Articular surface remodeling of the hip after periacetabular osteotomy.

Abstract:

PURPOSE:Periacetabular osteotomies are a family of surgical procedures used to treat hip dysplasia. In a periacetabular osteotomy, the operating surgeon aims to increase acetabular coverage of the femoral head. The surgical correction has mechanical goals of increasing the stability of the joint and to improving the pressure distribution across the acetabulum. Although it is known that bone will remodel under changing load at the microstructural level, it is unclear whether there is any gross remodeling of the acetabulum or the femoral head in response to the change in loading following a periacetabular osteotomy. This observational study aims to quantify the shape of operative and contralateral hip joint surfaces pre and postoperatively to determine whether there are gross morphological changes in the shape of any of the bony articular surfaces of the joint. METHODS:Preoperative and postoperative computed tomography (CT) scans were segmented as triangulated meshes. The bony articular surfaces of these meshes were then isolated. The vertices of these surfaces were fit to spheres and to general ellipsoids and, in the case of the acetabulum, examined in anatomical coordinate frames to look for changes between pre and postoperative segmentations. RESULTS:Spherical fit results were consistent preoperatively and postoperatively, with small changes in the radii of the spheres of best fit for both operative and nonoperative hips. Ellipsoid fitting showed variations between preoperative and postoperative scans in both eccentricity and orientation. CONCLUSIONS:Because there is no clear evidence of gross articular surface remodeling, periacetabular osteotomy for an adult should be planned with the expectation that the patient's existing articular structure will be preserved.

authors

Rasquinha BJ,Sayani J,Rudan JF,Wood GC,Ellis RE

doi

10.1007/s11548-011-0641-x

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

241-8

issue

2

eissn

1861-6410

issn

1861-6429

journal_volume

7

pub_type

杂志文章
  • Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

    abstract:PURPOSE:Epidural and spinal needle insertions, as well as facet joint denervation and injections are widely performed procedures on the lumbar spine for delivering anesthesia and analgesia. Ultrasound (US)-based approaches have gained popularity for accurate needle placement, as they use a non-ionizing, inexpensive and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1552-2

    authors: Behnami D,Sedghi A,Anas EMA,Rasoulian A,Seitel A,Lessoway V,Ungi T,Yen D,Osborn J,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2017-06-01 00:00:00

  • Pre-clinical evaluation of an image-guided in-situ Raman spectroscopy navigation system for targeted prostate cancer interventions.

    abstract:PURPOSE:Transrectal ultrasound (TRUS) image guidance is the standard of care for diagnostic and therapeutic interventions in prostate cancer (PCa) patients, but can lead to high false-negative rates, compromising downstream effectiveness of therapeutic choices. A promising approach to improve in-situ detection of PCa l...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02136-9

    authors: Shams R,Picot F,Grajales D,Sheehy G,Dallaire F,Birlea M,Saad F,Trudel D,Menard C,Leblond F,Kadoury S

    更新日期:2020-05-01 00:00:00

  • GRAPE: a graphical pipeline environment for image analysis in adaptive magnetic resonance imaging.

    abstract:PURPOSE:We present a platform, GRAphical Pipeline Environment (GRAPE), to facilitate the development of patient-adaptive magnetic resonance imaging (MRI) protocols. METHODS:GRAPE is an open-source project implemented in the Qt C++ framework to enable graphical creation, execution, and debugging of real-time image anal...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1495-z

    authors: Gabr RE,Tefera GB,Allen WJ,Pednekar AS,Narayana PA

    更新日期:2017-03-01 00:00:00

  • Automatic detection of perforator vessels using infrared thermography in reconstructive surgery.

    abstract:PURPOSE:Knowing the location of the blood vessels supplying the skin and subcutaneous tissue is a requirement during the planning of tissue transfer in reconstructive surgery. Commonly used imaging techniques such as computed tomography angiography and indocyanine green angiography expose the patient to radiation or a ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1892-6

    authors: Unger M,Markfort M,Halama D,Chalopin C

    更新日期:2019-03-01 00:00:00

  • Planning of mandibular reconstructions based on statistical shape models.

