Liver metabolite concentrations measured with 1H MR spectroscopy.

Abstract:

PURPOSE:To determine the feasibility of measuring choline and glycogen concentrations in normal human liver in vivo with proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy. MATERIALS AND METHODS:Signed consent to participate in an institutional review board-approved and HIPAA-compliant study was obtained from 46 subjects (mean age, 46 years±17 [standard deviation]; 24 women) consecutively recruited during 285 days. Navigator-gated MR images were used to select 8-mL volumes for point-resolved spectroscopy (PRESS) with a 35-msec echo time. Line widths were minimized with fast breath-hold B0 field mapping and further manual shimming. Navigator-gated spectra were recorded with and without water suppression to determine metabolite concentrations with water signals as an internal reference. In three subjects, echo time was varied to determine the glycogen and choline T2. Linear regression analysis was used to examine relations between choline, hepatic lipid content, body mass index, glycogen content, and age. RESULTS:Choline concentrations could be determined in 46 of 48 studies and was found to be 8.6 mmol per kilogram of wet weight±3.1 (range, 3.8-17.6; n=44). Twenty-seven spectra in 25 individuals with narrow line widths and low lipid content were adequate for quantitation of glycogen. The glycogen (glucosyl unit) concentration was 38.1 mmol/kg wet weight±14.4. The T2 of combined glycogen peaks in the liver of three subjects was 36 msec±8. Choline levels showed a weak but significant correlation with glycogen (r2=0.15; P<.05) but not with lipid content. CONCLUSION:Navigator-gated and gradient-echo shimmed PRESS 1H MR spectroscopy may allow quantification of liver metabolites that are important for understanding and identifying disorders of glucose and lipid metabolism.

journal_name

Radiology

journal_title

Radiology

authors

Ouwerkerk R,Pettigrew RI,Gharib AM

doi

10.1148/radiol.12112344

subject

Has Abstract

pub_date

2012-11-01 00:00:00

pages

565-75

issue

2

eissn

0033-8419

issn

1527-1315

pii

radiol.12112344

journal_volume

265

pub_type

杂志文章
  • Low-megavoltage electron-beam therapy of head and facial skin cancer using a versatile polystyrene collimator system.

    abstract::Twenty patients with multiple or recurrent superficial head and facial cancer were treated with low-megavoltage electron-beam therapy, using a readily adaptable polystyrene shield assembly with interchangeable collimators. Patient set-up times were reduced, treatment was simplified, and flexibility of therapy was achi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.695

    authors: Johnson TS,Garciga CE,Feldman ME,Holcomb MH

    更新日期:1975-06-01 00:00:00

  • Human breast cancer in vivo: H-1 and P-31 MR spectroscopy at 1.5 T.

    abstract::To assess the potential of in vivo magnetic resonance (MR) spectroscopy for breast cancer, hydrogen-1 and phosphorus-31 MR spectra of five malignant human breast tumors were compared with those of unaffected breast tissue. The water-to-fat ratio was high in the tumors (average, 2.2) but low in the unaffected tissue (a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.2847230

    authors: Sijens PE,Wijrdeman HK,Moerland MA,Bakker CJ,Vermeulen JW,Luyten PR

    更新日期:1988-12-01 00:00:00

  • Pulmonary infections after bone marrow transplantation: clinical and radiographic findings.

    abstract:PURPOSE:To assess the clinical and radiographic findings of pulmonary infections diagnosed by using invasive means. MATERIALS AND METHODS:Fifty-nine episodes of pulmonary infection were diagnosed in 52 (7.2%) of a consecutive series of 725 adult bone marrow transplant recipients. Causative organisms, time of diagnoses...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.3.r99mr39699

    authors: Leung AN,Gosselin MV,Napper CH,Braun SG,Hu WW,Wong RM,Gasman J

    更新日期:1999-03-01 00:00:00

  • The opossum as an animal model for studying radiation esophagitis.

    abstract::Six opossums were evaluated as a possible animal model of radiation esophagitis. In a single exposure to the esophagus, four animals received 60Co radiation of various doses; two served as controls. Pre- and postirradiation evaluations using fiberoptic endoscopy, mucosal biopsy, barium esophagography, and manometry we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.3.731

    authors: Northway MG,Libshitz HI,West JJ,Withers HR,Mukhopadhyay AK,Osborne BM,Szwarc IA,Dodd GD

    更新日期:1979-06-01 00:00:00

  • Effect of cross-sectional imaging on negative appendectomy and perforation rates in children.

