Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Abstract:

PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically identify and reduce artifacts in cine 4DCT images. METHODS:We proposed an algorithm that consisted of two main stages: deformable image registration and respiratory motion simulation. Specifically, each 4DCT phase image was registered to the breath-holding CT image using the block-matching method, with erroneous spatial matches removed by the least median of squares filter and the full displacement vector field generated by the moving least squares interpolation. The lung's respiratory motion trajectory was then recovered from the displacement vector field using the parameterized polynomial function, with fitting parameters estimated by combinatorial optimization. In this way, artifacts were located according to deviations between image points and their motion trajectories and further corrected based on position prediction. RESULTS:The mean spatial error (standard deviation) was 1.00 (0.85) mm after registration as opposed to 6.96 (4.61) mm before registration. In addition, we took human observation conducted by medical experts as the gold standard. The average sensitivity, specificity, and accuracy of the proposed method in artifact identification were 0.97, 0.84, and 0.89, respectively. CONCLUSIONS:The proposed method identified and reduced artifacts accurately and automatically, providing an alternative way to analyze 4DCT image quality and to correct problematic images for radiation therapy.

authors

Li M,Castillo SJ,Castillo R,Castillo E,Guerrero T,Xiao L,Zheng X

doi

10.1007/s11548-017-1538-0

subject

Has Abstract

pub_date

2017-09-01 00:00:00

pages

1521-1532

issue

9

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-017-1538-0

journal_volume

12

pub_type

杂志文章
  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Cost-effective, personalized, 3D-printed liver model for preoperative planning before laparoscopic liver hemihepatectomy for colorectal cancer metastases.

    abstract:PURPOSE:Three-dimensional (3D) printing for preoperative planning has been intensively developed in the recent years. However, the implementation of these solutions in hospitals is still difficult due to high costs, extremely expensive industrial-grade printers, and software that is difficult to obtain and learn along ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1527-3

    authors: Witowski JS,Pędziwiatr M,Major P,Budzyński A

    更新日期:2017-12-01 00:00:00

  • Computational modeling of abdominal hernia laparoscopic repair with a surgical mesh.

    abstract:PURPOSE:Although new techniques and prostheses have been introduced in ventral hernia surgery, abdominal hernia repair still presents complications, such as recurrence, pain, and discomfort. Thus, this work implements a computational method aimed at evaluating biomechanical aspects of the abdominal hernia laparoscopic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1681-7

    authors: Todros S,Pachera P,Baldan N,Pavan PG,Pianigiani S,Merigliano S,Natali AN

    更新日期:2018-01-01 00:00:00

  • Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

    abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0548-6

    authors: Weil YA,Liebergall M,Mosheiff R,Singer SB,Joskowicz L,Khoury A

    更新日期:2011-09-01 00:00:00

  • Formal verification of software-based medical devices considering medical guidelines.

    abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0919-2

    authors: Daw Z,Cleaveland R,Vetter M

    更新日期:2014-01-01 00:00:00

  • Altered brain anatomical networks and disturbed connection density in brain tumor patients revealed by diffusion tensor tractography.

    abstract:PURPOSE:Brain tumor patients are usually accompanied by impairments in cognitive functions, and these dysfunctions arise from the altered diffusion tensor of water molecules and disrupted neuronal conduction in white matter. Diffusion tensor imaging (DTI) is a powerful noninvasive imaging technique that can reflect dif...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1330-y

    authors: Yu Z,Tao L,Qian Z,Wu J,Liu H,Yu Y,Song J,Wang S,Sun J

    更新日期:2016-11-01 00:00:00

  • Ultrasound thermal monitoring with an external ultrasound source for customized bipolar RF ablation shapes.

    abstract:PURPOSE:Thermotherapy is a clinical procedure which delivers thermal energy to a target, and it has been applied for various medical treatments. Temperature monitoring during thermotherapy is important to achieve precise and reproducible results. Medical ultrasound can be used for thermal monitoring and is an attractiv...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1744-4

    authors: Kim Y,Audigier C,Ziegle J,Friebe M,Boctor EM

    更新日期:2018-06-01 00:00:00

  • Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

    abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0921-8

    authors: Qian K,Ando T,Nakamura K,Liao H,Kobayashi E,Yahagi N,Sakuma I

    更新日期:2014-03-01 00:00:00

  • Automatic detection of perforator vessels using infrared thermography in reconstructive surgery.

