Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.

Abstract:

PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficient to distinguish the target lesion from normal prostate tissue. MRI usually offers a much better contrast between the lesion and surrounding tissues. Registration between TRUS and MRI may therefore significantly improve lesion targeting capability in focal prostate brachytherapy. In this paper, we present a deformable registration framework for the accurate fusion of TRUS and MRI prostate volumes under large deformations arising from dissimilarities in diameter, shape and orientation between endorectal coils and TRUS probes. METHODS:Following pose correction by a RANSAC implementation of the ICP algorithm, TRUS and MRI Prostate contour points are represented by a 3D extension of the shape-context descriptor and matched by the Hungarian algorithm. Eventually, a smooth free-form warping is computed by fitting a 3D B-spline mesh to the set of matched points. RESULTS:Quantitative validation of the registration accuracy is provided on a retrospective set of ten real cases, using as landmarks either brachytherapy seeds (six cases) or external beam radiotherapy fiducials (four cases) implanted and visible in both modalities. The average registration error between the landmarks was 2.49 and 3.20 mm, for the brachytherapy and external beam sets, respectively, that is less than the MRI voxels' long axis length ([Formula: see text]). The overall average registration error (for brachytherapy and external beam datasets together) was 2.56 mm. CONCLUSIONS:The proposed method provides a promising framework for TRUS-MRI registration in focal prostate brachytherapy.

authors

Mayer A,Zholkover A,Portnoy O,Raviv G,Konen E,Symon Z

doi

10.1007/s11548-016-1380-9

subject

Has Abstract

pub_date

2016-06-01 00:00:00

pages

1015-23

issue

6

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-016-1380-9

journal_volume

11

pub_type

杂志文章
  • A gesture-controlled projection display for CT-guided interventions.

    abstract:PURPOSE:The interaction with interventional imaging systems within a sterile environment is a challenging task for physicians. Direct physician-machine interaction during an intervention is rather limited because of sterility and workspace restrictions. METHODS:We present a gesture-controlled projection display that e...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1215-0

    authors: Mewes A,Saalfeld P,Riabikin O,Skalej M,Hansen C

    更新日期:2016-01-01 00:00:00

  • Statistical model based analysis of bone mineral density of lumbar spine.

    abstract:OBJECTIVE:For planning surgical interventions at the spine affected by osteoporosis, accurate information about the local bone quality in terms of anchorage strength for implants is very important. Based on previous work on automated bone quality assessment on the proximal femur with a completely automated model-based ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0287-0

    authors: Leber S,Fritscher KD,Schmoelz W,Schubert R

    更新日期:2009-05-01 00:00:00

  • Preliminary study on magnetic tracking-based planar shape sensing and navigation for flexible surgical robots in transoral surgery: methods and phantom experiments.

    abstract:PURPOSE:Flexible surgical robot can work in confined and complex environments, which makes it a good option for minimally invasive surgery. In order to utilize flexible manipulators in complicated and constrained surgical environments, it is of great significance to monitor the position and shape of the curvilinear man...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1672-8

    authors: Song S,Zhang C,Liu L,Meng MQ

    更新日期:2018-02-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • Robust motion tracking in liver from 2D ultrasound images using supporters.

    abstract:PURPOSE:Effectiveness of image-guided radiation therapy with precise dose delivery depends highly on accurate target localization, which may involve motion during treatment due to, e.g., breathing and drift. Therefore, it is important to track the motion and adjust the radiation delivery accordingly. Tracking generally...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1559-8

    authors: Ozkan E,Tanner C,Kastelic M,Mattausch O,Makhinya M,Goksel O

    更新日期:2017-06-01 00:00:00

  • Myocardium tracking via matching distributions.

    abstract:OBJECTIVE:The goal of this study is to investigate automatic myocardium tracking in cardiac Magnetic Resonance (MR) sequences using global distribution matching via level-set curve evolution. Rather than relying on the pixelwise information as in existing approaches, distribution matching compares intensity distributio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0265-y

    authors: Ben Ayed I,Li S,Ross I,Islam A

    更新日期:2009-01-01 00:00:00

  • Projection-based visual guidance for robot-aided RF needle insertion.

    abstract:PURPOSE:The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0897-4

    authors: Wen R,Chui CK,Ong SH,Lim KB,Chang SK

    更新日期:2013-11-01 00:00:00

  • A computer analysis method for correlating knee X-rays with continuous indicators.

    abstract:PURPOSE:To develop an image analysis method that can automatically find correlations between a set of plain radiographs and continuous clinical or physiological indicators. METHODS:Knee X-rays taken from the Baltimore Longitudinal Study of Aging are used in this study. The computer analysis method is based on the WND-...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0550-z

    authors: Shamir L

    更新日期:2011-09-01 00:00:00

  • A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

    abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1309-8

    authors: Fusaglia M,Hess H,Schwalbe M,Peterhans M,Tinguely P,Weber S,Lu H

    更新日期:2016-08-01 00:00:00

  • Multistage segmentation model and SVM-ensemble for precise lung nodule detection.

    abstract:PURPOSE:Lung cancer detection at its initial stages increases the survival chances of patients. Automatic detection of lung nodules facilitates radiologists during the diagnosis. However, there is a challenge of false positives in automated systems which may lead to wrong findings. Precise segmentation facilitates to a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1715-9

    authors: Naqi SM,Sharif M,Yasmin M

    更新日期:2018-07-01 00:00:00

  • Learned optical flow for intra-operative tracking of the retinal fundus.

    abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02160-9

    authors: Ravasio CS,Pissas T,Bloch E,Flores B,Jalali S,Stoyanov D,Cardoso JM,Da Cruz L,Bergeles C

