Abstract:
PURPOSE:Planning osteotomies is a task that surgeons do as part of standard surgical workflow. This task, however, becomes more difficult and less intuitive when a robot is tasked with performing the osteotomy. In this study, we aim to provide a new method for surgeons to allow for highly intuitive trajectory planning, similar to the way an attending surgeon would instruct a junior. METHODS:Planning an osteotomy, especially during a craniotomy, is performed intraoperatively using a sterile surgical pen or pencil directly on the exposed bone surface. This paper presents a new method for generating osteotomy trajectories for a multi-DOF robotic manipulator using the same method and relaying the penscribed cut path to the manipulator as a three-dimensional trajectory. The penscribed cut path is acquired using structured light imaging, and detection, segmentation, optimization and orientation generation of the Cartesian trajectory are done autonomously after minimal user input. RESULTS:A 7-DOF manipulator (KUKA IIWA) is able to follow fully penscribed trajectories with sub-millimeter accuracy in the target plane and perpendicular to it (0.46 mm and 0.36 mm absolute mean error, respectively). CONCLUSIONS:The robot is able to precisely follow cut paths drawn by the surgeon directly onto the exposed boney surface of the skull. We demonstrate through this study that current surgical workflow does not have to be drastically modified to introduce robotic technology in the operating room. We show that it is possible to guide a robot to perform an osteotomy in much the same way a senior surgeon would show a trainee by using a simple surgical pen or pencil.
journal_name
Int J Comput Assist Radiol Surgauthors
Jivraj J,Deorajh R,Lai P,Chen C,Nguyen N,Ramjist J,Yang VXDdoi
10.1007/s11548-018-01905-xsubject
Has Abstractpub_date
2019-05-01 00:00:00pages
809-818issue
5eissn
1861-6410issn
1861-6429pii
10.1007/s11548-018-01905-xjournal_volume
14pub_type
杂志文章abstract:PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficien...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1380-9
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1421-4
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:In image-guided surgery for glioma removal, neurosurgeons usually plan the resection on images acquired before surgery and use them for guidance during the subsequent intervention. However, after the surgical procedure has begun, the preplanning images become unreliable due to the brain shift phenomenon, caused...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02045-6
更新日期:2019-10-01 00:00:00
abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0964-x
更新日期:2014-07-01 00:00:00
abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0282-5
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:Ultrasound acquisitions are typically affected by deformations due to the pressure applied onto the contact surface. While a certain amount of pressure is necessary to ensure good acoustic coupling and visibility of the anatomy under examination, the caused deformations hinder accurate localization and geometri...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1716-8
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view ima...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02229-5
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and ste...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1777-8
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01926-0
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:The objective of this work is to develop a preoperative reconstruction plate design system for unilateral pelvic and acetabular fracture reduction and internal fixation surgery, using computer graphics and augmented reality (AR) techniques, in order to respect the patient-specific morphology and to reduce surgi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0775-5
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In this paper, we aimed to develop a fully integrated CAD system for automated detection of p...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1521-9
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVE:The goal of this study is to investigate automatic myocardium tracking in cardiac Magnetic Resonance (MR) sequences using global distribution matching via level-set curve evolution. Rather than relying on the pixelwise information as in existing approaches, distribution matching compares intensity distributio...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-008-0265-y
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0957-9
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1590-9
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0997-9
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1803-x
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Medical imaging and in particular digital radiographic images offer a great deal of information to dentists in the clinical diagnosis and treatment processes on a daily basis. This paper presents a new method aimed to produce an accurate segmentation of dental implants and the crestal bone line in radiographic ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0802-6
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-01911-z
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:Over the last decade, the demand for content management of video recordings of surgical procedures has greatly increased. Although a few research methods have been published toward this direction, the related literature is still in its infancy. In this paper, we address the problem of shot detection in endoscop...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1431-2
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:The favored treatment for many hip fractures is a sliding hip screw, and its usage is expected to increase in the future. Failures can be reduced, and complications detected earlier by semi-automated CT image analysis. The most frequent failure is due to the screw cut-out from the femoral head. METHODS:An imag...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0498-4
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of differen...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02262-4
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1113-x
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0690-9
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:In the last decade, there has been a great effort to bring mixed reality (MR) into the operating room to assist surgeons intraoperatively. However, progress towards this goal is still at an early stage. The aim of this paper is to propose a MR visualisation platform which projects multiple imaging modalities to...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02165-4
更新日期:2020-05-01 00:00:00
abstract:PURPOSE:Most software systems for oral implantology are based on a two-dimensional multi-view approach, often accompanied with a surface rendered model. Usually they are affected by common errors like anisotropy of the volume and distortion on measurements. A more integrated and realistic 3D approach for implant surger...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0394-y
更新日期:2010-01-01 00:00:00
abstract:PURPOSE: Most of the current Bonebridge surgeries undergo preoperative simulation planning in a computer. However, surgeons usually use the landmarks on the bone surface to determine the location where to implant the device, using the simulation image in the computer only as a reference (conventional method). We deve...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0973-9
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1759-x
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:We present a platform, GRAphical Pipeline Environment (GRAPE), to facilitate the development of patient-adaptive magnetic resonance imaging (MRI) protocols. METHODS:GRAPE is an open-source project implemented in the Qt C++ framework to enable graphical creation, execution, and debugging of real-time image anal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1495-z
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:To support preoperative planning of bone drilling for Microendoscopic Discectomy, we present a set of interactive bone-drilling methods using a general 2D pointing device. METHODS:Unlike the existing methods, our framework has the following features: (1) the user can directly cut away arbitrary 3D regions on t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0413-z
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Tele-operation of robotic surgery reduces the radiation exposure during the interventional radiological operations. However, endoscope vision without force feedback on the surgical tool increases the difficulty for precise manipulation and the risk of tissue damage. The shared control of vision and force provid...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1425-0
更新日期:2017-01-01 00:00:00