PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of different transformations on polyp segmentation using deep learning. METHODS:A set of transformations and ranges have been selected, considering image-based (width and height shift, rotation, shear, zooming, horizontal and vertical flip and elastic deformation), pixel-based (changes in brightness and contrast) and application-based (specular lights and blurry frames) transformations. A model has been trained under the same conditions without data augmentation transformations (baseline) and for each of the transformation and ranges, using CVC-EndoSceneStill and Kvasir-SEG, independently. Statistical analysis is performed to compare the baseline performance against results of each range of each transformation on the same test set for each dataset. RESULTS:This basic method identifies the most adequate transformations for each dataset. For CVC-EndoSceneStill, changes in brightness and contrast significantly improve the model performance. On the contrary, Kvasir-SEG benefits to a greater extent from the image-based transformations, especially rotation and shear. Augmentation with synthetic specular lights also improves the performance. CONCLUSION:Despite being infrequently used, pixel-based transformations show a great potential to improve polyp segmentation in CVC-EndoSceneStill. On the other hand, image-based transformations are more suitable for Kvasir-SEG. Problem-based transformations behave similarly in both datasets. Polyp area, brightness and contrast of the dataset have an influence on these differences.
journal_name
Int J Comput Assist Radiol Surgauthors
Sánchez-Peralta LF,Picón A,Sánchez-Margallo FM,Pagador JBdoi
10.1007/s11548-020-02262-4subject
Has Abstractpub_date
2020-12-01 00:00:00pages
1975-1988issue
12eissn
1861-6410issn
1861-6429pii
10.1007/s11548-020-02262-4journal_volume
15pub_type
杂志文章abstract:PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1758-y
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Despite great advances in medical image segmentation, the accurate and automatic segmentation of endoscopic scenes remains a challenging problem. Two important aspects have to be considered in segmenting an endoscopic scene: (1) noise and clutter due to light reflection and smoke from cutting tissue, and (2) st...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1331-x
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:To support preoperative planning of bone drilling for Microendoscopic Discectomy, we present a set of interactive bone-drilling methods using a general 2D pointing device. METHODS:Unlike the existing methods, our framework has the following features: (1) the user can directly cut away arbitrary 3D regions on t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0413-z
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1453-9
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02226-8
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:Suspension laryngoscopy has been employed for laryngeal diseases such as treatment for a polyp, cystoma, or granuloma. After securing a straight path with a laryngoscope, the surgeon inserts rigid instruments and examines the target lesion by using a microscope. However, many patients suffer from secondary comp...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0944-1
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the sh...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1121-x
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:The favored treatment for many hip fractures is a sliding hip screw, and its usage is expected to increase in the future. Failures can be reduced, and complications detected earlier by semi-automated CT image analysis. The most frequent failure is due to the screw cut-out from the femoral head. METHODS:An imag...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0498-4
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1421-4
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS:We present a novel appr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1798-3
更新日期:2018-09-01 00:00:00
abstract:PURPOSE:Analyzing surgical activities has received a growing interest in recent years. Several methods have been proposed to identify surgical activities and surgical phases from data acquired in operating rooms. These context-aware systems have multiple applications including: supporting the surgical team during the i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1195-0
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01915-3
更新日期:2019-05-01 00:00:00
abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0964-x
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:As the spectrum of X-ray procedures has increased both for diagnostic and for interventional cases, more attention is paid to X-ray dose management. While the medical benefit to the patient outweighs the risk of radiation injuries in almost all cases, reproducible studies on organ dose values help to plan preve...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02298-6
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:Segmenting the cardiac ventricles in magnetic resonance (MR) images is required for cardiac function assessment. Numerous segmentation methods have been developed and applied to MR ventriculography. Quantitative validation of these segmentation methods with ground truth is needed prior to clinical use, but requ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0532-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0831-9
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:Glioblastoma multiforme treatment is a challenging task in clinical oncology. Convection- enhanced delivery (CED) is showing encouraging but still suboptimal results due to drug leakages. Numerical models can predict drug distribution within the brain, but require retrieving brain physical properties, such as t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-01911-z
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1538-0
更新日期:2017-09-01 00:00:00
abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0958-8
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02160-9
更新日期:2020-05-01 00:00:00
abstract:PURPOSE:The reconstruction of large continuity defects of the mandible is a challenging task, especially when the shape of the missing part is not known prior to operation. Today, the surgical planning is based mainly on visual judgment and the individual skills and experience of the surgeons. The objective of the curr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1451-y
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0366-2
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS) image guidance is the standard of care for diagnostic and therapeutic interventions in prostate cancer (PCa) patients, but can lead to high false-negative rates, compromising downstream effectiveness of therapeutic choices. A promising approach to improve in-situ detection of PCa l...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02136-9
更新日期:2020-05-01 00:00:00
abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0919-2
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:Laparoscopic ultrasound (LUS) enhances the safety of laparoscopic liver resection by enabling real-time imaging of internal structures such as vessels. However, LUS probes can be difficult to use, and many tumours are iso-echoic and hence are not visible. Registration of LUS to a pre-operative CT or MR scan has...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1799-2
更新日期:2018-08-01 00:00:00
abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0690-9
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0976-1
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:Ultrasound acquisitions are typically affected by deformations due to the pressure applied onto the contact surface. While a certain amount of pressure is necessary to ensure good acoustic coupling and visibility of the anatomy under examination, the caused deformations hinder accurate localization and geometri...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1716-8
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1803-x
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1759-x
更新日期:2018-06-01 00:00:00