Continuous roadmapping in liver TACE procedures using 2D-3D catheter-based registration.

Abstract:

PURPOSE:Fusion of pre/perioperative images and intra-operative images may add relevant information during image-guided procedures. In abdominal procedures, respiratory motion changes the position of organs, and thus accurate image guidance requires a continuous update of the spatial alignment of the (pre/perioperative) information with the organ position during the intervention. METHODS:In this paper, we propose a method to register in real time perioperative 3D rotational angiography images (3DRA) to intra-operative single-plane 2D fluoroscopic images for improved guidance in TACE interventions. The method uses the shape of 3D vessels extracted from the 3DRA and the 2D catheter shape extracted from fluoroscopy. First, the appropriate 3D vessel is selected from the complete vascular tree using a shape similarity metric. Subsequently, the catheter is registered to this vessel, and the 3DRA is visualized based on the registration results. The method is evaluated on simulated data and clinical data. RESULTS:The first selected vessel, ranked with the shape similarity metric, is used more than 39 % in the final registration and the second more than 21 %. The median of the closest corresponding points distance between 2D angiography vessels and projected 3D vessels is 4.7-5.4 mm when using the brute force optimizer and 5.2-6.6 mm when using the Powell optimizer. CONCLUSION:We present a catheter-based registration method to continuously fuse a 3DRA roadmap arterial tree onto 2D fluoroscopic images with an efficient shape similarity.

authors

Ambrosini P,Ruijters D,Niessen WJ,Moelker A,van Walsum T

doi

10.1007/s11548-015-1218-x

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

1357-70

issue

9

eissn

1861-6410

issn

1861-6429

journal_volume

10

pub_type

杂志文章
  • Translatory hip kinematics measured with optoelectronic surgical navigation.

    abstract:PURPOSE:An optoelectronic surgical navigation system was used to detect small but measurable translational motion of human hip cadavers in high-range passive motions. Kinematic data were also examined to demonstrate the role of soft tissues in constraining hip translation. METHODS:Twelve cadaver hips were scanned usin...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1629-y

    authors: Zakani S,Rudan JF,Ellis RE

    更新日期:2017-08-01 00:00:00

  • Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    abstract:PURPOSE:Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. METHODS:The path searching method is based on...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1282-2

    authors: Chen X,Cheng J,Gu X,Sun Y,Politis C

    更新日期:2016-04-01 00:00:00

  • Detection and modelling of contacts in explicit finite-element simulation of soft tissue biomechanics.

    abstract:PURPOSE:Realistic modelling of soft tissue biomechanics and mechanical interactions between tissues is an important part of biomechanically-informed surgical image-guidance and surgical simulation. This submission details a contact-modelling pipeline suitable for implementation in explicit matrix-free FEM solvers. Whil...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1142-5

    authors: Johnsen SF,Taylor ZA,Han L,Hu Y,Clarkson MJ,Hawkes DJ,Ourselin S

    更新日期:2015-11-01 00:00:00

  • A CAD of fully automated colonic polyp detection for contrasted and non-contrasted CT scans.

    abstract:PURPOSE:Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In this paper, we aimed to develop a fully integrated CAD system for automated detection of p...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1521-9

    authors: Tulum G,Bolat B,Osman O

    更新日期:2017-04-01 00:00:00

  • Computational modeling of abdominal hernia laparoscopic repair with a surgical mesh.

    abstract:PURPOSE:Although new techniques and prostheses have been introduced in ventral hernia surgery, abdominal hernia repair still presents complications, such as recurrence, pain, and discomfort. Thus, this work implements a computational method aimed at evaluating biomechanical aspects of the abdominal hernia laparoscopic ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-017-1681-7

    authors: Todros S,Pachera P,Baldan N,Pavan PG,Pianigiani S,Merigliano S,Natali AN

    更新日期:2018-01-01 00:00:00

  • Analysis of the micro-migration of sliding hip screws by using point-based registration.

    abstract:PURPOSE:The favored treatment for many hip fractures is a sliding hip screw, and its usage is expected to increase in the future. Failures can be reduced, and complications detected earlier by semi-automated CT image analysis. The most frequent failure is due to the screw cut-out from the femoral head. METHODS:An imag...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-010-0498-4

    authors: Raudaschl P,Fritscher K,Roth T,Kammerlander C,Schubert R

    更新日期:2010-09-01 00:00:00

  • Long-term experience with setup and implementation of an IHE-based image management and distribution system in intersectoral clinical routine.

    abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1819-2

    authors: Schwind F,Münch H,Schröter A,Brandner R,Kutscha U,Brandner A,Heinze O,Bergh B,Engelmann U