    abstract:PURPOSE:To compare negative appendectomy and perforation rates in children who underwent ultrasonography (US), computed tomography (CT), or no imaging before urgent appendectomy. MATERIALS AND METHODS:All children who underwent urgent appendectomy during a 4(1/2)-year period were identified in a surgical billing datab...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.220.1.r01jl17103

    authors: Applegate KE,Sivit CJ,Salvator AE,Borisa VJ,Dudgeon DL,Stallion AE,Grisoni ER

    更新日期:2001-07-01 00:00:00

  • Transbronchial biopsy with virtual CT bronchoscopy and nodal highlighting.

    abstract::Transbronchial biopsy to sample lymph nodes and tumors that are not visible at endoscopy has a poor (<50%) success rate. These nodes can be highlighted easily at virtual computed tomographic (CT) bronchoscopy to provide a guide. This study was performed to evaluate if the addition of this information to the bronchosco...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2211001585

    authors: Hopper KD,Lucas TA,Gleeson K,Stauffer JL,Bascom R,Mauger DT,Mahraj R

    更新日期:2001-11-01 00:00:00

  • Magnetization transfer contrast-prepared MR imaging of the liver: inability to distinguish healthy from cirrhotic liver.

    abstract:PURPOSE:To evaluate the ability of magnetization transfer (MT) contrast-prepared magnetic resonance (MR) imaging to help distinguish healthy from cirrhotic liver by using a spectrum of MT pulse frequency offsets. MATERIALS AND METHODS:This HIPAA-compliant prospective study was approved by the institutional review boar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11111043

    authors: Rosenkrantz AB,Storey P,Gilet AG,Niver BE,Babb JS,Hajdu CH,Lee VS

    更新日期:2012-01-01 00:00:00

  • Desmoplastic small round cell tumor of the abdomen: radiologic-histopathologic correlation.

    abstract:PURPOSE:To characterize the imaging features of desmoplastic small round cell tumor of the abdomen and correlate them with the histopathologic findings. MATERIALS AND METHODS:Eleven of 14 patients with desmoplastic small round cell tumor had primary abdominal involvement. In nine of these patients (mean age, 20 years)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.3.r99mr42633

    authors: Pickhardt PJ,Fisher AJ,Balfe DM,Dehner LP,Huettner PC

    更新日期:1999-03-01 00:00:00

  • Intracranial plaque enhancement in patients with cerebrovascular events on high-spatial-resolution MR images.

    abstract:PURPOSE:To characterize intracranial plaque inflammation in vivo by using three-dimensional (3D) high-spatial-resolution contrast material-enhanced black-blood (BB) magnetic resonance (MR) imaging and to investigate the relationship between intracranial plaque inflammation and cerebrovascular ischemic events. MATERIAL...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13122812

    authors: Qiao Y,Zeiler SR,Mirbagheri S,Leigh R,Urrutia V,Wityk R,Wasserman BA

    更新日期:2014-05-01 00:00:00

  • Early detection of extravasation of radiographic contrast medium. Work in progress.

    abstract::Microwave radiometry is a passive and noninvasive technique that allows quick detection of subcutaneous temperature changes. The feasibility of this technique for differentiating normal intravenous infusions of radiographic contrast medium from extravasations of contrast medium was tested in anesthetized dogs. Room-te...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.1.1609070

    authors: Shaeffer J,Sigfred SV,Sevcik MA,Grabowy RS,Gemmell LA,Hirschman AD

    更新日期:1992-07-01 00:00:00

  • Detection of unsuspected central pulmonary embolism with conventional contrast-enhanced CT.

    abstract::When fast, nondynamic scanning techniques are used in combination with adequate intravenous injection of contrast material, good-quality images of the pulmonary artery (PA) can be obtained with routine computed tomography (CT). The purpose of this study was to evaluate PA filling defects detected on these CT scans. Tw...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351360

    authors: Verschakelen JA,Vanwijck E,Bogaert J,Baert AL

    更新日期:1993-09-01 00:00:00

  • Multispectral MRI with Dual Fluorinated Probes to Track Mononuclear Cell Activity in Mice.

    abstract::Background MRI with fluorine 19 (19F) probes has shown an ability to track immune cell activity with a specific, stable, and quantitative signal. In addition, the chemical shift differences of selected 19F probes make dual-probe imaging possible. To improve 19F MRI sensitivity for dual-probe imaging, optimal fluorine ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181073

    authors: Chirizzi C,De Battista D,Tirotta I,Metrangolo P,Comi G,Bombelli FB,Chaabane L

    更新日期:2019-05-01 00:00:00

  • Mammographic parenchymal patterns and the prevalence of breast cancer.

