Automated muscle segmentation from CT images of the hip and thigh using a hierarchical multi-atlas method.

Abstract:

PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in which each hierarchy includes spatial normalization using simpler pre-segmented structures in order to reduce the inter-patient variability of more complex target structures. RESULTS:The proposed hierarchical method was evaluated with 19 muscles from 20 CT images of the hip and thigh using the manual segmentation by expert orthopedic surgeons as ground truth. The average symmetric surface distance was significantly reduced in the proposed method (1.53 mm) in comparison with the conventional method (2.65 mm). CONCLUSION:We demonstrated that the proposed hierarchical multi-atlas method improved the accuracy of muscle segmentation from CT images, in which large inter-patient variability and insufficient contrast were involved.

authors

Yokota F,Otake Y,Takao M,Ogawa T,Okada T,Sugano N,Sato Y

doi

10.1007/s11548-018-1758-y

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

977-986

issue

7

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-018-1758-y

journal_volume

13

pub_type

杂志文章
  • MITK-US: real-time ultrasound support within MITK.

    abstract:PURPOSE:Intra-procedural acquisition of the patient anatomy is a key technique in the context of computer-assisted interventions (CAI). Ultrasound (US) offers major advantages as an interventional imaging modality because it is real time and low cost and does not expose the patient or physician to harmful radiation. To...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0962-z

    authors: März K,Franz AM,Seitel A,Winterstein A,Bendl R,Zelzer S,Nolden M,Meinzer HP,Maier-Hein L

    更新日期:2014-05-01 00:00:00

  • Data-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms.

    abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1186-1

    authors: Twinanda AP,Alkan EO,Gangi A,de Mathelin M,Padoy N

    更新日期:2015-06-01 00:00:00

  • Multistage segmentation model and SVM-ensemble for precise lung nodule detection.

    abstract:PURPOSE:Lung cancer detection at its initial stages increases the survival chances of patients. Automatic detection of lung nodules facilitates radiologists during the diagnosis. However, there is a challenge of false positives in automated systems which may lead to wrong findings. Precise segmentation facilitates to a...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1715-9

    authors: Naqi SM,Sharif M,Yasmin M

    更新日期:2018-07-01 00:00:00

  • Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1282-2

    authors: Chen X,Cheng J,Gu X,Sun Y,Politis C

    更新日期:2016-04-01 00:00:00

  • MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

    abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0964-x

    authors: Yiallouras C,Mylonas N,Damianou C

    更新日期:2014-07-01 00:00:00

  • Robust and semantic needle detection in 3D ultrasound using orthogonal-plane convolutional neural networks.

    abstract:PURPOSE:During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS:We present a novel appr...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1798-3

    authors: Pourtaherian A,Ghazvinian Zanjani F,Zinger S,Mihajlovic N,Ng GC,Korsten HHM,de With PHN

    更新日期:2018-09-01 00:00:00

  • Incorporating prior shape knowledge via data-driven loss model to improve 3D liver segmentation in deep CNNs.

    abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02085-y

    authors: Mohagheghi S,Foruzan AH

    更新日期:2020-02-01 00:00:00

  • Finger-attachment device for the feedback of gripping and pulling force in a manipulating system for brain tumor resection.

    abstract:PURPOSE:Development and evaluation of an effective attachment device for a bilateral brain tumor resection robotic surgery system based on the sensory performance of the human index finger in order to precisely detect gripping- and pulling-force feedback. METHODS:First, a basic test was conducted to investigate the pe...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1640-3

    authors: Chinbe H,Yoneyama T,Watanabe T,Miyashita K,Nakada M

    更新日期:2018-01-01 00:00:00

  • Robotic ultrasound-guided facet joint insertion.

    abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1759-x

    authors: Esteban J,Simson W,Requena Witzig S,Rienmüller A,Virga S,Frisch B,Zettinig O,Sakara D,Ryang YM,Navab N,Hennersperger C

    更新日期:2018-06-01 00:00:00

  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

    abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1347-2

    authors: Wang X,Habert S,Ma M,Huang CH,Fallavollita P,Navab N

    更新日期:2016-08-01 00:00:00

  • Decision support system for the planning of minimally invasive aortic valve replacement surgery.

    abstract:PURPOSE:Minimally invasive aortic valve replacement (MIAVR) procedures remain more complex and technically challenging compared to conventional full sternotomy surgery. This technique involves a restricted surgical field and a limited workspace, which is, at present, strictly reserved for the most experienced surgeons....

