial on radiographic diagnosis in difficult cases.

    abstract:PURPOSE:To analyze difficult diagnostic cases of malrotation to identify features crucial to accurate diagnosis. MATERIALS AND METHODS:The authors reviewed the radiographs and records of 81 symptomatic children who underwent surgery with a preoperative diagnosis of malrotation. Eleven had subtle rotational abnormaliti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.3.8628870

    authors: Long FR,Kramer SS,Markowitz RI,Taylor GE,Liacouras CA

    更新日期:1996-03-01 00:00:00

  • Tibiotalar slant: a new observation in sickle cell anemia.

    abstract::Several examples of a peculiar deforming process about the ankle joint resulting in a tibiotalar deformity are reported. When found in black patients, further examination for sickle cell disease should be done. No previous mention of this deformity in connection with sickle cell anemia has been found. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.3.551

    authors: Shaub MS,Rosen R,Boswell W,Gordonson J

    更新日期:1975-12-01 00:00:00

  • Pulmonary pseudonodule.

    abstract::A nodular density seen at the posterior lung base on lateral chest radiographs proved to be normal bone in the spine. This nodule results from slight thickening of the bone at the superior aspect of the area where the two laminae join to form the spinous process. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.311

    authors: Shortsleeve MJ,Foster SC

    更新日期:1979-05-01 00:00:00

  • Brachytherapy for prophylaxis of restenosis after long-segment femoropopliteal angioplasty: pilot study.

    abstract:PURPOSE:To evaluate in a pilot study the feasibility and efficacy of endovascular brachytherapy for prophylaxis of restenosis after femoropopliteal percutaneous transluminal angioplasty (PTA) without stent implantation in a group of patients with a high risk of restenosis. MATERIALS AND METHODS:Ten patients (six women...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.1.9646810

    authors: Minar E,Pokrajac B,Ahmadi R,Maca T,Seitz W,Stümpflen A,Pötter R,Ehringer H

    更新日期:1998-07-01 00:00:00

  • Atraumatic evaluation of myocardial revascularization procedures with 43K1.

    abstract::Least-squares regression analysis was computerized to provide functional color images of myocardial perfusion patterns. In 8 of the 9 patients studied, changes in pattern indicated that the revascularization procedure speeded the appearance time and/or net rate of 43K uptake. The functional images correlated well with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.1.99

    authors: Smith RO,Bennett KR,Suzuki A,Lehan PH,Hellems HK

    更新日期:1975-01-01 00:00:00

  • Colorectal cancer overlooked at barium enema examination and colonoscopy: a continuing perceptual problem.

    abstract:PURPOSE:To evaluate reasons for missed diagnosis of colorectal carcinoma at barium enema (BE) examination and colonoscopy and determine if standards have improved since a similar study in 1981. MATERIALS AND METHODS:Relevant studies obtained within 3 years of diagnosis in 161 patients with colorectal carcinoma treated...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.2.8029400

    authors: Brady AP,Stevenson GW,Stevenson I

    更新日期:1994-08-01 00:00:00

  • Pulmonary arteriography in the high-risk patient.

    abstract::Pulmonary arteriography is an invasive but relatively safe diagnostic procedure. It is generally believed that the presence of pulmonary hypertension is one risk factor that increases the likelihood of a major complication. To assess the magnitude of risk, the reports on 1,434 patients who underwent pulmonary arteriog...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.1.3786760

    authors: Perlmutt LM,Braun SD,Newman GE,Oke EJ,Dunnick NR

    更新日期:1987-01-01 00:00:00

  • False-Positive Measurement at 2-Hydroxyglutarate MR Spectroscopy in Isocitrate Dehydrogenase Wild-Type Glioblastoma: A Multifactorial Analysis.

    abstract::Background Isocitrate dehydrogenase (IDH) mutation has become one of the most important prognostic biomarkers in glioma management. Measurement of 2-hydroxyglutarate (2HG) with MR spectroscopy has shown high pooled sensitivity, although false-positive results with MR spectroscopy have been reported. Purpose To investi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019182200

    authors: Suh CH,Kim HS,Paik W,Choi C,Ryu KH,Kim D,Woo DC,Park JE,Jung SC,Choi CG,Kim SJ

