Robust motion tracking in liver from 2D ultrasound images using supporters.

Abstract:

PURPOSE:Effectiveness of image-guided radiation therapy with precise dose delivery depends highly on accurate target localization, which may involve motion during treatment due to, e.g., breathing and drift. Therefore, it is important to track the motion and adjust the radiation delivery accordingly. Tracking generally requires reliable target appearance and image features, whereas in ultrasound imaging acoustic shadowing and other artifacts may degrade the visibility of a target, leading to substantial tracking errors. To minimize such errors, we propose a method based on so-called supporters, a computer vision tracking technique. This allows us to leverage information from surrounding motion for improving robustness of motion tracking on 2D ultrasound image sequences of the liver. METHODS:Image features, potentially useful for predicting the target positions, are individually tracked, and a supporter model capturing the coupling of motion between these features and the target is learned on-line. This model is then applied to predict the target position, when the target cannot be otherwise tracked reliably. RESULTS:The proposed method was evaluated using the Challenge on Liver Ultrasound Tracking (CLUST)-2015 dataset. Leave-one-out cross-validation was performed on the training set of 24 2D image sequences of each 1-5 min. The method was then applied on the test set (24 2D sequences), where the results were evaluated by the challenge organizers, yielding 1.04 mm mean and 2.26 mm 95%ile tracking error for all targets. We also devised a simulation framework to emulate acoustic shadowing artifacts from the ribs, which showed effective tracking despite the shadows. CONCLUSIONS:Results support the feasibility and demonstrate the advantages of using supporters. The proposed method improves its baseline tracker, which uses optic flow and elliptic vessel models, and yields the state-of-the-art real-time tracking solution for the CLUST challenge.

authors

Ozkan E,Tanner C,Kastelic M,Mattausch O,Makhinya M,Goksel O

doi

10.1007/s11548-017-1559-8

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

941-950

issue

6

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-017-1559-8

journal_volume

12

pub_type

杂志文章
  • Correction to: Automated measurement of bone scan index from a whole-body bone scintigram.

    abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 已发布勘误

    doi:10.1007/s11548-020-02119-w

    authors: Shimizu A,Wakabayashi H,Kanamori T,Saito A,Nishikawa K,Daisaki H,Higashiyama S,Kawabe J

    更新日期:2020-03-01 00:00:00

  • A projected landmark method for reduction of registration error in image-guided surgery systems.

    abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1075-z

    authors: Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SM

    更新日期:2015-05-01 00:00:00

  • Shared control of a medical robot with haptic guidance.

    abstract:PURPOSE:Tele-operation of robotic surgery reduces the radiation exposure during the interventional radiological operations. However, endoscope vision without force feedback on the surgical tool increases the difficulty for precise manipulation and the risk of tissue damage. The shared control of vision and force provid...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1425-0

    authors: Xiong L,Chng CB,Chui CK,Yu P,Li Y

    更新日期:2017-01-01 00:00:00

  • Generative multi-adversarial network for striking the right balance in abdominal image segmentation.

    abstract::Purpose The identification of abnormalities that are relatively rare within otherwise normal anatomy is a major challenge for deep learning in the semantic segmentation of medical images. The small number of samples of the minority classes in the training data makes the learning of optimal classification challenging, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02254-4

    authors: Rezaei M,Näppi JJ,Lippert C,Meinel C,Yoshida H

    更新日期:2020-11-01 00:00:00

  • MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

    abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0964-x

    authors: Yiallouras C,Mylonas N,Damianou C

    更新日期:2014-07-01 00:00:00

  • A computer vision technique for automated assessment of surgical performance using surgeons' console-feed videos.

    abstract:PURPOSE:To develop and validate an automated assessment of surgical performance (AASP) system for objective and computerized assessment of pelvic lymph node dissection (PLND) as an integral part of robot-assisted radical cystectomy (RARC) using console-feed videos recorded during live surgery. METHODS:Video recordings...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1881-9

    authors: Baghdadi A,Hussein AA,Ahmed Y,Cavuoto LA,Guru KA

    更新日期:2019-04-01 00:00:00

  • Optimal setting of image bounding box can improve registration accuracy of diffusion tensor tractography.

