A preregistered STAMP method for image-guided temporal bone surgery.

Abstract:

OBJECTIVES:Image-guided otological surgeries require minimal invasiveness and high accuracy, and these two factors usually compete with each other. Our recently developed registration method, called the STAMP method, showed minimal invasiveness with accuracy comparable to that of the current more invasive registration methods used in image-guided temporal bone surgery. However, surgeons perceived the STAMP method as complex and time-consuming. METHODS:We modified our STAMP method to further simplify the surgeon's tasks in the operating room. We attached an optical tracking target on the STAMP plate and registered the plate in an IGS system before surgery, outside the operating room. The registration was completed in the operating room by finishing the final simple task, which was to hold the preregistered STAMP plate still on the patient's temporal bone. We tested this modified preregistered STAMP method in simulation surgery and actual surgeries. The registration times and errors of the STAMP method and preregistered STAMP method were compared. RESULTS:The proposed new preregistered STAMP method significantly reduced the registration time in the operating room without compromising the registration accuracy. CONCLUSIONS:The preregistered STAMP method significantly improved the original STAMP method in terms of time and convenience. It is now considered to be one of the easiest and quickest registrations for image-guided temporal bone surgery. Because most of the critical processes of registration can be completed in the laboratory, the registration task in the operating room is therefore greatly simplified, thus allowing surgeons to concentrate more on the surgery itself.

authors

Oka M,Cho B,Matsumoto N,Hong J,Jinnouchi M,Ouchida R,Komune S,Hashizume M

doi

10.1007/s11548-013-0916-5

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

119-26

issue

1

eissn

1861-6410

issn

1861-6429

journal_volume

9

pub_type

杂志文章
  • Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

    abstract:PURPOSE:Epidural and spinal needle insertions, as well as facet joint denervation and injections are widely performed procedures on the lumbar spine for delivering anesthesia and analgesia. Ultrasound (US)-based approaches have gained popularity for accurate needle placement, as they use a non-ionizing, inexpensive and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1552-2

    authors: Behnami D,Sedghi A,Anas EMA,Rasoulian A,Seitel A,Lessoway V,Ungi T,Yen D,Osborn J,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2017-06-01 00:00:00

  • Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

    abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1590-9

    authors: Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

    更新日期:2017-07-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • A statistical shape model of the human second cervical vertebra.

    abstract:PURPOSE:Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the sh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1121-x

    authors: Clogenson M,Duff JM,Luethi M,Levivier M,Meuli R,Baur C,Henein S

    更新日期:2015-07-01 00:00:00

  • Articular surface remodeling of the hip after periacetabular osteotomy.

    abstract:PURPOSE:Periacetabular osteotomies are a family of surgical procedures used to treat hip dysplasia. In a periacetabular osteotomy, the operating surgeon aims to increase acetabular coverage of the femoral head. The surgical correction has mechanical goals of increasing the stability of the joint and to improving the pr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0641-x

    authors: Rasquinha BJ,Sayani J,Rudan JF,Wood GC,Ellis RE

    更新日期:2012-03-01 00:00:00

  • Accurate two-dimensional cardiac strain calculation using adaptive windowed Fourier transform and Gabor wavelet transform.

    abstract:PURPOSE:Cardiac strain calculated from tagged magnetic resonance (MR) images provides clinicians information about abnormalities of heart-wall motion in patients. It is important to develop an accurate method to determine the cardiac strain efficiently. An adaptive windowed harmonic phase (AWHARP) method is proposed fo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0689-2

    authors: Fu YB,Chui CK,Teo CL

    更新日期:2013-01-01 00:00:00

  • A projected landmark method for reduction of registration error in image-guided surgery systems.

    abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1075-z

    authors: Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SM

    更新日期:2015-05-01 00:00:00

  • Image-based laparoscopic bowel measurement.

    abstract:PURPOSE:Minimally invasive interventions offer benefits for patients, while also entailing drawbacks for surgeons, such as the loss of depth perception. Thus estimating distances, which is of particular importance in gastric bypasses, becomes difficult. In this paper, we propose an approach based on stereo endoscopy th...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1291-1

    authors: Bodenstedt S,Wagner M,Mayer B,Stemmer K,Kenngott H,Müller-Stich B,Dillmann R,Speidel S

    更新日期:2016-03-01 00:00:00

  • Automatic 3D liver location and segmentation via convolutional neural network and graph cut.

    abstract:PURPOSE:Segmentation of the liver from abdominal computed tomography (CT) images is an essential step in some computer-assisted clinical interventions, such as surgery planning for living donor liver transplant, radiotherapy and volume measurement. In this work, we develop a deep learning algorithm with graph cut refin...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1467-3

    authors: Lu F,Wu F,Hu P,Peng Z,Kong D

    更新日期:2017-02-01 00:00:00

  • Comparison of different grid of tags detection methods in tagged cardiac MR imaging.

    abstract:PURPOSE:Non-invasive imaging assessment of cardiac function is important in cardiovascular disease diagnosis, especially for evaluation of local cardiac motion. Tagged cardiac MRI has been developed for this purpose, but evaluation of the results requires quantification and automation. METHODS:Two methods utilizing ac...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0495-7

    authors: Histace A,Portefaix C,Matuszewski B

    更新日期:2011-03-01 00:00:00

  • MINARO HD: control and evaluation of a handheld, highly dynamic surgical robot.

