Development of a shoulder-mounted robot for MRI-guided needle placement: phantom study.

Abstract:

PURPOSE:This paper presents new quantitative data on a signal-to-noise ratio (SNR) study, distortion study, and targeting accuracy phantom study for our patient-mounted robot (called Arthrobot). Arthrobot was developed as an MRI-guided needle placement device for diagnostic and interventional procedures such as arthrography. METHODS:We present the robot design and inverse kinematics. Quantitative assessment results for SNR and distortion study are also reported. A respiratory motion study was conducted to evaluate the shoulder mounting method. A phantom study was conducted to investigate end-to-end targeting accuracy. Combined error considering targeting accuracy, respiratory motion, and structure deformation is also reported. RESULTS:The SNR study showed that the SNR changes only 2% when the unpowered robot was placed on top of a standard water phantom. The distortion study showed that the maximum distortion from the ground truth was 2.57%. The average error associated with respiratory motion was 1.32 mm with standard deviation of 1.38 mm. Results of gel phantom targeting studies indicate average needle placement error of 1.64 mm, with a standard deviation of 0.90 mm. CONCLUSIONS:Noise and distortion of the MR images were not significant, and image quality in the presence of the robot was satisfactory for MRI-guided targeting. Combined average total error, adding mounting stability errors and structure deformation errors to targeting error, is estimated to be 3.4 mm with a standard deviation of 1.65 mm. In clinical practice, needle placement accuracy under 5 mm is considered sufficient for successful joint injection during shoulder arthrography. Therefore, for the intended clinical procedure, these results indicate that Arthrobot has sufficient positioning accuracy.

authors

Monfaredi R,Iordachita I,Wilson E,Sze R,Sharma K,Krieger A,Fricke S,Cleary K

doi

10.1007/s11548-018-1839-y

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

1829-1841

issue

11

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-018-1839-y

journal_volume

13

pub_type

杂志文章
  • A fully 3D work context for oral implant planning and simulation.

    abstract:PURPOSE:Most software systems for oral implantology are based on a two-dimensional multi-view approach, often accompanied with a surface rendered model. Usually they are affected by common errors like anisotropy of the volume and distortion on measurements. A more integrated and realistic 3D approach for implant surger...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0394-y

    authors: Chiarelli T,Lamma E,Sansoni T

    更新日期:2010-01-01 00:00:00

  • Knee arthroscopic navigation using virtual-vision rendering and self-positioning technology.

    abstract:PURPOSE:Knee arthroscopy suffers from a lack of depth information and easy occlusion of the visual field. To solve these limitations, we propose an arthroscopic navigation system based on self-positioning technology, with the guidance of virtual-vision views. This system can work without any external tracking devices o...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02099-6

    authors: Ma C,Cui X,Chen F,Ma L,Xin S,Liao H

    更新日期:2020-03-01 00:00:00

  • Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study.

    abstract:PURPOSE:To perform bronchoscopy safely and smoothly, it is very important to develop a bronchoscopic guidance system. Transbronchial lung biopsy (TBLB) with a bronchoscopic guidance system especially should permit safe image-guided procedures. Recently, electromagnetic tracking (EMT) is utilized to track the tip of the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0626-9

    authors: Deguchi D,Feuerstein M,Kitasaka T,Suenaga Y,Ide I,Murase H,Imaizumi K,Hasegawa Y,Mori K

    更新日期:2012-05-01 00:00:00

  • Language-based translation and prediction of surgical navigation steps for endoscopic wayfinding assistance in minimally invasive surgery.

    abstract:PURPOSE:In the context of aviation and automotive navigation technology, assistance functions are associated with predictive planning and wayfinding tasks. In endoscopic minimally invasive surgery, however, assistance so far relies primarily on image-based localization and classification. We show that navigation workfl...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02264-2

    authors: Bieck R,Heuermann K,Pirlich M,Neumann J,Neumuth T

    更新日期:2020-12-01 00:00:00

  • Gain determination of feedback force for an ultrasound scanning robot using genetic algorithm.

    abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01915-3

    authors: Kim YJ,Park CK,Kim KG

    更新日期:2019-05-01 00:00:00

  • Correction to: Automated measurement of bone scan index from a whole-body bone scintigram.

