Hybrid simulation using mixed reality for interventional ultrasound imaging training.

Abstract:

PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on mixed reality was designed, implemented and tested for hand-eye coordination training in diagnostic and interventional US. METHODS:A hybrid simulator was developed integrating a physical US phantom and a software application with a 3D virtual scene. In this scene, a 3D model of the probe with its relative scan plane is coherently displayed with a 3D representation of the phantom internal structures. An evaluation study of the diagnostic module was performed by recruiting thirty-six novices and four experts. The performances of the hybrid (HG) versus physical (PG) simulator were compared. After the training session, each novice was required to visualize a particular target structure. The four experts completed a 5-point Likert scale questionnaire. RESULTS:Seventy-eight percentage of the HG novices successfully visualized the target structure, whereas only 45% of the PG reached this goal. The mean scores from the questionnaires were 5.00 for usefulness, 4.25 for ease of use, 4.75 for 3D perception, and 3.25 for phantom realism. CONCLUSIONS:The hybrid US training simulator provides ease of use and is effective as a hand-eye coordination teaching tool. Mixed reality can improve US probe manipulation training.

authors

Freschi C,Parrini S,Dinelli N,Ferrari M,Ferrari V

doi

10.1007/s11548-014-1113-x

subject

Has Abstract

pub_date

2015-07-01 00:00:00

pages

1109-15

issue

7

eissn

1861-6410

issn

1861-6429

journal_volume

10

pub_type

杂志文章
  • Knee arthroscopic navigation using virtual-vision rendering and self-positioning technology.

    abstract:PURPOSE:Knee arthroscopy suffers from a lack of depth information and easy occlusion of the visual field. To solve these limitations, we propose an arthroscopic navigation system based on self-positioning technology, with the guidance of virtual-vision views. This system can work without any external tracking devices o...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02099-6

    authors: Ma C,Cui X,Chen F,Ma L,Xin S,Liao H

    更新日期:2020-03-01 00:00:00

  • Spine labeling in MRI via regularized distribution matching.

    abstract:PURPOSE:This study investigates an efficient (nearly real-time) two-stage spine labeling algorithm that removes the need for an external training while being applicable to different types of MRI data and acquisition protocols. METHODS:Based solely on the image being labeled (i.e., we do not use training data), the fir...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1651-0

    authors: Hojjat SP,Ayed I,Garvin GJ,Punithakumar K

    更新日期:2017-11-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

    abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1347-2

    authors: Wang X,Habert S,Ma M,Huang CH,Fallavollita P,Navab N

    更新日期:2016-08-01 00:00:00

  • Design considerations for a novel MRI compatible manipulator for prostate cryoablation.

    abstract:PURPOSE:Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0558-4

    authors: Abdelaziz S,Esteveny L,Renaud P,Bayle B,Barbé L,De Mathelin M,Gangi A

    更新日期:2011-11-01 00:00:00

  • Cost-effective, personalized, 3D-printed liver model for preoperative planning before laparoscopic liver hemihepatectomy for colorectal cancer metastases.

    abstract:PURPOSE:Three-dimensional (3D) printing for preoperative planning has been intensively developed in the recent years. However, the implementation of these solutions in hospitals is still difficult due to high costs, extremely expensive industrial-grade printers, and software that is difficult to obtain and learn along ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1527-3

    authors: Witowski JS,Pędziwiatr M,Major P,Budzyński A

    更新日期:2017-12-01 00:00:00

  • Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks.

    abstract:PURPOSE:In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to rea...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01965-7

    authors: Pfeiffer M,Riediger C,Weitz J,Speidel S

    更新日期:2019-07-01 00:00:00

  • MINARO HD: control and evaluation of a handheld, highly dynamic surgical robot.

    abstract:PURPOSE:Current surgical robotic systems are either large serial arms, resulting in higher risks due to their high inertia and no inherent limitations of the working space, or they are bone-mounted, adding substantial additional task steps to the surgical workflow. The robot presented in this paper has a handy and ligh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02306-9

    authors: Vossel M,Müller M,Niesche A,Theisgen L,Radermacher K,de la Fuente M

    更新日期:2021-01-23 00:00:00

  • Detection and modelling of contacts in explicit finite-element simulation of soft tissue biomechanics.

    abstract:PURPOSE:Realistic modelling of soft tissue biomechanics and mechanical interactions between tissues is an important part of biomechanically-informed surgical image-guidance and surgical simulation. This submission details a contact-modelling pipeline suitable for implementation in explicit matrix-free FEM solvers. Whil...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1142-5

    authors: Johnsen SF,Taylor ZA,Han L,Hu Y,Clarkson MJ,Hawkes DJ,Ourselin S

    更新日期:2015-11-01 00:00:00

  • Interactive navigation of segmented MR angiograms using simultaneous curved planar and volume visualizations.

    abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0534-4

    authors: van Schooten BW,van Dijk EM,Suinesiaputra A,Reiber JH

    更新日期:2011-09-01 00:00:00

  • System events: readily accessible features for surgical phase detection.

    abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1409-0

    authors: Malpani A,Lea C,Chen CC,Hager GD

    更新日期:2016-06-01 00:00:00

  • Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

    abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0921-8

    authors: Qian K,Ando T,Nakamura K,Liao H,Kobayashi E,Yahagi N,Sakuma I

    更新日期:2014-03-01 00:00:00

  • Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis.

    abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0976-1

    authors: Krüger J,Ehrhardt J,Bischof A,Handels H

    更新日期:2014-05-01 00:00:00

  • Interactive determination of robust safety margins for oncologic liver surgery.