    abstract::An investigation of the relationship between breast parenchymal patterns and breast cancer prevalence in a large referral population is presented. Mammograms were assigned to one of four categories according to our interpretation of Wolfe's classification. Cancer prevalence for the four patterns was similar when uncor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.2.387

    authors: Peyster RG,Kalisher L,Cole P

    更新日期:1977-11-01 00:00:00

  • A new radiographic sign of acute traumatic rupture of the thoracic aorta: displacement of the nasogastric tube to the right.

    abstract::Numerous plain chest radiographic signs previously described for the diagnosis of acute traumatic rupture of the thoracic aorta may be present in patients with or without such rupture. Displacement of an opaque nasogastric tube to the right (indicative of esophageal displacement) has been found to be the most reliable...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.603

    authors: Tisnado J,Tsai FY,Als A,Roach JF

    更新日期:1977-12-01 00:00:00

  • Ultrasonography of small hepatic tumors using high-resolution linear-array real-time instruments.

    abstract::Abdominal ultrasonography using a high-resolution linear-array real-time scanner was compared to computed tomography, celiac arteriography, and radionuclide imaging in 24 patients with a total of 33 hepatocellular carcinomas (HCC), 10 patients with cavernous hemangioma (12 tumors), and 2 patients with metastatic carci...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.3.6320260

    authors: Sheu JC,Sung JL,Chen DS,Yu JY,Wang TH,Su CT,Tsang YM

    更新日期:1984-03-01 00:00:00

  • Thoracic aorta: rapid black-blood MR imaging with half-Fourier rapid acquisition with relaxation enhancement with or without electrocardiographic triggering.

    abstract:PURPOSE:To evaluate and compare findings for thoracic aortic disease with three black-blood magnetic resonance (MR) pulse sequences: half-Fourier rapid acquisition with relaxation enhancement (RARE), with and without electrocardiographic (ECG) triggering, and ECG-triggered turbo spin echo (SE). MATERIALS AND METHODS:A...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.1.r99oc48185

    authors: Stemerman DH,Krinsky GA,Lee VS,Johnson G,Yang BM,Rofsky NM

    更新日期:1999-10-01 00:00:00

  • Nonalcoholic fatty liver disease: portal hypertension due to outflow block in patients without cirrhosis.

    abstract:PURPOSE:To prospectively evaluate whether the characteristics of hepatic blood flow change during the early stages of fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS:All participants provided written informed consent, and the study protocols were approved by the institutional ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132952

    authors: Hirooka M,Koizumi Y,Miyake T,Ochi H,Tokumoto Y,Tada F,Matsuura B,Abe M,Hiasa Y

    更新日期:2015-02-01 00:00:00

  • Pheochromocytoma and the normal adrenal medulla: improved visualization with I-123 MIBG scintigraphy.

    abstract::The radiopharmaceutical iodine 131 metaiodobenzylguanidine (I-131 MIBG) has been shown to locate pheochromocytomas scintigraphically with a false-negative rate of approximately 13%. To improve image quality and reduce the false-negative rate, I-123 was examined as a radioactive label for MIBG, as it has many advantage...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001380

    authors: Lynn MD,Shapiro B,Sisson JC,Beierwaltes WH,Meyers LJ,Ackerman R,Mangner TJ

    更新日期:1985-06-01 00:00:00

  • Sonographic findings in primary carcinoma of the gallbladder.

    abstract::The sonographic appearance in 4 cases of primary carcinoma of the gallbladder is correlated with the surgical and pathological findings. A fungating tumor had the greatest chance of resection, with findings dependent on the location and size of the mass. Infiltrating lesions were highly malignant. In less advanced cas...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355220

    authors: Yum HY,Fink AH

    更新日期:1980-03-01 00:00:00

  • Comparison of scanning equalization and conventional chest radiography.

    abstract::A clinical comparison study of scanning equalization radiography (SER) and conventional chest radiography was performed with the latest prototype SER system. Conventional chest radiography was performed at 120 kVp with Lanex regular screens (Eastman Kodak, Rochester, NY) and Kodak Ortho-G or Ortho-C film (Eastman Koda...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.3.2772170

    authors: Wandtke JC,Plewes DB

    更新日期:1989-09-01 00:00:00

  • Progressive diaphyseal dysplasia (Camurati-Engelmann): radiographic follow-up and CT findings.

    abstract::Sixteen patients with progressive diaphyseal dysplasia (PDD) and aged six months to 76 years were examined. Fourteen cases were hereditary, two were not. The progression of the radiologic manifestations in 13 patients who were followed up from 1 to 32 years and the computed tomography (CT) scans from five patients wer...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.3.3615880

    authors: Kaftori JK,Kleinhaus U,Naveh Y

    更新日期:1987-09-01 00:00:00

  • Neural network analysis of ventilation-perfusion lung scans.

