Scaled, patient-specific 3D vertebral model reconstruction based on 2D lateral fluoroscopy.

Abstract:

BACKGROUNDS:Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). An alternative method using 2D lateral fluoroscopy was developed. MATERIALS AND METHODS:A technique was developed to reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image and a statistical shape model of the lumbar vertebrae. Four cadaveric lumbar spine segments and two statistical shape models were used for testing. Reconstruction accuracy was determined by comparison of the surface models reconstructed from the single lateral fluoroscopic images to the ground truth data from 3D CT segmentation. For each case, two different surface-based registration techniques were used to recover the unknown scale factor, and the rigid transformation between the reconstructed surface model and the ground truth model before the differences between the two discrete surface models were computed. RESULTS:Successful reconstruction of scaled surface models was achieved for all test lumbar vertebrae based on single lateral fluoroscopic images. The mean reconstruction error was between 0.7 and 1.6 mm. CONCLUSIONS:A scaled, patient-specific surface model of the lumbar vertebra from a single lateral fluoroscopic image can be synthesized using the present approach. This new method for patient-specific 3D modeling has potential applications in spine kinematics analysis, surgical planning, and navigation.

authors

Zheng G,Nolte LP,Ferguson SJ

doi

10.1007/s11548-010-0515-7

subject

Has Abstract

pub_date

2011-05-01 00:00:00

pages

351-66

issue

3

eissn

1861-6410

issn

1861-6429

journal_volume

6

pub_type

杂志文章
  • Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1740-8

    authors: Granados A,Vakharia V,Rodionov R,Schweiger M,Vos SB,O'Keeffe AG,Li K,Wu C,Miserocchi A,McEvoy AW,Clarkson MJ,Duncan JS,Sparks R,Ourselin S

    更新日期:2018-06-01 00:00:00

  • BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1603-8

    authors: Chen D,Chen W,Huang L,Feng X,Peters T,Gu L

    更新日期:2017-09-01 00:00:00

  • Edge map analysis in chest X-rays for automatic pulmonary abnormality screening.

    abstract:PURPOSE:Our particular motivator is the need for screening HIV+ populations in resource-constrained regions for the evidence of tuberculosis, using posteroanterior chest radiographs (CXRs). METHOD:The proposed method is motivated by the observation that abnormal CXRs tend to exhibit corrupted and/or deformed thoracic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1359-6

    authors: Santosh KC,Vajda S,Antani S,Thoma GR

    更新日期:2016-09-01 00:00:00

  • Detection and modelling of contacts in explicit finite-element simulation of soft tissue biomechanics.

    abstract:PURPOSE:Realistic modelling of soft tissue biomechanics and mechanical interactions between tissues is an important part of biomechanically-informed surgical image-guidance and surgical simulation. This submission details a contact-modelling pipeline suitable for implementation in explicit matrix-free FEM solvers. Whil...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1142-5

    authors: Johnsen SF,Taylor ZA,Han L,Hu Y,Clarkson MJ,Hawkes DJ,Ourselin S

    更新日期:2015-11-01 00:00:00

  • Breast tumor classification using different features of quantitative ultrasound parametric images.

    abstract:RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01908-8

    authors: Hsu SM,Kuo WH,Kuo FC,Liao YY

    更新日期:2019-04-01 00:00:00

  • Computer-aided cephalometric landmark annotation for CBCT data.

    abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1453-9

    authors: Codari M,Caffini M,Tartaglia GM,Sforza C,Baselli G

    更新日期:2017-01-01 00:00:00

  • A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

    abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1309-8

    authors: Fusaglia M,Hess H,Schwalbe M,Peterhans M,Tinguely P,Weber S,Lu H

    更新日期:2016-08-01 00:00:00

  • MINARO HD: control and evaluation of a handheld, highly dynamic surgical robot.

    abstract:PURPOSE:Current surgical robotic systems are either large serial arms, resulting in higher risks due to their high inertia and no inherent limitations of the working space, or they are bone-mounted, adding substantial additional task steps to the surgical workflow. The robot presented in this paper has a handy and ligh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02306-9

    authors: Vossel M,Müller M,Niesche A,Theisgen L,Radermacher K,de la Fuente M

    更新日期:2021-01-23 00:00:00

  • Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography.

    abstract:PURPOSE:A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. MATERIALS AND METHODS:Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRAD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0300-7

    authors: Destounis S,Hanson S,Morgan R,Murphy P,Somerville P,Seifert P,Andolina V,Arieno A,Skolny M,Logan-Young W

    更新日期:2009-06-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Data-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms.

    abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1186-1

    authors: Twinanda AP,Alkan EO,Gangi A,de Mathelin M,Padoy N

    更新日期:2015-06-01 00:00:00

  • Dual-robot ultrasound-guided needle placement: closing the planning-imaging-action loop.

    abstract:PURPOSE:Precise needle placement is an important task during several medical procedures. Ultrasound imaging is often used to guide the needle toward the target region in soft tissue. This task remains challenging due to the user's dependence on image quality, limited field of view, moving target, and moving needle. In ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1408-1

    authors: Kojcev R,Fuerst B,Zettinig O,Fotouhi J,Lee SC,Frisch B,Taylor R,Sinibaldi E,Navab N

