Breast tumor classification using different features of quantitative ultrasound parametric images.

Abstract:

RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, by combining the above methods is expected to provide more clues for classifying breast tumors. MATERIALS AND METHODS:To verify the validity of the concept, raw data were obtained from 160 clinical cases. Six different types of morphological-feature parameters, four texture features, and the Nakagami parameter of benignancy and malignancy were extracted for evaluation. The Pearson's correlation matrix was used to calculate the correlation between different feature parameters. The fuzzy c-means clustering and stepwise regression techniques were utilized to determine the optimal feature set, respectively. The logistic regression, receiver operating characteristic curve, and support vector machine were used to estimate the diagnostic ability. RESULTS:The best performance was obtained by combining morphological-feature parameter (e.g., standard deviation of the shortest distance), texture feature (e.g., variance), and the Nakagami parameter, with an accuracy of 89.4%, a specificity of 86.3%, a sensitivity of 92.5%, and an area under receiver operating characteristic curve of 0.96. There was no significant difference between using fuzzy c-means clustering, logistic regression, and support vector machine based on the optimal feature set for breast tumors classification. CONCLUSION:Therefore, we verified that different physical ultrasonic features are functionally complementary and thus improve the performance in diagnosing breast tumors. Moreover, the optimal feature set had the maximum discriminating performance should be irrelative to the power of classifiers.

authors

Hsu SM,Kuo WH,Kuo FC,Liao YY

doi

10.1007/s11548-018-01908-8

subject

Has Abstract

pub_date

2019-04-01 00:00:00

pages

623-633

issue

4

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-018-01908-8

journal_volume

14

pub_type

杂志文章
  • MIDG-Emerging grid technologies for multi-site preclinical molecular imaging research communities.

    abstract:PURPOSE:Molecular imaging is the visualization and identification of specific molecules in anatomy for insight into metabolic pathways, tissue consistency, and tracing of solute transport mechanisms. This paper presents the Molecular Imaging Data Grid (MIDG) which utilizes emerging grid technologies in preclinical mole...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0524-6

    authors: Lee J,Documet J,Liu B,Park R,Tank A,Huang HK

    更新日期:2011-03-01 00:00:00

  • Anatomy-driven multiple trajectory planning (ADMTP) of intracranial electrodes for epilepsy surgery.

    abstract:PURPOSE:Epilepsy is potentially curable with resective surgery if the epileptogenic zone (EZ) can be identified. If non-invasive imaging is unable to elucidate the EZ, intracranial electrodes may be implanted to identify the EZ as well as map cortical function. In current clinical practice, each electrode trajectory is...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1628-z

    authors: Sparks R,Vakharia V,Rodionov R,Vos SB,Diehl B,Wehner T,Miserocchi A,McEvoy AW,Duncan JS,Ourselin S

    更新日期:2017-08-01 00:00:00

  • Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1752-4

    authors: Graf EC,Ott I,Praceus J,Bourier F,Lueth TC

    更新日期:2018-06-01 00:00:00

  • Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

    abstract:PURPOSE:Organ motion due to patient breathing introduces a technical challenge for dosimetry and lung tumor treatment by hadron therapy. Accurate dose distribution estimation requires patient-specific information on tumor position, size, and shape as well as information regarding the material density and stopping power...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0935-2

    authors: Manescu P,Ladjal H,Azencot J,Beuve M,Testa E,Shariat B

    更新日期:2014-05-01 00:00:00

  • Interactive determination of robust safety margins for oncologic liver surgery.

    abstract:OBJECTIVE:Complex oncologic interventions in the liver require an extensive and careful preoperative analysis. Particularly the achievement of an optimal safety margin around tumors remains a difficult task for surgeons. METHODS:We present new methods for evaluating different safety margins and their effect on the ass...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0359-1

    authors: Hansen C,Zidowitz S,Hindennach M,Schenk A,Hahn H,Peitgen HO

    更新日期:2009-09-01 00:00:00

  • Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography.

