Abstract:
PURPOSE:To compare the reliability of acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI) in measurement of liver stiffness. MATERIALS AND METHODS:This study was approved by the institutional review board, and written informed consent was obtained for all patients. Seventy-nine patients (25 healthy patients, 26 with Child-Pugh class A, and 28 with Child-Pugh class B or C) were enrolled and analyzed from April 2012 to April 2013. In each patient, three abdominal radiologists performed nine measurements of hepatic shear-wave speed with both ARFI imaging and SSI on the same day. Four weeks later, a second session was performed with the same protocol. Interobserver and intraobserver agreements were calculated by using intraclass correlation coefficients. Technical failures and measurement time were evaluated. RESULTS:There were four technical failures in the SSI group and one in the ARFI group (P = .375). The overall interobserver agreement of ARFI imaging was significantly higher than that of SSI (0.941 vs 0.828, P < .001). The overall intraobserver agreement of ARFI imaging was significantly higher than that of SSI (0.915 vs 0.829, P < .001). The overall shear-wave speed measured with SSI was higher than that measured with ARFI imaging (2.04 m/sec ± 0.88 vs 1.80 m/sec ± 0.81, P < .001). The measurement time of SSI was longer than that of ARFI imaging (310.8 seconds ± 88.5 vs 84.5 seconds ± 15.4, P < .001). CONCLUSION:ARFI imaging was more reliable than SSI in measurement of liver stiffness. The hepatic shear-wave speed measured with SSI was higher than that measured with ARFI imaging, which means that the shear-wave speeds measured with ARFI imaging and SSI cannot be used interchangeably.
journal_name
Radiologyjournal_title
Radiologyauthors
Woo H,Lee JY,Yoon JH,Kim W,Cho B,Choi BIdoi
10.1148/radiol.2015141975subject
Has Abstractpub_date
2015-12-01 00:00:00pages
881-6issue
3eissn
0033-8419issn
1527-1315journal_volume
277pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:To prospectively evaluate the outcome of patients with acute deep vein thrombosis (DVT) of the lower extremity treated with "lacing" of the thrombus with alteplase (recombinant tissue plasminogen activator, or rTPA). MATERIALS AND METHODS:This HIPAA-compliant study was approved by the Institutional Review Boar...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiol.2461062076
更新日期:2008-02-01 00:00:00
abstract:PURPOSE:To determine if a central axonal injury underlies neuropsychiatric symptoms after mild traumatic brain injury (mTBI) by using tract-based spatial statistics analysis of diffusion-tensor images. MATERIALS AND METHODS:The institutional review board approved this study, with waiver of informed consent. Diffusion-...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015142974
更新日期:2015-12-01 00:00:00
abstract::Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry [DXA], and quantitative computed tomography [CT]) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometri...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016142796
更新日期:2016-09-01 00:00:00
abstract::Human polyclonal immunoglobulin (Ig) G was attached to a monocrystalline iron oxide nanocompound (MION), a small superparamagnetic probe developed for receptor and antibody magnetic resonance (MR) imaging. The resulting complex, MION-IgG, had a slightly negative surface charge, a molecular weight of 150-180 kDa, and 0...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.1.1887040
更新日期:1991-10-01 00:00:00
abstract:PURPOSE:To perform a systematic review and meta-analysis of the diagnostic performance of computed tomography (CT) and magnetic resonance (MR) imaging as noninvasive modalities for evaluating hepatocellular carcinoma (HCC) in patients with chronic liver disease. MATERIALS AND METHODS:A search of the MEDLINE, EMBASE, a...
journal_title:Radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1148/radiol.14140690
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To determine whether polytetrafluoroethylene (PTFE) stent-grafts yield longer patency for creation or revision of transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS:Fourteen PTFE-covered Wallstents were placed in 13 patients with TIPS: seven at shunt creation and seven during revision...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.213.3.r99dc28759
更新日期:1999-12-01 00:00:00
abstract::Magnetic resonance (MR) imaging-related artifacts associated with five different aneurysm clips made of five different metals (commercially pure titanium, titanium alloy, Phynox, Elgiloy, and cobalt alloy) were evaluated. Aneurysm clips made of commercially pure titanium and titanium alloy produced the smallest artifa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.209.2.9807590
更新日期:1998-11-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the sensitivity and specificity of integrated fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) (PET/CT) for the preoperative diagnosis of mediastinal nodal metastasis in stage T1 non-small cell lung cancer (NSCLC), with surgical and h...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2412051173
更新日期:2006-11-01 00:00:00
abstract::A phase-contrast cine magnetic resonance (MR) imaging technique was used to study normal dynamics of cerebrospinal fluid (CSF) in 10 healthy volunteers and four patients with normal MR images. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle (peripheral gating). Flow encoding depicted ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.178.2.1987610
更新日期:1991-02-01 00:00:00
abstract::Pelvic sonograms from 61 consecutive patients with suspected ectopic pregnancy and an additional 17 proved ectopic pregnancy cases were reviewed retrospectively. Special attention was given to the appearance of the uterus and intrauterine fluid collections in the absence of a fetal pole. Criteria for the exclusion of ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.143.1.7063730
更新日期:1982-04-01 00:00:00
abstract:PURPOSE:To correlate upper gastrointestinal study findings of the position of the duodenum and duodenal-jejunal junction in children after liver transplantation with transplant type, age at transplantation, indication for transplantation, and history of surgery or malrotation. MATERIALS AND METHODS:Upper gastrointesti...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.207.1.9530320
更新日期:1998-04-01 00:00:00
abstract::Ten patients with presacral tumors proved by histologic and computed-tomographic investigations underwent ultrasound scanning. The sound beam was directed through the ischial foramen along longitudinal, transverse, and oblique planes. Nine of 10 tumors localized in the sacral fossa were identified sonographically. In ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.2.6836140
更新日期:1983-05-01 00:00:00