    abstract:OBJECTIVE:Complex oncologic interventions in the liver require an extensive and careful preoperative analysis. Particularly the achievement of an optimal safety margin around tumors remains a difficult task for surgeons. METHODS:We present new methods for evaluating different safety margins and their effect on the ass...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0359-1

    authors: Hansen C,Zidowitz S,Hindennach M,Schenk A,Hahn H,Peitgen HO

    更新日期:2009-09-01 00:00:00

  • Fast, robust, and accurate monocular peer-to-peer tracking for surgical navigation.

    abstract:PURPOSE:This work presents a new monocular peer-to-peer tracking concept overcoming the distinction between tracking tools and tracked tools for optical navigation systems. A marker model concept based on marker triplets combined with a fast and robust algorithm for assigning image feature points to the corresponding m...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02111-z

    authors: Strzeletz S,Hazubski S,Moctezuma JL,Hoppe H

    更新日期:2020-03-01 00:00:00

  • Accuracy analysis in MRI-guided robotic prostate biopsy.

    abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0831-9

    authors: Xu H,Lasso A,Guion P,Krieger A,Kaushal A,Singh AK,Pinto PA,Coleman J,Grubb RL 3rd,Lattouf JB,Menard C,Whitcomb LL,Fichtinger G

    更新日期:2013-11-01 00:00:00

  • Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions.

    abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02029-6

    authors: de Jong TL,Moelker A,Dankelman J,van den Dobbelsteen JJ

    更新日期:2019-12-01 00:00:00

  • Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study.

    abstract:PURPOSE:To perform bronchoscopy safely and smoothly, it is very important to develop a bronchoscopic guidance system. Transbronchial lung biopsy (TBLB) with a bronchoscopic guidance system especially should permit safe image-guided procedures. Recently, electromagnetic tracking (EMT) is utilized to track the tip of the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0626-9

    authors: Deguchi D,Feuerstein M,Kitasaka T,Suenaga Y,Ide I,Murase H,Imaizumi K,Hasegawa Y,Mori K

    更新日期:2012-05-01 00:00:00

  • Automated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI.

    abstract:PURPOSE:We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). METHODS:The method is based on superpixel technique and classification of each supe...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1483-3

    authors: Soltaninejad M,Yang G,Lambrou T,Allinson N,Jones TL,Barrick TR,Howe FA,Ye X

    更新日期:2017-02-01 00:00:00

  • Force estimation from OCT volumes using 3D CNNs.

    abstract:PURPOSE:Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and ste...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1777-8

    authors: Gessert N,Beringhoff J,Otte C,Schlaefer A

    更新日期:2018-07-01 00:00:00

  • A gesture-controlled projection display for CT-guided interventions.

    abstract:PURPOSE:The interaction with interventional imaging systems within a sterile environment is a challenging task for physicians. Direct physician-machine interaction during an intervention is rather limited because of sterility and workspace restrictions. METHODS:We present a gesture-controlled projection display that e...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1215-0

    authors: Mewes A,Saalfeld P,Riabikin O,Skalej M,Hansen C

    更新日期:2016-01-01 00:00:00

  • MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

    abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0964-x

    authors: Yiallouras C,Mylonas N,Damianou C

    更新日期:2014-07-01 00:00:00

  • A deep learning framework for efficient analysis of breast volume and fibroglandular tissue using MR data with strong artifacts.

    abstract:PURPOSE:The main purpose of this work is to develop, apply, and evaluate an efficient approach for breast density estimation in magnetic resonance imaging data, which contain strong artifacts including intensity inhomogeneities. METHODS:We present a pipeline for breast density estimation, which consists of intensity i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01928-y

    authors: Ivanovska T,Jentschke TG,Daboul A,Hegenscheid K,Völzke H,Wörgötter F

    更新日期:2019-10-01 00:00:00

  • [¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

    abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1260-8

    authors: Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

    更新日期:2016-05-01 00:00:00

  • Orbital volume analysis: validation of a semi-automatic software segmentation method.

    abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1254-6

    authors: Jansen J,Schreurs R,Dubois L,Maal TJ,Gooris PJ,Becking AG

    更新日期:2016-01-01 00:00:00

  • Articular surface remodeling of the hip after periacetabular osteotomy.

    abstract:PURPOSE:Periacetabular osteotomies are a family of surgical procedures used to treat hip dysplasia. In a periacetabular osteotomy, the operating surgeon aims to increase acetabular coverage of the femoral head. The surgical correction has mechanical goals of increasing the stability of the joint and to improving the pr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0641-x

    authors: Rasquinha BJ,Sayani J,Rudan JF,Wood GC,Ellis RE

    更新日期:2012-03-01 00:00:00

  • Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    abstract:PURPOSE:Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermog...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1683-5

    authors: Rathmann P,Chalopin C,Halama D,Giri P,Meixensberger J,Lindner D

    更新日期:2018-03-01 00:00:00

  • Robotic ultrasound-guided facet joint insertion.

    abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1759-x

    authors: Esteban J,Simson W,Requena Witzig S,Rienmüller A,Virga S,Frisch B,Zettinig O,Sakara D,Ryang YM,Navab N,Hennersperger C

    更新日期:2018-06-01 00:00:00

  • Automatic bone segmentation in whole-body CT images.

    abstract:PURPOSE:Many diagnostic or treatment planning applications critically depend on the successful localization of bony structures in CT images. Manual or semiautomatic bone segmentation is tedious, however, and often not practical in clinical routine. In this paper, we present a reliable and fully automatic bone segmentat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1883-7

    authors: Klein A,Warszawski J,Hillengaß J,Maier-Hein KH

    更新日期:2019-01-01 00:00:00

  • A visual odometry base-tracking system for intraoperative C-arm guidance.

    abstract:PURPOSE:C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view ima...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02229-5

    authors: Haliburton L,Esfandiari H,Guy P,Anglin C,Hodgson A

    更新日期:2020-10-01 00:00:00