    更新日期:2016-06-01 00:00:00

  • Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

    abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1590-9

    authors: Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

    更新日期:2017-07-01 00:00:00

  • FCNN-based axon segmentation for convection-enhanced delivery optimization.

    abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01911-z

    authors: Vidotto M,De Momi E,Gazzara M,Mattos LS,Ferrigno G,Moccia S

    更新日期:2019-03-01 00:00:00

  • Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

    abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0548-6

    authors: Weil YA,Liebergall M,Mosheiff R,Singer SB,Joskowicz L,Khoury A

    更新日期:2011-09-01 00:00:00

  • Four-dimensional computed tomography angiography analysis of internal carotid arteries opacification at the skull base to detect delayed cerebral ischemia: a feasibility study.

    abstract:PURPOSE:Delayed cerebral ischemia represents a significant cause of poor functional outcome for patients with vasospasm after subarachnoid hemorrhage. We investigated whether delayed cerebral ischemia could be detected by the arterial opacification of internal carotid artery at the level of the skull base. METHODS:In ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02268-y

    authors: Ognard J,Cheddad El Aouni M,Dissaux B,Jomaah R,Rousseau PY,Burdin V,Ben Salem D,Gentric JC

    更新日期:2020-12-01 00:00:00

  • On-patient see-through augmented reality based on visual SLAM.

    abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1444-x

    authors: Mahmoud N,Grasa ÓG,Nicolau SA,Doignon C,Soler L,Marescaux J,Montiel JM

    更新日期:2017-01-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Breast masses detection using phase portrait analysis and fuzzy inference systems.

    abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0659-0

    authors: Mencattini A,Salmeri M

    更新日期:2012-07-01 00:00:00

  • Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

    abstract:PURPOSE:Epidural and spinal needle insertions, as well as facet joint denervation and injections are widely performed procedures on the lumbar spine for delivering anesthesia and analgesia. Ultrasound (US)-based approaches have gained popularity for accurate needle placement, as they use a non-ionizing, inexpensive and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1552-2

    authors: Behnami D,Sedghi A,Anas EMA,Rasoulian A,Seitel A,Lessoway V,Ungi T,Yen D,Osborn J,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2017-06-01 00:00:00

  • Projection-based visual guidance for robot-aided RF needle insertion.

    abstract:PURPOSE:The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0897-4

    authors: Wen R,Chui CK,Ong SH,Lim KB,Chang SK

    更新日期:2013-11-01 00:00:00

  • Preliminary study on magnetic tracking-based planar shape sensing and navigation for flexible surgical robots in transoral surgery: methods and phantom experiments.

    abstract:PURPOSE:Flexible surgical robot can work in confined and complex environments, which makes it a good option for minimally invasive surgery. In order to utilize flexible manipulators in complicated and constrained surgical environments, it is of great significance to monitor the position and shape of the curvilinear man...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1672-8

    authors: Song S,Zhang C,Liu L,Meng MQ

    更新日期:2018-02-01 00:00:00

  • Four-dimensional fully convolutional residual network-based liver segmentation in Gd-EOB-DTPA-enhanced MRI.

    abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01935-z

    authors: Takenaga T,Hanaoka S,Nomura Y,Nemoto M,Murata M,Nakao T,Miki S,Yoshikawa T,Hayashi N,Abe O

    更新日期:2019-08-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • Automatic phase prediction from low-level surgical activities.

    abstract:PURPOSE:Analyzing surgical activities has received a growing interest in recent years. Several methods have been proposed to identify surgical activities and surgical phases from data acquired in operating rooms. These context-aware systems have multiple applications including: supporting the surgical team during the i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1195-0

    authors: Forestier G,Riffaud L,Jannin P

    更新日期:2015-06-01 00:00:00

  • A projected landmark method for reduction of registration error in image-guided surgery systems.

    abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1075-z

    authors: Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SM

    更新日期:2015-05-01 00:00:00

  • A Survey of auditory display in image-guided interventions.

    abstract:PURPOSE:This article investigates the current state of the art of the use of auditory display in image-guided medical interventions. Auditory display is a means of conveying information using sound, and we review the use of this approach to support navigated interventions. We discuss the benefits and drawbacks of publi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-017-1547-z

    authors: Black D,Hansen C,Nabavi A,Kikinis R,Hahn H

    更新日期:2017-10-01 00:00:00

  • Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions.

    abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02226-8

    authors: Li X,Young AS,Raman SS,Lu DS,Lee YH,Tsao TC,Wu HH

    更新日期:2020-10-01 00:00:00

  • Force estimation from OCT volumes using 3D CNNs.

    abstract:PURPOSE:Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and ste...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1777-8

    authors: Gessert N,Beringhoff J,Otte C,Schlaefer A

    更新日期:2018-07-01 00:00:00

  • Image-based 3D modeling and validation of radiofrequency interstitial tumor ablation using a tissue-mimicking breast phantom.

    abstract:PURPOSE:Minimally invasive treatment of solid cancers, especially in the breast and liver, remains clinically challenging, despite a variety of treatment modalities, including radiofrequency ablation (RFA), microwave ablation or high-intensity focused ultrasound. Each treatment modality has advantages and disadvantages...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0769-3

    authors: Wang Z,Aarya I,Gueorguieva M,Liu D,Luo H,Manfredi L,Wang L,McLean D,Coleman S,Brown S,Cuschieri A

    更新日期:2012-11-01 00:00:00