abstract:PURPOSE:To determine whether the addition of color Doppler ultrasonography (US) to gray-scale US can help diagnose appendicitis in children. MATERIALS AND METHODS:One hundred children with suspected appendicitis were evaluated with gray-scale and color Doppler US scanning. Color Doppler US scans were considered positi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.2.8153340
更新日期:1994-05-01 00:00:00
abstract:PURPOSE:To determine the time course of enhancement patterns in the aorta and endoleaks at dynamic computed tomographic (CT) angiography as well as their effect on the endoleak detection rate in patients who have undergone abdominal aortic endovascular aneurysm repair (EVAR). MATERIALS AND METHODS:This retrospective s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13120197
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:To evaluate in a pilot study the feasibility and efficacy of endovascular brachytherapy for prophylaxis of restenosis after femoropopliteal percutaneous transluminal angioplasty (PTA) without stent implantation in a group of patients with a high risk of restenosis. MATERIALS AND METHODS:Ten patients (six women...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.208.1.9646810
更新日期:1998-07-01 00:00:00
abstract::To assess the potential role of ultrasound (US) in evaluating transjugularly inserted intrahepatic portosystemic shunts, the authors performed sonographic, including duplex and color Doppler, studies in 23 patients. Imaging was performed before, during the first week after, and 2-3 months after shunt placement. The pr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.186.2.8421760
更新日期:1993-02-01 00:00:00
abstract::In an azotemic patient with suspected renal artery stenosis, undiluted gadopentetate dimeglumine was administered in an aortic bolus to provide contrast at digital subtraction angiography of the aorta and renal arteries. The contrast material (5 mmol/mL) was power injected (rate, 15 mL/sec; total dose, 30 mL). Selecti...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.201.2.8888260
更新日期:1996-11-01 00:00:00
abstract::Background Previous studies have suggested that texture analysis is a promising tool in the diagnosis, characterization, and assessment of treatment response in various cancer types. Therefore, application of texture analysis may be helpful for early prediction of pathologic response in breast cancer. Purpose To inves...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019182718
更新日期:2020-01-01 00:00:00
abstract::The effects of 30-minute intravenous and superior mesenteric artery (SMA) infusions of vasopressin in dosages of 2.75 mU and 14 mU per min per kg were compared in five dogs that had cirrhosis and portal hypertension induced by fractionated intraportal polyvinyl alcohol injections. A reduction in portal pressure of app...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.142.3.6977790
更新日期:1982-03-01 00:00:00
abstract::A basic understanding of shock wave generation is essential for the radiologist who performs gallstone lithotripsy. Shock waves differ from ordinary acoustic waves in that they have a rapid rise time, a positive pressure component that gives rise to compressive forces approaching 1,000 atm, and a low-amplitude sustain...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.178.2.1987600
更新日期:1991-02-01 00:00:00
abstract::Effective health care delivery systems rely heavily on high degrees of skill in professionalism and communication. These skills are essential to all of the missions of a successful radiology department. Until recently, there was a lack of emphasis on the importance of these issues and a lack of efforts in setting expe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2383041849
更新日期:2006-03-01 00:00:00
abstract::Images from endoscopic retrograde pancreatography performed in 38 patients with cystic pancreatic neoplasms were reviewed to determine whether they might allow differentiation of malignant from benign lesions. Twenty-three patients had histologically proved benign lesions; 15 had frankly malignant lesions. Images were...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.3.8394590
更新日期:1993-09-01 00:00:00
abstract::In real-time ultrasound examinations of six women, jets of urine were noted to enter the bladder during the filling phase. The jets appeared at irregular intervals, and each jet lasted from a fraction of a second up to three seconds. The ureters functioned independently of each other. The flow characteristics of the u...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.140.2.7255730
更新日期:1981-08-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the influence of postbiopsy hemorrhage on the accuracy of tumor detection at T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and diffusion-weighted (DW) MR imaging of prostate cancer, with histologic findings as the reference standard. MAT...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2482070157
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the safety and efficacy of percutaneous image-guided laser photocoagulation for the treatment of spinal osteoid osteoma (OO) in proximity to neural structures. MATERIALS AND METHODS:This study was institutional review board-approved with waivers of informed consent. From January 199...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015150491
更新日期:2016-03-01 00:00:00
abstract::Radiographic findings in 11 proved cases of cytomegalovirus (CMV) colitis were reviewed and correlated with colonoscopic and pathologic findings. Patients were chronically ill homosexual men with multiple systemic opportunistic infections. Endoscopies showed focal or diffuse inflammation, hemorrhagic plaques, and supe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.2988010
更新日期:1985-06-01 00:00:00
abstract::Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional re...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161603
更新日期:2017-07-01 00:00:00
abstract::To investigate spatial resolution requirements for digitized portal images in radiation therapy, observer performance tests were performed. One hundred twenty portal images were digitized with sampling frequencies of 0.700, 0.350, and 0.175 mm for observation. Receiver operating characteristic analysis was used to det...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.2.1561370
更新日期:1992-05-01 00:00:00
abstract::Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left cor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.3.3517950
更新日期:1986-06-01 00:00:00
abstract::Purpose To assess the performance of computer-aided diagnosis (CAD) systems and to determine the dominant ultrasonographic (US) features when classifying benign versus malignant focal liver lesions (FLLs) by using contrast material-enhanced US cine clips. Materials and Methods One hundred six US data sets in all subje...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017170365
更新日期:2018-03-01 00:00:00