Abstract:
PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpose and tested. METHODS:A dual view visualization scheme was developed using the vessel pathline for both camera position and rotation in 3D, greatly reducing the degrees of freedom (DOF) required for navigation. Pathline-based navigation facilitates coupling of the CPR and DVR views, as local position and orientation can be matched precisely. The new technique was compared to traditional techniques in a user study. Layperson users were required to perform a visual search task that involves checking for (minor) errors in segmentations of MRA data from a software phantom. The task requires the user to examine both views. RESULTS:Pathline-based navigation and coupling of CPR and DVR provide user speed performance improvements in a vessel inspection task. Interactive MRA visualization with this method, where rotational degrees of freedom were reduced, had no negative effect. CONCLUSIONS:The DOF reduction achieved by the new navigation technique is beneficial to user performance. The technique is promising and merits comprehensive evaluation in a realistic clinical setting.
journal_name
Int J Comput Assist Radiol Surgauthors
van Schooten BW,van Dijk EM,Suinesiaputra A,Reiber JHdoi
10.1007/s11548-010-0534-4subject
Has Abstractpub_date
2011-09-01 00:00:00pages
591-9issue
5eissn
1861-6410issn
1861-6429journal_volume
6pub_type
杂志文章abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0957-9
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1655-9
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1556-y
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1282-2
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:To support preoperative planning of bone drilling for Microendoscopic Discectomy, we present a set of interactive bone-drilling methods using a general 2D pointing device. METHODS:Unlike the existing methods, our framework has the following features: (1) the user can directly cut away arbitrary 3D regions on t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0413-z
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0976-1
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1603-8
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and ste...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1777-8
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:B-mode ultrasound (B-US) and strain elastography ultrasound (SE-US) images have a potential to distinguish thyroid tumor with different lymph node (LN) status. The purpose of our study is to investigate whether the application of multi-modality images including B-US and SE-US can improve the discriminability of...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1796-5
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01915-3
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:Cardiac strain calculated from tagged magnetic resonance (MR) images provides clinicians information about abnormalities of heart-wall motion in patients. It is important to develop an accurate method to determine the cardiac strain efficiently. An adaptive windowed harmonic phase (AWHARP) method is proposed fo...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0689-2
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02160-9
更新日期:2020-05-01 00:00:00
abstract:PURPOSE:Automated segmentation of anatomical structures in medical image analysis is a prerequisite for autonomous diagnosis as well as various computer- and robot-aided interventions. Recent methods based on deep convolutional neural networks (CNN) have outperformed former heuristic methods. However, those methods wer...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-01910-0
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1186-1
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02029-6
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:The main purpose of this work is to develop, apply, and evaluate an efficient approach for breast density estimation in magnetic resonance imaging data, which contain strong artifacts including intensity inhomogeneities. METHODS:We present a pipeline for breast density estimation, which consists of intensity i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01928-y
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:This work presents a new monocular peer-to-peer tracking concept overcoming the distinction between tracking tools and tracked tools for optical navigation systems. A marker model concept based on marker triplets combined with a fast and robust algorithm for assigning image feature points to the corresponding m...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02111-z
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0997-9
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1590-9
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1194-1
更新日期:2015-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-01908-8
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02085-y
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. METHOD...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1078-9
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficien...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1380-9
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Segmenting the cardiac ventricles in magnetic resonance (MR) images is required for cardiac function assessment. Numerous segmentation methods have been developed and applied to MR ventriculography. Quantitative validation of these segmentation methods with ground truth is needed prior to clinical use, but requ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0532-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Accurate vertebra detection and segmentation are essential steps for automating the diagnosis of spinal disorders. This study is dedicated to vertebra alignment measurement, the first step in a computer-aided diagnosis tool for cervical spine trauma. Automated vertebral segment alignment determination is a chal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-013-0927-2
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:Ultrasound (US) imaging offers advantages over other imaging modalities and has become the most widespread modality for many diagnostic and interventional procedures. However, traditional 2D US requires a long training period, especially to learn how to manipulate the probe. A hybrid interactive system based on...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1113-x
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1075-z
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01935-z
更新日期:2019-08-01 00:00:00
abstract:PURPOSE:When we register diffusion tensor tractography (DTT) to anatomical images such as fast imaging employing steady-state acquisition (FIESTA), we register the B0 image to FIESTA. Precise registration of the DTT B0 image to FIESTA is possible with non-rigid registration compared to rigid registration, although the ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0934-3
更新日期:2013-08-20 00:00:00