    abstract:PURPOSE:The reconstruction of large continuity defects of the mandible is a challenging task, especially when the shape of the missing part is not known prior to operation. Today, the surgical planning is based mainly on visual judgment and the individual skills and experience of the surgeons. The objective of the curr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1451-y

    authors: Raith S,Wolff S,Steiner T,Modabber A,Weber M,Hölzle F,Fischer H

    更新日期:2017-01-01 00:00:00

  • Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1752-4

    authors: Graf EC,Ott I,Praceus J,Bourier F,Lueth TC

    更新日期:2018-06-01 00:00:00

  • Generative multi-adversarial network for striking the right balance in abdominal image segmentation.

    abstract::Purpose The identification of abnormalities that are relatively rare within otherwise normal anatomy is a major challenge for deep learning in the semantic segmentation of medical images. The small number of samples of the minority classes in the training data makes the learning of optimal classification challenging, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02254-4

    authors: Rezaei M,Näppi JJ,Lippert C,Meinel C,Yoshida H

    更新日期:2020-11-01 00:00:00

  • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0957-9

    authors: Amiri S,Wilson DR,Masri BA,Anglin C

    更新日期:2014-07-01 00:00:00

  • Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis.

    abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02087-w

    authors: Atehortúa A,Garreau M,Simon A,Donal E,Lederlin M,Romero E

    更新日期:2020-02-01 00:00:00

  • Patient-specific estimation of detailed cochlear shape from clinical CT images.

    abstract:PURPOSE:A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detai...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1701-7

    authors: Kjer HM,Fagertun J,Wimmer W,Gerber N,Vera S,Barazzetti L,Mangado N,Ceresa M,Piella G,Stark T,Stauber M,Reyes M,Weber S,Caversaccio M,González Ballester MÁ,Paulsen RR

    更新日期:2018-03-01 00:00:00

  • Ultrasound texture-based CAD system for detecting neuromuscular diseases.

    abstract:PURPOSE:Diagnosis of neuromuscular diseases in ultrasonography is a challenging task since experts are often unable to discriminate between healthy and pathological cases. A computer-aided diagnosis (CAD) system for skeletal muscle ultrasonography was developed and tested for myositis detection in ultrasound images of ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1133-6

    authors: König T,Steffen J,Rak M,Neumann G,von Rohden L,Tönnies KD

    更新日期:2015-09-01 00:00:00

  • Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm.

    abstract:PURPOSE:To evaluate the accuracy of three-dimensional cephalometric measurements obtained through an automatic landmark detection algorithm compared to those obtained through manual identification. METHODS:The study demonstrates a comparison of 51 cephalometric measurements (28 linear, 16 angles and 7 ratios) on 30 CB...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1334-7

    authors: Gupta A,Kharbanda OP,Sardana V,Balachandran R,Sardana HK

    更新日期:2016-07-01 00:00:00

  • Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases.

    abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02218-8

    authors: Geng J,Hu P,Ji Z,Li C,Li L,Shen J,Feng X,Wang W,Yang G,Li J,Zhang H

    更新日期:2020-10-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1740-8

    authors: Granados A,Vakharia V,Rodionov R,Schweiger M,Vos SB,O'Keeffe AG,Li K,Wu C,Miserocchi A,McEvoy AW,Clarkson MJ,Duncan JS,Sparks R,Ourselin S

    更新日期:2018-06-01 00:00:00

  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Regional infarction identification from cardiac CT images: a computer-aided biomechanical approach.

    abstract:PURPOSE:Regional infarction identification is important for heart disease diagnosis and management, and myocardial deformation has been shown to be effective for this purpose. Although tagged and strain-encoded MR images can provide such measurements, they are uncommon in clinical routine. On the contrary, cardiac CT i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-016-1404-5

    authors: Wong KC,Tee M,Chen M,Bluemke DA,Summers RM,Yao J

    更新日期:2016-09-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • Augmentation of haptic feedback for teleoperated robotic surgery.

