PyDBS: an automated image processing workflow for deep brain stimulation surgery.

Abstract:

PURPOSE:Deep brain stimulation (DBS) is a surgical procedure for treating motor-related neurological disorders. DBS clinical efficacy hinges on precise surgical planning and accurate electrode placement, which in turn call upon several image processing and visualization tasks, such as image registration, image segmentation, image fusion, and 3D visualization. These tasks are often performed by a heterogeneous set of software tools, which adopt differing formats and geometrical conventions and require patient-specific parameterization or interactive tuning. To overcome these issues, we introduce in this article PyDBS, a fully integrated and automated image processing workflow for DBS surgery. METHODS:PyDBS consists of three image processing pipelines and three visualization modules assisting clinicians through the entire DBS surgical workflow, from the preoperative planning of electrode trajectories to the postoperative assessment of electrode placement. The system's robustness, speed, and accuracy were assessed by means of a retrospective validation, based on 92 clinical cases. RESULTS:The complete PyDBS workflow achieved satisfactory results in 92 % of tested cases, with a median processing time of 28 min per patient. CONCLUSION:The results obtained are compatible with the adoption of PyDBS in clinical practice.

authors

D'Albis T,Haegelen C,Essert C,Fernández-Vidal S,Lalys F,Jannin P

doi

10.1007/s11548-014-1007-y

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

117-28

issue

2

eissn

1861-6410

issn

1861-6429

journal_volume

10

pub_type

杂志文章
  • Breast masses detection using phase portrait analysis and fuzzy inference systems.

    abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0659-0

    authors: Mencattini A,Salmeri M

    更新日期:2012-07-01 00:00:00

  • Incorporating prior shape knowledge via data-driven loss model to improve 3D liver segmentation in deep CNNs.

    abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02085-y

    authors: Mohagheghi S,Foruzan AH

    更新日期:2020-02-01 00:00:00

  • Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

    abstract:PURPOSE:Epidural and spinal needle insertions, as well as facet joint denervation and injections are widely performed procedures on the lumbar spine for delivering anesthesia and analgesia. Ultrasound (US)-based approaches have gained popularity for accurate needle placement, as they use a non-ionizing, inexpensive and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1552-2

    authors: Behnami D,Sedghi A,Anas EMA,Rasoulian A,Seitel A,Lessoway V,Ungi T,Yen D,Osborn J,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2017-06-01 00:00:00

  • Generative multi-adversarial network for striking the right balance in abdominal image segmentation.

    abstract::Purpose The identification of abnormalities that are relatively rare within otherwise normal anatomy is a major challenge for deep learning in the semantic segmentation of medical images. The small number of samples of the minority classes in the training data makes the learning of optimal classification challenging, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02254-4

    authors: Rezaei M,Näppi JJ,Lippert C,Meinel C,Yoshida H

    更新日期:2020-11-01 00:00:00

  • Robust and semantic needle detection in 3D ultrasound using orthogonal-plane convolutional neural networks.

    abstract:PURPOSE:During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS:We present a novel appr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1798-3

    authors: Pourtaherian A,Ghazvinian Zanjani F,Zinger S,Mihajlovic N,Ng GC,Korsten HHM,de With PHN

    更新日期:2018-09-01 00:00:00

  • Accurate two-dimensional cardiac strain calculation using adaptive windowed Fourier transform and Gabor wavelet transform.

    abstract:PURPOSE:Cardiac strain calculated from tagged magnetic resonance (MR) images provides clinicians information about abnormalities of heart-wall motion in patients. It is important to develop an accurate method to determine the cardiac strain efficiently. An adaptive windowed harmonic phase (AWHARP) method is proposed fo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0689-2

    authors: Fu YB,Chui CK,Teo CL

    更新日期:2013-01-01 00:00:00

  • BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1603-8

    authors: Chen D,Chen W,Huang L,Feng X,Peters T,Gu L

    更新日期:2017-09-01 00:00:00

  • Average sound speed estimation using speckle analysis of medical ultrasound data.

    abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0690-9

    authors: Qu X,Azuma T,Liang JT,Nakajima Y

    更新日期:2012-11-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • A computer analysis method for correlating knee X-rays with continuous indicators.

