Average sound speed estimation using speckle analysis of medical ultrasound data.

Abstract:

PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is important for improving positioning accuracy and focus quality of ultrasound image. METHOD:A novel method using speckle analysis of ultrasound image is proposed for average sound speed estimation. Firstly, dynamic receive beam forming technology is employed to form ultrasound images. These ultrasound images are formed by same pre-beam formed radio frequency data but using different assumed sound speeds. Secondly, an improved speckle analysis method is proposed to evaluate focus quality of these ultrasound images. Thirdly, an iteration strategy is employed to locate the desired sound speed that corresponds to the best focus quality image. RESULTS:For quantitative evaluation, a group of ultrasound data with 20 different structure patterns is simulated. The comparison of estimated and simulated sound speeds shows speed estimation errors to be -0.7 ± 2.54 m/s and -1.30 ± 5.15 m/s for ultrasound data obtained by 128- and 64-active individual elements linear arrays, respectively. Furthermore, we validate our method via phantom experiments. The sound speed estimation error is -1.52 ± 8.81 m/s. CONCLUSION:Quantitative evaluation proves that proposed method can estimate average sound speed accurately using single transducer with single scan.

authors

Qu X,Azuma T,Liang JT,Nakajima Y

doi

10.1007/s11548-012-0690-9

subject

Has Abstract

pub_date

2012-11-01 00:00:00

pages

891-9

issue

6

eissn

1861-6410

issn

1861-6429

journal_volume

7

pub_type

杂志文章
  • Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

    abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0548-6

    authors: Weil YA,Liebergall M,Mosheiff R,Singer SB,Joskowicz L,Khoury A

    更新日期:2011-09-01 00:00:00

  • MIDG-Emerging grid technologies for multi-site preclinical molecular imaging research communities.

    abstract:PURPOSE:Molecular imaging is the visualization and identification of specific molecules in anatomy for insight into metabolic pathways, tissue consistency, and tracing of solute transport mechanisms. This paper presents the Molecular Imaging Data Grid (MIDG) which utilizes emerging grid technologies in preclinical mole...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0524-6

    authors: Lee J,Documet J,Liu B,Park R,Tank A,Huang HK

    更新日期:2011-03-01 00:00:00

  • Suspension laryngoscopy using a curved-frame trans-oral robotic system.

    abstract:PURPOSE:Suspension laryngoscopy has been employed for laryngeal diseases such as treatment for a polyp, cystoma, or granuloma. After securing a straight path with a laryngoscope, the surgeon inserts rigid instruments and examines the target lesion by using a microscope. However, many patients suffer from secondary comp...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0944-1

    authors: Kwon YS,Tae K,Yi BJ

    更新日期:2014-07-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions.

    abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02029-6

    authors: de Jong TL,Moelker A,Dankelman J,van den Dobbelsteen JJ

    更新日期:2019-12-01 00:00:00

  • Shot boundary detection in endoscopic surgery videos using a variational Bayesian framework.

    abstract:PURPOSE:Over the last decade, the demand for content management of video recordings of surgical procedures has greatly increased. Although a few research methods have been published toward this direction, the related literature is still in its infancy. In this paper, we address the problem of shot detection in endoscop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1431-2

    authors: Loukas C,Nikiteas N,Schizas D,Georgiou E

    更新日期:2016-11-01 00:00:00

  • A pre-operative planning framework for global registration of laparoscopic ultrasound to CT images.

    abstract:PURPOSE:Laparoscopic ultrasound (LUS) enhances the safety of laparoscopic liver resection by enabling real-time imaging of internal structures such as vessels. However, LUS probes can be difficult to use, and many tumours are iso-echoic and hence are not visible. Registration of LUS to a pre-operative CT or MR scan has...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1799-2

    authors: Ramalhinho J,Robu MR,Thompson S,Gurusamy K,Davidson B,Hawkes D,Barratt D,Clarkson MJ

    更新日期:2018-08-01 00:00:00

  • Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy.

    abstract:PURPOSE:Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we pro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02181-4

    authors: Kalia M,Mathur P,Tsang K,Black P,Navab N,Salcudean S

    更新日期:2020-07-01 00:00:00

  • Dual-robot ultrasound-guided needle placement: closing the planning-imaging-action loop.

    abstract:PURPOSE:Precise needle placement is an important task during several medical procedures. Ultrasound imaging is often used to guide the needle toward the target region in soft tissue. This task remains challenging due to the user's dependence on image quality, limited field of view, moving target, and moving needle. In ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1408-1

    authors: Kojcev R,Fuerst B,Zettinig O,Fotouhi J,Lee SC,Frisch B,Taylor R,Sinibaldi E,Navab N

    更新日期:2016-06-01 00:00:00

  • Patient-specific estimation of detailed cochlear shape from clinical CT images.

    abstract:PURPOSE:A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detai...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1701-7

    authors: Kjer HM,Fagertun J,Wimmer W,Gerber N,Vera S,Barazzetti L,Mangado N,Ceresa M,Piella G,Stark T,Stauber M,Reyes M,Weber S,Caversaccio M,González Ballester MÁ,Paulsen RR

    更新日期:2018-03-01 00:00:00

  • Use the force: deformation correction in robotic 3D ultrasound.

    abstract:PURPOSE:Ultrasound acquisitions are typically affected by deformations due to the pressure applied onto the contact surface. While a certain amount of pressure is necessary to ensure good acoustic coupling and visibility of the anatomy under examination, the caused deformations hinder accurate localization and geometri...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1716-8

    authors: Virga S,Göbl R,Baust M,Navab N,Hennersperger C

    更新日期:2018-05-01 00:00:00

  • Four-dimensional fully convolutional residual network-based liver segmentation in Gd-EOB-DTPA-enhanced MRI.

    abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01935-z

    authors: Takenaga T,Hanaoka S,Nomura Y,Nemoto M,Murata M,Nakao T,Miki S,Yoshikawa T,Hayashi N,Abe O

    更新日期:2019-08-01 00:00:00

  • Breast masses detection using phase portrait analysis and fuzzy inference systems.

    abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0659-0

    authors: Mencattini A,Salmeri M

    更新日期:2012-07-01 00:00:00

  • Correction to: Automated measurement of bone scan index from a whole-body bone scintigram.

    abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 已发布勘误

    doi:10.1007/s11548-020-02119-w

    authors: Shimizu A,Wakabayashi H,Kanamori T,Saito A,Nishikawa K,Daisaki H,Higashiyama S,Kawabe J

    更新日期:2020-03-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • Automated muscle segmentation from CT images of the hip and thigh using a hierarchical multi-atlas method.

    abstract:PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1758-y

    authors: Yokota F,Otake Y,Takao M,Ogawa T,Okada T,Sugano N,Sato Y

    更新日期:2018-07-01 00:00:00

  • Interactive determination of robust safety margins for oncologic liver surgery.

    abstract:OBJECTIVE:Complex oncologic interventions in the liver require an extensive and careful preoperative analysis. Particularly the achievement of an optimal safety margin around tumors remains a difficult task for surgeons. METHODS:We present new methods for evaluating different safety margins and their effect on the ass...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0359-1

    authors: Hansen C,Zidowitz S,Hindennach M,Schenk A,Hahn H,Peitgen HO

    更新日期:2009-09-01 00:00:00

  • Anatomy-driven multiple trajectory planning (ADMTP) of intracranial electrodes for epilepsy surgery.

    abstract:PURPOSE:Epilepsy is potentially curable with resective surgery if the epileptogenic zone (EZ) can be identified. If non-invasive imaging is unable to elucidate the EZ, intracranial electrodes may be implanted to identify the EZ as well as map cortical function. In current clinical practice, each electrode trajectory is...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1628-z

    authors: Sparks R,Vakharia V,Rodionov R,Vos SB,Diehl B,Wehner T,Miserocchi A,McEvoy AW,Duncan JS,Ourselin S

    更新日期:2017-08-01 00:00:00

  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • A projected landmark method for reduction of registration error in image-guided surgery systems.

    abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1075-z

    authors: Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SM

    更新日期:2015-05-01 00:00:00

  • Patch-based classification of gallbladder wall vascularity from laparoscopic images using deep learning.

    abstract:PURPOSE:In this study, we propose a deep learning approach for assessment of gallbladder (GB) wall vascularity from images of laparoscopic cholecystectomy (LC). Difficulty in the visualization of GB wall vessels may be the result of fatty infiltration or increased thickening of the GB wall, potentially as a result of c...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02285-x

    authors: Loukas C,Frountzas M,Schizas D

    更新日期:2021-01-01 00:00:00

  • Incorporating prior shape knowledge via data-driven loss model to improve 3D liver segmentation in deep CNNs.

    abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02085-y

    authors: Mohagheghi S,Foruzan AH

    更新日期:2020-02-01 00:00:00

  • A dataset of laryngeal endoscopic images with comparative study on convolution neural network-based semantic segmentation.

    abstract:PURPOSE:Automated segmentation of anatomical structures in medical image analysis is a prerequisite for autonomous diagnosis as well as various computer- and robot-aided interventions. Recent methods based on deep convolutional neural networks (CNN) have outperformed former heuristic methods. However, those methods wer...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01910-0

    authors: Laves MH,Bicker J,Kahrs LA,Ortmaier T

    更新日期:2019-03-01 00:00:00

  • Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study.

    abstract:PURPOSE:Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0997-9

    authors: Kobler JP,Schoppe M,Lexow GJ,Rau TS,Majdani O,Kahrs LA,Ortmaier T

    更新日期:2014-11-01 00:00:00

  • Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1740-8

    authors: Granados A,Vakharia V,Rodionov R,Schweiger M,Vos SB,O'Keeffe AG,Li K,Wu C,Miserocchi A,McEvoy AW,Clarkson MJ,Duncan JS,Sparks R,Ourselin S

    更新日期:2018-06-01 00:00:00

  • Meaningful Assessment of Robotic Surgical Style using the Wisdom of Crowds.

    abstract:OBJECTIVE:Quantitative assessment of surgical skills is an important aspect of surgical training; however, the proposed metrics are sometimes difficult to interpret and may not capture the stylistic characteristics that define expertise. This study proposes a methodology for evaluating the surgical skill, based on metr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1738-2

    authors: Ershad M,Rege R,Fey AM

    更新日期:2018-07-01 00:00:00

  • [¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

    abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1260-8

    authors: Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

    更新日期:2016-05-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • Automated pulmonary nodule CT image characterization in lung cancer screening.

    abstract:PURPOSE:In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malign...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1245-7

    authors: Reeves AP,Xie Y,Jirapatnakul A

    更新日期:2016-01-01 00:00:00

  • Ultrasound thermal monitoring with an external ultrasound source for customized bipolar RF ablation shapes.

    abstract:PURPOSE:Thermotherapy is a clinical procedure which delivers thermal energy to a target, and it has been applied for various medical treatments. Temperature monitoring during thermotherapy is important to achieve precise and reproducible results. Medical ultrasound can be used for thermal monitoring and is an attractiv...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1744-4

    authors: Kim Y,Audigier C,Ziegle J,Friebe M,Boctor EM

    更新日期:2018-06-01 00:00:00