    abstract:PURPOSE:A frequently mentioned lack of teleoperated surgical robots is the lack of haptic feedback. Haptics are not only able to mirror force information from the situs, but also to provide spatial guidance according to a surgical plan. However, superposition of the two haptic information can lead to overlapping and ma...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02118-x

    authors: Schleer P,Kaiser P,Drobinsky S,Radermacher K

    更新日期:2020-03-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • Fast and flexible distance measures for treatment planning.

    abstract:PURPOSE:Distance measures are required for diagnoses, therapy decision and documentation. With today's high-resolution CT and MR imaging techniques, high- quality images have become possible. Yet, manual measurement can be tedious. We present a method for automatically determining different distance-based measures on s...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0519-3

    authors: Rössling I,Cyrus C,Dornheim L,Boehm A,Preim B

    更新日期:2010-11-01 00:00:00

  • Optimal setting of image bounding box can improve registration accuracy of diffusion tensor tractography.

    abstract:PURPOSE:When we register diffusion tensor tractography (DTT) to anatomical images such as fast imaging employing steady-state acquisition (FIESTA), we register the B0 image to FIESTA. Precise registration of the DTT B0 image to FIESTA is possible with non-rigid registration compared to rigid registration, although the ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0934-3

    authors: Yoshino M,Kin T,Saito T,Nakagawa D,Nakatomi H,Kunimatsu A,Oyama H,Saito N

    更新日期:2013-08-20 00:00:00

  • Preliminary study on magnetic tracking-based planar shape sensing and navigation for flexible surgical robots in transoral surgery: methods and phantom experiments.

    abstract:PURPOSE:Flexible surgical robot can work in confined and complex environments, which makes it a good option for minimally invasive surgery. In order to utilize flexible manipulators in complicated and constrained surgical environments, it is of great significance to monitor the position and shape of the curvilinear man...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1672-8

    authors: Song S,Zhang C,Liu L,Meng MQ

    更新日期:2018-02-01 00:00:00

  • Orbital volume analysis: validation of a semi-automatic software segmentation method.

    abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1254-6

    authors: Jansen J,Schreurs R,Dubois L,Maal TJ,Gooris PJ,Becking AG

    更新日期:2016-01-01 00:00:00

  • BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1603-8

    authors: Chen D,Chen W,Huang L,Feng X,Peters T,Gu L

    更新日期:2017-09-01 00:00:00

  • A method for going from 2D laparoscope to 3D acquisition of surface landmarks by a novel computer vision approach.

    abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1655-9

    authors: Garbey M,Nguyen TB,Huang AY,Fikfak V,Dunkin BJ

    更新日期:2018-02-01 00:00:00

  • Unravelling the effect of data augmentation transformations in polyp segmentation.

    abstract:PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of differen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02262-4

    authors: Sánchez-Peralta LF,Picón A,Sánchez-Margallo FM,Pagador JB

    更新日期:2020-12-01 00:00:00

  • Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery.

    abstract:PURPOSE:The objective of this work is to develop a preoperative reconstruction plate design system for unilateral pelvic and acetabular fracture reduction and internal fixation surgery, using computer graphics and augmented reality (AR) techniques, in order to respect the patient-specific morphology and to reduce surgi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0775-5

    authors: Shen F,Chen B,Guo Q,Qi Y,Shen Y

    更新日期:2013-03-01 00:00:00

  • Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT.

    abstract:PURPOSE:Accurate target delineation is a critical step in radiotherapy. In this study, a robust contour propagation method is proposed to help physicians delineate lung tumors in four-dimensional computer tomography (4D-CT) images efficiently and accurately. METHODS:The proposed method starts with manually delineated ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1457-5

    authors: Liu Y,Jin R,Chen M,Song E,Xu X,Zhang S,Hung CC

    更新日期:2016-12-01 00:00:00

  • Robust calculation of the midsagittal plane in CT scans using the Kullback-Leibler's measure.

    abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0366-2

    authors: Puspitasari F,Volkau I,Ambrosius W,Nowinski WL

    更新日期:2009-11-01 00:00:00