    更新日期:2019-06-01 00:00:00

  • Extravasation detection accessory: clinical evaluation in 500 patients.

    abstract:PURPOSE:To assess the ability of an extravasation detection accessory (EDA) to detect clinically important (> or = 10 mL) extravascular injection of iodinated contrast material delivered with an automated power injector. MATERIALS AND METHODS:Five hundred patients referred for contrast material-enhanced body computed ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.212.2.r99au14431

    authors: Birnbaum BA,Nelson RC,Chezmar JL,Glick SN

    更新日期:1999-08-01 00:00:00

  • Metallic stents in the treatment of benign diseases of the colon: preliminary experience in 10 cases.

    abstract:PURPOSE:To assess the effectiveness of and complications associated with metallic stent placement for treatment of benign diseases of the colon. MATERIALS AND METHODS:With radiologic guidance, the authors placed metallic stents in 10 patients with benign diseases of the colon: Nine stents were placed in the rectosigmo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2233010866

    authors: Paúl L,Pinto I,Gómez H,Fernández-Lobato R,Moyano E

    更新日期:2002-06-01 00:00:00

  • Focal liver tumors: characterization with 3D perflubutane microbubble contrast agent-enhanced US versus 3D contrast-enhanced multidetector CT.

    abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2511081324

    authors: Luo W,Numata K,Morimoto M,Kondo M,Takebayashi S,Okada M,Morita S,Tanaka K

    更新日期:2009-04-01 00:00:00

  • Adult respiratory distress syndrome from overdose of tricyclic antidepressants.

    abstract::Adult respiratory distress syndrome (ARDS) from overdose of tricyclic antidepressants (TCA) has been reported but is not well known. During a 1-year period, 81 patients with serious overdose from tranquilizers and other psychotropic drugs were examined. TCA alone induced overdose in 30 patients or were combined with o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.3.2916020

    authors: Varnell RM,Godwin JD,Richardson ML,Vincent JM

    更新日期:1989-03-01 00:00:00

  • Conspicuity of renal calculi at unenhanced CT: effects of calculus composition and size and CT technique.

    abstract:PURPOSE:To determine the effects of calculus size, composition, and technique (kilovolt and milliampere settings) on the conspicuity of renal calculi at unenhanced helical computed tomography (CT). MATERIALS AND METHODS:The authors performed unenhanced CT of a phantom containing 188 renal calculi of varying size and c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251010242

    authors: Tublin ME,Murphy ME,Delong DM,Tessler FN,Kliewer MA

    更新日期:2002-10-01 00:00:00

  • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection.

    abstract::The purpose of this study was to evaluate an automatic boundary detection algorithm of the left ventricle on magnetic resonance (MR) short-axis images with the essential restriction of no manual corrections. The study comprised 13 patients (nine men, four women) and 12 healthy volunteers (11 men, one woman), and insti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2401050471

    authors: van Geuns RJ,Baks T,Gronenschild EH,Aben JP,Wielopolski PA,Cademartiri F,de Feyter PJ

    更新日期:2006-07-01 00:00:00

  • Exercise radionuclide ventriculography: practical considerations and sensitivity of coronary artery disease detection.

    abstract::Eighty-nine patients were evaluated for coronary artery disease (CAD) with exercise radionuclide ventriculography (ERV) and contrast coronary angiography. In 70 patients with documented lesions the ERV was abnormal in 65 for a sensitivity of 93%. In patients with normal coronary arteries, the ERV was abnormal in none ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.3.697

    authors: Brady TJ,Thrall JH,Clare JM,Rogers WL,Lo K,Pitt B

    更新日期:1979-09-01 00:00:00

  • Lymphomas and high-grade astrocytomas: comparison of water diffusibility and histologic characteristics.