    更新日期:2018-11-01 00:00:00

  • Automated pulmonary nodule CT image characterization in lung cancer screening.

    abstract:PURPOSE:In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malign...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1245-7

    authors: Reeves AP,Xie Y,Jirapatnakul A

    更新日期:2016-01-01 00:00:00

  • A pre-operative planning framework for global registration of laparoscopic ultrasound to CT images.

    abstract:PURPOSE:Laparoscopic ultrasound (LUS) enhances the safety of laparoscopic liver resection by enabling real-time imaging of internal structures such as vessels. However, LUS probes can be difficult to use, and many tumours are iso-echoic and hence are not visible. Registration of LUS to a pre-operative CT or MR scan has...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1799-2

    authors: Ramalhinho J,Robu MR,Thompson S,Gurusamy K,Davidson B,Hawkes D,Barratt D,Clarkson MJ

    更新日期:2018-08-01 00:00:00

  • Computer-aided cephalometric landmark annotation for CBCT data.

    abstract:PURPOSE:Nowadays, with the increased diffusion of Cone Beam Computerized Tomography (CBCT) scanners in dental and maxillo-facial practice, 3D cephalometric analysis is emerging. Maxillofacial surgeons and dentists make wide use of cephalometric analysis in diagnosis, surgery and treatment planning. Accuracy and repeata...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-016-1453-9

    authors: Codari M,Caffini M,Tartaglia GM,Sforza C,Baselli G

    更新日期:2017-01-01 00:00:00

  • Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

    abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-011-0548-6

    authors: Weil YA,Liebergall M,Mosheiff R,Singer SB,Joskowicz L,Khoury A

    更新日期:2011-09-01 00:00:00

  • Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks.

    abstract:PURPOSE:In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to rea...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01965-7

    authors: Pfeiffer M,Riediger C,Weitz J,Speidel S

    更新日期:2019-07-01 00:00:00

  • The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures.

    abstract:BACKGROUND:Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-009-0282-5

    authors: Ohuchida K,Kenmotsu H,Yamamoto A,Sawada K,Hayami T,Morooka K,Hoshino H,Uemura M,Konishi K,Yoshida D,Maeda T,Ieiri S,Tanoue K,Tanaka M,Hashizume M

    更新日期:2009-03-01 00:00:00

  • A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    abstract:PURPOSE:Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. METHOD...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1078-9

    authors: Dagnino G,Mattos LS,Caldwell DG

    更新日期:2015-02-01 00:00:00

  • A framework for correcting brain retraction based on an eXtended Finite Element Method using a laser range scanner.

    abstract:BACKGROUND:Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. METHODS:We used a linear elastic biomechanical model, which deforms based on the...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0958-8

    authors: Li P,Wang W,Song Z,An Y,Zhang C

    更新日期:2014-07-01 00:00:00

  • Real-time inextensible surgical thread simulation.

    abstract:PURPOSE:This paper discusses a real-time simulation method of inextensible surgical thread based on the Cosserat rod theory using position-based dynamics (PBD). The method realizes stable twining and knotting of surgical thread while including inextensibility, bending, twisting and coupling effects. METHODS:The Cosser...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1739-1

    authors: Xu L,Liu Q

    更新日期:2018-07-01 00:00:00

  • Regional infarction identification from cardiac CT images: a computer-aided biomechanical approach.

    abstract:PURPOSE:Regional infarction identification is important for heart disease diagnosis and management, and myocardial deformation has been shown to be effective for this purpose. Although tagged and strain-encoded MR images can provide such measurements, they are uncommon in clinical routine. On the contrary, cardiac CT i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s11548-016-1404-5

    authors: Wong KC,Tee M,Chen M,Bluemke DA,Summers RM,Yao J

    更新日期:2016-09-01 00:00:00

  • Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

    abstract:PURPOSE:Organ motion due to patient breathing introduces a technical challenge for dosimetry and lung tumor treatment by hadron therapy. Accurate dose distribution estimation requires patient-specific information on tumor position, size, and shape as well as information regarding the material density and stopping power...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0935-2

    authors: Manescu P,Ladjal H,Azencot J,Beuve M,Testa E,Shariat B

    更新日期:2014-05-01 00:00:00

  • Analytical derivation of elasticity in breast phantoms for deformation tracking.

    abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-018-1803-x

    authors: Groenhuis V,Visentin F,Siepel FJ,Maris BM,Dall'alba D,Fiorini P,Stramigioli S

    更新日期:2018-10-01 00:00:00

  • Dynamic contrast-enhanced computed tomography diagnosis of primary liver cancers using transfer learning of pretrained convolutional neural networks: Is registration of multiphasic images necessary?

    abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01987-1

    authors: Yamada A,Oyama K,Fujita S,Yoshizawa E,Ichinohe F,Komatsu D,Fujinaga Y

    更新日期:2019-08-01 00:00:00

  • Temporal enhancement of 2D color Doppler echocardiography sequences by fragment-based frame reordering and refinement.

    abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-01926-0

    authors: Terentjev AB,Perrin DP,Settlemier SH,Zurakowski D,Smirnov PO,Del Nido PJ,Shturts IV,Vasilyev NV

    更新日期:2019-04-01 00:00:00

  • Formal verification of software-based medical devices considering medical guidelines.

    abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-013-0919-2

    authors: Daw Z,Cleaveland R,Vetter M

    更新日期:2014-01-01 00:00:00

  • Automatic phase prediction from low-level surgical activities.

    abstract:PURPOSE:Analyzing surgical activities has received a growing interest in recent years. Several methods have been proposed to identify surgical activities and surgical phases from data acquired in operating rooms. These context-aware systems have multiple applications including: supporting the surgical team during the i...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1195-0

    authors: Forestier G,Riffaud L,Jannin P

    更新日期:2015-06-01 00:00:00

  • PyDBS: an automated image processing workflow for deep brain stimulation surgery.

    abstract:PURPOSE:Deep brain stimulation (DBS) is a surgical procedure for treating motor-related neurological disorders. DBS clinical efficacy hinges on precise surgical planning and accurate electrode placement, which in turn call upon several image processing and visualization tasks, such as image registration, image segmenta...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1007-y

    authors: D'Albis T,Haegelen C,Essert C,Fernández-Vidal S,Lalys F,Jannin P

    更新日期:2015-02-01 00:00:00

  • Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis.

    abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-019-02087-w

    authors: Atehortúa A,Garreau M,Simon A,Donal E,Lederlin M,Romero E

    更新日期:2020-02-01 00:00:00

  • XDose: toward online cross-validation of experimental and computational X-ray dose estimation.

    abstract:PURPOSE:As the spectrum of X-ray procedures has increased both for diagnostic and for interventional cases, more attention is paid to X-ray dose management. While the medical benefit to the patient outweighs the risk of radiation injuries in almost all cases, reproducible studies on organ dose values help to plan preve...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02298-6

    authors: Roser P,Birkhold A,Preuhs A,Ochs P,Stepina E,Strobel N,Kowarschik M,Fahrig R,Maier A

    更新日期:2021-01-01 00:00:00

  • [¹¹C]acetate and PET/CT assessment of muscle activation in rat studies.

    abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-015-1260-8

    authors: Trombella S,García D,Colin DJ,Germain S,Seimbille Y,Ratib O

    更新日期:2016-05-01 00:00:00

  • Augmentation of haptic feedback for teleoperated robotic surgery.

    abstract:PURPOSE:A frequently mentioned lack of teleoperated surgical robots is the lack of haptic feedback. Haptics are not only able to mirror force information from the situs, but also to provide spatial guidance according to a surgical plan. However, superposition of the two haptic information can lead to overlapping and ma...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-020-02118-x

    authors: Schleer P,Kaiser P,Drobinsky S,Radermacher K

    更新日期:2020-03-01 00:00:00

  • Multi-trajectories automatic planner for StereoElectroEncephaloGraphy (SEEG).

    abstract:PURPOSE:StereoElectroEncephaloGraphy (SEEG) is done to identify the epileptogenic zone of the brain using several multi-lead electrodes whose positions in the brain are pre-operatively defined. Intracranial hemorrhages due to disruption of blood vessels can cause major complications of this procedure ([Formula: see tex...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-014-1004-1

    authors: De Momi E,Caborni C,Cardinale F,Casaceli G,Castana L,Cossu M,Mai R,Gozzo F,Francione S,Tassi L,Lo Russo G,Antiga L,Ferrigno G

    更新日期:2014-11-01 00:00:00

  • Accurate two-dimensional cardiac strain calculation using adaptive windowed Fourier transform and Gabor wavelet transform.

    abstract:PURPOSE:Cardiac strain calculated from tagged magnetic resonance (MR) images provides clinicians information about abnormalities of heart-wall motion in patients. It is important to develop an accurate method to determine the cardiac strain efficiently. An adaptive windowed harmonic phase (AWHARP) method is proposed fo...

    journal_title:International journal of computer assisted radiology and surgery

    pub_type: 杂志文章

    doi:10.1007/s11548-012-0689-2

    authors: Fu YB,Chui CK,Teo CL

    更新日期:2013-01-01 00:00:00