    abstract:PURPOSE:When we register diffusion tensor tractography (DTT) to anatomical images such as fast imaging employing steady-state acquisition (FIESTA), we register the B0 image to FIESTA. Precise registration of the DTT B0 image to FIESTA is possible with non-rigid registration compared to rigid registration, although the ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0934-3

    authors: Yoshino M,Kin T,Saito T,Nakagawa D,Nakatomi H,Kunimatsu A,Oyama H,Saito N

    更新日期:2013-08-20 00:00:00

  • Fast and flexible distance measures for treatment planning.

    abstract:PURPOSE:Distance measures are required for diagnoses, therapy decision and documentation. With today's high-resolution CT and MR imaging techniques, high- quality images have become possible. Yet, manual measurement can be tedious. We present a method for automatically determining different distance-based measures on s...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0519-3

    authors: Rössling I,Cyrus C,Dornheim L,Boehm A,Preim B

    更新日期:2010-11-01 00:00:00

  • A practical marker-less image registration method for augmented reality oral and maxillofacial surgery.

    abstract:BACKGROUND:Image registration lies in the core of augmented reality (AR), which aligns the virtual scene with the reality. In AR surgical navigation, the performance of image registration is vital to the surgical outcome. METHODS:This paper presents a practical marker-less image registration method for AR-guided oral ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01921-5

    authors: Wang J,Shen Y,Yang S

    更新日期:2019-05-01 00:00:00

  • Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers.

    abstract:PURPOSE:Conventional positron emission tomography can be used only preoperatively to identify lymph node metastases, and hence, these growths are difficult to locate intraoperatively. Previously, an intraoperative laparoscopic coincidence imaging system, with an external fixed detector array and a detector probe that c...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02282-0

    authors: Liyanaarachchi MR,Shimazoe K,Takahashi H,Nakagawa K,Kobayashi E,Sakuma I

    更新日期:2021-01-01 00:00:00

  • Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions.

    abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02029-6

    authors: de Jong TL,Moelker A,Dankelman J,van den Dobbelsteen JJ

    更新日期:2019-12-01 00:00:00

  • Automated muscle segmentation from CT images of the hip and thigh using a hierarchical multi-atlas method.

    abstract:PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1758-y

    authors: Yokota F,Otake Y,Takao M,Ogawa T,Okada T,Sugano N,Sato Y

    更新日期:2018-07-01 00:00:00

  • Continuous roadmapping in liver TACE procedures using 2D-3D catheter-based registration.

    abstract:PURPOSE:Fusion of pre/perioperative images and intra-operative images may add relevant information during image-guided procedures. In abdominal procedures, respiratory motion changes the position of organs, and thus accurate image guidance requires a continuous update of the spatial alignment of the (pre/perioperative)...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1218-x

    authors: Ambrosini P,Ruijters D,Niessen WJ,Moelker A,van Walsum T

    更新日期:2015-09-01 00:00:00

  • Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy.

    abstract:PURPOSE:Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we pro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02181-4

    authors: Kalia M,Mathur P,Tsang K,Black P,Navab N,Salcudean S

    更新日期:2020-07-01 00:00:00

  • Differential geometry-based techniques for characterization of boundary roughness of pulmonary nodules in CT images.

    abstract:PURPOSE:Boundary roughness of a pulmonary nodule is an important indication of its malignancy. The irregularity of the shape of a nodule is represented in terms of a few diagnostic characteristics such as spiculation, lobulation, and sphericity. Quantitative characterization of these diagnostic characteristics is essen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1284-0

    authors: Dhara AK,Mukhopadhyay S,Saha P,Garg M,Khandelwal N

    更新日期:2016-03-01 00:00:00

  • Meaningful Assessment of Robotic Surgical Style using the Wisdom of Crowds.

    abstract:OBJECTIVE:Quantitative assessment of surgical skills is an important aspect of surgical training; however, the proposed metrics are sometimes difficult to interpret and may not capture the stylistic characteristics that define expertise. This study proposes a methodology for evaluating the surgical skill, based on metr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1738-2

    authors: Ershad M,Rege R,Fey AM

    更新日期:2018-07-01 00:00:00

  • Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

    abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0921-8

    authors: Qian K,Ando T,Nakamura K,Liao H,Kobayashi E,Yahagi N,Sakuma I

    更新日期:2014-03-01 00:00:00

  • A framework for correcting brain retraction based on an eXtended Finite Element Method using a laser range scanner.

    abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0958-8

    authors: Li P,Wang W,Song Z,An Y,Zhang C

    更新日期:2014-07-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • On-patient see-through augmented reality based on visual SLAM.

    abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1444-x

    authors: Mahmoud N,Grasa ÓG,Nicolau SA,Doignon C,Soler L,Marescaux J,Montiel JM

    更新日期:2017-01-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • Robust calculation of the midsagittal plane in CT scans using the Kullback-Leibler's measure.

    abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0366-2

    authors: Puspitasari F,Volkau I,Ambrosius W,Nowinski WL

    更新日期:2009-11-01 00:00:00

  • Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

    abstract:PURPOSE:Organ motion due to patient breathing introduces a technical challenge for dosimetry and lung tumor treatment by hadron therapy. Accurate dose distribution estimation requires patient-specific information on tumor position, size, and shape as well as information regarding the material density and stopping power...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0935-2

    authors: Manescu P,Ladjal H,Azencot J,Beuve M,Testa E,Shariat B

    更新日期:2014-05-01 00:00:00

  • A computer analysis method for correlating knee X-rays with continuous indicators.

    abstract:PURPOSE:To develop an image analysis method that can automatically find correlations between a set of plain radiographs and continuous clinical or physiological indicators. METHODS:Knee X-rays taken from the Baltimore Longitudinal Study of Aging are used in this study. The computer analysis method is based on the WND-...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0550-z

    authors: Shamir L

    更新日期:2011-09-01 00:00:00

  • PyDBS: an automated image processing workflow for deep brain stimulation surgery.

    abstract:PURPOSE:Deep brain stimulation (DBS) is a surgical procedure for treating motor-related neurological disorders. DBS clinical efficacy hinges on precise surgical planning and accurate electrode placement, which in turn call upon several image processing and visualization tasks, such as image registration, image segmenta...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1007-y

    authors: D'Albis T,Haegelen C,Essert C,Fernández-Vidal S,Lalys F,Jannin P

    更新日期:2015-02-01 00:00:00

  • Automatic bone segmentation in whole-body CT images.

    abstract:PURPOSE:Many diagnostic or treatment planning applications critically depend on the successful localization of bony structures in CT images. Manual or semiautomatic bone segmentation is tedious, however, and often not practical in clinical routine. In this paper, we present a reliable and fully automatic bone segmentat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1883-7

    authors: Klein A,Warszawski J,Hillengaß J,Maier-Hein KH

    更新日期:2019-01-01 00:00:00

  • Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery.

    abstract:PURPOSE:The objective of this work is to develop a preoperative reconstruction plate design system for unilateral pelvic and acetabular fracture reduction and internal fixation surgery, using computer graphics and augmented reality (AR) techniques, in order to respect the patient-specific morphology and to reduce surgi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0775-5

    authors: Shen F,Chen B,Guo Q,Qi Y,Shen Y

    更新日期:2013-03-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Knee arthroscopic navigation using virtual-vision rendering and self-positioning technology.

    abstract:PURPOSE:Knee arthroscopy suffers from a lack of depth information and easy occlusion of the visual field. To solve these limitations, we propose an arthroscopic navigation system based on self-positioning technology, with the guidance of virtual-vision views. This system can work without any external tracking devices o...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02099-6

    authors: Ma C,Cui X,Chen F,Ma L,Xin S,Liao H

    更新日期:2020-03-01 00:00:00

  • Multistage segmentation model and SVM-ensemble for precise lung nodule detection.

    abstract:PURPOSE:Lung cancer detection at its initial stages increases the survival chances of patients. Automatic detection of lung nodules facilitates radiologists during the diagnosis. However, there is a challenge of false positives in automated systems which may lead to wrong findings. Precise segmentation facilitates to a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1715-9

    authors: Naqi SM,Sharif M,Yasmin M

    更新日期:2018-07-01 00:00:00