A visual odometry base-tracking system for intraoperative C-arm guidance.

Abstract:

PURPOSE:C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view images, with limited quantitative functionality. Various techniques have been proposed to improve positioning, reduce radiation exposure, and provide quantitative measuring tools, all of which require accurate C-arm position tracking. While external stereo camera systems can be used for this purpose, they are typically considered too obtrusive. This paper therefore presents the development and verification of a low-profile, real-time C-arm base-tracking system using computer vision techniques. METHODS:The proposed tracking system, called OPTIX (On-board Position Tracking for Intraoperative X-rays), uses a single downward-facing camera mounted to the base of a C-arm. Relative motion tracking and absolute position recovery algorithms were implemented to track motion using the visual texture in operating room floors. The accuracy of the system was evaluated in a simulated operating room mounted on a real C-arm. RESULTS:The relative tracking algorithm measured relative translation position changes with errors of less than 0.75% of the total distance travelled, and orientation with errors below 5% of the cumulative rotation. With an error-correction step incorporated, OPTIX achieved C-arm repositioning with translation errors of less than [Formula: see text]  mm and rotation errors of less than [Formula: see text]. A display based on the OPTIX measurements enabled consistent C-arm repositioning within 5 mm of a previously stored reference position. CONCLUSION:The system achieved clinically relevant accuracies and could result in a reduced need for scout images when re-acquiring a previous position. We believe that, if implemented in an operating room, OPTIX has the potential to reduce both operating time and harmful radiation exposure to patients and surgical staff.

authors

Haliburton L,Esfandiari H,Guy P,Anglin C,Hodgson A

doi

10.1007/s11548-020-02229-5

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

1597-1609

issue

10

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-020-02229-5

journal_volume

15

pub_type

杂志文章
  • Estimating needle tip deflection in biological tissue from a single transverse ultrasound image: application to brachytherapy.

    abstract:PURPOSE:This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. METHODS:We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1329-4

    authors: Rossa C,Sloboda R,Usmani N,Tavakoli M

    更新日期:2016-07-01 00:00:00

  • Hybrid simulation using mixed reality for interventional ultrasound imaging training.

    abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1113-x

    authors: Freschi C,Parrini S,Dinelli N,Ferrari M,Ferrari V

    更新日期:2015-07-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • Comparison of the application of B-mode and strain elastography ultrasound in the estimation of lymph node metastasis of papillary thyroid carcinoma based on a radiomics approach.

    abstract:PURPOSE:B-mode ultrasound (B-US) and strain elastography ultrasound (SE-US) images have a potential to distinguish thyroid tumor with different lymph node (LN) status. The purpose of our study is to investigate whether the application of multi-modality images including B-US and SE-US can improve the discriminability of...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1796-5

    authors: Liu T,Ge X,Yu J,Guo Y,Wang Y,Wang W,Cui L

    更新日期:2018-10-01 00:00:00

  • A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia.

    abstract:PURPOSE:Automatic segmentation of anatomical structures and lesions from medical ultrasound images is a formidable challenge in medical imaging due to image noise, blur and artifacts. In this paper we present a segmentation technique with features highly suited to use in noisy 3D ultrasound volumes and demonstrate its ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1239-5

    authors: Hareendranathan AR,Mabee M,Punithakumar K,Noga M,Jaremko JL

    更新日期:2016-01-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • Comparing calibration approaches for 3D ultrasound probes.

    abstract:OBJECTIVE:By adding a tracking sensor to a 3D ultrasound (US) probe and thus locating the probe in space, new applications within the fields of image guided surgery and radiation therapy are possible. To locate the US volume in space, a calibration is necessary to determine the mathematical transformation for mapping p...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0258-x

    authors: Bergmeir C,Seitel M,Frank C,De Simone R,Meinzer HP,Wolf I

    更新日期:2009-03-01 00:00:00

  • On-patient see-through augmented reality based on visual SLAM.

    abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1444-x

    authors: Mahmoud N,Grasa ÓG,Nicolau SA,Doignon C,Soler L,Marescaux J,Montiel JM

    更新日期:2017-01-01 00:00:00

  • Interactive bone drilling using a 2D pointing device to support Microendoscopic Discectomy planning.

    abstract:PURPOSE:To support preoperative planning of bone drilling for Microendoscopic Discectomy, we present a set of interactive bone-drilling methods using a general 2D pointing device. METHODS:Unlike the existing methods, our framework has the following features: (1) the user can directly cut away arbitrary 3D regions on t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0413-z

    authors: Imanishi K,Nakao M,Kioka M,Mori M,Yoshida M,Takahashi T,Minato K

    更新日期:2010-09-01 00:00:00

  • Preliminary study on magnetic tracking-based planar shape sensing and navigation for flexible surgical robots in transoral surgery: methods and phantom experiments.

    abstract:PURPOSE:Flexible surgical robot can work in confined and complex environments, which makes it a good option for minimally invasive surgery. In order to utilize flexible manipulators in complicated and constrained surgical environments, it is of great significance to monitor the position and shape of the curvilinear man...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1672-8

    authors: Song S,Zhang C,Liu L,Meng MQ

    更新日期:2018-02-01 00:00:00

  • Robust calculation of the midsagittal plane in CT scans using the Kullback-Leibler's measure.

    abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0366-2

    authors: Puspitasari F,Volkau I,Ambrosius W,Nowinski WL

    更新日期:2009-11-01 00:00:00

  • Myocardium tracking via matching distributions.

    abstract:OBJECTIVE:The goal of this study is to investigate automatic myocardium tracking in cardiac Magnetic Resonance (MR) sequences using global distribution matching via level-set curve evolution. Rather than relying on the pixelwise information as in existing approaches, distribution matching compares intensity distributio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0265-y

    authors: Ben Ayed I,Li S,Ross I,Islam A

    更新日期:2009-01-01 00:00:00

  • A statistical shape model of the human second cervical vertebra.

