[¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

Abstract:

PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' left hindlimb by electrostimulation of the Vastus Lateralis muscle motor point. After 15 min of muscle contractions, [[Formula: see text]]acetate was injected and PET/CT of both hindlimbs was acquired. The resting hindlimb was used as a control reference. The kinetic parameters [Formula: see text] and [Formula: see text] were calculated for the target muscles (exercised and control) and correlated with the corresponding standardized uptake values (SUVs). The ratio between each kinetic parameter values and the SUV extracted for the exercised muscle and the muscle at rest was computed ([Formula: see text] and [Formula: see text], respectively). RESULTS:Kinetic analysis quantitatively confirmed that net tracer uptake ([Formula: see text]) and washout ([Formula: see text]) were significantly higher in exercised muscles ([Formula: see text] for exercised muscles vs. [Formula: see text] for resting muscles, [Formula: see text]; [Formula: see text] for exercised muscle vs. [Formula: see text] for resting muscle, [Formula: see text]). On the other hand, SUV was not significantly different between active and inactive muscles ([Formula: see text] for exercised muscles vs. [Formula: see text] for resting muscles). Linear regression analysis revealed a good correlation ([Formula: see text]) between net tracer uptake ratio ([Formula: see text]) and the SUV ratio [Formula: see text]). A lower correlation was found between the net tracer washout ratio ([Formula: see text]) and the SUV ratio ([Formula: see text]). CONCLUSION:The present study showed that kinetic modelling can detect changes between active and inactive skeletal muscles with a higher sensitivity with respect to the SUV, when performed with [[Formula: see text]]acetate PET/CT.

authors

Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

doi

10.1007/s11548-015-1260-8

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

733-43

issue

5

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-015-1260-8

journal_volume

11

pub_type

杂志文章
  • Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

    abstract:PURPOSE:Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1556-y

    authors: Hacihaliloglu I

    更新日期:2017-06-01 00:00:00

  • Predicting surgical skill from the first N seconds of a task: value over task time using the isogony principle.

    abstract:PURPOSE:Most evaluations of surgical workflow or surgeon skill use simple, descriptive statistics (e.g., time) across whole procedures, thereby deemphasizing critical steps and potentially obscuring critical inefficiencies or skill deficiencies. In this work, we examine off-line, temporal clustering methods that chunk ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1606-5

    authors: French A,Lendvay TS,Sweet RM,Kowalewski TM

    更新日期:2017-07-01 00:00:00

  • Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.

    abstract:PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficien...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1380-9

    authors: Mayer A,Zholkover A,Portnoy O,Raviv G,Konen E,Symon Z

    更新日期:2016-06-01 00:00:00

  • Automatic abdominal multi-organ segmentation using deep convolutional neural network and time-implicit level sets.

    abstract:PURPOSE:Multi-organ segmentation from CT images is an essential step for computer-aided diagnosis and surgery planning. However, manual delineation of the organs by radiologists is tedious, time-consuming and poorly reproducible. Therefore, we propose a fully automatic method for the segmentation of multiple organs fro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1501-5

    authors: Hu P,Wu F,Peng J,Bao Y,Chen F,Kong D

    更新日期:2017-03-01 00:00:00

  • Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

    abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1538-0

    authors: Li M,Castillo SJ,Castillo R,Castillo E,Guerrero T,Xiao L,Zheng X

    更新日期:2017-09-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0957-9

    authors: Amiri S,Wilson DR,Masri BA,Anglin C

    更新日期:2014-07-01 00:00:00

  • Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis.

    abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0976-1

    authors: Krüger J,Ehrhardt J,Bischof A,Handels H

    更新日期:2014-05-01 00:00:00

  • A practical marker-less image registration method for augmented reality oral and maxillofacial surgery.

    abstract:BACKGROUND:Image registration lies in the core of augmented reality (AR), which aligns the virtual scene with the reality. In AR surgical navigation, the performance of image registration is vital to the surgical outcome. METHODS:This paper presents a practical marker-less image registration method for AR-guided oral ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01921-5

    authors: Wang J,Shen Y,Yang S

    更新日期:2019-05-01 00:00:00

  • A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia.

    abstract:PURPOSE:Automatic segmentation of anatomical structures and lesions from medical ultrasound images is a formidable challenge in medical imaging due to image noise, blur and artifacts. In this paper we present a segmentation technique with features highly suited to use in noisy 3D ultrasound volumes and demonstrate its ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1239-5

    authors: Hareendranathan AR,Mabee M,Punithakumar K,Noga M,Jaremko JL

    更新日期:2016-01-01 00:00:00

  • Language-based translation and prediction of surgical navigation steps for endoscopic wayfinding assistance in minimally invasive surgery.

    abstract:PURPOSE:In the context of aviation and automotive navigation technology, assistance functions are associated with predictive planning and wayfinding tasks. In endoscopic minimally invasive surgery, however, assistance so far relies primarily on image-based localization and classification. We show that navigation workfl...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02264-2

    authors: Bieck R,Heuermann K,Pirlich M,Neumann J,Neumuth T

    更新日期:2020-12-01 00:00:00

  • Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1282-2

    authors: Chen X,Cheng J,Gu X,Sun Y,Politis C

    更新日期:2016-04-01 00:00:00

  • Accuracy analysis in MRI-guided robotic prostate biopsy.

    abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0831-9

    authors: Xu H,Lasso A,Guion P,Krieger A,Kaushal A,Singh AK,Pinto PA,Coleman J,Grubb RL 3rd,Lattouf JB,Menard C,Whitcomb LL,Fichtinger G

    更新日期:2013-11-01 00:00:00

  • Average sound speed estimation using speckle analysis of medical ultrasound data.

    abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0690-9

    authors: Qu X,Azuma T,Liang JT,Nakajima Y

    更新日期:2012-11-01 00:00:00

  • A dataset of laryngeal endoscopic images with comparative study on convolution neural network-based semantic segmentation.

    abstract:PURPOSE:Automated segmentation of anatomical structures in medical image analysis is a prerequisite for autonomous diagnosis as well as various computer- and robot-aided interventions. Recent methods based on deep convolutional neural networks (CNN) have outperformed former heuristic methods. However, those methods wer...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01910-0

    authors: Laves MH,Bicker J,Kahrs LA,Ortmaier T

    更新日期:2019-03-01 00:00:00

  • A deep learning framework for efficient analysis of breast volume and fibroglandular tissue using MR data with strong artifacts.

    abstract:PURPOSE:The main purpose of this work is to develop, apply, and evaluate an efficient approach for breast density estimation in magnetic resonance imaging data, which contain strong artifacts including intensity inhomogeneities. METHODS:We present a pipeline for breast density estimation, which consists of intensity i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01928-y

    authors: Ivanovska T,Jentschke TG,Daboul A,Hegenscheid K,Völzke H,Wörgötter F

    更新日期:2019-10-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • Multi-trajectories automatic planner for StereoElectroEncephaloGraphy (SEEG).

    abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1004-1

    authors: De Momi E,Caborni C,Cardinale F,Casaceli G,Castana L,Cossu M,Mai R,Gozzo F,Francione S,Tassi L,Lo Russo G,Antiga L,Ferrigno G

    更新日期:2014-11-01 00:00:00

  • Comparison of the application of B-mode and strain elastography ultrasound in the estimation of lymph node metastasis of papillary thyroid carcinoma based on a radiomics approach.

    abstract:PURPOSE:B-mode ultrasound (B-US) and strain elastography ultrasound (SE-US) images have a potential to distinguish thyroid tumor with different lymph node (LN) status. The purpose of our study is to investigate whether the application of multi-modality images including B-US and SE-US can improve the discriminability of...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1796-5

    authors: Liu T,Ge X,Yu J,Guo Y,Wang Y,Wang W,Cui L

    更新日期:2018-10-01 00:00:00

  • Comparing calibration approaches for 3D ultrasound probes.

    abstract:OBJECTIVE:By adding a tracking sensor to a 3D ultrasound (US) probe and thus locating the probe in space, new applications within the fields of image guided surgery and radiation therapy are possible. To locate the US volume in space, a calibration is necessary to determine the mathematical transformation for mapping p...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0258-x

    authors: Bergmeir C,Seitel M,Frank C,De Simone R,Meinzer HP,Wolf I

    更新日期:2009-03-01 00:00:00

  • Construct and face validity of SINERGIA laparoscopic virtual reality simulator.

    abstract:PURPOSE:Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reali...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0425-8

    authors: Sánchez-Peralta LF,Sánchez-Margallo FM,Moyano-Cuevas JL,Pagador JB,Enciso-Sanz S,Sánchez-González P,Gómez-Aguilera EJ,Usón-Gargallo J

    更新日期:2010-07-01 00:00:00

  • Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks.

    abstract:PURPOSE:In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to rea...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01965-7

    authors: Pfeiffer M,Riediger C,Weitz J,Speidel S

    更新日期:2019-07-01 00:00:00

  • Real-time inextensible surgical thread simulation.

    abstract:PURPOSE:This paper discusses a real-time simulation method of inextensible surgical thread based on the Cosserat rod theory using position-based dynamics (PBD). The method realizes stable twining and knotting of surgical thread while including inextensibility, bending, twisting and coupling effects. METHODS:The Cosser...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1739-1

    authors: Xu L,Liu Q

    更新日期:2018-07-01 00:00:00

  • Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

    abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1347-2

    authors: Wang X,Habert S,Ma M,Huang CH,Fallavollita P,Navab N

    更新日期:2016-08-01 00:00:00

  • A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    abstract:PURPOSE:Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. METHOD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1078-9

    authors: Dagnino G,Mattos LS,Caldwell DG

    更新日期:2015-02-01 00:00:00

  • Planning nonlinear access paths for temporal bone surgery.

    abstract:PURPOSE:Interventions at the otobasis operate in the narrow region of the temporal bone where several highly sensitive organs define obstacles with minimal clearance for surgical instruments. Nonlinear trajectories for potential minimally invasive interventions can provide larger distances to risk structures and optimi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1712-z

    authors: Fauser J,Sakas G,Mukhopadhyay A

    更新日期:2018-05-01 00:00:00

  • System events: readily accessible features for surgical phase detection.

    abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1409-0

    authors: Malpani A,Lea C,Chen CC,Hager GD

    更新日期:2016-06-01 00:00:00

  • Incorporating prior shape knowledge via data-driven loss model to improve 3D liver segmentation in deep CNNs.

    abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02085-y

    authors: Mohagheghi S,Foruzan AH

    更新日期:2020-02-01 00:00:00