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1725-7

    authors: Li H,Castro M,Haigron P,Verhoye JP,Ruggieri VG

    更新日期:2018-08-01 00:00:00

  • Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1740-8

    authors: Granados A,Vakharia V,Rodionov R,Schweiger M,Vos SB,O'Keeffe AG,Li K,Wu C,Miserocchi A,McEvoy AW,Clarkson MJ,Duncan JS,Sparks R,Ourselin S

    更新日期:2018-06-01 00:00:00

  • Vertebra identification using template matching modelmp and K-means clustering.

    abstract:PURPOSE:Accurate vertebra detection and segmentation are essential steps for automating the diagnosis of spinal disorders. This study is dedicated to vertebra alignment measurement, the first step in a computer-aided diagnosis tool for cervical spine trauma. Automated vertebral segment alignment determination is a chal...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-013-0927-2

    authors: Larhmam MA,Benjelloun M,Mahmoudi S

    更新日期:2014-03-01 00:00:00

  • A computer vision technique for automated assessment of surgical performance using surgeons' console-feed videos.

    abstract:PURPOSE:To develop and validate an automated assessment of surgical performance (AASP) system for objective and computerized assessment of pelvic lymph node dissection (PLND) as an integral part of robot-assisted radical cystectomy (RARC) using console-feed videos recorded during live surgery. METHODS:Video recordings...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1881-9

    authors: Baghdadi A,Hussein AA,Ahmed Y,Cavuoto LA,Guru KA

    更新日期:2019-04-01 00:00:00

  • Differential geometry-based techniques for characterization of boundary roughness of pulmonary nodules in CT images.

    abstract:PURPOSE:Boundary roughness of a pulmonary nodule is an important indication of its malignancy. The irregularity of the shape of a nodule is represented in terms of a few diagnostic characteristics such as spiculation, lobulation, and sphericity. Quantitative characterization of these diagnostic characteristics is essen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1284-0

    authors: Dhara AK,Mukhopadhyay S,Saha P,Garg M,Khandelwal N

    更新日期:2016-03-01 00:00:00

  • Design considerations for a novel MRI compatible manipulator for prostate cryoablation.

    abstract:PURPOSE:Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0558-4

    authors: Abdelaziz S,Esteveny L,Renaud P,Bayle B,Barbé L,De Mathelin M,Gangi A

    更新日期:2011-11-01 00:00:00

  • Language-based translation and prediction of surgical navigation steps for endoscopic wayfinding assistance in minimally invasive surgery.

    abstract:PURPOSE:In the context of aviation and automotive navigation technology, assistance functions are associated with predictive planning and wayfinding tasks. In endoscopic minimally invasive surgery, however, assistance so far relies primarily on image-based localization and classification. We show that navigation workfl...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02264-2

    authors: Bieck R,Heuermann K,Pirlich M,Neumann J,Neumuth T

    更新日期:2020-12-01 00:00:00

  • Hybrid simulation using mixed reality for interventional ultrasound imaging training.

    abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1113-x

    authors: Freschi C,Parrini S,Dinelli N,Ferrari M,Ferrari V

    更新日期:2015-07-01 00:00:00

  • A statistical shape model of the human second cervical vertebra.

    abstract:PURPOSE:Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the sh...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1121-x

    authors: Clogenson M,Duff JM,Luethi M,Levivier M,Meuli R,Baur C,Henein S

    更新日期:2015-07-01 00:00:00

  • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0957-9

    authors: Amiri S,Wilson DR,Masri BA,Anglin C

    更新日期:2014-07-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

    abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1538-0

    authors: Li M,Castillo SJ,Castillo R,Castillo E,Guerrero T,Xiao L,Zheng X

    更新日期:2017-09-01 00:00:00

  • Interactive navigation of segmented MR angiograms using simultaneous curved planar and volume visualizations.

    abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0534-4

    authors: van Schooten BW,van Dijk EM,Suinesiaputra A,Reiber JH

    更新日期:2011-09-01 00:00:00

  • Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases.

    abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02218-8

    authors: Geng J,Hu P,Ji Z,Li C,Li L,Shen J,Feng X,Wang W,Yang G,Li J,Zhang H

    更新日期:2020-10-01 00:00:00

  • Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1228-8

    authors: Wagner ME,Gellrich NC,Friese KI,Becker M,Wolter FE,Lichtenstein JT,Stoetzer M,Rana M,Essig H

    更新日期:2016-01-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions.

    abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02226-8

    authors: Li X,Young AS,Raman SS,Lu DS,Lee YH,Tsao TC,Wu HH

    更新日期:2020-10-01 00:00:00

  • A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia.

    abstract:PURPOSE:Automatic segmentation of anatomical structures and lesions from medical ultrasound images is a formidable challenge in medical imaging due to image noise, blur and artifacts. In this paper we present a segmentation technique with features highly suited to use in noisy 3D ultrasound volumes and demonstrate its ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1239-5

    authors: Hareendranathan AR,Mabee M,Punithakumar K,Noga M,Jaremko JL

    更新日期:2016-01-01 00:00:00

  • Analytical derivation of elasticity in breast phantoms for deformation tracking.

    abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1803-x

    authors: Groenhuis V,Visentin F,Siepel FJ,Maris BM,Dall'alba D,Fiorini P,Stramigioli S

    更新日期:2018-10-01 00:00:00