Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution.

Abstract:

PURPOSE:Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate "hand-eye" calibration to determine the geometrical relationship between the surgical camera and tracking markers. METHODS:Using a tracked ball-tip stylus, we formulated hand-eye calibration as a Perspective-n-Point problem, which can be solved efficiently and accurately using as few as 15 measurements. RESULTS:The proposed hand-eye calibration algorithm was applied to three types of camera and validated against five other widely used methods. Using projection error as the accuracy metric, our proposed algorithm compared favourably with existing methods. CONCLUSION:We present a fully automated hand-eye calibration technique, based on Procrustean point-to-line registration, which provides superior results for calibrating surgical cameras when compared to existing methods.

authors

Morgan I,Jayarathne U,Rankin A,Peters TM,Chen ECS

doi

10.1007/s11548-017-1590-9

subject

Has Abstract

pub_date

2017-07-01 00:00:00

pages

1141-1149

issue

7

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-017-1590-9

journal_volume

12

pub_type

杂志文章
  • Edge map analysis in chest X-rays for automatic pulmonary abnormality screening.

    abstract:PURPOSE:Our particular motivator is the need for screening HIV+ populations in resource-constrained regions for the evidence of tuberculosis, using posteroanterior chest radiographs (CXRs). METHOD:The proposed method is motivated by the observation that abnormal CXRs tend to exhibit corrupted and/or deformed thoracic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1359-6

    authors: Santosh KC,Vajda S,Antani S,Thoma GR

    更新日期:2016-09-01 00:00:00

  • Breast tumor classification using different features of quantitative ultrasound parametric images.

    abstract:RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01908-8

    authors: Hsu SM,Kuo WH,Kuo FC,Liao YY

    更新日期:2019-04-01 00:00:00

  • Comparing calibration approaches for 3D ultrasound probes.

    abstract:OBJECTIVE:By adding a tracking sensor to a 3D ultrasound (US) probe and thus locating the probe in space, new applications within the fields of image guided surgery and radiation therapy are possible. To locate the US volume in space, a calibration is necessary to determine the mathematical transformation for mapping p...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0258-x

    authors: Bergmeir C,Seitel M,Frank C,De Simone R,Meinzer HP,Wolf I

    更新日期:2009-03-01 00:00:00

  • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0957-9

    authors: Amiri S,Wilson DR,Masri BA,Anglin C

    更新日期:2014-07-01 00:00:00

  • Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis.

    abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02087-w

    authors: Atehortúa A,Garreau M,Simon A,Donal E,Lederlin M,Romero E

    更新日期:2020-02-01 00:00:00

  • Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography.

    abstract:PURPOSE:A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. MATERIALS AND METHODS:Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRAD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0300-7

    authors: Destounis S,Hanson S,Morgan R,Murphy P,Somerville P,Seifert P,Andolina V,Arieno A,Skolny M,Logan-Young W

    更新日期:2009-06-01 00:00:00

  • A practical marker-less image registration method for augmented reality oral and maxillofacial surgery.

    abstract:BACKGROUND:Image registration lies in the core of augmented reality (AR), which aligns the virtual scene with the reality. In AR surgical navigation, the performance of image registration is vital to the surgical outcome. METHODS:This paper presents a practical marker-less image registration method for AR-guided oral ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01921-5

    authors: Wang J,Shen Y,Yang S

    更新日期:2019-05-01 00:00:00

  • A projected landmark method for reduction of registration error in image-guided surgery systems.

    abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1075-z

    authors: Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SM

    更新日期:2015-05-01 00:00:00

  • A gesture-controlled projection display for CT-guided interventions.

    abstract:PURPOSE:The interaction with interventional imaging systems within a sterile environment is a challenging task for physicians. Direct physician-machine interaction during an intervention is rather limited because of sterility and workspace restrictions. METHODS:We present a gesture-controlled projection display that e...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1215-0

    authors: Mewes A,Saalfeld P,Riabikin O,Skalej M,Hansen C

    更新日期:2016-01-01 00:00:00

  • Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

    abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1347-2

    authors: Wang X,Habert S,Ma M,Huang CH,Fallavollita P,Navab N

    更新日期:2016-08-01 00:00:00

  • Data-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms.

    abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1186-1

    authors: Twinanda AP,Alkan EO,Gangi A,de Mathelin M,Padoy N

    更新日期:2015-06-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Projection-based visual guidance for robot-aided RF needle insertion.

    abstract:PURPOSE:The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0897-4

    authors: Wen R,Chui CK,Ong SH,Lim KB,Chang SK

    更新日期:2013-11-01 00:00:00

  • A framework for correcting brain retraction based on an eXtended Finite Element Method using a laser range scanner.

    abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0958-8

    authors: Li P,Wang W,Song Z,An Y,Zhang C

    更新日期:2014-07-01 00:00:00

  • Pre-clinical evaluation of an image-guided in-situ Raman spectroscopy navigation system for targeted prostate cancer interventions.

    abstract:PURPOSE:Transrectal ultrasound (TRUS) image guidance is the standard of care for diagnostic and therapeutic interventions in prostate cancer (PCa) patients, but can lead to high false-negative rates, compromising downstream effectiveness of therapeutic choices. A promising approach to improve in-situ detection of PCa l...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02136-9

    authors: Shams R,Picot F,Grajales D,Sheehy G,Dallaire F,Birlea M,Saad F,Trudel D,Menard C,Leblond F,Kadoury S

    更新日期:2020-05-01 00:00:00

  • Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions.

    abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02226-8

    authors: Li X,Young AS,Raman SS,Lu DS,Lee YH,Tsao TC,Wu HH

    更新日期:2020-10-01 00:00:00

  • Design considerations for a novel MRI compatible manipulator for prostate cryoablation.

    abstract:PURPOSE:Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0558-4

    authors: Abdelaziz S,Esteveny L,Renaud P,Bayle B,Barbé L,De Mathelin M,Gangi A

    更新日期:2011-11-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    abstract:PURPOSE:Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermog...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1683-5

    authors: Rathmann P,Chalopin C,Halama D,Giri P,Meixensberger J,Lindner D

    更新日期:2018-03-01 00:00:00

  • Robust motion tracking in liver from 2D ultrasound images using supporters.

    abstract:PURPOSE:Effectiveness of image-guided radiation therapy with precise dose delivery depends highly on accurate target localization, which may involve motion during treatment due to, e.g., breathing and drift. Therefore, it is important to track the motion and adjust the radiation delivery accordingly. Tracking generally...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1559-8

    authors: Ozkan E,Tanner C,Kastelic M,Mattausch O,Makhinya M,Goksel O

    更新日期:2017-06-01 00:00:00

  • Segmentation of the placenta and its vascular tree in Doppler ultrasound for fetal surgery planning.

    abstract:PURPOSE:Twin-to-twin transfusion syndrome (TTTS) is a serious condition that occurs in about 10-15% of monochorionic twin pregnancies. In most instances, the blood flow is unevenly distributed throughout the placenta anastomoses leading to the death of both fetuses if no surgical procedure is performed. Fetoscopic lase...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02256-2

    authors: Perera-Bel E,Ceresa M,Torrents-Barrena J,Masoller N,Valenzuela-Alcaraz B,Gratacós E,Eixarch E,González Ballester MA

    更新日期:2020-11-01 00:00:00

  • Unravelling the effect of data augmentation transformations in polyp segmentation.

    abstract:PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of differen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02262-4

    authors: Sánchez-Peralta LF,Picón A,Sánchez-Margallo FM,Pagador JB

    更新日期:2020-12-01 00:00:00

  • Analyzing shoulder translation with navigation technology.

    abstract:PURPOSE:Asymmetric stress imposed on the shoulder can lead to anterior shoulder instability in young athletes who perform repetitive overhead motions. A common treatment, surgical anterior capsule tightening, assumes that the instability is caused by abnormal anterior laxity. This study investigated the possibility tha...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0782-6

    authors: Zakani S,Venne G,Smith EJ,Bicknell R,Ellis RE

    更新日期:2012-11-01 00:00:00

  • MITK-US: real-time ultrasound support within MITK.

    abstract:PURPOSE:Intra-procedural acquisition of the patient anatomy is a key technique in the context of computer-assisted interventions (CAI). Ultrasound (US) offers major advantages as an interventional imaging modality because it is real time and low cost and does not expose the patient or physician to harmful radiation. To...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0962-z

    authors: März K,Franz AM,Seitel A,Winterstein A,Bendl R,Zelzer S,Nolden M,Meinzer HP,Maier-Hein L

    更新日期:2014-05-01 00:00:00

  • Within-brain classification for brain tumor segmentation.

    abstract:PURPOSE:In this paper, we investigate a framework for interactive brain tumor segmentation which, at its core, treats the problem of interactive brain tumor segmentation as a machine learning problem. METHODS:This method has an advantage over typical machine learning methods for this task where generalization is made ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1311-1

    authors: Havaei M,Larochelle H,Poulin P,Jodoin PM

    更新日期:2016-05-01 00:00:00

  • Learned optical flow for intra-operative tracking of the retinal fundus.

    abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02160-9

    authors: Ravasio CS,Pissas T,Bloch E,Flores B,Jalali S,Stoyanov D,Cardoso JM,Da Cruz L,Bergeles C

    更新日期:2020-05-01 00:00:00

  • Interactive bone drilling using a 2D pointing device to support Microendoscopic Discectomy planning.

    abstract:PURPOSE:To support preoperative planning of bone drilling for Microendoscopic Discectomy, we present a set of interactive bone-drilling methods using a general 2D pointing device. METHODS:Unlike the existing methods, our framework has the following features: (1) the user can directly cut away arbitrary 3D regions on t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0413-z

    authors: Imanishi K,Nakao M,Kioka M,Mori M,Yoshida M,Takahashi T,Minato K

    更新日期:2010-09-01 00:00:00

  • Computer-aided cephalometric landmark annotation for CBCT data.

    abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1453-9

    authors: Codari M,Caffini M,Tartaglia GM,Sforza C,Baselli G

    更新日期:2017-01-01 00:00:00

  • Cost-effective, personalized, 3D-printed liver model for preoperative planning before laparoscopic liver hemihepatectomy for colorectal cancer metastases.

    abstract:PURPOSE:Three-dimensional (3D) printing for preoperative planning has been intensively developed in the recent years. However, the implementation of these solutions in hospitals is still difficult due to high costs, extremely expensive industrial-grade printers, and software that is difficult to obtain and learn along ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1527-3

    authors: Witowski JS,Pędziwiatr M,Major P,Budzyński A

    更新日期:2017-12-01 00:00:00

  • Orbital volume analysis: validation of a semi-automatic software segmentation method.

    abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1254-6

    authors: Jansen J,Schreurs R,Dubois L,Maal TJ,Gooris PJ,Becking AG

    更新日期:2016-01-01 00:00:00