    abstract::A neural network model was constructed to interpret ventilation-perfusion (V/Q) lung scans. This model was trained with data from 100 consecutive V/Q scans with pulmonary angiographic correlation. The network was constructed from 28 input parameters that described various standard V/Q findings, which were fed into a s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.3.8430170

    authors: Scott JA,Palmer EL

    更新日期:1993-03-01 00:00:00

  • Synthetic ossicular replacements: normal and abnormal CT appearance.

    abstract::Twenty-two patients with synthetic ossicular replacements were studied with computed tomography (CT). Twelve patients had total ossicular replacement prostheses (TORPs), and ten patients had partial ossicular replacement prostheses (PORPs). Good results were achieved in 12 patients (eight with TORPs and four with PORP...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3575730

    authors: Swartz JD,Berger AS,Zwillenberg S,Granoff DW,Popky GL

    更新日期:1987-06-01 00:00:00

  • Imaging Follow-up of Low-Risk Incidental Pancreas and Kidney Findings: Effects of Patient Age and Comorbidity on Projected Life Expectancy.

    abstract::Purpose To determine the effects of patient age and comorbidity level on life expectancy (LE) benefits associated with imaging follow-up of Bosniak IIF renal cysts and pancreatic side-branch (SB) intraductal papillary mucinous neoplasms (IPMNs). Materials and Methods A decision-analytic Markov model to evaluate LE ben...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018171701

    authors: Raphel TJ,Weaver DT,Berland LL,Herts BR,Megibow AJ,Knudsen AB,Pandharipande PV

    更新日期:2018-05-01 00:00:00

  • Gliomas: classification with MR imaging.

    abstract::The findings at magnetic resonance (MR) imaging in a group of 36 pathologically verified supratentorial gliomas were analyzed and compared with the biopsy diagnoses (a) to determine whether MR imaging could be used to classify astrocytic-series tumors into a three-tiered system of low-grade astrocytoma, anaplastic ast...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.2.2153310

    authors: Dean BL,Drayer BP,Bird CR,Flom RA,Hodak JA,Coons SW,Carey RG

    更新日期:1990-02-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic tumors against the diaphragm: frequency of diaphragmatic injury.

    abstract:PURPOSE:To retrospectively determine the frequency of diaphragmatic injury when percutaneous hepatic radiofrequency (RF) ablation is performed adjacent to the diaphragm. MATERIALS AND METHODS:Institutional Review Board approval was obtained for our HIPAA-compliant study. Informed consent for the ablation procedure and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2433060157

    authors: Head HW,Dodd GD 3rd,Dalrymple NC,Prasad SR,El-Merhi FM,Freckleton MW,Hubbard LG

    更新日期:2007-06-01 00:00:00

  • Comparison of the Reliability of Acoustic Radiation Force Impulse Imaging and Supersonic Shear Imaging in Measurement of Liver Stiffness.

    abstract:PURPOSE:To compare the reliability of acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI) in measurement of liver stiffness. MATERIALS AND METHODS:This study was approved by the institutional review board, and written informed consent was obtained for all patients. Seventy-nine patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141975

    authors: Woo H,Lee JY,Yoon JH,Kim W,Cho B,Choi BI

    更新日期:2015-12-01 00:00:00

  • Redefinitions of indications for percutaneous nephrostomy.

    abstract::An analysis of treatment response in 215 patients treated by percutaneous nephrostomy identified obstruction of the urinary tract, complicated by infection and sometimes gram-negative septicemia, as the single most important indication for this intervention. Percutaneous nephrostomy reduced the mortality from gram-neg...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.147.2.6836120

    authors: Lang EK,Price ET

    更新日期:1983-05-01 00:00:00

  • Lung lesions: correlation between viewing time and detection.

    abstract::The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seco...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.2.3336720

    authors: Oestmann JW,Greene R,Kushner DC,Bourgouin PM,Linetsky L,Llewellyn HJ

    更新日期:1988-02-01 00:00:00

  • Wooden foreign bodies in soft tissue: detection at US.

    abstract:PURPOSE:To evaluate the use of ultrasound (US) for detection of wooden foreign bodies implanted in cadaveric specimens. MATERIALS AND METHODS:Wooden foreign bodies were randomly placed in the plantar soft tissues of three cadaver feet by using 5-mm-long incisions. Ten foreign bodies were 2.5 x 1.0 mm (length x diamete...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.1.9423650

    authors: Jacobson JA,Powell A,Craig JG,Bouffard JA,van Holsbeeck MT

    更新日期:1998-01-01 00:00:00