    abstract:PURPOSE:A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. MATERIALS AND METHODS:Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRAD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0300-7

    authors: Destounis S,Hanson S,Morgan R,Murphy P,Somerville P,Seifert P,Andolina V,Arieno A,Skolny M,Logan-Young W

    更新日期:2009-06-01 00:00:00

  • Planning and simulation of microsurgical laser bone ablation.

    abstract:PURPOSE:Laser ablation of hard tissue is not completely understood until now and not modeled for computer-assisted microsurgery. A precise planning and simulation is an essential step toward the usage of microsurgical laser bone ablation in the operating room. METHODS:Planning the volume for laser bone ablation is bas...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0303-4

    authors: Kahrs LA,Burgner J,Klenzner T,Raczkowsky J,Schipper J,Wörn H

    更新日期:2010-03-01 00:00:00

  • Statistical model based analysis of bone mineral density of lumbar spine.

    abstract:OBJECTIVE:For planning surgical interventions at the spine affected by osteoporosis, accurate information about the local bone quality in terms of anchorage strength for implants is very important. Based on previous work on automated bone quality assessment on the proximal femur with a completely automated model-based ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0287-0

    authors: Leber S,Fritscher KD,Schmoelz W,Schubert R

    更新日期:2009-05-01 00:00:00

  • [¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

    abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1260-8

    authors: Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

    更新日期:2016-05-01 00:00:00

  • Formal verification of software-based medical devices considering medical guidelines.

    abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0919-2

    authors: Daw Z,Cleaveland R,Vetter M

    更新日期:2014-01-01 00:00:00

  • Interactive navigation of segmented MR angiograms using simultaneous curved planar and volume visualizations.

    abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0534-4

    authors: van Schooten BW,van Dijk EM,Suinesiaputra A,Reiber JH

    更新日期:2011-09-01 00:00:00

  • Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases.

    abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02218-8

    authors: Geng J,Hu P,Ji Z,Li C,Li L,Shen J,Feng X,Wang W,Yang G,Li J,Zhang H

    更新日期:2020-10-01 00:00:00

  • A computer analysis method for correlating knee X-rays with continuous indicators.

    abstract:PURPOSE:To develop an image analysis method that can automatically find correlations between a set of plain radiographs and continuous clinical or physiological indicators. METHODS:Knee X-rays taken from the Baltimore Longitudinal Study of Aging are used in this study. The computer analysis method is based on the WND-...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0550-z

    authors: Shamir L

    更新日期:2011-09-01 00:00:00

  • Multi-trajectories automatic planner for StereoElectroEncephaloGraphy (SEEG).

    abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1004-1

    authors: De Momi E,Caborni C,Cardinale F,Casaceli G,Castana L,Cossu M,Mai R,Gozzo F,Francione S,Tassi L,Lo Russo G,Antiga L,Ferrigno G

    更新日期:2014-11-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • Fast, robust, and accurate monocular peer-to-peer tracking for surgical navigation.

    abstract:PURPOSE:This work presents a new monocular peer-to-peer tracking concept overcoming the distinction between tracking tools and tracked tools for optical navigation systems. A marker model concept based on marker triplets combined with a fast and robust algorithm for assigning image feature points to the corresponding m...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02111-z

    authors: Strzeletz S,Hazubski S,Moctezuma JL,Hoppe H

    更新日期:2020-03-01 00:00:00

  • Language-based translation and prediction of surgical navigation steps for endoscopic wayfinding assistance in minimally invasive surgery.

    abstract:PURPOSE:In the context of aviation and automotive navigation technology, assistance functions are associated with predictive planning and wayfinding tasks. In endoscopic minimally invasive surgery, however, assistance so far relies primarily on image-based localization and classification. We show that navigation workfl...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02264-2

    authors: Bieck R,Heuermann K,Pirlich M,Neumann J,Neumuth T

    更新日期:2020-12-01 00:00:00

  • Construct and face validity of SINERGIA laparoscopic virtual reality simulator.