    abstract:PURPOSE:To develop an image analysis method that can automatically find correlations between a set of plain radiographs and continuous clinical or physiological indicators. METHODS:Knee X-rays taken from the Baltimore Longitudinal Study of Aging are used in this study. The computer analysis method is based on the WND-...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0550-z

    authors: Shamir L

    更新日期:2011-09-01 00:00:00

  • A fully 3D work context for oral implant planning and simulation.

    abstract:PURPOSE:Most software systems for oral implantology are based on a two-dimensional multi-view approach, often accompanied with a surface rendered model. Usually they are affected by common errors like anisotropy of the volume and distortion on measurements. A more integrated and realistic 3D approach for implant surger...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0394-y

    authors: Chiarelli T,Lamma E,Sansoni T

    更新日期:2010-01-01 00:00:00

  • A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    abstract:PURPOSE:Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. METHOD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1078-9

    authors: Dagnino G,Mattos LS,Caldwell DG

    更新日期:2015-02-01 00:00:00

  • Image-based 3D modeling and validation of radiofrequency interstitial tumor ablation using a tissue-mimicking breast phantom.

    abstract:PURPOSE:Minimally invasive treatment of solid cancers, especially in the breast and liver, remains clinically challenging, despite a variety of treatment modalities, including radiofrequency ablation (RFA), microwave ablation or high-intensity focused ultrasound. Each treatment modality has advantages and disadvantages...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0769-3

    authors: Wang Z,Aarya I,Gueorguieva M,Liu D,Luo H,Manfredi L,Wang L,McLean D,Coleman S,Brown S,Cuschieri A

    更新日期:2012-11-01 00:00:00

  • Pre-clinical evaluation of an image-guided in-situ Raman spectroscopy navigation system for targeted prostate cancer interventions.

    abstract:PURPOSE:Transrectal ultrasound (TRUS) image guidance is the standard of care for diagnostic and therapeutic interventions in prostate cancer (PCa) patients, but can lead to high false-negative rates, compromising downstream effectiveness of therapeutic choices. A promising approach to improve in-situ detection of PCa l...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02136-9

    authors: Shams R,Picot F,Grajales D,Sheehy G,Dallaire F,Birlea M,Saad F,Trudel D,Menard C,Leblond F,Kadoury S

    更新日期:2020-05-01 00:00:00

  • Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks.

    abstract:PURPOSE:In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to rea...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01965-7

    authors: Pfeiffer M,Riediger C,Weitz J,Speidel S

    更新日期:2019-07-01 00:00:00

  • Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers.

    abstract:PURPOSE:Conventional positron emission tomography can be used only preoperatively to identify lymph node metastases, and hence, these growths are difficult to locate intraoperatively. Previously, an intraoperative laparoscopic coincidence imaging system, with an external fixed detector array and a detector probe that c...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02282-0

    authors: Liyanaarachchi MR,Shimazoe K,Takahashi H,Nakagawa K,Kobayashi E,Sakuma I

    更新日期:2021-01-01 00:00:00

  • Image-guided placement of the Bonebridge™ without surgical navigation equipment.

    abstract:PURPOSE:   Most of the current Bonebridge surgeries undergo preoperative simulation planning in a computer. However, surgeons usually use the landmarks on the bone surface to determine the location where to implant the device, using the simulation image in the computer only as a reference (conventional method). We deve...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0973-9

    authors: Cho B,Matsumoto N,Mori M,Komune S,Hashizume M

    更新日期:2014-09-01 00:00:00

  • A deep learning framework for efficient analysis of breast volume and fibroglandular tissue using MR data with strong artifacts.

    abstract:PURPOSE:The main purpose of this work is to develop, apply, and evaluate an efficient approach for breast density estimation in magnetic resonance imaging data, which contain strong artifacts including intensity inhomogeneities. METHODS:We present a pipeline for breast density estimation, which consists of intensity i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01928-y

    authors: Ivanovska T,Jentschke TG,Daboul A,Hegenscheid K,Völzke H,Wörgötter F

    更新日期:2019-10-01 00:00:00

  • Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery.

