Decision support system for the planning of minimally invasive aortic valve replacement surgery.

Abstract:

PURPOSE:Minimally invasive aortic valve replacement (MIAVR) procedures remain more complex and technically challenging compared to conventional full sternotomy surgery. This technique involves a restricted surgical field and a limited workspace, which is, at present, strictly reserved for the most experienced surgeons. The MIAVR clinical outcomes are strongly dependent on the appropriate choice of the thoracic incision. This work presents a decision support system to optimize, through an interactive visualization interface, the exposure of the target structure in a limited field of view. METHODS:Our approach is based on the computation of relevant anatomical measurements from preoperative CT images, and it takes into account the surgical guidelines in order to propose the surgical access that best fits the patient's morphology. RESULTS:The proposed planning system was applied and tested on 30 datasets from patients affected by severe aortic stenosis for validation purposes. We evaluated the accuracy of the automatic detections and the measurements calculated by the system with those chosen manually by the expert. CONCLUSIONS:In 87% of thirty cases, the surgical strategy proposed by the decision support system was correct. For the remaining cases, the graphical user interface (GUI) allowed the user to manually adjust the anatomical features.

authors

Li H,Castro M,Haigron P,Verhoye JP,Ruggieri VG

doi

10.1007/s11548-018-1725-7

subject

Has Abstract

pub_date

2018-08-01 00:00:00

pages

1245-1255

issue

8

eissn

1861-6410

issn

1861-6429

pii

10.1007/s11548-018-1725-7

journal_volume

13

pub_type

杂志文章
  • Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction.

    abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02021-0

    authors: Raposo C,Barreto JP,Sousa C,Ribeiro L,Melo R,Oliveira JP,Marques P,Fonseca F,Barrett D

    更新日期:2019-09-01 00:00:00

  • Automated objective surgical skill assessment in the operating room from unstructured tool motion in septoplasty.

    abstract:PURPOSE:Previous work on surgical skill assessment using intraoperative tool motion has focused on highly structured surgical tasks such as cholecystectomy and used generic motion metrics such as time and number of movements. Other statistical methods such as hidden Markov models (HMM) and descriptive curve coding (DCC...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1194-1

    authors: Ahmidi N,Poddar P,Jones JD,Vedula SS,Ishii L,Hager GD,Ishii M

    更新日期:2015-06-01 00:00:00

  • Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy.

    abstract:PURPOSE:Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we pro...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02181-4

    authors: Kalia M,Mathur P,Tsang K,Black P,Navab N,Salcudean S

    更新日期:2020-07-01 00:00:00

  • Incorporating prior shape knowledge via data-driven loss model to improve 3D liver segmentation in deep CNNs.

    abstract:PURPOSE:Convolutional neural networks (CNNs) have obtained enormous success in liver segmentation. However, there are several challenges, including low-contrast images, and large variations in the shape, and appearance of the liver. Incorporating prior knowledge in deep CNN models improves their performance and general...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02085-y

    authors: Mohagheghi S,Foruzan AH

    更新日期:2020-02-01 00:00:00

  • Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

    abstract:PURPOSE:Epidural and spinal needle insertions, as well as facet joint denervation and injections are widely performed procedures on the lumbar spine for delivering anesthesia and analgesia. Ultrasound (US)-based approaches have gained popularity for accurate needle placement, as they use a non-ionizing, inexpensive and...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1552-2

    authors: Behnami D,Sedghi A,Anas EMA,Rasoulian A,Seitel A,Lessoway V,Ungi T,Yen D,Osborn J,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2017-06-01 00:00:00

  • Automatic detection of perforator vessels using infrared thermography in reconstructive surgery.

    abstract:PURPOSE:Knowing the location of the blood vessels supplying the skin and subcutaneous tissue is a requirement during the planning of tissue transfer in reconstructive surgery. Commonly used imaging techniques such as computed tomography angiography and indocyanine green angiography expose the patient to radiation or a ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1892-6

    authors: Unger M,Markfort M,Halama D,Chalopin C

    更新日期:2019-03-01 00:00:00

  • Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT.

    abstract:PURPOSE:Accurate target delineation is a critical step in radiotherapy. In this study, a robust contour propagation method is proposed to help physicians delineate lung tumors in four-dimensional computer tomography (4D-CT) images efficiently and accurately. METHODS:The proposed method starts with manually delineated ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1457-5

    authors: Liu Y,Jin R,Chen M,Song E,Xu X,Zhang S,Hung CC

    更新日期:2016-12-01 00:00:00

  • Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

    abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0921-8

    authors: Qian K,Ando T,Nakamura K,Liao H,Kobayashi E,Yahagi N,Sakuma I

    更新日期:2014-03-01 00:00:00

  • Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1228-8

    authors: Wagner ME,Gellrich NC,Friese KI,Becker M,Wolter FE,Lichtenstein JT,Stoetzer M,Rana M,Essig H