    abstract:PURPOSE:Knowing the location of the blood vessels supplying the skin and subcutaneous tissue is a requirement during the planning of tissue transfer in reconstructive surgery. Commonly used imaging techniques such as computed tomography angiography and indocyanine green angiography expose the patient to radiation or a ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1892-6

    authors: Unger M,Markfort M,Halama D,Chalopin C

    更新日期:2019-03-01 00:00:00

  • Improved medical image fusion based on cascaded PCA and shift invariant wavelet transforms.

    abstract:PURPOSE:In the medical field, radiologists need more informative and high-quality medical images to diagnose diseases. Image fusion plays a vital role in the field of biomedical image analysis. It aims to integrate the complementary information from multimodal images, producing a new composite image which is expected t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1692-4

    authors: Reena Benjamin J,Jayasree T

    更新日期:2018-02-01 00:00:00

  • Automatic abdominal multi-organ segmentation using deep convolutional neural network and time-implicit level sets.

    abstract:PURPOSE:Multi-organ segmentation from CT images is an essential step for computer-aided diagnosis and surgery planning. However, manual delineation of the organs by radiologists is tedious, time-consuming and poorly reproducible. Therefore, we propose a fully automatic method for the segmentation of multiple organs fro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1501-5

    authors: Hu P,Wu F,Peng J,Bao Y,Chen F,Kong D

    更新日期:2017-03-01 00:00:00

  • Robust and semantic needle detection in 3D ultrasound using orthogonal-plane convolutional neural networks.

    abstract:PURPOSE:During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS:We present a novel appr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1798-3

    authors: Pourtaherian A,Ghazvinian Zanjani F,Zinger S,Mihajlovic N,Ng GC,Korsten HHM,de With PHN

    更新日期:2018-09-01 00:00:00

  • Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography.

    abstract:PURPOSE:A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. MATERIALS AND METHODS:Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRAD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0300-7

    authors: Destounis S,Hanson S,Morgan R,Murphy P,Somerville P,Seifert P,Andolina V,Arieno A,Skolny M,Logan-Young W

    更新日期:2009-06-01 00:00:00

  • Anatomy-driven multiple trajectory planning (ADMTP) of intracranial electrodes for epilepsy surgery.

    abstract:PURPOSE:Epilepsy is potentially curable with resective surgery if the epileptogenic zone (EZ) can be identified. If non-invasive imaging is unable to elucidate the EZ, intracranial electrodes may be implanted to identify the EZ as well as map cortical function. In current clinical practice, each electrode trajectory is...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1628-z

    authors: Sparks R,Vakharia V,Rodionov R,Vos SB,Diehl B,Wehner T,Miserocchi A,McEvoy AW,Duncan JS,Ourselin S

    更新日期:2017-08-01 00:00:00

  • Learned optical flow for intra-operative tracking of the retinal fundus.

    abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02160-9

    authors: Ravasio CS,Pissas T,Bloch E,Flores B,Jalali S,Stoyanov D,Cardoso JM,Da Cruz L,Bergeles C

    更新日期:2020-05-01 00:00:00

  • A novel image-based retrieval system for characterization of maxillofacial lesions in cone beam CT images.

    abstract:PURPOSE:The objective of medical content-based image retrieval (CBIR) is to assist clinicians in decision making by retrieving the most similar cases to a given query image from a large database. Herein, a new method for content-based image retrieval of cone beam CT (CBCT) scans is presented. METHODS:The introduced fr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01946-w

    authors: Abdolali F,Zoroofi RA,Otake Y,Sato Y

    更新日期:2019-05-01 00:00:00

  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Interactive navigation of segmented MR angiograms using simultaneous curved planar and volume visualizations.

    abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0534-4

    authors: van Schooten BW,van Dijk EM,Suinesiaputra A,Reiber JH

    更新日期:2011-09-01 00:00:00

  • Automated pulmonary nodule CT image characterization in lung cancer screening.

    abstract:PURPOSE:In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malign...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1245-7

    authors: Reeves AP,Xie Y,Jirapatnakul A

    更新日期:2016-01-01 00:00:00

  • Automated aorta segmentation in low-dose chest CT images.

    abstract:PURPOSE:Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0924-5

    authors: Xie Y,Padgett J,Biancardi AM,Reeves AP

    更新日期:2014-03-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • Use the force: deformation correction in robotic 3D ultrasound.

    abstract:PURPOSE:Ultrasound acquisitions are typically affected by deformations due to the pressure applied onto the contact surface. While a certain amount of pressure is necessary to ensure good acoustic coupling and visibility of the anatomy under examination, the caused deformations hinder accurate localization and geometri...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1716-8

    authors: Virga S,Göbl R,Baust M,Navab N,Hennersperger C

    更新日期:2018-05-01 00:00:00

  • Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions.

    abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02226-8

    authors: Li X,Young AS,Raman SS,Lu DS,Lee YH,Tsao TC,Wu HH

    更新日期:2020-10-01 00:00:00

  • A visual odometry base-tracking system for intraoperative C-arm guidance.

    abstract:PURPOSE:C-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view ima...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02229-5

    authors: Haliburton L,Esfandiari H,Guy P,Anglin C,Hodgson A

    更新日期:2020-10-01 00:00:00

  • Robotic laser osteotomy through penscriptive structured light visual servoing.

    abstract:PURPOSE:Planning osteotomies is a task that surgeons do as part of standard surgical workflow. This task, however, becomes more difficult and less intuitive when a robot is tasked with performing the osteotomy. In this study, we aim to provide a new method for surgeons to allow for highly intuitive trajectory planning,...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01905-x

    authors: Jivraj J,Deorajh R,Lai P,Chen C,Nguyen N,Ramjist J,Yang VXD

    更新日期:2019-05-01 00:00:00

  • Interactive determination of robust safety margins for oncologic liver surgery.

    abstract:OBJECTIVE:Complex oncologic interventions in the liver require an extensive and careful preoperative analysis. Particularly the achievement of an optimal safety margin around tumors remains a difficult task for surgeons. METHODS:We present new methods for evaluating different safety margins and their effect on the ass...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0359-1

    authors: Hansen C,Zidowitz S,Hindennach M,Schenk A,Hahn H,Peitgen HO

    更新日期:2009-09-01 00:00:00

  • Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1740-8

    authors: Granados A,Vakharia V,Rodionov R,Schweiger M,Vos SB,O'Keeffe AG,Li K,Wu C,Miserocchi A,McEvoy AW,Clarkson MJ,Duncan JS,Sparks R,Ourselin S

    更新日期:2018-06-01 00:00:00

  • Endoscopic scene labelling and augmentation using intraoperative pulsatile motion and colour appearance cues with preoperative anatomical priors.

    abstract:PURPOSE:Despite great advances in medical image segmentation, the accurate and automatic segmentation of endoscopic scenes remains a challenging problem. Two important aspects have to be considered in segmenting an endoscopic scene: (1) noise and clutter due to light reflection and smoke from cutting tissue, and (2) st...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1331-x

    authors: Nosrati MS,Amir-Khalili A,Peyrat JM,Abinahed J,Al-Alao O,Al-Ansari A,Abugharbieh R,Hamarneh G

    更新日期:2016-08-01 00:00:00

  • Patient-specific estimation of detailed cochlear shape from clinical CT images.

    abstract:PURPOSE:A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detai...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1701-7

    authors: Kjer HM,Fagertun J,Wimmer W,Gerber N,Vera S,Barazzetti L,Mangado N,Ceresa M,Piella G,Stark T,Stauber M,Reyes M,Weber S,Caversaccio M,González Ballester MÁ,Paulsen RR

    更新日期:2018-03-01 00:00:00