    abstract:PURPOSE:Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the sh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1121-x

    authors: Clogenson M,Duff JM,Luethi M,Levivier M,Meuli R,Baur C,Henein S

    更新日期:2015-07-01 00:00:00

  • Ultrasound thermal monitoring with an external ultrasound source for customized bipolar RF ablation shapes.

    abstract:PURPOSE:Thermotherapy is a clinical procedure which delivers thermal energy to a target, and it has been applied for various medical treatments. Temperature monitoring during thermotherapy is important to achieve precise and reproducible results. Medical ultrasound can be used for thermal monitoring and is an attractiv...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1744-4

    authors: Kim Y,Audigier C,Ziegle J,Friebe M,Boctor EM

    更新日期:2018-06-01 00:00:00

  • Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1228-8

    authors: Wagner ME,Gellrich NC,Friese KI,Becker M,Wolter FE,Lichtenstein JT,Stoetzer M,Rana M,Essig H

    更新日期:2016-01-01 00:00:00

  • [¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

    abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1260-8

    authors: Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

    更新日期:2016-05-01 00:00:00

  • Image-guided placement of the Bonebridge™ without surgical navigation equipment.

    abstract:PURPOSE:   Most of the current Bonebridge surgeries undergo preoperative simulation planning in a computer. However, surgeons usually use the landmarks on the bone surface to determine the location where to implant the device, using the simulation image in the computer only as a reference (conventional method). We deve...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0973-9

    authors: Cho B,Matsumoto N,Mori M,Komune S,Hashizume M

    更新日期:2014-09-01 00:00:00

  • Comparison of different grid of tags detection methods in tagged cardiac MR imaging.

    abstract:PURPOSE:Non-invasive imaging assessment of cardiac function is important in cardiovascular disease diagnosis, especially for evaluation of local cardiac motion. Tagged cardiac MRI has been developed for this purpose, but evaluation of the results requires quantification and automation. METHODS:Two methods utilizing ac...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0495-7

    authors: Histace A,Portefaix C,Matuszewski B

    更新日期:2011-03-01 00:00:00

  • Gain determination of feedback force for an ultrasound scanning robot using genetic algorithm.

    abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01915-3

    authors: Kim YJ,Park CK,Kim KG

    更新日期:2019-05-01 00:00:00

  • A method for going from 2D laparoscope to 3D acquisition of surface landmarks by a novel computer vision approach.

    abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1655-9

    authors: Garbey M,Nguyen TB,Huang AY,Fikfak V,Dunkin BJ

    更新日期:2018-02-01 00:00:00

  • Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

    abstract:PURPOSE:Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1556-y

    authors: Hacihaliloglu I

    更新日期:2017-06-01 00:00:00

  • A computer analysis method for correlating knee X-rays with continuous indicators.

    abstract:PURPOSE:To develop an image analysis method that can automatically find correlations between a set of plain radiographs and continuous clinical or physiological indicators. METHODS:Knee X-rays taken from the Baltimore Longitudinal Study of Aging are used in this study. The computer analysis method is based on the WND-...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0550-z

    authors: Shamir L

    更新日期:2011-09-01 00:00:00

  • Automated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI.

    abstract:PURPOSE:We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). METHODS:The method is based on superpixel technique and classification of each supe...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1483-3

    authors: Soltaninejad M,Yang G,Lambrou T,Allinson N,Jones TL,Barrick TR,Howe FA,Ye X

    更新日期:2017-02-01 00:00:00

  • Edge map analysis in chest X-rays for automatic pulmonary abnormality screening.

    abstract:PURPOSE:Our particular motivator is the need for screening HIV+ populations in resource-constrained regions for the evidence of tuberculosis, using posteroanterior chest radiographs (CXRs). METHOD:The proposed method is motivated by the observation that abnormal CXRs tend to exhibit corrupted and/or deformed thoracic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1359-6

    authors: Santosh KC,Vajda S,Antani S,Thoma GR

    更新日期:2016-09-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Brain tumor detection and segmentation in a CRF (conditional random fields) framework with pixel-pairwise affinity and superpixel-level features.

    abstract:PURPOSE:Detection and segmentation of a brain tumor such as glioblastoma multiforme (GBM) in magnetic resonance (MR) images are often challenging due to its intrinsically heterogeneous signal characteristics. A robust segmentation method for brain tumor MRI scans was developed and tested. METHODS:Simple thresholds and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0922-7

    authors: Wu W,Chen AY,Zhao L,Corso JJ

    更新日期:2014-03-01 00:00:00

  • Accurate two-dimensional cardiac strain calculation using adaptive windowed Fourier transform and Gabor wavelet transform.

    abstract:PURPOSE:Cardiac strain calculated from tagged magnetic resonance (MR) images provides clinicians information about abnormalities of heart-wall motion in patients. It is important to develop an accurate method to determine the cardiac strain efficiently. An adaptive windowed harmonic phase (AWHARP) method is proposed fo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0689-2

    authors: Fu YB,Chui CK,Teo CL

    更新日期:2013-01-01 00:00:00

  • Multi-input deep learning architecture for predicting breast tumor response to chemotherapy using quantitative MR images.

    abstract:PURPOSE:Neoadjuvant chemotherapy (NAC) aims to minimize the tumor size before surgery. Predicting response to NAC could reduce toxicity and delays to effective intervention. Computational analysis of dynamic contrast-enhanced magnetic resonance images (DCE-MRI) through deep convolution neural network (CNN) has shown a ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02209-9

    authors: El Adoui M,Drisis S,Benjelloun M

    更新日期:2020-09-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00