    更新日期:2020-05-01 00:00:00

  • Orbital volume analysis: validation of a semi-automatic software segmentation method.

    abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1254-6

    authors: Jansen J,Schreurs R,Dubois L,Maal TJ,Gooris PJ,Becking AG

    更新日期:2016-01-01 00:00:00

  • Gain determination of feedback force for an ultrasound scanning robot using genetic algorithm.

    abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01915-3

    authors: Kim YJ,Park CK,Kim KG

    更新日期:2019-05-01 00:00:00

  • Feature detection in biological tissues using multi-band and narrow-band imaging.

    abstract:PURPOSE:In the past decade, augmented reality systems have been expected to support surgical operations by making it possible to view invisible objects that are inside or occluded by the skull, hands, or organs. However, the properties of biological tissues that are non-rigid and featureless require a large number of d...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1458-4

    authors: Tamura Y,Mashita T,Kuroda Y,Kiyokawa K,Takemura H

    更新日期:2016-12-01 00:00:00

  • Patch-based classification of gallbladder wall vascularity from laparoscopic images using deep learning.

    abstract:PURPOSE:In this study, we propose a deep learning approach for assessment of gallbladder (GB) wall vascularity from images of laparoscopic cholecystectomy (LC). Difficulty in the visualization of GB wall vessels may be the result of fatty infiltration or increased thickening of the GB wall, potentially as a result of c...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02285-x

    authors: Loukas C,Frountzas M,Schizas D

    更新日期:2021-01-01 00:00:00

  • Correction to: Automated measurement of bone scan index from a whole-body bone scintigram.

    abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 已发布勘误

    doi:10.1007/s11548-020-02119-w

    authors: Shimizu A,Wakabayashi H,Kanamori T,Saito A,Nishikawa K,Daisaki H,Higashiyama S,Kawabe J

    更新日期:2020-03-01 00:00:00

  • Automated aorta segmentation in low-dose chest CT images.

    abstract:PURPOSE:Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0924-5

    authors: Xie Y,Padgett J,Biancardi AM,Reeves AP

    更新日期:2014-03-01 00:00:00

  • Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

    abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1590-9

    authors: Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

    更新日期:2017-07-01 00:00:00

  • Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1228-8

    authors: Wagner ME,Gellrich NC,Friese KI,Becker M,Wolter FE,Lichtenstein JT,Stoetzer M,Rana M,Essig H

    更新日期:2016-01-01 00:00:00

  • Ultrasound texture-based CAD system for detecting neuromuscular diseases.

    abstract:PURPOSE:Diagnosis of neuromuscular diseases in ultrasonography is a challenging task since experts are often unable to discriminate between healthy and pathological cases. A computer-aided diagnosis (CAD) system for skeletal muscle ultrasonography was developed and tested for myositis detection in ultrasound images of ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1133-6

    authors: König T,Steffen J,Rak M,Neumann G,von Rohden L,Tönnies KD

    更新日期:2015-09-01 00:00:00

  • A preregistered STAMP method for image-guided temporal bone surgery.

    abstract:OBJECTIVES:Image-guided otological surgeries require minimal invasiveness and high accuracy, and these two factors usually compete with each other. Our recently developed registration method, called the STAMP method, showed minimal invasiveness with accuracy comparable to that of the current more invasive registration ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0916-5

    authors: Oka M,Cho B,Matsumoto N,Hong J,Jinnouchi M,Ouchida R,Komune S,Hashizume M

    更新日期:2014-01-01 00:00:00

  • Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study.

    abstract:PURPOSE:To perform bronchoscopy safely and smoothly, it is very important to develop a bronchoscopic guidance system. Transbronchial lung biopsy (TBLB) with a bronchoscopic guidance system especially should permit safe image-guided procedures. Recently, electromagnetic tracking (EMT) is utilized to track the tip of the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0626-9

    authors: Deguchi D,Feuerstein M,Kitasaka T,Suenaga Y,Ide I,Murase H,Imaizumi K,Hasegawa Y,Mori K

    更新日期:2012-05-01 00:00:00

  • A method for going from 2D laparoscope to 3D acquisition of surface landmarks by a novel computer vision approach.

    abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1655-9

    authors: Garbey M,Nguyen TB,Huang AY,Fikfak V,Dunkin BJ

    更新日期:2018-02-01 00:00:00

  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis.

    abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0976-1

    authors: Krüger J,Ehrhardt J,Bischof A,Handels H

    更新日期:2014-05-01 00:00:00

  • Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1282-2

    authors: Chen X,Cheng J,Gu X,Sun Y,Politis C

    更新日期:2016-04-01 00:00:00

  • Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1752-4

    authors: Graf EC,Ott I,Praceus J,Bourier F,Lueth TC

    更新日期:2018-06-01 00:00:00

  • Multi-trajectories automatic planner for StereoElectroEncephaloGraphy (SEEG).

    abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1004-1

    authors: De Momi E,Caborni C,Cardinale F,Casaceli G,Castana L,Cossu M,Mai R,Gozzo F,Francione S,Tassi L,Lo Russo G,Antiga L,Ferrigno G

    更新日期:2014-11-01 00:00:00

  • Development of a shoulder-mounted robot for MRI-guided needle placement: phantom study.

    abstract:PURPOSE:This paper presents new quantitative data on a signal-to-noise ratio (SNR) study, distortion study, and targeting accuracy phantom study for our patient-mounted robot (called Arthrobot). Arthrobot was developed as an MRI-guided needle placement device for diagnostic and interventional procedures such as arthrog...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1839-y

    authors: Monfaredi R,Iordachita I,Wilson E,Sze R,Sharma K,Krieger A,Fricke S,Cleary K

    更新日期:2018-11-01 00:00:00