Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm.

Abstract:

PURPOSE:To evaluate the accuracy of three-dimensional cephalometric measurements obtained through an automatic landmark detection algorithm compared to those obtained through manual identification. METHODS:The study demonstrates a comparison of 51 cephalometric measurements (28 linear, 16 angles and 7 ratios) on 30 CBCT (cone beam computed tomography) images. The analysis was performed to compare measurements based on 21 cephalometric landmarks detected automatically and those identified manually by three observers. RESULTS:Inter-observer ICC for each landmark was found to be excellent ([Formula: see text]) among three observers. The unpaired t-test revealed that there was no statistically significant difference in the measurements based on automatically detected and manually identified landmarks. The difference between the manual and automatic observation for each measurement was reported as an error. The highest mean error in the linear and angular measurements was found to be 2.63 mm ([Formula: see text] distance) and [Formula: see text] ([Formula: see text]-Me angle), respectively. The highest mean error in the group of distance ratios was 0.03 (for N-Me/N-ANS and [Formula: see text]). CONCLUSION:Cephalometric measurements computed from automatic detection of landmarks on 3D CBCT image were as accurate as those computed from manual identification.

authors

Gupta A,Kharbanda OP,Sardana V,Balachandran R,Sardana HK

doi

10.1007/s11548-015-1334-7

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

1297-309

issue

7

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-015-1334-7

journal_volume

11

pub_type

杂志文章
  • Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis.

    abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-0976-1

    authors: Krüger J,Ehrhardt J,Bischof A,Handels H

    更新日期:2014-05-01 00:00:00

  • Decision support system for the planning of minimally invasive aortic valve replacement surgery.

    abstract:PURPOSE:Minimally invasive aortic valve replacement (MIAVR) procedures remain more complex and technically challenging compared to conventional full sternotomy surgery. This technique involves a restricted surgical field and a limited workspace, which is, at present, strictly reserved for the most experienced surgeons....

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1725-7

    authors: Li H,Castro M,Haigron P,Verhoye JP,Ruggieri VG

    更新日期:2018-08-01 00:00:00

  • Breast tumor classification using different features of quantitative ultrasound parametric images.

    abstract:RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01908-8

    authors: Hsu SM,Kuo WH,Kuo FC,Liao YY

    更新日期:2019-04-01 00:00:00

  • Data-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms.

    abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1186-1

    authors: Twinanda AP,Alkan EO,Gangi A,de Mathelin M,Padoy N

    更新日期:2015-06-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Hybrid simulation using mixed reality for interventional ultrasound imaging training.

    abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1113-x

    authors: Freschi C,Parrini S,Dinelli N,Ferrari M,Ferrari V

    更新日期:2015-07-01 00:00:00

  • Patient-specific estimation of detailed cochlear shape from clinical CT images.

    abstract:PURPOSE:A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detai...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1701-7

    authors: Kjer HM,Fagertun J,Wimmer W,Gerber N,Vera S,Barazzetti L,Mangado N,Ceresa M,Piella G,Stark T,Stauber M,Reyes M,Weber S,Caversaccio M,González Ballester MÁ,Paulsen RR

    更新日期:2018-03-01 00:00:00

  • Construct and face validity of SINERGIA laparoscopic virtual reality simulator.

    abstract:PURPOSE:Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reali...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0425-8

    authors: Sánchez-Peralta LF,Sánchez-Margallo FM,Moyano-Cuevas JL,Pagador JB,Enciso-Sanz S,Sánchez-González P,Gómez-Aguilera EJ,Usón-Gargallo J

    更新日期:2010-07-01 00:00:00

  • Breast masses detection using phase portrait analysis and fuzzy inference systems.

    abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0659-0

    authors: Mencattini A,Salmeri M

    更新日期:2012-07-01 00:00:00

  • Robust calculation of the midsagittal plane in CT scans using the Kullback-Leibler's measure.

    abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0366-2

    authors: Puspitasari F,Volkau I,Ambrosius W,Nowinski WL

    更新日期:2009-11-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • Knee arthroscopic navigation using virtual-vision rendering and self-positioning technology.

    abstract:PURPOSE:Knee arthroscopy suffers from a lack of depth information and easy occlusion of the visual field. To solve these limitations, we propose an arthroscopic navigation system based on self-positioning technology, with the guidance of virtual-vision views. This system can work without any external tracking devices o...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02099-6

    authors: Ma C,Cui X,Chen F,Ma L,Xin S,Liao H

    更新日期:2020-03-01 00:00:00

  • Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    abstract:PURPOSE:Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermog...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1683-5

    authors: Rathmann P,Chalopin C,Halama D,Giri P,Meixensberger J,Lindner D

    更新日期:2018-03-01 00:00:00

  • Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

    abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1590-9

    authors: Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

    更新日期:2017-07-01 00:00:00

  • Articular surface remodeling of the hip after periacetabular osteotomy.