    abstract:PURPOSE:Current surgical robotic systems are either large serial arms, resulting in higher risks due to their high inertia and no inherent limitations of the working space, or they are bone-mounted, adding substantial additional task steps to the surgical workflow. The robot presented in this paper has a handy and ligh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02306-9

    authors: Vossel M,Müller M,Niesche A,Theisgen L,Radermacher K,de la Fuente M

    更新日期:2021-01-23 00:00:00

  • Generative multi-adversarial network for striking the right balance in abdominal image segmentation.

    abstract::Purpose The identification of abnormalities that are relatively rare within otherwise normal anatomy is a major challenge for deep learning in the semantic segmentation of medical images. The small number of samples of the minority classes in the training data makes the learning of optimal classification challenging, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02254-4

    authors: Rezaei M,Näppi JJ,Lippert C,Meinel C,Yoshida H

    更新日期:2020-11-01 00:00:00

  • Optimal setting of image bounding box can improve registration accuracy of diffusion tensor tractography.

    abstract:PURPOSE:When we register diffusion tensor tractography (DTT) to anatomical images such as fast imaging employing steady-state acquisition (FIESTA), we register the B0 image to FIESTA. Precise registration of the DTT B0 image to FIESTA is possible with non-rigid registration compared to rigid registration, although the ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0934-3

    authors: Yoshino M,Kin T,Saito T,Nakagawa D,Nakatomi H,Kunimatsu A,Oyama H,Saito N

    更新日期:2013-08-20 00:00:00

  • Robust calculation of the midsagittal plane in CT scans using the Kullback-Leibler's measure.

    abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0366-2

    authors: Puspitasari F,Volkau I,Ambrosius W,Nowinski WL

    更新日期:2009-11-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases.

    abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02218-8

    authors: Geng J,Hu P,Ji Z,Li C,Li L,Shen J,Feng X,Wang W,Yang G,Li J,Zhang H

    更新日期:2020-10-01 00:00:00

  • Formal verification of software-based medical devices considering medical guidelines.

    abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0919-2

    authors: Daw Z,Cleaveland R,Vetter M

    更新日期:2014-01-01 00:00:00

  • Hybrid simulation using mixed reality for interventional ultrasound imaging training.

    abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1113-x

    authors: Freschi C,Parrini S,Dinelli N,Ferrari M,Ferrari V

    更新日期:2015-07-01 00:00:00

  • On-patient see-through augmented reality based on visual SLAM.

    abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1444-x

    authors: Mahmoud N,Grasa ÓG,Nicolau SA,Doignon C,Soler L,Marescaux J,Montiel JM

    更新日期:2017-01-01 00:00:00

  • Accuracy analysis in MRI-guided robotic prostate biopsy.

    abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0831-9

    authors: Xu H,Lasso A,Guion P,Krieger A,Kaushal A,Singh AK,Pinto PA,Coleman J,Grubb RL 3rd,Lattouf JB,Menard C,Whitcomb LL,Fichtinger G

    更新日期:2013-11-01 00:00:00

  • MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

    abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0964-x

    authors: Yiallouras C,Mylonas N,Damianou C

    更新日期:2014-07-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Learned optical flow for intra-operative tracking of the retinal fundus.

    abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02160-9

    authors: Ravasio CS,Pissas T,Bloch E,Flores B,Jalali S,Stoyanov D,Cardoso JM,Da Cruz L,Bergeles C

    更新日期:2020-05-01 00:00:00

  • A Survey of auditory display in image-guided interventions.

    abstract:PURPOSE:This article investigates the current state of the art of the use of auditory display in image-guided medical interventions. Auditory display is a means of conveying information using sound, and we review the use of this approach to support navigated interventions. We discuss the benefits and drawbacks of publi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-017-1547-z

    authors: Black D,Hansen C,Nabavi A,Kikinis R,Hahn H

    更新日期:2017-10-01 00:00:00

  • Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study.

    abstract:PURPOSE:Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0997-9

    authors: Kobler JP,Schoppe M,Lexow GJ,Rau TS,Majdani O,Kahrs LA,Ortmaier T

    更新日期:2014-11-01 00:00:00

  • Multi-input deep learning architecture for predicting breast tumor response to chemotherapy using quantitative MR images.

    abstract:PURPOSE:Neoadjuvant chemotherapy (NAC) aims to minimize the tumor size before surgery. Predicting response to NAC could reduce toxicity and delays to effective intervention. Computational analysis of dynamic contrast-enhanced magnetic resonance images (DCE-MRI) through deep convolution neural network (CNN) has shown a ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02209-9

    authors: El Adoui M,Drisis S,Benjelloun M

    更新日期:2020-09-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1282-2

    authors: Chen X,Cheng J,Gu X,Sun Y,Politis C

    更新日期:2016-04-01 00:00:00

  • Planning and simulation of microsurgical laser bone ablation.

    abstract:PURPOSE:Laser ablation of hard tissue is not completely understood until now and not modeled for computer-assisted microsurgery. A precise planning and simulation is an essential step toward the usage of microsurgical laser bone ablation in the operating room. METHODS:Planning the volume for laser bone ablation is bas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0303-4

    authors: Kahrs LA,Burgner J,Klenzner T,Raczkowsky J,Schipper J,Wörn H

    更新日期:2010-03-01 00:00:00

  • Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

    abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1538-0

    authors: Li M,Castillo SJ,Castillo R,Castillo E,Guerrero T,Xiao L,Zheng X

    更新日期:2017-09-01 00:00:00