    更新日期:2016-01-01 00:00:00

  • Statistical model based analysis of bone mineral density of lumbar spine.

    abstract:OBJECTIVE:For planning surgical interventions at the spine affected by osteoporosis, accurate information about the local bone quality in terms of anchorage strength for implants is very important. Based on previous work on automated bone quality assessment on the proximal femur with a completely automated model-based ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0287-0

    authors: Leber S,Fritscher KD,Schmoelz W,Schubert R

    更新日期:2009-05-01 00:00:00

  • Estimating needle tip deflection in biological tissue from a single transverse ultrasound image: application to brachytherapy.

    abstract:PURPOSE:This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. METHODS:We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1329-4

    authors: Rossa C,Sloboda R,Usmani N,Tavakoli M

    更新日期:2016-07-01 00:00:00

  • Dual-robot ultrasound-guided needle placement: closing the planning-imaging-action loop.

    abstract:PURPOSE:Precise needle placement is an important task during several medical procedures. Ultrasound imaging is often used to guide the needle toward the target region in soft tissue. This task remains challenging due to the user's dependence on image quality, limited field of view, moving target, and moving needle. In ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1408-1

    authors: Kojcev R,Fuerst B,Zettinig O,Fotouhi J,Lee SC,Frisch B,Taylor R,Sinibaldi E,Navab N

    更新日期:2016-06-01 00:00:00

  • A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

    abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1309-8

    authors: Fusaglia M,Hess H,Schwalbe M,Peterhans M,Tinguely P,Weber S,Lu H

    更新日期:2016-08-01 00:00:00

  • Differential geometry-based techniques for characterization of boundary roughness of pulmonary nodules in CT images.

    abstract:PURPOSE:Boundary roughness of a pulmonary nodule is an important indication of its malignancy. The irregularity of the shape of a nodule is represented in terms of a few diagnostic characteristics such as spiculation, lobulation, and sphericity. Quantitative characterization of these diagnostic characteristics is essen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1284-0

    authors: Dhara AK,Mukhopadhyay S,Saha P,Garg M,Khandelwal N

    更新日期:2016-03-01 00:00:00

  • Automatic thalamus and hippocampus segmentation from MP2RAGE: comparison of publicly available methods and implications for DTI quantification.

    abstract:PURPOSE:In both structural and functional MRI, there is a need for accurate and reliable automatic segmentation of brain regions. Inconsistent segmentation reduces sensitivity and may bias results in clinical studies. The current study compares the performance of publicly available segmentation tools and their impact o...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1433-0

    authors: Næss-Schmidt E,Tietze A,Blicher JU,Petersen M,Mikkelsen IK,Coupé P,Manjón JV,Eskildsen SF

    更新日期:2016-11-01 00:00:00

  • Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    abstract:PURPOSE:Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constraine...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1421-4

    authors: Chan JL,Mazilu D,Miller JG,Hunt T,Horvath KA,Li M

    更新日期:2016-10-01 00:00:00

  • A preregistered STAMP method for image-guided temporal bone surgery.

    abstract:OBJECTIVES:Image-guided otological surgeries require minimal invasiveness and high accuracy, and these two factors usually compete with each other. Our recently developed registration method, called the STAMP method, showed minimal invasiveness with accuracy comparable to that of the current more invasive registration ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0916-5

    authors: Oka M,Cho B,Matsumoto N,Hong J,Jinnouchi M,Ouchida R,Komune S,Hashizume M

    更新日期:2014-01-01 00:00:00

  • Edge map analysis in chest X-rays for automatic pulmonary abnormality screening.

    abstract:PURPOSE:Our particular motivator is the need for screening HIV+ populations in resource-constrained regions for the evidence of tuberculosis, using posteroanterior chest radiographs (CXRs). METHOD:The proposed method is motivated by the observation that abnormal CXRs tend to exhibit corrupted and/or deformed thoracic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1359-6

    authors: Santosh KC,Vajda S,Antani S,Thoma GR

    更新日期:2016-09-01 00:00:00

  • Patient-specific estimation of detailed cochlear shape from clinical CT images.

    abstract:PURPOSE:A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detai...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1701-7

    authors: Kjer HM,Fagertun J,Wimmer W,Gerber N,Vera S,Barazzetti L,Mangado N,Ceresa M,Piella G,Stark T,Stauber M,Reyes M,Weber S,Caversaccio M,González Ballester MÁ,Paulsen RR