    abstract::The article Automated measurement of bone scan index from a whole-body bone scintigram. ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 已发布勘误

    doi:10.1007/s11548-020-02119-w

    authors: Shimizu A,Wakabayashi H,Kanamori T,Saito A,Nishikawa K,Daisaki H,Higashiyama S,Kawabe J

    更新日期:2020-03-01 00:00:00

  • Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

    abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1538-0

    authors: Li M,Castillo SJ,Castillo R,Castillo E,Guerrero T,Xiao L,Zheng X

    更新日期:2017-09-01 00:00:00

  • Orbital volume analysis: validation of a semi-automatic software segmentation method.

    abstract:PURPOSE:The purpose of this study was to validate a quick, accurate and reproducible (semi-) automatic software segmentation method to measure orbital volume in the unaffected bony orbit. Precise volume measurement of the orbital cavity is a useful addition to pre-operative planning and intraoperative navigation in orb...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1254-6

    authors: Jansen J,Schreurs R,Dubois L,Maal TJ,Gooris PJ,Becking AG

    更新日期:2016-01-01 00:00:00

  • Interactive determination of robust safety margins for oncologic liver surgery.

    abstract:OBJECTIVE:Complex oncologic interventions in the liver require an extensive and careful preoperative analysis. Particularly the achievement of an optimal safety margin around tumors remains a difficult task for surgeons. METHODS:We present new methods for evaluating different safety margins and their effect on the ass...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0359-1

    authors: Hansen C,Zidowitz S,Hindennach M,Schenk A,Hahn H,Peitgen HO

    更新日期:2009-09-01 00:00:00

  • Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

    abstract:PURPOSE:Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1556-y

    authors: Hacihaliloglu I

    更新日期:2017-06-01 00:00:00

  • Path generator control system and virtual compliance calculator for maxillofacial massage robots.

    abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0383-1

    authors: Ishii H,Koga H,Obokawa Y,Solis J,Takanishi A,Katsumata A

    更新日期:2010-01-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Vertebra identification using template matching modelmp and K-means clustering.

    abstract:PURPOSE:Accurate vertebra detection and segmentation are essential steps for automating the diagnosis of spinal disorders. This study is dedicated to vertebra alignment measurement, the first step in a computer-aided diagnosis tool for cervical spine trauma. Automated vertebral segment alignment determination is a chal...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-013-0927-2

    authors: Larhmam MA,Benjelloun M,Mahmoudi S

    更新日期:2014-03-01 00:00:00

  • Unravelling the effect of data augmentation transformations in polyp segmentation.

    abstract:PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of differen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02262-4

    authors: Sánchez-Peralta LF,Picón A,Sánchez-Margallo FM,Pagador JB

    更新日期:2020-12-01 00:00:00

  • Four-dimensional fully convolutional residual network-based liver segmentation in Gd-EOB-DTPA-enhanced MRI.

    abstract:PURPOSE:Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) tends to show higher diagnostic accuracy than other modalities. There is a demand for computer-assisted detection (CAD) software for Gd-EOB-DTPA-enhanced MRI. Segmentation with high accuracy is im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01935-z

    authors: Takenaga T,Hanaoka S,Nomura Y,Nemoto M,Murata M,Nakao T,Miki S,Yoshikawa T,Hayashi N,Abe O

    更新日期:2019-08-01 00:00:00

  • Automated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI.

    abstract:PURPOSE:We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). METHODS:The method is based on superpixel technique and classification of each supe...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1483-3

    authors: Soltaninejad M,Yang G,Lambrou T,Allinson N,Jones TL,Barrick TR,Howe FA,Ye X

    更新日期:2017-02-01 00:00:00

  • Regional infarction identification from cardiac CT images: a computer-aided biomechanical approach.

    abstract:PURPOSE:Regional infarction identification is important for heart disease diagnosis and management, and myocardial deformation has been shown to be effective for this purpose. Although tagged and strain-encoded MR images can provide such measurements, they are uncommon in clinical routine. On the contrary, cardiac CT i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-016-1404-5

    authors: Wong KC,Tee M,Chen M,Bluemke DA,Summers RM,Yao J

    更新日期:2016-09-01 00:00:00

  • Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1228-8

    authors: Wagner ME,Gellrich NC,Friese KI,Becker M,Wolter FE,Lichtenstein JT,Stoetzer M,Rana M,Essig H

