Abstract:
PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visible surfaces to create projected landmarks over a region of interest. Surface information thus becomes available in the form of point clouds of surface point coordinates with submillimeter resolution. The reconstructed 3D point cloud is registered using iterative closest point (ICP) approximation to a 3D point cloud extracted from preoperative CT images of the same region of interest. The projected landmark surface registration method was compared with two other methods using a facial surface phantom: (a) landmark registration using anatomical features, and (b) surface matching based on an additional 40 surface points. RESULTS:The mean error for the projected landmark surface registration method was 0.64 mm, which was 47.4 and 35.3 % lower relative to mean errors of the anatomical landmark registration and the surface-matching methods, respectively. After applying the proposed method, using target registration error as a gold standard, the resulting mean error was 1.1 mm or a reduction of 61.2 % compared to the anatomical landmark registration. CONCLUSION:Optical checkerboard pattern projection onto visible surfaces was used to acquire surface point clouds for image-guided surgery registration. A projected landmark method eliminated the effects of unwanted and overlapping points by acquiring the desired points at specific locations. The results were more accurate than conventional landmark or surface registration.
journal_name
Int J Comput Assist Radiol Surgauthors
Serej ND,Ahmadian A,Mohagheghi S,Sadrehosseini SMdoi
10.1007/s11548-014-1075-zsubject
Has Abstractpub_date
2015-05-01 00:00:00pages
541-54issue
5eissn
1861-6410issn
1861-6429journal_volume
10pub_type
杂志文章abstract:PURPOSE:The objective of medical content-based image retrieval (CBIR) is to assist clinicians in decision making by retrieving the most similar cases to a given query image from a large database. Herein, a new method for content-based image retrieval of cone beam CT (CBCT) scans is presented. METHODS:The introduced fr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01946-w
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0831-9
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0957-9
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Brain tumor patients are usually accompanied by impairments in cognitive functions, and these dysfunctions arise from the altered diffusion tensor of water molecules and disrupted neuronal conduction in white matter. Diffusion tensor imaging (DTI) is a powerful noninvasive imaging technique that can reflect dif...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1330-y
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:To develop and validate an automated assessment of surgical performance (AASP) system for objective and computerized assessment of pelvic lymph node dissection (PLND) as an integral part of robot-assisted radical cystectomy (RARC) using console-feed videos recorded during live surgery. METHODS:Video recordings...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1881-9
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Asymmetric stress imposed on the shoulder can lead to anterior shoulder instability in young athletes who perform repetitive overhead motions. A common treatment, surgical anterior capsule tightening, assumes that the instability is caused by abnormal anterior laxity. This study investigated the possibility tha...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0782-6
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:This paper presents new quantitative data on a signal-to-noise ratio (SNR) study, distortion study, and targeting accuracy phantom study for our patient-mounted robot (called Arthrobot). Arthrobot was developed as an MRI-guided needle placement device for diagnostic and interventional procedures such as arthrog...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1839-y
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:This work presents a new monocular peer-to-peer tracking concept overcoming the distinction between tracking tools and tracked tools for optical navigation systems. A marker model concept based on marker triplets combined with a fast and robust algorithm for assigning image feature points to the corresponding m...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02111-z
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1409-0
更新日期:2016-06-01 00:00:00
abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 已发布勘误
doi:10.1007/s11548-020-02119-w
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and ste...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1777-8
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1752-4
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Organ motion due to patient breathing introduces a technical challenge for dosimetry and lung tumor treatment by hadron therapy. Accurate dose distribution estimation requires patient-specific information on tumor position, size, and shape as well as information regarding the material density and stopping power...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0935-2
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biop...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1603-8
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0897-4
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0548-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:This paper discusses a real-time simulation method of inextensible surgical thread based on the Cosserat rod theory using position-based dynamics (PBD). The method realizes stable twining and knotting of surgical thread while including inextensibility, bending, twisting and coupling effects. METHODS:The Cosser...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1739-1
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Lung cancer detection at its initial stages increases the survival chances of patients. Automatic detection of lung nodules facilitates radiologists during the diagnosis. However, there is a challenge of false positives in automated systems which may lead to wrong findings. Precise segmentation facilitates to a...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1715-9
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0690-9
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1254-6
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1453-9
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:When we register diffusion tensor tractography (DTT) to anatomical images such as fast imaging employing steady-state acquisition (FIESTA), we register the B0 image to FIESTA. Precise registration of the DTT B0 image to FIESTA is possible with non-rigid registration compared to rigid registration, although the ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0934-3
更新日期:2013-08-20 00:00:00
abstract:PURPOSE:Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we pro...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02181-4
更新日期:2020-07-01 00:00:00
abstract:BACKGROUNDS:Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). An alternative...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0515-7
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. METHODS:We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1329-4
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:Patient-specific quantitative assessments of muscle mass and biomechanical musculoskeletal simulations require segmentation of the muscles from medical images. The objective of this work is to automate muscle segmentation from CT data of the hip and thigh. METHOD:We propose a hierarchical multi-atlas method in...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1758-y
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1004-1
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guid...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02226-8
更新日期:2020-10-01 00:00:00
abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0964-x
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Context-aware systems for the operating room (OR) provide the possibility to significantly improve surgical workflow through various applications such as efficient OR scheduling, context-sensitive user interfaces, and automatic transcription of medical procedures. Being an essential element of such a system, su...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1186-1
更新日期:2015-06-01 00:00:00