    更新日期:2018-03-01 00:00:00

  • Unravelling the effect of data augmentation transformations in polyp segmentation.

    abstract:PURPOSE:Data augmentation is a common technique to overcome the lack of large annotated databases, a usual situation when applying deep learning to medical imaging problems. Nevertheless, there is no consensus on which transformations to apply for a particular field. This work aims at identifying the effect of differen...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02262-4

    authors: Sánchez-Peralta LF,Picón A,Sánchez-Margallo FM,Pagador JB

    更新日期:2020-12-01 00:00:00

  • Multimodal mixed reality visualisation for intraoperative surgical guidance.

    abstract:PURPOSE:In the last decade, there has been a great effort to bring mixed reality (MR) into the operating room to assist surgeons intraoperatively. However, progress towards this goal is still at an early stage. The aim of this paper is to propose a MR visualisation platform which projects multiple imaging modalities to...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02165-4

    authors: Cartucho J,Shapira D,Ashrafian H,Giannarou S

    更新日期:2020-05-01 00:00:00

  • Predicting surgical skill from the first N seconds of a task: value over task time using the isogony principle.

    abstract:PURPOSE:Most evaluations of surgical workflow or surgeon skill use simple, descriptive statistics (e.g., time) across whole procedures, thereby deemphasizing critical steps and potentially obscuring critical inefficiencies or skill deficiencies. In this work, we examine off-line, temporal clustering methods that chunk ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1606-5

    authors: French A,Lendvay TS,Sweet RM,Kowalewski TM

    更新日期:2017-07-01 00:00:00

  • Four-dimensional computed tomography angiography analysis of internal carotid arteries opacification at the skull base to detect delayed cerebral ischemia: a feasibility study.

    abstract:PURPOSE:Delayed cerebral ischemia represents a significant cause of poor functional outcome for patients with vasospasm after subarachnoid hemorrhage. We investigated whether delayed cerebral ischemia could be detected by the arterial opacification of internal carotid artery at the level of the skull base. METHODS:In ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02268-y

    authors: Ognard J,Cheddad El Aouni M,Dissaux B,Jomaah R,Rousseau PY,Burdin V,Ben Salem D,Gentric JC

    更新日期:2020-12-01 00:00:00

  • Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis.

    abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02087-w

    authors: Atehortúa A,Garreau M,Simon A,Donal E,Lederlin M,Romero E

    更新日期:2020-02-01 00:00:00

  • Deep neural maps for unsupervised visualization of high-grade cancer in prostate biopsies.

    abstract::Prostate cancer (PCa) is the most frequent noncutaneous cancer in men. Early detection of PCa is essential for clinical decision making, and reducing metastasis and mortality rates. The current approach for PCa diagnosis is histopathologic analysis of core biopsies taken under transrectal ultrasound guidance (TRUS-gui...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01950-0

    authors: Sedghi A,Pesteie M,Javadi G,Azizi S,Yan P,Kwak JT,Xu S,Turkbey B,Choyke P,Pinto P,Wood B,Rohling R,Abolmaesumi P,Mousavi P

    更新日期:2019-06-01 00:00:00

  • Multi-trajectories automatic planner for StereoElectroEncephaloGraphy (SEEG).

    abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1004-1

    authors: De Momi E,Caborni C,Cardinale F,Casaceli G,Castana L,Cossu M,Mai R,Gozzo F,Francione S,Tassi L,Lo Russo G,Antiga L,Ferrigno G

    更新日期:2014-11-01 00:00:00

  • Automated aorta segmentation in low-dose chest CT images.

    abstract:PURPOSE:Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0924-5

    authors: Xie Y,Padgett J,Biancardi AM,Reeves AP

    更新日期:2014-03-01 00:00:00

  • Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1752-4

    authors: Graf EC,Ott I,Praceus J,Bourier F,Lueth TC

    更新日期:2018-06-01 00:00:00

  • Computer-aided cephalometric landmark annotation for CBCT data.

    abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1453-9

    authors: Codari M,Caffini M,Tartaglia GM,Sforza C,Baselli G

    更新日期:2017-01-01 00:00:00

  • Myocardium tracking via matching distributions.

    abstract:OBJECTIVE:The goal of this study is to investigate automatic myocardium tracking in cardiac Magnetic Resonance (MR) sequences using global distribution matching via level-set curve evolution. Rather than relying on the pixelwise information as in existing approaches, distribution matching compares intensity distributio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-008-0265-y

    authors: Ben Ayed I,Li S,Ross I,Islam A

    更新日期:2009-01-01 00:00:00