    更新日期:2016-01-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • XDose: toward online cross-validation of experimental and computational X-ray dose estimation.

    abstract:PURPOSE:As the spectrum of X-ray procedures has increased both for diagnostic and for interventional cases, more attention is paid to X-ray dose management. While the medical benefit to the patient outweighs the risk of radiation injuries in almost all cases, reproducible studies on organ dose values help to plan preve...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02298-6

    authors: Roser P,Birkhold A,Preuhs A,Ochs P,Stepina E,Strobel N,Kowarschik M,Fahrig R,Maier A

    更新日期:2021-01-01 00:00:00

  • System events: readily accessible features for surgical phase detection.

    abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1409-0

    authors: Malpani A,Lea C,Chen CC,Hager GD

    更新日期:2016-06-01 00:00:00

  • MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

    abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0964-x

    authors: Yiallouras C,Mylonas N,Damianou C

    更新日期:2014-07-01 00:00:00

  • Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis.

    abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02087-w

    authors: Atehortúa A,Garreau M,Simon A,Donal E,Lederlin M,Romero E

    更新日期:2020-02-01 00:00:00

  • Breast tumor classification using different features of quantitative ultrasound parametric images.

    abstract:RATIONALE AND OBJECTIVES:The ultrasound B-mode-based morphological and texture analysis and Nakagami parametric imaging have been proposed to characterize breast tumors. Since these three feature categories of ultrasonic tissue characterization supply information on different physical characteristics of breast tumors, ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-01908-8

    authors: Hsu SM,Kuo WH,Kuo FC,Liao YY

    更新日期:2019-04-01 00:00:00

  • Patch-based classification of gallbladder wall vascularity from laparoscopic images using deep learning.

    abstract:PURPOSE:In this study, we propose a deep learning approach for assessment of gallbladder (GB) wall vascularity from images of laparoscopic cholecystectomy (LC). Difficulty in the visualization of GB wall vessels may be the result of fatty infiltration or increased thickening of the GB wall, potentially as a result of c...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02285-x

    authors: Loukas C,Frountzas M,Schizas D

    更新日期:2021-01-01 00:00:00

  • Analytical derivation of elasticity in breast phantoms for deformation tracking.

    abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1803-x

    authors: Groenhuis V,Visentin F,Siepel FJ,Maris BM,Dall'alba D,Fiorini P,Stramigioli S

    更新日期:2018-10-01 00:00:00

  • Formal verification of software-based medical devices considering medical guidelines.

    abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0919-2

    authors: Daw Z,Cleaveland R,Vetter M

    更新日期:2014-01-01 00:00:00

  • Ultrasound texture-based CAD system for detecting neuromuscular diseases.

    abstract:PURPOSE:Diagnosis of neuromuscular diseases in ultrasonography is a challenging task since experts are often unable to discriminate between healthy and pathological cases. A computer-aided diagnosis (CAD) system for skeletal muscle ultrasonography was developed and tested for myositis detection in ultrasound images of ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1133-6

    authors: König T,Steffen J,Rak M,Neumann G,von Rohden L,Tönnies KD

    更新日期:2015-09-01 00:00:00

  • A framework for correcting brain retraction based on an eXtended Finite Element Method using a laser range scanner.

    abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0958-8

    authors: Li P,Wang W,Song Z,An Y,Zhang C

    更新日期:2014-07-01 00:00:00

  • Fast and flexible distance measures for treatment planning.

    abstract:PURPOSE:Distance measures are required for diagnoses, therapy decision and documentation. With today's high-resolution CT and MR imaging techniques, high- quality images have become possible. Yet, manual measurement can be tedious. We present a method for automatically determining different distance-based measures on s...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0519-3

    authors: Rössling I,Cyrus C,Dornheim L,Boehm A,Preim B

    更新日期:2010-11-01 00:00:00