    abstract:PURPOSE:Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reali...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0425-8

    authors: Sánchez-Peralta LF,Sánchez-Margallo FM,Moyano-Cuevas JL,Pagador JB,Enciso-Sanz S,Sánchez-González P,Gómez-Aguilera EJ,Usón-Gargallo J

    更新日期:2010-07-01 00:00:00

  • Image-based 3D modeling and validation of radiofrequency interstitial tumor ablation using a tissue-mimicking breast phantom.

    abstract:PURPOSE:Minimally invasive treatment of solid cancers, especially in the breast and liver, remains clinically challenging, despite a variety of treatment modalities, including radiofrequency ablation (RFA), microwave ablation or high-intensity focused ultrasound. Each treatment modality has advantages and disadvantages...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0769-3

    authors: Wang Z,Aarya I,Gueorguieva M,Liu D,Luo H,Manfredi L,Wang L,McLean D,Coleman S,Brown S,Cuschieri A

    更新日期:2012-11-01 00:00:00

  • Real-time inextensible surgical thread simulation.

    abstract:PURPOSE:This paper discusses a real-time simulation method of inextensible surgical thread based on the Cosserat rod theory using position-based dynamics (PBD). The method realizes stable twining and knotting of surgical thread while including inextensibility, bending, twisting and coupling effects. METHODS:The Cosser...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1739-1

    authors: Xu L,Liu Q

    更新日期:2018-07-01 00:00:00

  • Automated muscle segmentation from CT images of the hip and thigh using a hierarchical multi-atlas method.

    abstract:PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1758-y

    authors: Yokota F,Otake Y,Takao M,Ogawa T,Okada T,Sugano N,Sato Y

    更新日期:2018-07-01 00:00:00

  • BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1603-8

    authors: Chen D,Chen W,Huang L,Feng X,Peters T,Gu L

    更新日期:2017-09-01 00:00:00

  • Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy.

    abstract:PURPOSE:Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we pro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02181-4

    authors: Kalia M,Mathur P,Tsang K,Black P,Navab N,Salcudean S

    更新日期:2020-07-01 00:00:00

  • Automated pulmonary nodule CT image characterization in lung cancer screening.

    abstract:PURPOSE:In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malign...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1245-7

    authors: Reeves AP,Xie Y,Jirapatnakul A

    更新日期:2016-01-01 00:00:00

  • Data-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms.

    abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1186-1

    authors: Twinanda AP,Alkan EO,Gangi A,de Mathelin M,Padoy N

    更新日期:2015-06-01 00:00:00

  • Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions.

    abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02029-6

    authors: de Jong TL,Moelker A,Dankelman J,van den Dobbelsteen JJ

    更新日期:2019-12-01 00:00:00

  • Robotic ultrasound-guided facet joint insertion.

    abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1759-x

    authors: Esteban J,Simson W,Requena Witzig S,Rienmüller A,Virga S,Frisch B,Zettinig O,Sakara D,Ryang YM,Navab N,Hennersperger C

    更新日期:2018-06-01 00:00:00

  • Cost-effective, personalized, 3D-printed liver model for preoperative planning before laparoscopic liver hemihepatectomy for colorectal cancer metastases.

    abstract:PURPOSE:Three-dimensional (3D) printing for preoperative planning has been intensively developed in the recent years. However, the implementation of these solutions in hospitals is still difficult due to high costs, extremely expensive industrial-grade printers, and software that is difficult to obtain and learn along ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1527-3

    authors: Witowski JS,Pędziwiatr M,Major P,Budzyński A

    更新日期:2017-12-01 00:00:00

  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Robust GPU-based virtual reality simulation of radio-frequency ablations for various needle geometries and locations.

    abstract:PURPOSE:Radio-frequency ablations play an important role in the therapy of malignant liver lesions. The navigation of a needle to the lesion poses a challenge for both the trainees and intervening physicians. METHODS:This publication presents a new GPU-based, accurate method for the simulation of radio-frequency ablat...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02033-w

    authors: Kath N,Handels H,Mastmeyer A

    更新日期:2019-11-01 00:00:00