    abstract:PURPOSE:The objective of this work is to develop a preoperative reconstruction plate design system for unilateral pelvic and acetabular fracture reduction and internal fixation surgery, using computer graphics and augmented reality (AR) techniques, in order to respect the patient-specific morphology and to reduce surgi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0775-5

    authors: Shen F,Chen B,Guo Q,Qi Y,Shen Y

    更新日期:2013-03-01 00:00:00

  • Design considerations for a novel MRI compatible manipulator for prostate cryoablation.

    abstract:PURPOSE:Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0558-4

    authors: Abdelaziz S,Esteveny L,Renaud P,Bayle B,Barbé L,De Mathelin M,Gangi A

    更新日期:2011-11-01 00:00:00

  • Multistage segmentation model and SVM-ensemble for precise lung nodule detection.

    abstract:PURPOSE:Lung cancer detection at its initial stages increases the survival chances of patients. Automatic detection of lung nodules facilitates radiologists during the diagnosis. However, there is a challenge of false positives in automated systems which may lead to wrong findings. Precise segmentation facilitates to a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1715-9

    authors: Naqi SM,Sharif M,Yasmin M

    更新日期:2018-07-01 00:00:00

  • A preregistered STAMP method for image-guided temporal bone surgery.

    abstract:OBJECTIVES:Image-guided otological surgeries require minimal invasiveness and high accuracy, and these two factors usually compete with each other. Our recently developed registration method, called the STAMP method, showed minimal invasiveness with accuracy comparable to that of the current more invasive registration ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0916-5

    authors: Oka M,Cho B,Matsumoto N,Hong J,Jinnouchi M,Ouchida R,Komune S,Hashizume M

    更新日期:2014-01-01 00:00:00

  • Analyzing shoulder translation with navigation technology.

    abstract:PURPOSE:Asymmetric stress imposed on the shoulder can lead to anterior shoulder instability in young athletes who perform repetitive overhead motions. A common treatment, surgical anterior capsule tightening, assumes that the instability is caused by abnormal anterior laxity. This study investigated the possibility tha...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0782-6

    authors: Zakani S,Venne G,Smith EJ,Bicknell R,Ellis RE

    更新日期:2012-11-01 00:00:00

  • Gain determination of feedback force for an ultrasound scanning robot using genetic algorithm.

    abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01915-3

    authors: Kim YJ,Park CK,Kim KG

    更新日期:2019-05-01 00:00:00

  • Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography.

    abstract:PURPOSE:A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. MATERIALS AND METHODS:Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRAD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0300-7

    authors: Destounis S,Hanson S,Morgan R,Murphy P,Somerville P,Seifert P,Andolina V,Arieno A,Skolny M,Logan-Young W

    更新日期:2009-06-01 00:00:00

  • Robust GPU-based virtual reality simulation of radio-frequency ablations for various needle geometries and locations.

    abstract:PURPOSE:Radio-frequency ablations play an important role in the therapy of malignant liver lesions. The navigation of a needle to the lesion poses a challenge for both the trainees and intervening physicians. METHODS:This publication presents a new GPU-based, accurate method for the simulation of radio-frequency ablat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02033-w

    authors: Kath N,Handels H,Mastmeyer A

    更新日期:2019-11-01 00:00:00

  • MIDG-Emerging grid technologies for multi-site preclinical molecular imaging research communities.

    abstract:PURPOSE:Molecular imaging is the visualization and identification of specific molecules in anatomy for insight into metabolic pathways, tissue consistency, and tracing of solute transport mechanisms. This paper presents the Molecular Imaging Data Grid (MIDG) which utilizes emerging grid technologies in preclinical mole...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0524-6

    authors: Lee J,Documet J,Liu B,Park R,Tank A,Huang HK

    更新日期:2011-03-01 00:00:00

  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • A visual odometry base-tracking system for intraoperative C-arm guidance.

    abstract:PURPOSE:C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view ima...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02229-5

    authors: Haliburton L,Esfandiari H,Guy P,Anglin C,Hodgson A

    更新日期:2020-10-01 00:00:00

  • Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

    abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1590-9

    authors: Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

    更新日期:2017-07-01 00:00:00