    abstract:PURPOSE:To determine if water diffusivity within lymphomas and high-grade astrocytomas correlates with cellularity. MATERIALS AND METHODS:Echo-planar diffusion-weighted magnetic resonance (MR) images obtained in 11 patients with brain lymphomas (19 lesions) and in 17 patients with astrocytomas (19 lesions) were retros...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2241010637

    authors: Guo AC,Cummings TJ,Dash RC,Provenzale JM

    更新日期:2002-07-01 00:00:00

  • A simplified method for intracavitary radiation for recurrent nasopharyngeal carcinoma.

    abstract::A simplified method for constructing a custom-made mold to hold radium for intracavitary radiation therapy of recurrent nasopharyngeal carcinoma was developed. The technique for fabrication and insertion of the mold in a single operative procedure is described. Computer dose distributions were obtained and the applica...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.534

    authors: Smith HS,Lapinski MV,Barr CE

    更新日期:1979-05-01 00:00:00

  • Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.

    abstract::Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161880

    authors: Huang SY,Eggers M,McArthur MJ,Dixon KA,McWatters A,Dria S,Hill LR,Melancon MP,Steele JR,Wallace MJ

    更新日期:2017-12-01 00:00:00

  • "Arthrography diagnosis of synovial cysts of the knee.".

    abstract::A lateral view of the knee in 90 degree flexion can reveal popliteal cysts which do not show on routine arthrography. Flexion causes transfer of intra-articular fluid to the posterior portion of the joint space, lowering pressure within the cyst and allowing it to fill with contrast media. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.2.480

    authors: Clark JM

    更新日期:1975-05-01 00:00:00

  • Diagnosis of osteomyelitis in children by combined blood pool and bone imaging.

    abstract::Differentiation of osteomyelitis from cellulitis or septic arthritis can be difficult. The radiological examination often does not have the characteristic features. Seventy of 71 children with osteomyelitis had focal areas of increased radioactivity at the site of the infection. The addition of "blood pool" images aid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.2.331

    authors: Gilday DL,Paul DJ,Paterson J

    更新日期:1975-11-01 00:00:00

  • Radiation-induced uterine changes: MR imaging.

    abstract::To assess the capability of magnetic resonance (MR) imaging to demonstrate postirradiation changes in the uterus, MR studies of 23 patients who had undergone radiation therapy were retrospectively examined and compared with those of 30 patients who had not undergone radiation therapy. MR findings were correlated with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2909120

    authors: Arrivé L,Chang YC,Hricak H,Brescia RJ,Auffermann W,Quivey JM

    更新日期:1989-01-01 00:00:00

  • Lateral C1-2 puncture for myelography: posterior approach.

    abstract::The lateral C1-2 puncture approach for myelography is a modification of the technique for percutaneous radiofrequency cervical cordotomy. Positioning of the needle in the posterior, rather than anterior, one third of the canal avoids injury to anomalous vertebral artery branches which lie in the anterior half of the n...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.3.760

    authors: Rice JF,Bathia AL

    更新日期:1979-09-01 00:00:00

  • CT colonography for combined colonic and extracolonic surveillance after curative resection of colorectal cancer.

    abstract:PURPOSE:To determine the accuracy of contrast material-enhanced computed tomographic (CT) colonography for postoperative surveillance in colorectal cancer patients without clinical or laboratory evidence of disease recurrence. MATERIALS AND METHODS:The Institutional Review Board approved this HIPAA-compliant study and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100385

    authors: Kim HJ,Park SH,Pickhardt PJ,Yoon SN,Lee SS,Yee J,Kim DH,Kim AY,Kim JC,Yu CS,Ha HK

    更新日期:2010-12-01 00:00:00

  • Wavelet compression of low-dose chest CT data: effect on lung nodule detection.

    abstract:PURPOSE:To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS:One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2281020254

    authors: Ko JP,Rusinek H,Naidich DP,McGuinness G,Rubinowitz AN,Leitman BS,Martino JM

    更新日期:2003-07-01 00:00:00