    abstract:PURPOSE:Periacetabular osteotomies are a family of surgical procedures used to treat hip dysplasia. In a periacetabular osteotomy, the operating surgeon aims to increase acetabular coverage of the femoral head. The surgical correction has mechanical goals of increasing the stability of the joint and to improving the pr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0641-x

    authors: Rasquinha BJ,Sayani J,Rudan JF,Wood GC,Ellis RE

    更新日期:2012-03-01 00:00:00

  • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0957-9

    authors: Amiri S,Wilson DR,Masri BA,Anglin C

    更新日期:2014-07-01 00:00:00

  • MINARO HD: control and evaluation of a handheld, highly dynamic surgical robot.

    abstract:PURPOSE:Current surgical robotic systems are either large serial arms, resulting in higher risks due to their high inertia and no inherent limitations of the working space, or they are bone-mounted, adding substantial additional task steps to the surgical workflow. The robot presented in this paper has a handy and ligh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02306-9

    authors: Vossel M,Müller M,Niesche A,Theisgen L,Radermacher K,de la Fuente M

    更新日期:2021-01-23 00:00:00

  • Cost-effective, personalized, 3D-printed liver model for preoperative planning before laparoscopic liver hemihepatectomy for colorectal cancer metastases.

    abstract:PURPOSE:Three-dimensional (3D) printing for preoperative planning has been intensively developed in the recent years. However, the implementation of these solutions in hospitals is still difficult due to high costs, extremely expensive industrial-grade printers, and software that is difficult to obtain and learn along ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1527-3

    authors: Witowski JS,Pędziwiatr M,Major P,Budzyński A

    更新日期:2017-12-01 00:00:00

  • Planning nonlinear access paths for temporal bone surgery.

    abstract:PURPOSE:Interventions at the otobasis operate in the narrow region of the temporal bone where several highly sensitive organs define obstacles with minimal clearance for surgical instruments. Nonlinear trajectories for potential minimally invasive interventions can provide larger distances to risk structures and optimi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1712-z

    authors: Fauser J,Sakas G,Mukhopadhyay A

    更新日期:2018-05-01 00:00:00

  • BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1603-8

    authors: Chen D,Chen W,Huang L,Feng X,Peters T,Gu L

    更新日期:2017-09-01 00:00:00

  • Four-dimensional fully convolutional residual network-based liver segmentation in Gd-EOB-DTPA-enhanced MRI.

    abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01935-z

    authors: Takenaga T,Hanaoka S,Nomura Y,Nemoto M,Murata M,Nakao T,Miki S,Yoshikawa T,Hayashi N,Abe O

    更新日期:2019-08-01 00:00:00

  • A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

    abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1309-8

    authors: Fusaglia M,Hess H,Schwalbe M,Peterhans M,Tinguely P,Weber S,Lu H

    更新日期:2016-08-01 00:00:00

  • Automatic 3D liver location and segmentation via convolutional neural network and graph cut.

    abstract:PURPOSE:Segmentation of the liver from abdominal computed tomography (CT) images is an essential step in some computer-assisted clinical interventions, such as surgery planning for living donor liver transplant, radiotherapy and volume measurement. In this work, we develop a deep learning algorithm with graph cut refin...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1467-3

    authors: Lu F,Wu F,Hu P,Peng Z,Kong D

    更新日期:2017-02-01 00:00:00

  • Scaled, patient-specific 3D vertebral model reconstruction based on 2D lateral fluoroscopy.

    abstract:BACKGROUNDS:Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). An alternative...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0515-7

    authors: Zheng G,Nolte LP,Ferguson SJ

    更新日期:2011-05-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.

    abstract:PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficien...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1380-9

    authors: Mayer A,Zholkover A,Portnoy O,Raviv G,Konen E,Symon Z

    更新日期:2016-06-01 00:00:00

  • Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study.

    abstract:PURPOSE:To perform bronchoscopy safely and smoothly, it is very important to develop a bronchoscopic guidance system. Transbronchial lung biopsy (TBLB) with a bronchoscopic guidance system especially should permit safe image-guided procedures. Recently, electromagnetic tracking (EMT) is utilized to track the tip of the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0626-9

    authors: Deguchi D,Feuerstein M,Kitasaka T,Suenaga Y,Ide I,Murase H,Imaizumi K,Hasegawa Y,Mori K

    更新日期:2012-05-01 00:00:00