Abstract:
PURPOSE:Most software systems for oral implantology are based on a two-dimensional multi-view approach, often accompanied with a surface rendered model. Usually they are affected by common errors like anisotropy of the volume and distortion on measurements. A more integrated and realistic 3D approach for implant surgery is desirable in order to gain a deeper and surer knowledge of patient's anatomy before inserting the implants, thus reducing the risk of damaging surrounding structures. METHODS:We present a 3D software system for oral implant planning where computer graphic techniques have been used to create a smooth and user-friendly fully integrated 3D environment to work in. Both volume isotropy and correctness in measurements are obtained through slices interpolation to achieve, respectively, an isotropic voxel and the freedom of choosing arbitrarily, during the planning, the best cross-sectional plane. Correct orientation of the planned implants is also easily computed, by exploiting a radiological mask with radio-opaque markers, worn by the patient during the CT scan. RESULTS:Precision in measures was validated by considering several different scans and comparing the measures achieved with the ones got through the common methodology. It has been also calculated error percentages, algorithms efficiencies, and performances. Precision achieved outperforms usual DentaScan multi-view approach one, and it is comparable with or better than that obtained by the DentalVox tool (from 0.16 to 0.71% error in measures). CONCLUSIONS:The proposed software system provides a user-friendly, correct and precise work context for oral implant planning, avoiding similar software common errors. The 3D environment can be also exploited in the final surgical phase, in order to provide a flapless surgical guide, through the use of an anthropomorphic robot.
journal_name
Int J Comput Assist Radiol Surgauthors
Chiarelli T,Lamma E,Sansoni Tdoi
10.1007/s11548-009-0394-ysubject
Has Abstractpub_date
2010-01-01 00:00:00pages
57-67issue
1eissn
1861-6410issn
1861-6429journal_volume
5pub_type
杂志文章abstract:PURPOSE:Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reali...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0425-8
更新日期:2010-07-01 00:00:00
abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 已发布勘误
doi:10.1007/s11548-020-02119-w
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0921-8
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:Image registration lies in the core of augmented reality (AR), which aligns the virtual scene with the reality. In AR surgical navigation, the performance of image registration is vital to the surgical outcome. METHODS:This paper presents a practical marker-less image registration method for AR-guided oral ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01921-5
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1819-2
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:We present a platform, GRAphical Pipeline Environment (GRAPE), to facilitate the development of patient-adaptive magnetic resonance imaging (MRI) protocols. METHODS:GRAPE is an open-source project implemented in the Qt C++ framework to enable graphical creation, execution, and debugging of real-time image anal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1495-z
更新日期:2017-03-01 00:00:00
abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01950-0
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0659-0
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:In this paper, we investigate a framework for interactive brain tumor segmentation which, at its core, treats the problem of interactive brain tumor segmentation as a machine learning problem. METHODS:This method has an advantage over typical machine learning methods for this task where generalization is made ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1311-1
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:An optoelectronic surgical navigation system was used to detect small but measurable translational motion of human hip cadavers in high-range passive motions. Kinematic data were also examined to demonstrate the role of soft tissues in constraining hip translation. METHODS:Twelve cadaver hips were scanned usin...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1629-y
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1309-8
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0957-9
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02029-6
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1113-x
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Knee arthroscopy suffers from a lack of depth information and easy occlusion of the visual field. To solve these limitations, we propose an arthroscopic navigation system based on self-positioning technology, with the guidance of virtual-vision views. This system can work without any external tracking devices o...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02099-6
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0958-8
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS:We present a novel appr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1798-3
更新日期:2018-09-01 00:00:00
abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1282-2
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:In the past decade, augmented reality systems have been expected to support surgical operations by making it possible to view invisible objects that are inside or occluded by the skull, hands, or organs. However, the properties of biological tissues that are non-rigid and featureless require a large number of d...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1458-4
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0383-1
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1409-0
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1759-x
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1752-4
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0997-9
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1538-0
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Twin-to-twin transfusion syndrome (TTTS) is a serious condition that occurs in about 10-15% of monochorionic twin pregnancies. In most instances, the blood flow is unevenly distributed throughout the placenta anastomoses leading to the death of both fetuses if no surgical procedure is performed. Fetoscopic lase...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02256-2
更新日期:2020-11-01 00:00:00
abstract:PURPOSE:Epilepsy is potentially curable with resective surgery if the epileptogenic zone (EZ) can be identified. If non-invasive imaging is unable to elucidate the EZ, intracranial electrodes may be implanted to identify the EZ as well as map cortical function. In current clinical practice, each electrode trajectory is...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1628-z
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0924-5
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01935-z
更新日期:2019-08-01 00:00:00
abstract:PURPOSE:We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). METHODS:The method is based on superpixel technique and classification of each supe...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1483-3
更新日期:2017-02-01 00:00:00